Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sampling calorimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals that are aligned in a dispersive configuration to select the Kα1 line of the x-ray tube anode material. The entire device, including the x-ray tube, can be easily hand-carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100 μm–200 μm for the x-ray tubes used here) and is unfocused in the cross-dispersion direction so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi soft x-ray spectrometer, which had 819 μm square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs), which have effective theoretical FWHM energy resolution of 0.125 eV, 0.197 eV, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our Cr Kα1 monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

47 OTHER INSTRUMENTATION↗

Exploring the Nature of Neutrinos with the Deep Underground Neutrino Experiment (DUNE)

The Deep Underground Neutrino Experiment (DUNE) is a next-generation experimental program designed to study the behaviour of neutrino oscillation. DUNE will utilize a neutrino beam originating at Fermilab, near Chicago, and will leverage a detector at Fermilab (Near Detector) and a detector 1300 km away in South Dakota (Far Detector), south of Saskatchewan. In the first phase of DUNE, its Far Detector will comprise of two 10,000 ton (fiducial) liquid argon (LAr) time-projection chamber (TPC) modules – powerful tracking calorimeter detectors – placed nearly a mile underground. With this large, sensitive, underground detector, DUNE aims to collect a high statistics and pure sample of neutrinos at the Far Detector. This setup also offers the potential to study non-beam physical processes via e.g. neutrinos produced in the atmosphere, supernova neutrino bursts, and/or solar neutrinos, etc. A second phase will aim to add more detector mass and expand the program. The Near Detector will consist of a LAr TPC module as well: critical to constraining systematic uncertainties in the oscillation analysis. However, this LAr TPC will have a novel design using a pixel-based readout instead of the traditional wire-based readout. This and the segmentation of the LAr TPC into multiple units are crucial in mitigating the high multiplicity of neutrino interactions expected in any readout window given its proximity to the beam. The Near Detector will feature additional components and capability beyond the LAr TPC, allowing one to deeply characterize the neutrino flux. Due to the complexity of this experimental program, several smaller-scale prototype detectors have been operating to test, validate, and improve both the technical designs and software for processing and analyzing events. By operating in charged particle test beams or neutrino beams, several of the prototypes are also capable of producing valuable results. Canadian institutions are involved in the realization of the DUNE through efforts with both the Near and Far Detectors and prototypes. DUNE is anticipated to begin operating near the end of this decade/the beginning of the next. This talk will focus on the overall DUNE program, for example its ultimate plans, status, and the efforts with prototypes.

Howard, Bruce [York U., Canada; Fermilab]↗

Making Every Microgram Count: Nanocalorimetry for Nuclear and Ultra-Rare Materials

The thermal analysis of nuclear and ultra-rare materials plays an important role in nuclear energy, planetary, environmental, and technological settings. Heat effects associated with the sample temperature, heat capacity, phase transformation, radiation damage and crystallographic defects are some of the thermochemistry measurements made with conventional differential scanning calorimeters. However, the measurement capabilities of the of traditional DSCs are often restricted when studying limited ultra-rare accessory minerals or materials submitted to extreme conditions, such as radiation in the nuclear fuel cycle and high pressure. We investigate the usage of nanocalorimetry for the energetic analysis of nuclear or ultra-rare materials, such as irradiated materials and high-pressure phases, with an emphasis on radiation damage and heat capacity measurements. Examples of how nanocalorimetry has been previously used for phase transitions, melting, and nucleation in ultra-fast heating and cooling rates are presented. Finally, an outlook of the field and future work, including beneficial safety and environmental outcomes from the potential usage of nanocalorimetry, are shown.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Refining fast calorimeter simulations with a Schrödinger Bridge

Machine learning-based simulations, especially calorimeter simulations, are promising tools for approximating the precision of classical high energy physics simulations with a fraction of the generation time. Nearly all methods proposed so far learn neural networks that map a random variable with a known probability density, like a Gaussian, to realistic-looking events. In many cases, physics events are not close to Gaussian and so these neural networks have to learn a highly complex function. We study an alternative approach: Schrödinger bridge Quality Improvement via Refinement of Existing Lightweight Simulations (SQuIRELS). SQuIRELS leverages the power of diffusion-based neural networks and Schrödinger bridges to map between samples where the probability density is not known explicitly. We apply SQuIRELS to the task of refining a classical fast simulation to approximate a full classical simulation. On simulated calorimeter events, we find that SQuIRELS is able to reproduce highly non-trivial features of the full simulation with a fraction of the generation time.

Calorimeter methods↗

High-bandwidth frequency domain multiplexed readout of transition-edge sensors for neutrinoless double beta decay searches

The next-generation of cryogenic neutrinoless double-beta decay experiments require increasingly fast readout in order to improve background discrimination. These experiments, operated as cryogenic calorimeters at ∼ 10 mK, are usually read out by high-impedance neutron transmutation doped (NTD) thermistors, which provide good energy resolution, but are limited by ∼ 1 ms response times. Superconducting detectors, such as transition-edge sensors (TESs) with a time resolution of ∼ 100 μs, offer superior timing performance over NTD semiconductor bolometers. To make this technology viable for an application to a thousand or more channels, multiplexed readout is necessary in order to minimize the thermal load and radioactive contamination induced by the readout. Frequency-domain multiplexing readout (fMUX) for TESs, previously developed at Berkeley Lab and McGill University, is currently in use for mm-wave telescopes with detector sampling rates in the order of 100 Hz. We demonstrate a new readout system, based on the McGill/Berkeley digital fMux readout, to satisfy the higher bandwidth and noise requirements of the next generation of TES-instrumented cryogenic calorimeters. Each multiplexing readout module comprises 10 superconducting resonators in the 1–5 MHz range and a DC superconducting quantum interference device (DC-SQUID), interfaced to high-speed field programmable gate array (FPGA)-based electronics for digital signal processing and low-latency SQUID feedback. The new readout samples detectors at 156 kHz, three orders of magnitude faster than its cosmology-oriented predecessor, and demonstrates a stable feedback bandwidth of 3 kHz in a real TES-based system.

47 OTHER INSTRUMENTATION↗

Studies of Cherenkov photon production in PbF 2 crystals using proton beams at Fermilab

Future lepton colliders such as the FCC-ee, CEPC, ILC, or a muon collider will collect large data samples that allow precision physics studies with unprecedented accuracy, especially when the data is collected by innovative state-of-the-art detectors. An electromagnetic calorimeter based on scintillating crystals, designed to separately record Cherenkov and scintillation light, can achieve precision measurements of electrons and photons without sacrificing jet energy resolution, given adequate light collection efficiency and separation. This paper presents initial measurements from a program aimed at developing such a calorimeter system for future colliders. Finally, we focus on using PbF 2 crystals to enhance the understanding of Cherenkov light collection, marking the first step in this endeavor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lead tungstate calorimeter of the Jefferson Lab Eta Factory experiment

A new electromagnetic calorimeter (ECAL) consisting of 1596 lead tungstate PbWO 4 scintillating crystals has been fabricated and installed in the experimental Hall D at Jefferson Lab (JLab). The highgranularity, high-resolution calorimeter is required by the JLab Eta Factory experiment, whose main physics goal is to study rare decays of eta mesons. The ECAL replaced the inner part of the forward lead glass calorimeter of the GlueX detector. Signals from the detector will be digitized using twelve-bit flash analog-to-digital converters operated at a sampling rate of 250 MHz. The ECAL is integrated into the trigger system of the GlueX detector using electronics modules designed at JLab. The ECAL is currently at the commissioning stage and should be ready for the physics run in January 2025. We will give an overview of the JEF experiment, the design and construction of the ECAL, and the integration of the detector and its infrastructure into the Hall D experimental setup.

Somov, Alexander [Thomas Jefferson National Accele↗

The JLab Eta Factory (JEF) experiment

The new experiment, JLab Eta Factory (JEF), in the experimental Hall D at Jefferson Lab will extend the physics potential of the GlueX detector beyond the main spectroscopy program and perform precision measurements of various ?(?)decays with emphasis on rare neutral modes. The physics program of the experiment spans from precision tests of low-energy QCD to search of gauge bosons in the mass range below 1 GeV coupling the SM sector to the dark sector. Photoproduction of highly boosted ?(?)mesons using a tagged photon beam, good detection of recoil proton and multi-photon final states will allow to suppress background and collect high-statistics data sample of ?mesons. All these provide many advantages over other ?(?)experiments. The JEF experiment requires to upgrade the inner part of the forward lead glass calorimeter of the GlueX detector with high-granularity, high-resolution lead tungstate PbWO4 scintillating crystals. The calorimeter insert is currently under construction at Jeffeson Lab. The detector will be ready to take data in 2024. An overview of the JEF project will be presented.

Somov, Alexander↗

High command fidelity electromagnetically driven calorimeter

An example apparatus can comprise an emitter to emit radio frequency radiation, an absorber that changes temperature based on emissions from the emitter, and one or more sensors to measure a temperature difference between a sample and a reference coupled to the absorber.

42 ENGINEERING↗

Electron and photon energy calibration with the ATLAS detector using LHC Run 2 data

This paper presents the electron and photon energy calibration obtained with the ATLAS detector using 140 fb -1 of LHC proton-proton collision data recorded at $\sqrt{s}$ = 13 TeV between 2015 and 2018. Methods for the measurement of electron and photon energies are outlined, along with the current knowledge of the passive material in front of the ATLAS electromagnetic calorimeter. The energy calibration steps are discussed in detail, with emphasis on the improvements introduced in this paper. The absolute energy scale is set using a large sample of Z-boson decays into electron-positron pairs, and its residual dependence on the electron energy is used for the first time to further constrain systematic uncertainties. The achieved calibration uncertainties are typically 0.05% for electrons from resonant Z-boson decays, 0.4% at E T ~ 10 GeV, and 0.3% at E T ~ 1 TeV; for photons at E T ~ 60 GeV, they are 0.2% on average. This is more than twice as precise as the previous calibration. The new energy calibration is validated using J/ψ → ee and radiative Z-boson decays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the use of neural networks for energy reconstruction in high-granularity calorimeters

We contrasted the performance of deep neural networks — Convolutional Neural Network (CNN) and Graph Neural Network (GNN) — to current state of the art energy regression methods in a finely 3D-segmented calorimeter simulated by GEANT4. This comparative benchmark gives us some insight to assess the particular latent signals neural network methods exploit to achieve superior resolution. A CNN trained solely on a pure sample of pions achieved substantial improvement in the energy resolution for both single pions and jets over the conventional approaches. It maintained good performance for electron and photon reconstruction. We also used the Graph Neural Network (GNN) with edge convolution to assess the importance of timing information in the shower development for improved energy reconstruction. We implement a simple simulation based correction to the energy sum derived from the fraction of energy deposited in the electromagnetic shower component. This serves as an approximate dual-readout analogue for our benchmark comparison. Although this study does not include the simulation of detector effects, such as electronic noise, the margin of improvement seems robust enough to suggest these benefits will endure in real-world application. We also find reason to infer that the CNN/GNN methods leverage latent features that concur with our current understanding of the physics of calorimeter measurement.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

End-to-End Jet Classification of Boosted Top Quarks with CMS Open Data

We describe a novel application of the end-to-end deep learning technique to the task of discriminating top quark-initiated jets from those originating from the hadronization of a light quark or a gluon. The end-to-end deep learning technique combines deep learning algorithms and low-level detector representation of the high-energy collision event. In this study, we use lowlevel detector information from the simulated CMS Open Data samples to construct the top jet classifiers. To optimize classifier performance we progressively add low-level information from the CMS tracking detector, including pixel detector reconstructed hits and impact parameters, and demonstrate the value of additional tracking information even when no new spatial structures are added. Relying only on calorimeter energy deposits and reconstructed pixel detector hits, the end-to-end classifier achieves a ROC-AUC score of 0.975±0.002 for the task of classifying boosted top quark jets. After adding derived track quantities, the classifier ROC-AUC score increases to 0.9824±0.0013, serving as the first performance benchmark for these CMS Open Data samples.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

J/ ψ -hadron correlations at midrapidity in pp collisions at $\sqrt{s}$ = 13 TeV

We report on the measurement of inclusive, non-prompt, and prompt J/ψ-hadron correlations by the ALICE Collaboration at the CERN Large Hadron Collider in pp collisions at a center-of-mass energy of 13 TeV. The correlations are studied at midrapidity (|y| < 0.9) in the transverse momentum ranges p T < 40 GeV/c for the J/ψ and 0.15 < p T < 10 GeV/c and |η| < 0.9 for the associated hadrons. The measurement is based on minimum bias and high multiplicity data samples corresponding to integrated luminosities of L int = 34 nb −1 and L int = 6.9 pb −1 , respectively. In addition, two more data samples are employed, requiring, on top of the minimum bias condition, a threshold on the tower energy of E = 4 and 9 GeV in the ALICE electromagnetic calorimeters, which correspond to integrated luminosities of L int = 0.9 pb −1 and L int = 8.4 pb −1 , respectively. The azimuthally integrated near and away side yields of associated charged hadrons per J/ψ trigger are presented as a function of the J/ψ and associated hadron transverse momentum. The measurements are discussed in comparison to PYTHIA calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

End-to-end jet classification of boosted top quarks with the CMS open data

Here we describe a novel application of the end-to-end deep learning technique to the task of discriminating top quark-initiated jets from those originating from the hadronization of a light quark or a gluon. The end-to-end deep learning technique uses low-level detector representation of high-energy collision event as inputs to deep learning algorithms. In this study, we use low-level detector information from the simulated Compact Muon Solenoid (CMS) open data samples to construct the top jet classifiers. To optimize classifier performance we progressively add low-level information from the CMS tracking detector, including pixel detector reconstructed hits and impact parameters, and demonstrate the value of additional tracking information even when no new spatial structures are added. Relying only on calorimeter energy deposits and reconstructed pixel detector hits, the end-to-end classifier achieves an area under the receiver operator curve (AUC) score of 0.975 ± 0.002 for the task of classifying boosted top quark jets. After adding derived track quantities, the classifier AUC score increases to 0.9824 ± 0.0013, serving as the first performance benchmark for these CMS open data samples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Jefferson Lab Eta Factory Experiment and Applications of PbWO4 Calorimeters in Future Experimental Facilities

The goal of the new JLab Eta Factory (JEF) experiment, conducted with the GlueX detector in Hall D at Jefferson Lab, is to perform measurements of various ¿(') decays with a primary focus on rare neutral modes. The experiment’s physics program ranges from precision tests of low-energy QCD to searches for gauge bosons with masses below 1 GeV that could couple the Standard Model (SM) sector to the dark sector. The experiment will collect a high-statistics data sample of ¿(') mesons produced via a beam of tagged photons. The GlueX detector features a large, nearly uniform acceptance for both neutral and charged particles, enabling efficient identification of complex multi-particle final states. To meet the requirements of the JEF experiment, the inner section of the forward lead-glass calorimeter in the GlueX detector has been upgraded with lead tungstate (PbWO4) scintillating crystals. PbWO4 offers exceptional characteristics, such as a small radiation length and Molire radius, and large light yield, that make it ideal for constructing high- granularity, high-resolution, radiation-hard detectors. These properties enable excellent spatial separation and energy resolution of reconstructed electromagnetic showers, establishing PbWO4 as the material of choice for many high-precision experiments. The JEF experiment began data collection in April 2025 and will operate concurrently with the GlueX experiment, whose primary objective is the search for gluonic excitations in the meson spectrum. I will give an overview of the JEF experiment, the GlueX detector, and the feasibility of further upgrades to support future ¿ physics studies. Special attention will be given to the newly constructed PbWO4 scintillating calorimeter and recent advancements in calorimeter instrumentation.

Somov, Alexander↗

Porting HEP Parameterized Calorimeter Simulation Code to GPUs

The High Energy Physics (HEP) experiments, such as those at the Large Hadron Collider (LHC), traditionally consume large amounts of CPU cycles for detector simulations and data analysis, but rarely use compute accelerators such as GPUs. As the LHC is upgraded to allow for higher luminosity, resulting in much higher data rates, purely relying on CPUs may not provide enough computing power to support the simulation and data analysis needs. As a proof of concept, we investigate the feasibility of porting a HEP parameterized calorimeter simulation code to GPUs. We have chosen to use FastCaloSim, the ATLAS fast parametrized calorimeter simulation. While FastCaloSim is sufficiently fast such that it does not impose a bottleneck in detector simulations overall, significant speed-ups in the processing of large samples can be achieved from GPU parallelization at both the particle (intra-event) and event levels; this is especially beneficial in conditions expected at the high-luminosity LHC, where extremely high per-event particle multiplicities will result from the many simultaneous proton-proton collisions. We report our experience with porting FastCaloSim to NVIDIA GPUs using CUDA. A preliminary Kokkos implementation of FastCaloSim for portability to other parallel architectures is also described.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low Temperature Microcalorimeters for Decay Energy Spectroscopy

Low Temperature Detectors have been used to measure embedded radioisotopes in a measurement mode known as Decay Energy Spectroscopy (DES) since 1992. DES microcalorimeter measurements have been used for applications ranging from neutrino mass measurements to metrology to measurements for safeguards and medical nuclides. While the low temperature detectors have extremely high intrinsic energy resolution (several times better than semiconductor detectors), the energy resolution achieved in practice is strongly dependent on factors such as sample preparation method. This review seeks to present the literature consensus on what has been learned by looking at the energy resolution as a function of various choices of detector, absorber, and sample preparation methods.

47 OTHER INSTRUMENTATION↗

Response of a CMS HGCAL silicon-pad electromagnetic calorimeter prototype to 20–300 GeV positrons

The Compact Muon Solenoid collaboration is designing a new high-granularity endcap calorimeter, HGCAL, to be installed later this decade. As part of this development work, a prototype system was built, with an electromagnetic section consisting of 14 double-sided structures, providing 28 sampling layers. Each sampling layer has an hexagonal module, where a multipad large-area silicon sensor is glued between an electronics circuit board and a metal baseplate. The sensor pads of approximately 1.1 cm$^{2}$ are wire-bonded to the circuit board and are readout by custom integrated circuits. The prototype was extensively tested with beams at CERN's Super Proton Synchrotron in 2018. Based on the data collected with beams of positrons, with energies ranging from 20 to 300 GeV, measurements of the energy resolution and linearity, the position and angular resolutions, and the shower shapes are presented and compared to a detailed Geant4 simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗