Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

FAST (FAST AUTONOMOUS SCANNING TOOLKIT)

SF-23-006 FAST (FAST AUTONOMOUS SCANNING TOOLKIT)The software is deployed on an edge computing device at the beamline computer attached to a scanning microscope. It iteratively analyzes the data collected, then identifies new scan positions to scan next and directs the positioners that move the sample (or probe beam) to these positions. Overall, it identifies a sparse set of scan positions that are sufficient to image the full sample. This can reduce the scan time by >60%.

KANDEL, SAUGAT↗

Multi-scan computed tomography defect detectability

Systems and methods for representing internal defects of an object to determine defect detectability using a multi-scan computed tomography (CT) approach are disclosed. A defect-free object may be scanned using a CT machine. In one or more separate scans, phantom defects may be imaged and the resulting projections combined and reconstructed to represent internal defects. The air-normalized intensities of the object and the phantom defect may be used to represent voids and inclusions. Subtraction of materials may be represented by the quotient of the air-normalized intensities thereof, and the addition of materials may be represented by the product of the air-normalized intensities thereof. A void may be represented by subtracting a phantom defect scan from the object scan. An inclusion may be represented by creating a void, scanning an additional phantom defect, and adding the additional phantom defect in the volume created by the void.

Schiefelbein, Bryan E.↗

Exploring leakage in dielectric films via automated experiments in scanning probe microscopy

Here electronic conduction pathways in dielectric thin films are explored using automated experiments in scanning probe microscopy (SPM). In this study, we use large field of view scanning to identify the position of localized conductive spots and develop an SPM workflow to probe their dynamic behavior at higher spatial resolution as a function of time, voltage, and scanning process in an automated fashion. Using this approach, we observe the variable behaviors of the conductive spots in a 20-nm-thick ferroelectric Hf 0.54 Zr 0.48 O 2 film, where conductive spots disappear and reappear during continuous scanning. There are also fresh conductive spots that develop during scanning. The automated workflow is universal and can be integrated into a wide range of microscopy techniques, including SPM, electron microscopy, optical microscopy, and chemical imaging.

36 MATERIALS SCIENCE↗

Symmetry Breaking with the SCAN Density Functional Describes Strong Correlation in the Singlet Carbon Dimer

The SCAN (strongly constrained and appropriately normed) meta-generalized gradient approximation (meta-GGA), which satisfies all 17 exact constraints that a meta-GGA can satisfy, accurately describes equilibrium bonds that are normally correlated. With symmetry breaking, it also accurately describes some sd equilibrium bonds that are strongly correlated. While sp equilibrium bonds are nearly always normally correlated, the C 2 singlet ground state is known from correlated wave function theory to be a rare case of strong correlation in an sp equilibrium bond. Earlier work that calculated atomization energies of the molecular sequence B 2 , C 2 , O 2 , and F 2 in the local spin density approximation (LSDA), the Perdew–Burke–Ernzerhof (PBE) GGA, and the SCAN meta-GGA, without symmetry breaking in the molecule, found that only SCAN was accurate enough to reveal an anomalous under-binding for C 2 . Here, this work shows that spin symmetry breaking in singlet C 2 , which involves the appearance of net up- and down-spin densities on opposite sides (not ends) of the bond, corrects that underbinding, with a small SCAN atomization-energy error more like that of the other three molecules, suggesting that symmetry breaking with an advanced density functional might reliably describe strong correlation. This article also discusses some general aspects of symmetry breaking and the insights into strong correlation that symmetry breaking can bring. The normally correlated low-lying triplet excited state has the right vertical excitation energy in SCAN but not in LSDA or PBE, where the triplet is a false ground state. Fractional occupation numbers are found only for the symmetry-unbroken singlet and only in LSDA and PBE GGA.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of open circuit immersion and vertex potential on potentiodynamic polarization scans of metallic biomaterials

Abstract Electrodes made of commercially pure titanium (CP-Ti) and a CoCrMo alloy are immersed at an open circuit in a phosphate buffer saline electrolyte at room temperature for different durations prior to electrochemical analyses. Open circuit potential measurements, electrochemical impedance spectroscopy measurements, and cyclic potentiodynamic polarization (CPP) scans are used to assess the impact of the immersion time on derived property values. Stable passivation layers formed on both materials during immersion. The corrosion potentials determined from the anodic legs of CPP scans become more cathodic, and the corrosion currents decrease to lower values after longer immersion times. Measured currents indicate the layers formed on CP-Ti stabilize during forward anodic scans and persist to the vertex potential, whereas passivation breakdown occurs during anodic scans with CoCrMo with active corrosion at voltages up to the vertex potential. The characteristics of the return cathodic legs of CPP scans represent the surface conditions at the vertex potential: characteristic corrosion property values derived from the test responses represent passive surfaces on CP-Ti and leached surfaces on CoCrMo rather than intrinsic properties of those materials.

36 MATERIALS SCIENCE↗

Region-based convolutional neural network for wind turbine wake characterization from scanning lidars

A convolutional neural network is applied to lidar scan images from three experimental campaigns to identify and characterize wind turbine wakes. Initially developed as a proof-of-concept model and applied to a single data set in complex terrain, the model is now improved and generalized and applied to two other unique lidar data sets, one located near an escarpment and one located offshore. The model, initially developed using lidar scans collected in predominantly westerly flow, exhibits sensitivity to wind flow direction. The model is thus successfully generalized through implementing a standard rotation process to scan images before input into the convolutional neural network to ensure the flow is westerly. The sample size of lidar scans used to train the model is increased, and along with the generalization process, these changes to the model are shown to enhance accuracy and robustness when characterizing dissipating and asymmetric wakes. Applied to the offshore data set in which nearly 20 wind turbine wakes are included per scan, the improved model exhibits a 95% success rate in characterizing wakes and a 74% success rate in characterizing dissipating wake fragments. The improved model is shown to generalize well to the two new data sets, although an increase in wake characterization accuracy is offset by an increase in model sensitivity and false positive wake identifications.

17 WIND ENERGY↗

High‐speed 4‐dimensional scanning transmission electron microscopy using compressive sensing techniques

Abstract Here we show that compressive sensing allows 4‐dimensional (4‐D) STEM data to be obtained and accurately reconstructed with both high‐speed and reduced electron fluence. The methodology needed to achieve these results compared to conventional 4‐D approaches requires only that a random subset of probe locations is acquired from the typical regular scanning grid, which immediately generates both higher speed and the lower fluence experimentally. We also consider downsampling of the detector, showing that oversampling is inherent within convergent beam electron diffraction (CBED) patterns and that detector downsampling does not reduce precision but allows faster experimental data acquisition. Analysis of an experimental atomic resolution yttrium silicide dataset shows that it is possible to recover over 25 dB peak signal‐to‐noise ratio in the recovered phase using 0.3% of the total data. Lay abstract : Four‐dimensional scanning transmission electron microscopy (4‐D STEM) is a powerful technique for characterizing complex nanoscale structures. In this method, a convergent beam electron diffraction pattern (CBED) is acquired at each probe location during the scan of the sample. This means that a 2‐dimensional signal is acquired at each 2‐D probe location, equating to a 4‐D dataset. Despite the recent development of fast direct electron detectors, some capable of 100kHz frame rates, the limiting factor for 4‐D STEM is acquisition times in the majority of cases, where cameras will typically operate on the order of 2kHz. This means that a raster scan containing 256^2 probe locations can take on the order of 30s, approximately 100‐1000 times longer than a conventional STEM imaging technique using monolithic radial detectors. As a result, 4‐D STEM acquisitions can be subject to adverse effects such as drift, beam damage, and sample contamination. Recent advances in computational imaging techniques for STEM have allowed for faster acquisition speeds by way of acquiring only a random subset of probe locations from the field of view. By doing this, the acquisition time is significantly reduced, in some cases by a factor of 10‐100 times. The acquired data is then processed to fill‐in or inpaint the missing data, taking advantage of the inherently low‐complex signals which can be linearly combined to recover the information. In this work, similar methods are demonstrated for the acquisition of 4‐D STEM data, where only a random subset of CBED patterns are acquired over the raster scan. We simulate the compressive sensing acquisition method for 4‐D STEM and present our findings for a variety of analysis techniques such as ptychography and differential phase contrast. Our results show that acquisition times can be significantly reduced on the order of 100‐300 times, therefore improving existing frame rates, as well as further reducing the electron fluence beyond just using a faster camera.

Robinson, Alex W.↗

FAST Drift Scan Survey for Ηι Intensity Mapping: I. Preliminary Data Analysis

This work presents the initial results of the drift-scan observation for the neutral hydrogen (Hi) intensity mapping survey with the Five-hundred-meter Aperture Spherical radio Telescope (FAST). The data analyzed in this work were collected in night observations from 2019 through 2021. The primary findings are based on 28 hr of drift-scan observation carried out over 7 nights in 2021, which covers 60 deg 2 sky area. Our main findings are, first, our calibration strategy can successfully correct both the temporal and bandpass gain variation over the 4 hr drift-scan observation. Second, the continuum maps of the surveyed region are made with frequency resolution of 28 kHz and pixel area of $_{2.95\,{\mathrm{arcmin}}^{2}}$. The pixel noise levels of the continuum maps are slightly higher than the forecast assuming $T$ sys = 20 K, which are 36.0 mK (for 10.0 s integration time) at the 1050–1150 MHz band, and 25.9 mK (for 16.7 s integration time) at the 1323–1450 MHz band, respectively. Third, the flux-weighted differential number count is consistent with the NRAO-VLA Sky Survey (NVSS) catalog down to the confusion limit ~7 mJy beam –1 . Finally, the continuum flux measurements of the sources are consistent with those found in the literature. The difference in the flux measurement of 81 isolated NVSS sources is about 6.3%. Our research offers a systematic analysis for the FAST Hi intensity mapping drift-scan survey and serves as a helpful resource for further cosmology and associated galaxies sciences with the FAST drift-scan survey.

79 ASTRONOMY AND ASTROPHYSICS↗

An algorithm for physics informed scan path optimization in additive manufacturing

Site specific microstructure control is a critical research area within the field of additive manufacturing due to its potential to revolutionize part performance. One way to achieve site specific microstructure control is through control of the solidification conditions via the construction of intricate scan paths; however, the search space for such a problem is large. Previous attempts only considered the solidification conditions at the top surface while also requiring either lots of manual-fine tuning or large amounts of computational resources. This paper introduces a general method for scan path optimization which considers the solidification conditions in the bulk of the material without an increase in computational expense. This method consists of three core components:1. A heat transfer model for simulating the temperature field at a given time.2. A surrogate model which takes scan pattern information and temperature data and predicts the solidification conditions of the bulk as well as the meltpool depths for a spot melt.3. A decision algorithm to decide which spot melt should be printed next based on the outputs of the surrogate model.Each of these components can be changed without changing the overall method. Within this work, this method is applied in the creation of an algorithm containing a semi-analytic heat transfer model to simulate the temperature field, a fully convolutional neural network (FCNN) as the surrogate model, and a greedy decision algorithm. The resulting algorithm produced complex scan patterns which gave strong results for simulated microstructure control.

36 MATERIALS SCIENCE↗

Toward implementing autonomous adaptive data acquisition for scanning hyperspectral imaging of biological systems

Autonomous experimentation is an emerging area of research, primarily related to autonomous vehicles, scientific combinatorial discovery approaches in materials science and drug discovery, and iterative research loops of planning, experimentation, and analysis. However, autonomous approaches developed in these contexts are difficult to apply to high-dimensional mapping technologies, such as scanning hyperspectral imaging of biological systems, due to sample complexity and heterogeneity. We briefly cover the history of adaptive sampling algorithms and surrogate modeling in order to define autonomous adaptive data acquisition as an objective-based, flexible building block for future biological imaging experimentation driven by intelligent infrastructure. We subsequently summarize the recent implementations of autonomous adaptive data acquisition (AADA) for scanning hyperspectral imaging, assess how these address the difficulties of autonomous approaches in hyperspectral imaging, and highlight the AADA design variation from a goal-oriented perspective. Finally, we present a modular AADA architecture that embeds AADA-driven flexible building blocks to address the challenge of time resolution for high-dimensional scanning hyperspectral imaging of nonequilibrium dynamical systems. In our example research-driven experimental design case, we propose an AADA infrastructure for time-resolved, noninvasive, and label-free scanning hyperspectral imaging of living biological systems. This AADA infrastructure can accurately target the correct state of the system for experimental workflows that utilize subsequent expensive, high-information-content analytical techniques.

59 BASIC BIOLOGICAL SCIENCES↗

Fast scanning in x-ray microscopy: the effects of offset in the central stop position

Scanning of lightweight circular diffractive optics, separate from central stops and apertures, is emerging as an approach to exploit advances in synchrotron x-ray sources. We consider the effects in a scanning microscope of offsets between the optic and its central stop and find that scan ranges of up to about half the diameter of the optic are possible with only about a 10% increase in the focal spot width. Finally, for large scanning ranges, we present criteria for the working distance between the last aperture and the specimen to be imaged.

47 OTHER INSTRUMENTATION↗

Scan‐Path‐ and Initial‐State‐Dependent Superdomain Switching in (111)‐Oriented PZT

Polarization switching in ferroelectric materials arises from the collective evolution of complex domain hierarchies, yet deterministic control over these processes remains challenging. Here, we investigate scan-path- and initial-state-dependent switching in epitaxial (111)-oriented PbZr 0.2 Ti 0.8 O 3 thin films using automated AFM-based writing combined with quantitative 3D piezoresponse force microscopy. We show that the scan trajectory acts as an experimentally accessible control parameter for superdomain formation. Box-in-box raster scans reproducibly stabilize ordered stripe superdomains with a reduced subset of symmetry-allowed variants, whereas spiral trajectories generate frustrated mixed-variant states with a broader distribution of final microstructures. Automated pulsing experiments further show that the local superdomain configuration at the nucleation site strongly influences the final written morphology. Phase-field modeling qualitatively reproduces the contrast between representative initial-state geometries and supports the role of compatibility constraints among competing ferroelastic pathways. These findings establish scan-path and initial-state engineering as practical handles to program ferroic order in hierarchical ferroelectric domain structures.

Vasudevan, Rama K. [Oak Ridge National Laboratory ↗

Demonstration of an AI-driven workflow for autonomous high-resolution scanning microscopy

Abstract Modern scanning microscopes can image materials with up to sub-atomic spatial and sub-picosecond time resolutions, but these capabilities come with large volumes of data, which can be difficult to store and analyze. We report the Fast Autonomous Scanning Toolkit (FAST) that addresses this challenge by combining a neural network, route optimization, and efficient hardware controls to enable a self-driving experiment that actively identifies and measures a sparse but representative data subset in lieu of the full dataset. FAST requires no prior information about the sample, is computationally efficient, and uses generic hardware controls with minimal experiment-specific wrapping. We test FAST in simulations and a dark-field X-ray microscopy experiment of a WSe 2 film. Our studies show that a FAST scan of <25% is sufficient to accurately image and analyze the sample. FAST is easy to adapt for any scanning microscope; its broad adoption will empower general multi-level studies of materials evolution with respect to time, temperature, or other parameters.

47 OTHER INSTRUMENTATION↗

Nanoscale electric field imaging with an ambient scanning quantum sensor microscope

Nitrogen-vacancy (NV) center in diamond is a promising quantum sensor with remarkably versatile sensing capabilities. While scanning NV magnetometry is well-established, NV electrometry has been so far limited to bulk diamonds. Here we demonstrate imaging external alternating (AC) and direct (DC) electric fields with a single NV at the apex of a diamond scanning tip under ambient conditions. A strong electric field screening effect is observed at low frequencies. We quantitatively measure its frequency dependence and overcome this screening by mechanically oscillating the tip for imaging DC fields. Our scanning NV electrometry achieved an AC E-field sensitivity of 26 mV μm -1 Hz -1/2 , a DC E-field gradient sensitivity of 2 V μm -2 Hz -1/2 , and sub-100 nm resolution limited by the NV-sample distance. Our work represents an important step toward building a scanning-probe-based multimodal quantum sensing platform.

47 OTHER INSTRUMENTATION↗

A machine learning decision criterion for reducing scan time for hyperspectral neutron computed tomography systems

We present the first machine learning-based autonomous hyperspectral neutron computed tomography experiment performed at the Spallation Neutron Source. Hyperspectral neutron computed tomography allows the characterization of samples by enabling the reconstruction of crystallographic information and elemental/isotopic composition of objects relevant to materials science. High quality reconstructions using traditional algorithms such as the filtered back projection require a high signal-to-noise ratio across a wide wavelength range combined with a large number of projections. This results in scan times of several days to acquire hundreds of hyperspectral projections, during which end users have minimal feedback. To address these challenges, a golden ratio scanning protocol combined with model-based image reconstruction algorithms have been proposed. This novel approach enables high quality real-time reconstructions from streaming experimental data, thus providing feedback to users, while requiring fewer yet a fixed number of projections compared to the filtered back projection method. In this paper, we propose a novel machine learning criterion that can terminate a streaming neutron tomography scan once sufficient information is obtained based on the current set of measurements. Our decision criterion uses a quality score which combines a reference-free image quality metric computed using a pre-trained deep neural network with a metric that measures differences between consecutive reconstructions. The results show that our method can reduce the measurement time by approximately a factor of five compared to a baseline method based on filtered back projection for the samples we studied while automatically terminating the scans.

97 MATHEMATICS AND COMPUTING↗

Characterization of turbulence under different stability conditions using lidar scanning data

The spatiotemporal scales of turbulence in the boundary layer flow vary with the static stability of the atmosphere. For example, turbulence structures in unstable conditions are often found to be large and coherent, whereas the turbulent structures in stable conditions are relatively small and sporadic. To better understand the behavior of such turbulent structures under different atmospheric stability conditions in the lower atmosphere, herein, we use scanning lidar data collected over several months during the US Department of Energy's second Wind Forecast Improvement Project (WFIP 2) in 2016. The radial velocity data from scanning lidar were gathered along the horizontal plane (PPI mode) and were analyzed using proper orthogonal decomposition (POD) and spectral energy methods. The results from these analyses show that the turbulent structures in daytime unstable conditions are different from those present during nighttime stable conditions in terms of amount of energy and coherent structures. The POD energy is distributed more evenly in all the higher spatial modes in the daytime unstable case compared to the nighttime stable case. Besides characterizing the turbulence in the flow, the lidar data were also used to compare the simulated flow field generated from the WRF-LES framework (Weather Research and Forecasting - large-eddy simulation) with the scanning lidar data. The results from both simulated and lidar scanned data show similar structures orienting the streak-like structure along the mean wind. This indicates that the streak-like structures can exist in the real atmosphere during unstable atmospheric condition cases.

Rai, Raj K.↗

Scanning electrochemical probe microscopy investigation of two-dimensional materials

Research interests in two-dimensional (2D) materials have seen exponential growth owing to their unique and fascinating properties. The highly exposed lattice planes coupled with tunable electronic states of 2D materials have created manifold opportunities in the design of new platforms for energy conversion and sensing applications. Still, challenges in understanding the electrochemical (EC) characteristics of these materials arise from the complexity of both intrinsic and extrinsic heterogeneities that can obscure structure–activity correlations. Scanning EC probe microscopic investigations offer unique benefits in disclosing local EC reactivities at the nanoscale level that are otherwise inaccessible with macroscale methods. This review summarizes recent progress in applying techniques of scanning EC microscopy (SECM) and scanning EC cell microscopy (SECCM) to obtain distinctive insights into the fundamentals of 2D electrodes. We showcase the capabilities of EC microscopies in addressing the roles of defects, thickness, environments, strain, phase, stacking, and many other aspects in the heterogeneous electron transfer, ion transport, electrocatalysis, and photoelectrochemistry of representative 2D materials and their derivatives. Perspectives for the advantages, challenges, and future opportunities of scanning EC probe microscopy investigation of 2D structures are discussed.

36 MATERIALS SCIENCE↗

A multi-modal scanning system to digitize CBRNE emergency response scenes

A handheld system developed to digitize a contextual understanding of the scene at a chemical, biological, radiological, nuclear and/or explosives (CBRNE) events is described. The system uses LiDAR and cameras to create a colorized 3D model of the environment, which helps domain experts that are supporting responders in the field. To generate the digitized model, a responder scans any suspicious objects and the surroundings by carrying the system through the scene. The scanning system provides a real-time user interface to inform the user about scanning progress and to indicate any areas that may have been missed either by the LiDAR sensors or the cameras. Currently, the collected data are post-processed on a different device, building a colorized triangular mesh of the encountered scene, with the intention of moving this pipeline to the scanner at a later point. The mesh is sufficiently compressed to be sent over a reduced bandwidth connection to a remote analyst. Furthermore, the system tracks fiducial markers attached to diagnostic equipment that is placed around the suspicious object. The resulting tracking information can be transmitted to remote analysts to further facilitate their supporting efforts. The paper will discuss the system's design, software components, the user interface used for scanning a scene, the necessary procedures for calibration of the sensors, and the processing steps of the resulting data. The discussion will close by evaluating the system's performance on 11 scenes.

Salathe, Marco↗