Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample preparation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Methods for Quantitative Thermal Analysis of Lithium Solid-State and Beyond Battery Safety

The use of differential scanning calorimetry (DSC) to measure the thermal behavior of individual components and electrolyte/electrode combinations is common. However, here we focus on DSC tests on an anode, cathode, and electrolyte (ACE) component combination over a temperature range that includes many of the phase transitions and key reactions (i.e., to 500 °C) that contribute to thermal runaway. This method can help quantify the complex reaction network in a full cell, thereby informing potential safety issues. Here, we used DSC heat flow data from a solid-state Li 0.43 CoO 2 +C+PVDF | LLZO | Li metal ACE sample and its components to quantify key factors affecting results. We focused on three areas: (1) ACE sample preparation and assembly in DSC pans, (2) DSC measurement parameters, and (3) heat flow analysis. Key points include the choice of component ratios (e.g., commercially relevant N:P capacity ratio), the importance of conductive carbon and binder, type of pan used, DSC ramp rate, and integration method used when dealing with broad and overlapping exothermic peaks. This work deepens the scientific basis and best practices for obtaining heat flow data from ACE samples for early-stage evaluation of solid-state and beyond battery safety.

25 ENERGY STORAGE↗

Mapping of lanthanide-tagged proteins on western blot paper using microextraction-inductively coupled plasma-mass spectrometry

A microextraction (ME) sampling system, paired with inductively coupled plasma-mass spectrometry (ICP-MS), was employed to spatially analyze proteins tagged with lanthanum (La), gadolinium (Gd), or terbium (Tb) on the surface of western blot paper. The proteins were covalently tagged, separated via gel electrophoresis, and transferred to western blot paper for analysis by ME-ICP-MS. The ME-ICP-MS method enables the direct sampling of the tagged species on the western blot paper, without any sample preparation. Traditionally, the tagged analyte would need to be stained, excised, and digested to be analyzed by ICP-MS for its elemental and isotopic characterization. Preliminary detection limits for the ME-ICP-MS method applied to western blot paper were established to be 564, 54, and 2.5 fg for La, Gd, and Tb, respectively. The developed ME-ICP-MS method was compared to laser ablation (LA) ICP-MS, another direct solid sampling technique; it was readily determined that ME-ICP-MS can effectively map the elemental constituents on the western blot paper with comparable analysis time and measurement sensitivity. The analysis time per 2 × 4 mm extraction is ∼1 minute; if protein spots are directly targeted (rather than systematically mapping the entire blot paper), the analysis time per protein spot is ∼1 min. This developed method proved to be fast, effective, and accessible for correlating protein molecular weight with the detection of the inorganic tagant. The ME-ICP-MS approach could be widely applicable in research areas that involve metal-tagged protein bioconjugates, such as in the development of diagnostic and therapeutic agents and other biochemical probes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Micro-tensile characteristics of As-fabricated and irradiated AGR-2 TRISO fuel particle buffer, IPyC, and buffer-IPyC interlayer regions

A recently developed micro-tensile sample preparation technique was implemented to evaluate the tensile strengths of the buffer, IPyC, and buffer-IPyC interlayer regions of the unirradiated and irradiated AGR-2 TRISO fuel particles. Understanding the mechanical properties of the buffer-IPyC interlayer is essential for developing thermomechanical models of buffer-IPyC separation, yet there is a lack of experimental data on its micro-tensile properties. TEM analysis was conducted on these regions to determine the microstructural changes relevant to the samples' tensile properties. In the unirradiated TRISO particle samples, the buffer layer demonstrated the weakest tensile strength, while the IPyC layer exhibited the highest. Conversely, in the irradiated TRISO particle samples, the buffer-IPyC interlayer region showed the lowest tensile strength, with the IPyC layer being the strongest. Fractures in the samples from the buffer-IPyC region predominantly occurred either in the buffer layer or at the buffer-IPyC interface. However, some buffer-IPyC interlayer samples displayed stress-strain and fracture behaviors more akin to the IPyC layer than the buffer layer. Analysis of diffraction patterns suggests that irradiation may have increased anisotropy in the three regions tested. Despite this suggested increase in anisotropy, there was no evidence that it affected the measured strengths. The irradiated TRISO particles demonstrated a considerable increase in void space and a decrease in ultimate tensile strength within the buffer-IPyC interlayer region due to the densification and contraction of the buffer layer. Minor variations in diffraction ring patterns were also observed. These changes, coupled with a significant reduction in the Weibull modulus/shape parameter, imply that irradiation-induced densification leads to tearing between the buffer and IPyC layers at locations of elevated porosity in the buffer-IPyC interlayer region.

Tristructural isotropic (TRISO)↗

Rapid 235 U/ 238 U determination by matrix assisted ionization–time-of-flight mass spectrometry

Matrix-assisted ionization (MAI) of inorganic analytes is a nascent research domain that holds promise for rapid, potentially facility-deployable analytical applications. Here, we present results of MAI uranium isotopic analysis ( 235 U/ 238 U) obtained on the timescale of minutes utilizing simple sample preparation and an ambient ionization time-of-flight mass spectrometer (ToF MS). Experimental MAI-ToF MS characterization of uranium Certified Reference Materials (CRMs) was used to establish method calibration and validate quantitative 235 U/ 238 U determination spanning depleted, natural, and low-enriched uranium isotopic compositions. Secondary standard analyses with total uranium mass loadings of 5–500 ng per analysis yield accurate calibrated 235 U/ 238 U results and relative uncertainties of 4.7–17.2% (approx. ±95% confidence level), with weighted-mean uncertainties approaching 1.5%. This method permits accurate determination of uranium isotopic composition in a sample with uranium content as low as 200 pg for equal atom 235 U: 238 U. Instrument detection limits constrain the minimum uranium mass required to identify the presence of highly enriched uranium (HEU ≥20% 235 U) as only 500 pg using the method presented here. MAI-ToF MS quantitation of relatively extreme isotope ratios ( 235 U/ 238 U ≤ 0.01) is limited by detection of minor 235 U (LoD 100 pg 235 U/analysis ≈ 10 ng total U/analysis), and subsequent method optimization is anticipated to further reduce these limits. These findings underscore the potential of MAI-ToF MS for isotopic characterization of uranium and other inorganic species for both basic and applied science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

OzMALDI: A Gas-Phase, In-Source Ozonolysis Reaction for Efficient Double-Bond Assignment in Mass Spectrometry Imaging with Matrix-Assisted Laser Desorption/Ionization

Lipids make up an important class of biomolecules with diverse structures and varied chemical functions. This diversity is a major challenge in chemical analysis and limits our understanding of biological functions and regulation. A major way lipid isomers differ is by double-bond (db) position, and analyzing db-isomers is especially challenging for mass spectrometry imaging (MSI). Ozonolysis can be used to determine the dbposition and has been paired with MSI before. However, previous techniques require increased analysis time to allow for gas-phase reactions within an ion trap or ion mobility cell or additional sample preparation time to allow for offline ozonation. Here, we introduce a new ozonolysis method inside the matrix-assisted laser desorption-ionization (MALDI) source, termed OzMALDI, that simultaneously produces ozonides from all unsaturated lipids. This allows us to determine db-positions without adding additional reaction time while maintaining the high mass resolution provided by Orbitrap MS. This new technique is especially effective at determining multiple db-positions in lipids containing polyunsaturated fatty acids, which is a limitation of many previous techniques. OzMALDI-MSI was applied to the analysis of rat brain and genetically engineered Camelina and soybean seed samples, demonstrating the utility of this method and uncovering novel biological information.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transformative Impacts of Laser-Induced Breakdown Spectroscopy on Environmental and Biological Research at Oak Ridge National Laboratory

This manuscript will present an advancement of transformative research that has been conducted at Oak Ridge National Laboratory (ORNL) over a 25-year period (2000–2025) on a variety of environmental and biological matrices. These investigations derived a fundamental understanding of how elemental detection and analysis of these matrices led to the knowledge and discovery of natural processes in plants and the environment. Each project led to the initiation of a new research area which unearthed awesome and novel breakthroughs. Highlights are listed below: 1. The preliminary research at ORNL centered on the detection of aerosols utilizing Laser-induced Breakdown Spectroscopy (LIBS) technology. The Clean Air Act Amendment (CAAA) of 1990 highlighted the importance of identifying hazardous air pollutants (HAPs) due to their impact on environmental and human health, thereby underscoring the need to detect various toxic elements. Research in aerosol chemistry aimed to identify these harmful elements released by factories during periods of increased emissions in their manufacturing processes. LIBS emerged as the most effective method for real-time, in situ measurements of metal species in both gaseous and aerosol phases. 2. An understanding of the presence of total carbon in soils gives perspective on how to develop carbon sequestration strategies. The recognition that carbon sinks can evolve back to carbon sources to emit back to the atmosphere was an important consideration. Also, the concentration of carbon in soil indicates the health of land areas for growing crops successfully. 3. The direct detection of most of the elements in a wood sample in a single emission spectrum, without sample preparation, encouraged the research to use the LIBS technique for preservative treated wood coupled with use of multivariate statistical methodology. Additionally, it encouraged the researchers to try to differentiate natural woods from different parts of the country, and it was successfully demonstrated that LIBS coupled with MVA analysis could differentiate wood of different species from each other and of similar species grown in different environments based on their elemental spectra. This was a breakthrough since it revealed a systematic approach to connect elemental scarcity and abundance to either drought or typical rainfall conditions for the hardwood trees grown in specific areas. 4. Furthermore, the research progressed to reveal physiological and developmental processes contributing to biomass production such that the variation in leaf elemental composition increases our understanding of terrestrial nutrient cycles, as well as tracking the transfer of toxic elements from soils to living organisms. 5. Recently another breakthrough viz., ionomics initiated the correlation of elements to specific genes, uncovering the function that the element performed in the plant. More recently, this has been extended from plants to fungi as well as fungi growing in symbiotic relations with plants.

09 BIOMASS FUELS↗

Simultaneous Determination of Halogens and Metals in Waste Plastic Pyrolysis Oil by Inductively Coupled Plasma Mass Spectrometry

A major barrier to integrating pyrolysis-derived oil into conventional refinery technology is the presence of impurities, particularly halogens and metals, that can deactivate catalysts. This study presents a novel, cost-effective approach for the simultaneous analysis of a subset of halogens, metals, nonmetals, and metalloids in complex, industrially relevant distilled pyrolysis oil samples, this was previously achievable only through multiple techniques. Excellent results were obtained using a widely accessible inductively coupled plasma mass spectrometry (ICP-MS) method with helium gas mode and standard laboratory consumables, enabling high-throughput analysis and efficient evaluation of adsorbent performance. Sample preparation is straightforward, requiring only dilution in a compatible matrix, and provides accurate and precise quantification, with 75%–137% spike recovery for Be, Ti, V, Cr, Fe, Ni, Co, Cu, As, Se, Mo, Cd, Sb, Tl, and Pb, and 62%–65% spike recovery for Cl and 109%–133% spike recovery for Br. Additionally, an enhanced version of the method using ICP-MS/MS and hydrogen gas is described, which has higher accuracy with 69%–112% spike recovery for Be, B, Ti, V, Fe, Co, Ni, Cu, As, Se, Mo, Cd, Sb, Tl, and Pb, with 85%–102% spike recovery for Cl and 63%–93% spike recovery for Br. Helium mode detection limits for industrially relevant elements (V, Fe, Ni, Cu, As, and Pb) are less than 1.7 µg/kg, and less than 0.2 mg/kg for Br and Cl. Furthermore, this methodology facilitates rapid systematic evaluation of adsorption capacities of materials under time-on-stream conditions and supports robust comparisons across diverse operating environments.

Lazarcik, James [University of Wisconsin-Madison, ↗

The microbiologist's guide to metaproteomics

Metaproteomics is an emerging approach for studying microbiomes, offering the ability to characterize proteins that underpin microbial functionality within diverse ecosystems. As the primary catalytic and structural components of microbiomes, proteins provide unique insights into the active processes and ecological roles of microbial communities. By integrating metaproteomics with other omics disciplines, researchers can gain a comprehensive understanding of microbial ecology, interactions, and functional dynamics. This review, developed by the Metaproteomics Initiative (www.metaproteomics.org), serves as a practical guide for both microbiome and proteomics researchers, presenting key principles, state-of-the-art methodologies, and analytical workflows essential to metaproteomics. Topics covered include experimental design, sample preparation, mass spectrometry techniques, data analysis strategies, and statistical approaches.

bioinformatics↗

Extrusion‐Spheronization of Energetic Materials

The prevailing method to produce plastic‐bonded explosive (PBX) molding powder, or “prills”, is a complex, multiphase, and bespoke process that was developed by the high explosives (HEs) manufacturing industry several decades ago. This work demonstrates the utility of a simpler, widely‐used mechanical process—extrusion‐spheronization—to produce PBX prills. We begin by detailing precautions taken to enable safe remote operation of extrusion‐spheronization equipment with HE. We then perform a study investigating the effect of lacquer solvent composition on the particle packing, pressed density, and compressive strength properties of a 95 wt.% TATB/5 wt.% polymer binder formulation akin to PBX 9502. It was found that increased composition of low vapor pressure solvents caused prolonged retention of the solvent, resulting in tackier materials that would agglomerate and form larger prills. The larger prills also led to lower poured density and tapped density of HE prills and compressive strength of pressed PBX articles. The samples prepared with a 75% propyl acetate/25% butyl acetate lacquer solvent composition exhibited the highest compressive strength. However, it is believed that the prill packing and compressive strength properties are primarily driven by the prill size rather than the chemical composition of the lacquer itself. Extrusion‐spheronization remains a promising method to reliably and repeatably produce HE prills that is less sensitive to feedstock or process variation than traditional methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating inkjet dispenser/liquid vortex capture-mass spectrometry for single-cell metabolomics in Hep G2 steatosis caused by tamoxifen

Single-cell mass spectrometry (MS) is advancing our understanding of metabolic pathways in heterogeneous cell populations; however, many techniques are slow or require disruptive sample preparations. This study evaluated coupling a modified HP D100 single-cell inkjet dispenser with liquid vortex capture-mass spectrometry (D100/LVC-MS). The D100 is a single-cell inkjet dispenser capable of titrating solutions and isolating single cells via disposable cassettes equipped with microfluidic channels and an impedance sensor. The LVC-MS enables high-throughput capture, lysis, and ionization of analytes for mass spectrometric analysis. The D100/LVC-MS system was characterized through titration and single-cell experiments. Propranolol titration demonstrated linearity across a broad concentration range using the D100/LVC-MS system. Additionally, Hep G2 hepatocarcinoma cells and Chlamydomonas reinhardtii algae were used to showcase the D100’s high-throughput or low-buffer-volume single-cell dispensing strategies. The D100/LVC-MS system’s performance was validated by evaluating tamoxifen-induced steatosis in Hep G2 cells. Tamoxifen, associated with nonalcoholic fatty liver disease in breast cancer patients following long-term use, was tested in Hep G2 cells at 20 µM for 72 h against DMSO-treated controls. High-throughput analysis of 500 cells per condition, completed in 25 min per run, demonstrated the system’s efficiency. The D100/LVC-MS system simultaneously quantified tamoxifen and measured triglycerides and phosphatidylcholines. Triglycerides were upregulated in the tamoxifen-treated cells and the results indicated two distinct cell populations, differing in tamoxifen and phosphatidylcholines levels, suggesting heterogeneity within the treated population. In conclusion, these findings highlight the D100/LVC-MS system as a cost-effective, high-throughput platform for single-cell metabolomics and lipidomics, with significant potential for evaluating metabolic alterations.

Chromatography↗

Sample screening of uranium ore concentrates using portable spectrophotometers: investigating the correlation between visible colors and chemical signatures

A research collaboration between the Japan Atomic Energy Agency and the Department of Energy’s National Nuclear Security Administration examined nuclear forensic signatures and analytical methods for tracing the origins of uranium ore concentrates (UOCs). Here, this study focuses on utilizing portable spectrophotometers capable of reflectance measurements in the visible light spectrum as a potential rapid screening tool for nuclear forensics analysis. Unlike laboratory-based near-infrared spectroscopy or digital image analysis, this research investigated the potential to correlate visible color measurements with key nuclear forensics signatures using seven types of UOC samples with known origins and three UOC certified reference materials. Results demonstrated that distinct color groups, quantified using CIELAB values, correlated with major uranium compounds. Furthermore, the findings indicated that trace elements can influence the UOC colors, providing additional insights into material characteristics. Although this approach requires further validation across a broader range of UOC species, this study demonstrated that simple colorimetric analysis using visible spectrophotometry, which does not require complex sample preparation or data processing, can serve as a practical and novel rapid tool for preliminary screening and attribution in nuclear forensics investigations.

and nuclear chemistry↗

Interlaboratory comparison of secondary ion mass spectrometry analysis results from the 7th international technical nuclear forensics working group collaborative material exercise

A review and interlaboratory comparison of secondary ion mass spectrometry (SIMS) data obtained by laboratories participating in the International Technical Nuclear Forensics Working Group (ITWG) 7th Collaborative Material Exercise (CMX-7) has been conducted. The analyzed materials were two uranium compounds in powder form and two pieces of uranium metal. The instruments used in this comparison were a small-geometry (SG) SIMS, CAMECA IMS 7f from the Research Centre Rez, and a large-geometry (LG) SIMS, CAMECA IMS 1280 from Los Alamos National Laboratory. Despite the differences in instruments and analytical procedures, e.g., sample preparation, SIMS setups, and data post-processing, there was good agreement for the 234 U/ 238 U, 235 U/ 238 U, and 236 U/ 238 U ratios in the analyzed materials. The main difference was in the precision, which was, as expected, higher for the LG-SIMS. In addition, a comparison between the laboratories was also made for the image processing algorithms applied to raw data acquired in automated particle measurement (APM) mode. In conclusion, the result of this comparison has led to identification of best practices for setting up parameters of the APM software.

and nuclear chemistry↗

Review: Recent advances of ToF-SIMS for environmental analysis and imaging

Background: Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a powerful surface analysis technique, initially developed and applied in inorganic materials and semiconductors. In past decades, ToF-SIMS has attracted more attention in its analysis capabilities of organic materials, with increased applications in biology, medical, and health development. It has also become a versatile and effective tool in environmental analysis due to its high mass resolution, mass accuracy, and depth profiling. Results: In this review, we first give an overview of the principle of ToF-SIMS and follow with recent ToF-SIMS applications in exemplary environmental study cases, including atmospheric aerosol, soil, water, plant, and organic solvent analysis. Moreover, sample preparation techniques are summarized in relation to corresponding environmental applications. Specifically, we call attention to ToF-SIMS investigations showcasing studies in surface chemical compositions, images, and depth profile analysis. These findings emphasize the important role of interfacial chemistry in environmental processes and provide valuable insights into dynamic processes, such as chemical transformation, particle formation, plant biology, and microbial inspired biotechnology development. The mass spectral imaging results acquired by ToF-SIMS offer a deeper understanding of intermediate stages and transient phases for environmental specimens. Significance: In situ and operando imaging offer new possibilities in studying phenomena in real time with high spatial resolution. Furthermore, it is anticipated that more research groups will use ToF-SIMS in environmental research given recent advances in measurement capabilities and surging needs in chemical mapping of complex analytes and systems.

Aerosol↗

Near-infrared spectroscopy as a green analytical tool for sustainable biomass characterization for biofuels and bioproducts: An overview

Biomass, a widely used renewable energy source, requires characterization to optimize biofuel and bioproduct processes, customize feedstocks, and ensure economic and environmental sustainability. Conventional wet-chemistry methods for biomass analysis are slow, expensive, and require significant reagents and skilled personnel. In contrast, near-infrared (NIR) spectroscopy, a faster, cost-effective, and reagent-free green technology, enables non-destructive biomass analysis with minimal sample preparation. This study provides an overview of the fundamentals of NIR spectroscopy and explores its recent applications for analyzing various biomass properties important to the biofuel and bioproduct industry. The study also critically evaluates the challenges and opportunities of using NIR spectroscopy for biomass analysis. This review aims to guide future research for rapid and high throughput characterization of biomass in the biomass industry, supporting the United Nations’ sustainable development goal (SDG) 7: producing affordable and sustainable energy.

Biofuels↗

Mechanochemical synthesis of hydraulically reactive calcium silicate minerals via thermally-assisted mechanical grinding

This study explores a thermally assisted mechanochemical approach alternative to conventional cement synthesis as a potential to produce hydraulically reactive calcium silicate phases. Ball milling of mixed CaO/SiO 2 feedstocks at temperature ranges 100-300 °C increases the formation of the Ca-O-Si bonds and precursor reactivity. Spectroscopic analyses (FTIR, MAS-NMR, UV-Vis DRS) indicate increasing amorphization with milling temperature, attributed to improved mixing and thermally assisted diffusion. Upon hydration, all treated samples exhibit exothermic heat release, with the sample prepared at 300 °C showing the most pronounced reactivity. Thermal analysis reveals weight loss consistent with C-S-H formation, confirming cement-like behavior. In summary, moderate thermal input during milling promotes structural activation and enhances downstream hydraulic reactivity, providing a proof-of-concept for energy-reduced cement precursor processing.

Alite↗

Synergistic Effects of Molten Salt Corrosion and Proton Irradiation on Grain Boundary Strength in Ni-20Cr

Nickel-based alloys are leading contenders for use as structural materials in molten salt reactors. While there have been extensive studies on the impact of fluoride/chloride-based molten salt corrosion on the microstructural evolution of various nickel-based alloys, the effects of simultaneous molten salt corrosion and radiation on the mechanical integrity of grain boundaries (GBs) remain underexplored. In this study, we use a Ni-20Cr model alloy to investigate this issue, subjecting it to simultaneous molten fluoride salt corrosion and proton irradiation. We performed cross-sectional and chemically-sensitive electron microscopy characterization of the microstructures of these materials, identifying the characteristic corrosion-induced microstructure and local chemical heterogeneity near GBs. After developing a sample preparation method for reliable characterization of GB strength, we assess the mechanical degradation of GBs using in situ push-to-pull micro tensile tests. Our findings reveal that voids induced by corrosion are the primary influence on the failure mode of GBs, regardless of whether proton irradiation is present. For materials that exhibit ductile fracture, those subjected to simultaneous corrosion and radiation exhibit lower yield strengths than those exposed to corrosion alone, which may be linked to the previously observed phenomenon of proton irradiation-decelerated intergranular corrosion in molten salt.

36 - MATERIALS SCIENCE↗

Creep suppression and fatigue in bio-based composites manufactured via conventional and large format additive manufacturing processes

The emergence of novel extrusion-based additive manufacturing (AM) processes has prompted the development of new thermoplastic composite feedstocks, and broadening sustainability initiatives have driven the development of bio-based and recyclable material for AM feedstocks. Poly(lactic acid) (PLA) with wood flour (WF) is one composite system that has been demonstrated in numerous AM applications, as well as traditional processing methods (i.e., compression and injection molding); however, there has been a need to understand how the variation in processing methodology impacts the material performance of these bio-based feedstocks from a fundamental perspective, with particular emphasis on creep for an extended application use-life. Herein, PLA/WF is explored as a feedstock material for large format additive manufacturing (LFAM) and the performance of additively manufactured materials is compared to those produced via more traditional processing methods. It is also demonstrated that the addition of WF decreases the material’s coefficient of thermal expansion (CTE) while increasing its Young’s modulus, susceptibility to water uptake, and creep fatigue resistance. Essentially, the addition of 20 wt% WF results in a 92 % decrease in rubbery regime CTE while simultaneously resulting in a 14 % increase in modulus, 190 % increase in water uptake, and a 31 % decrease in residual strain after cyclic creep tests. The processing method was also found to play a large role in the final part performance, with the printed material increasing the crystallinity by 183 % and 214 % compared to its compression and injection molded counterparts. Furthermore, the porosity of printed samples increased by two orders of magnitude compared to samples prepared via traditional processing methods.

36 MATERIALS SCIENCE↗

Ionic Liquids in Analytical Chemistry: Fundamentals, Technological Advances, and Future Outlook

The development of new analytical methods most often focus on novel materials used to impart selectivity or sensitivity to the protocol. Ionic liquids (ILs) are a class of solvents that have been extensively explored as promising materials for various applications and continue to be explored due to their tunable physicochemical properties. These materials possess melting temperatures below 100 °C and can interact with analytes through a multitude of interactions afforded by their readily tunable chemical structure. These interactions include electrostatic, dispersive, hydrogen bonding, π–π, and dipolar interactions and can be modulated or strengthened based on the functional groups present within the chemical structure. ILs consist predominately of organic cations and either inorganic or organic anions, both of which can be functionalized with desired moieties. Common cation and anions found in IL chemical structures are presented in Figure 1. The unique polarity afforded by the ionic structure has also led to their increasing use in areas including sample preparation, chemical separations, electrochemistry, mass spectrometry, and spectroscopy.

Zeger, Victoria R. [Iowa State Univ., Ames, IA (Un↗