Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Two-stage chain sampling inspection plans with different sample sizes in the two stages

A further generalization of the family of 'two-stage' chain sampling inspection plans is developed - viz, the use of different sample sizes in the two stages. Evaluation of the operating characteristics is accomplished by the Markov chain approach of the earlier work, modified to account for the different sample sizes. Markov chains for a number of plans are illustrated and several algebraic solutions are developed. Since these plans involve a variable amount of sampling, an evaluation of the average sampling number (ASN) is developed. A number of OC curves and ASN curves are presented. Some comparisons with plans having only one sample size are presented and indicate that improved discrimination is achieved by the two-sample-size plans.

Stephens, K. S.↗

How successful were the lunar sampling tools: Implications for sampling Mars

Like the Mars Sample Return endeavor, the Apollo lunar-sample program began with definition of strategy for sample collection and of scientific requirements for sampling hardware design. Several lessons can be illustrated by specific tools. The evolution of drive tubes from narrow 2 cm diameter, thick-walled tubes (used on Apollo 11, 12 and 14) to 4 cm diameter, thin-walled tubes used on Apollo 15, 16, and 17) as an example of the improvements made possible during multiple missions. The original Apollo 11 drive tube was designed to work in fluffy soil; thus, only 50 percent of the relatively dense lunar soil was recovered, and the core was distorted. The final configuration resulted in nearly 100 pct recovery with little distortion. The surface samplers (Contact Soil Sampling Devices) were designed to collect the upper 100 micrometer or the upper 1 mm of soil. It was over 2 years after the mission before these particularly specific samplers were opened because interest in them waned. Both core tubes and surface samplers were difficult to open in the laboratory. The Apollo Lunar Sample Return Containers (ALSRCs) were constructed with one indium and 2 Viton seals. They were closed on the lunar surface. Interior container pressures measured upon return to the laboratory indicate that these seals were not reliable in the lunar environment. Also, choice of indium as a sealing material interfered with siderophile analyses of samples.

Allton, J. H.↗

A Trade Study and Metric for Penetration and Sampling Devices for Possible Use on the NASA 2003 and 2005 Mars Sample Return Missions

The scientific exploration of Mars will require the collection and return of subterranean samples to Earth for examination. This necessitates the use of some type of device or devices that possesses the ability to effectively penetrate the Martian surface, collect suitable samples and return them to the surface in a manner consistent with imposed scientific constraints. The first opportunity for such a device will occur on the 2003 and 2005 Mars Sample Return missions, being performed by NASA. This paper reviews the work completed on the compilation of a database containing viable penetrating and sampling devices, the performance of a system level trade study comparing selected devices to a set of prescribed parameters and the employment of a metric for the evaluation and ranking of the traded penetration and sampling devices, with respect to possible usage on the 03 and 05 sample return missions. The trade study performed is based on a select set of scientific, engineering, programmatic and socio-political criterion. The use of a metric for the various penetration and sampling devices will act to expedite current and future device selection.

McConnell, Joshua B.↗

Sample Manipulation System for Sample Analysis at Mars

The Sample Analysis at Mars (SAM) instrument will analyze Martian samples collected by the Mars Science Laboratory Rover with a suite of spectrometers. This paper discusses the driving requirements, design, and lessons learned in the development of the Sample Manipulation System (SMS) within SAM. The SMS stores and manipulates 74 sample cups to be used for solid sample pyrolysis experiments. Focus is given to the unique mechanism architecture developed to deliver a high packing density of sample cups in a reliable, fault tolerant manner while minimizing system mass and control complexity. Lessons learned are presented on contamination control, launch restraint mechanisms for fragile sample cups, and mechanism test data.

Mumm, Erik↗

The Evolution of the Orbiting Sample Container for a Future Mars Sample Return

Although NASA has no specific plans at this time to return samples from Mars, the Program Formulation Office of the Mars Exploration Program sponsors ongoing mission concept studies, systems analyses, and technology investments which explore different strategies for the potential return of samples from Mars, consistent with the charter of the program and stated priorities of the science community. A critical component of such a campaign would be an Orbiting Sample container (OS), which would contain the Mars samples to be returned to Earth. This paper discusses the most recent efforts by the JPL’s Mars Formulation Office to mature an OS design planned for use on a potential Mars Sample Return (MSR) mission. Similar to the “Decadal Study Architecture” [1], the current MSR architecture envisions as a three-mission campaign with each mission serving a critical role towards returning Martian rock and atmospheric samples back to Earth. An OS would be a central piece of hardware in the proposed MSR architecture due to its interfaces to all the three missions of the potential campaign. Additionally, numerous stakeholders and subsystems such as science and planetary protection impose challenging requirements on the OS’s functions and capabilities. As a result, designing an OS that meets all the requirements is challenging and quite complex. The story of the OS’s evolution from black box concept thru to the current-and-still-maturing baseline design is the focus of this paper. From the OS’s launch off Earth aboard a Sample Retrieval Lander (SRL) through to return to Earth, the design and functional requirements generated by and for each stage of the OS’s mission are discussed. Then, with an understanding of what the OS would be required to do, a mapping of the main requirements to the design features of the current OS concept is explained. Many tests and analyses have been conducted to support and validate the current OS design. Results from test and analysis in the areas of aerothermal, impact dynamics, optical tracking, and radio electromagnetics are presented.

Spencer, David↗

Sample Return Container Opening Process Concept for Potential Mars Sample Return

Proposed Mars Sample Return (MSR) missions would require a pristine and secure opening method to ensure sample Contamination Control and backward Planetary Protection. In order to reach the samples, a series of five containers would need to be opened inside of a Mars Returned Sample Handling (MRSH) facility. The process would include opening the Containment Assurance Module (CAM) aboard the Earth Entry Vehicle (EEV), the Secondary Containment Vessel (SCV), Primary Containment Vessel (PCV), and the Orbiting Sample (OS) container, and finally removing and opening the Returned Sample Tube Assemblies (RSTA). Some of these containers can be opened by reversing the mechanical assembly process while others would require destructive means. Several containers are still in a conceptual design phase while others are en route to Mars aboard the M2020 rover. In order to inform the design of the containers that are still in the conceptual stages, a study was performed at each level of the containment assembly. The studies were used to determine the least destructive and most robust methods to disassemble and open the containers while minimizing risk to the samples or the personnel. In addition to the envisioned disassembly and breaching method, contingency plans were made for completing the disassembly if damage to the vehicle and containment system occurred.

Liu, Yang↗

The Dual-Rasp Sampling System Design with Closed Pneumatic Sample Transfer

The novel Dual-Rasp sampling system has been developed for landed missions to low gravity planetary bodies and is particularly well suited for the unique environment of Saturn’s moon Enceladus. The Dual-Rasp sampling system has two counter-rotating rasp cutters that remove material from the surface and direct it into a guide. The cuttings follow the guide into a sample collection cup. When the sampling collection completes, the tool reconfigures by rotating the guide to create a closed circuit for pneumatic sample transfer from the collection cup to science instruments on the lander. A valve opens a gas tank and the gas flows from that tank into the sample collection cup and down rigid tubing to the science instruments chamber on the lander. A two degree of freedom arm with base actuators is used to deploy the sampler and control its sampling location.

Heness, Andrew B.↗

Development and Demonstration of a Prototype Molten Salt Sampling System

Molten salt reactors (MSRs) offer potential operability and safety advantages when compared to commercial light water reactors (LWRs). However, operating experience with MSRs is sparse in comparison to what exists for LWRs. Further, the chemical and isotopic composition of the fuel and/or coolant salt is dynamic and difficult to characterize continuously, posing potential safety, operability, and safeguards unknowns that need to be addressed. A molten salt sampling system (MSSS) is regarded as a necessary subsystem within first generation MSRs used to obtain samples of salt for chemical and isotopic analysis in support of the need to monitor and control salt composition during operation. The MSSS is being developed using the Safety-in-Design (SiD) methodology, which incorporates incremental integration of safety analysis into the design process. The MSSS conceptual design emerging from the application of the early stages of the SiD methodology consists of a sample collection system and its housing, a freeze port, and inert gas control and delivery systems. This article describes the prototypes developed to test the functions of these MSSS subsystems, presents the results of testing in both dry and molten salt environments (including reliability data collection performed in accordance with the principles of SiD and the development of a semiquantitative fault tree model), and summarizes the opportunities for future design and testing enhancements based on the results of prototype testing.

molten salt reactor↗

The Combination of Rejection Sampling with Biased Probability Density Sampling (with Special Comments on MCNP "Cookie Cutter" Rejection)

Sampling from biased probability densities and rejection sampling are both very common Monte Carlo techniques. As far as I know, the combination of sampling from a biased density and rejection sampling has not been developed. This note develops the theory for sampling from a biased density and then accepting or rejecting that sampling.

97 MATHEMATICS AND COMPUTING↗

Mars Sample Recovery Helicopter: Rotorcraft to Retrieve the First Samples from the Martian Surface

The Mars Sample Return Mission (MSR) will carry the next set of Mars helicopters, Sample Recovery Helicopters (SRHs), to the Martian surface. After successfully demonstrating extraterrestrial flight in 2021, Ingenuity has acted as a “scout” for the Perseverance rover while the rover gathers samples of Martian soil. In 2028, the MSR mission will launch a lander and two Ingenuity-sized SRHs to retrieve these samples. These will be the first samples of the Martian surface delivered to Earth. The SRH project will maintain heritage from Ingenuity’s design when possible. However, several key changes must be made, including a ground mobility system, a robotic arm for tube manipulation, and the ability to carry the weight of a science payload (the sample tubes). In addition, the onboard software and cameras will be upgraded, and the rotor radius will be increased. Furthermore, new rotor performance and flight dynamics models and thorough characterization of vehicle limits will be required. The new vehicle design will be described, as well as validation and verification efforts to date.

Rotorcraft↗

Sample Tube Sealing for Future Proposed Mars Sample Return Missions

A key premise of a proposed Sample Caching Rover, a crucial element of the proposed Mars Sample Return (MSR) campaign, is that the samples could be packaged and left on Mars for an extended period of time (at least five Mars years) without loss of scientific value (Fig. 1). The MEPAG E2E-iSAG (2011) concluded that the single most important factor in preserving the scientific integrity of the samples during the interval between their collection and their analysis is effective sealing of the samples.

sample integrity↗

Deterministic Linear Time for Maximal Poisson‐Disk Sampling using Chocks without Rejection or Approximation

Abstract We show how to sample uniformly within the three‐sided region bounded by a circle, a radial ray, and a tangent, called a “chock.” By dividing a 2D planar rectangle into a background grid, and subtracting Poisson disks from grid squares, we are able to represent the available region for samples exactly using triangles and chocks. Uniform random samples are generated from chock areas precisely without rejection sampling. This provides the first implemented algorithm for precise maximal Poisson‐disk sampling in deterministic linear time. We prove O(n · M(b) log b), where n is the number of samples, b is the bits of numerical precision and M is the cost of multiplication. Prior methods have higher time complexity, take expected time, are non‐maximal, and/or are not Poisson‐disk distributions in the most precise mathematical sense. We fill this theoretical lacuna.

Mitchell, Scott A.↗

Introduction to Mars Sample Handling Workshop Series: Overview of Mars Sample Hazard Analysis

Samples returned from Mars should be contained and treated as though potentially hazardous until proven otherwise If sample containment cannot be verified en route to Earth, the sample and spacecraft should either be sterilized in space or not returned to Earth. Integrity of sample containment should be maintained through reentry and transfer to a receiving facility. Controlled distribution of unsterilized materials should only occur if analyses determine the sample not to contain a biological hazard. Planetary protection measures adopted for the first sample return should not be relaxed for subsequent missions without thorough scientific review and concurrence by an appropriate independent body

Rummel, John D.↗

Thermal design of the sample handling assembly in the sampling and caching subsystem on the Mars 2020 rover

The Mars 2020 Rover is scheduled to land on Mars on February 18, 2021. One of the primary mission objectives for the Mars 2020 Rover is to collect a set of Martian regolith samples for potential future return to Earth. Regolith and rock samples will be collected and placed into sample tubes using a coring drill, located at the end of a large Robotic Arm, on the outside of the rover. Filled sample tubes will be transferred from the outside of the Rover into the Adaptive Caching Assembly (ACA), located inside the Rover chassis, via the Bit Carousel. Once the filled sample tube is brought into the ACA, the Sample Handling Assembly (SHA) will transfer it to all of the internal processing stations of the ACA for volume assessment, sealing and finally drop-off on the Martian surface. The ACA is a volume within the rover chassis that is not temperature-controlled. Actuators inside the SHA and its End Effector (EE) must be warmed to above -55°C and -25°C, respectively, prior to use. This paper discusses the thermal design of the SHA that uses heaters and temperature sensors to warm up and maintain the temperature-sensitive arm components within temperature limits during operation. Thermal performance predictions for Mars surface operations are also presented.

Lee, Chern-Jiin↗

Thresholds of Temperature and Time for Mars Sample Return: Final Report of The Mars Sample Return Temperature-Time Tiger Team

The time-temperature tiger team (T4) was chartered by NASA and ESA to evaluate the risks to the scientific return of the MSR samples if they are exposed to temperatures between +30 and +60 ⁰C for different amounts of time. This team consists of 13 scientists, who were selected based on their scientific background to represent the scientific disciplines that are expected to be the ones that will be the most affected if such heating were to happen. The expertise of the team will help to understand whether exposing the MSR samples to temperatures between +30 and +60 ⁰C will pose any risk to the sample integrity and therefore, to future scientific investigations. Key processes identified by the T4 were: the release of volatiles by desorption and sublimation and release from condensed phases (interiors, decomposition, dehydration); chemical reactions including gas-gas and gas-solid; deliquescence of hygroscopic salts; acid/base interactions (potential for extreme pH conditions); aqueous redox reactions, isotopic exchange (aqueous phases, minerals, gasses, organic phases); condensation and freezing (in the after-heating cooling phase) and interactions with the sample tube materials. There is potential for multiple interactions and overlapping effects. For inorganic materials and the records they represent, over both long time scales (hours to days) and short time scales (minutes to hours) no temperature excursion above +30 °C could be accommodated without loss of science (Figure 1.1). While there will be some robust constituents (feldspars, quartz, pyroxenes, etc.) that are unaffected, there will also be some less robust constituents (salts, phyllosilicates, radicals, etc.) that are affected across all temperature ranges ≤60 °C. For organic materials, in particular organic biosignatures, the risks reflect that preservation is reliant on a number of processes, and a change in one component within a sample tube can affect another. For organic materials, over long timescales of hours to days no temperature excursion above +30 °C could be accommodated without loss of science, but over shorter time scales (minutes to hours), raising the temperature to 40 °C could be manageable without major disruption to science, whereas temperatures above 40 °C would lead to significant losses. The consideration of these findings by the MSR team will help to maintain the fidelity of samples returned from Mars in the future and maximize scientific return when analyzed in Earth laboratories.

Mark A Sephton↗

Solid phase sampling device and methods for point-source sampling of polar organic analytes

Sampling devices for sampling an aqueous source (e.g., field testing of ground water) for multiple different analytes are described. Devices include a solid phase extraction component for retention of a wide variety of targeted analytes. Devices include analyte derivatization capability for improved extraction of targeted analytes. Thus, a single device can be utilized to examine a sample source for a wide variety of analytes. Devices also include an isotope dilution capability that can prevent error introduction to the sample analysis and can correct for sample loss and degradation from the point of sampling until analysis as well as correction for incomplete or poor derivatization reactions. The devices can be field-deployable and rechargeable.

Boggess, Andrew J.↗

Solid-phase sampling device and methods for point-source sampling of polar organic analytes

Sampling devices for sampling an aqueous source (e.g., field testing of ground water) for multiple different analytes are described. Devices include a solid phase extraction component for retention of a wide variety of targeted analytes. Devices include analyte derivatization capability for improved extraction of targeted analytes. Thus, a single device can be utilized to examine a sample source for a wide variety of analytes. Devices also include an isotope dilution capability that can prevent error introduction to the sample analysis and can correct for sample loss and degradation from the point of sampling until analysis as well as correction for incomplete or poor derivatization reactions. The devices can be field-deployable and rechargeable.

Boggess, Andrew J.↗

CatMass : software for calculating optimal sample masses for X-ray absorption spectroscopy experiments involving complex sample compositions

This paper presents software for calculating the optimal mass of samples with complex compositions ( e.g. supported metal catalysts) for X-ray absorption spectroscopy (XAS) and scattering measurements. The ability to calculate the sample mass and other relevant parameters needed for an XAS measurement allows experimentalists to be better prepared in terms of detector selection, energy range of scan and overall time needed to complete the measurement, thus increasing efficiency. CatMass builds on existing sample mass calculators allowing users to determine the optimum sample preparation, collection geometry, usable energy range for a scan and approximate edge step of the absorption event. Visualization tools present the absorption calculation results in a format familiar to XAS experimentalists, with the added ability to save calculations and plots for future reference or recalculation. CatMass is a program broadly applicable in catalysis and is helpful for users with complex samples due to composition/stoichiometry or multiple competing elements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗