At least 73 records · Page 4

A Backscatter Moessbauer Spectrometer (BaMS) for use on Mars

The use of Moessbauer spectroscopy for in situ analysis on the surface of Mars was proposed and the design and implementation of a backscatter Moessbauer spectrometer (BaMS) instrument suitable for planetary missions to the surfaces of Mars (MESUR), the Moon (Artemis and lunar outpost), asteroids, or other solid solar system objects is discussed. The BaMS instrument is designed to be capable of analysis of a sample for the mineralogy of its iron-bearing phases without any sample preparation. A requirement of lander missions to Mars is instrumentation for in situ mineralogical analyses. Such analyses provide data needed for primary characterization as to the type of surface materials present and by inference the processes that formed and subsequently modified them. For purposes of providing diagnostic information about naturally occurring materials, the element iron is particularly important because it is abundant and multivalent (primarily 0, +2, and +3 oxidation states). Knowledge of the oxidation state of iron and its distribution among iron-bearing mineralogies tightly constrains the types of materials present. The pivotal role of iron was already recognized in 1978 by COMPLEX, who recommended development of flight instruments that would identify mineralogy and the oxidation state of iron in planetary surface materials. The near-term U.S. strategy for the exploration of Mars is the MESUR (Mars Environmental SURvey) program, which entails emplacement of a network of small, long-lived surface landers. For the Moon, BaMS was recommended as part of a three-instrument landed payload for the Artemis missions, targeted for 1997. BaMS would prospect for ilmenite, an oxygen resource material, and provide data to assess the maturity of lunar soil. Because instrumental characteristics are low mass, low volume, and low power consumption, BaMS is suitable for implementation on even small landers and rovers, as are being envisioned in MESUR and Artemis concepts. In addition to providing highly diagnostic data, a BaMS analyzer is inherently simple and, as is highly desirable for remote operation, no sample preparation is required.

Agresti, D. G.↗

Preliminary design polymeric materials experiment

A typical Advanced Technology Laboratory mission flight plan was developed and used as a guideline for the identification of a number of experiment considerations. The experiment logistics beginning with sample preparation and ending with sample analysis are then overlaid on the mission in order to have a complete picture of the design requirements. The results of this preliminary design study fall into two categories. First specific preliminary designs of experiment hardware which is adaptable to a variety of mission requirements. Second, identification of those mission considerations which affect hardware design and will require further definition prior to final design. Finally, a program plan is presented which will provide the necessary experiment hardware in a realistic time period to match the planned shuttle flights. A bibliography of all material reviewed and consulted but not specifically referenced is provided.

Mattingly, S. G.↗

Artemis Curation: Preparing for Sample Return from the Lunar South Pole

Space Policy Directive-1 mandates that “the United States will lead the return of humans to the Moon for long-term exploration and utilization, followed by human missions to Mars and other destinations.” In addition, the Vice President stated that “It is the stated policy of this administration and the United States of America to return American astronauts to the Moon within the next five years,” that is, by 2024. These efforts, under the umbrella of the recently formed Artemis Program, include such historic goals as the flight of the first woman to the Moon and the exploration of the lunar south-polar region. Among the top priorities of the Artemis Program is the return of a suite of geologic samples, providing new and significant opportunities for progressing lunar science and human exploration. In particular, successful sample return is necessary for understanding the history of volatiles in the Solar System and the evolution of the Earth-Moon system, fully constraining the hazards of the lunar polar environment for astronauts, and providing the necessary data for constraining the abundance and distribution of resources for in-situ resource utilization (ISRU). Here we summarize the ef-forts of the Astromaterials Acquisition and Curation Office (hereafter referred to as the Curation Office) to ensure the success of Artemis sample return (per NASA Policy Directive (NPD) 7100.10E).

Mitchell, J. L.↗

Recommended practices for in-space and ground laboratory. Atomic oxygen exposure and analysis

A detailed guide to testing materials for atomic oxygen durability in earth orbit environments is presented. The steps covered include sample preparation, including masking of the sample, dehydration, weighing, and handling; effective fluence prediction, including the use of witness samples (notably Kapton); plasma facility and operational considerations, involving such matters as avoidance of silicone contamination, the use of continuous versus incremental ashing, and temperature of operation; and erosion yield measurement, with calculation methods and protective coating performance indices provided.

Banks, Bruce↗

TEM Analysis of Diffusion-Bonded Silicon Carbide Ceramics Joined Using Metallic Interlayers

SiC fiber-bonded ceramics (SA-Tyrannohex: SA-THX) diffusion-bonded with TiCu metallic interlayers were investigated. Thin samples of the ceramics were prepared with a focused ion beam (FIB) and the interfacial microstructure of the prepared samples was studied by transmission electron microscopy (TEM) and scanning TEM (STEM). In addition to conventional microstructure observation, for detailed analysis of reaction compounds in diffusion-bonded area, we performed STEM-EDS measurements and selected area electron diffraction (SAD) experiments. The TEM and STEM experiments revealed the diffusion-bonded area was composed of only one reaction layer, which was characterized by TiC precipitates in Cu-Si compound matrix. This reaction layer was in good contact with the SA-THX substrates, and it is concluded that the joint structure led to the excellent bonding strength.

Ceramics↗

New Material for Surface-Enhanced Raman Spectroscopy

A chemical method of synthesis and application of coating materials that are especially suitable for surface-enhanced Raman spectroscopy (SERS) has been developed. The purpose of this development is to facilitate the utilization of the inherently high sensitivity of SERS to detect chemicals of interest (analytes) in trace amounts, without need for lengthy sample preparation. Up to now, the use of SERS has not become routine because the methods available have not been able to reproduce sampling conditions and provide quantitative measurements. In contrast, the coating materials of the present method enable analysis with minimum preparation of samples, and SERS measurements made using these materials are reproducible and reversible. Moreover, unlike in methods investigated in prior efforts to implement SERS, sampling is not restricted to such specific environments as electrolytes or specific solvents. The coating materials of this method are porous glasses, formed in sol-gel processes, that contain small particles of gold or silver metal. Materials of this type can be applied to the sample-contact surfaces of a variety of sampling and sensing devices, including glass slides, glass vials, fiber-optic probes, and glass tubes. Glass vials with their insides coated according to this method are particularly convenient for SERS to detect trace chemicals in solutions: One simply puts a sample solution containing the analyte(s) into a vial, then puts the vial into a Raman spectrometer for analysis. The chemical ingredients and the physical conditions of the sol-gel process have been selected so that the porous glass formed incorporates particles of the desired metal with size(s) to match the wavelength(s) of the SERS excitation laser in order to optimize the generation of surface plasmons. The ingredients and processing conditions have further been chosen to tailor the porosity and polarity of the glass to optimize the sample flow and the interaction between the analyte(s) and the plasmon field that generates Raman photons. The porous silica network of a sol-gel glass creates a unique environment for stabilizing SERS-active metal particles. Relative to other material structures that could be considered for SERS, the porous silica network offers higher specific surface area and thus greater interaction between analyte molecules and metal particles. Efforts to perform SERS measurements with the help of sampling devices coated by this method have been successful. In tests, numerous organic and inorganic chemicals were analyzed in several solvents, including water. The results of the tests indicate that the SERS measurements were reproducible within 10 percent and linear over five orders of magnitude. One measure of the limits of detectability of chemicals in these tests was found to be a concentration of 300 parts per billion. Further development may eventually make it possible to realize the full potential sensitivity of SERS for detecting some analytes in quantities as small as a single molecule.

Farquharson, Stuart↗

Galvanic Corrosion In (Graphite/Epoxy)/Alloy Couples

Effects of galvanic coupling between graphite/epoxy composite material, G/E, and D6AC steel, 6061-T6 aluminum, and Inconel(R) 718 nickel alloy in salt water described in report. Introductory section summarizes previous corrosion studies of G/E with other alloys. Details of sample preparation presented along with photographs of samples before and after immersion.

Danford, Merlin D.↗

TEM Observation of the Ti Interlayer Between SiC Substrates During Diffusion Bonding

Diffusion bonding was carried out to join SiC to SiC substrates using titanium interlayers. In this study, 10 m and 20 m thick physical vapor deposited (PVD) Ti surface coatings, and 10 and 20 m thick Ti foils were used. Diffusion bonding was performed at 1250 C for PVD Ti coatings and 1200 C for Ti foil. This study investigates the microstructures of the phases formed during diffusion bonding through TEM and selected-area diffraction analysis of a sample prepared with an FIB, which allows samples to be taken from the reacted area. In all samples, Ti3SiC2, Ti5Si3Cx and TiSi2 phases were identified. In addition, TiC and unknown phases also appeared in the samples in which Ti foils were used as interlayers. Furthermore, Ti3SiC2 phases show high concentration and Ti5Si3Cx formed less when samples were processed at a higher temperature and thinner interlayer samples were used. It appears that the formation of microcracks is caused by the presence of intermediate phase Ti5Si3Cx, which has anisotropic thermal expansion, and by the presence of an unidentified Ti-Si-C ternary phase with relatively low Si content.

Tsuda, Hiroshi↗

Prebiotic Polymer Synthesis and the Origin of Glycolytic Metabolism

Our research resulted in several discoveries which contributed to understanding the origin and operation of life. (1) Most importantly, we discovered a new pathway of prebiotic amino acid synthesis in which formaldehyde and glycolaldehyde (formose reaction substrates) react with ammonia to give alanine and homoserine in the presence of thiol catalysts. The thiol-dependent synthesis of amino acids undoubtedly occurs via amino acid thioester intermediates capable of forming peptides. This 'one-pot' reaction system operates under mild aqueous conditions, and like modern amino acid biosynthesis, uses sugar intermediates which are converted to amino acids by energy-yielding redox disproportionation. Preliminary evidence suggests that this type of process can be "evolved" by a serial transfer methods that lead to enrichment of autocatalytic molecules. (2) We established that prebiotic peptide polymers can be made by condensation of amino acid thioesters (homocysteine thiolactone and S-(N-beta-orotidyl- diaminopropionic acid) ethanethiol), and that prebiotic polydisulfide polymers can be generated by oxidation of dithiols with iron(III) in minerals. (3) In our analysis of metabolism we discovered the primary energy source of biosynthesis -- chemical energy made available by the redox disproportionation of substrate carbon groups. We concluded that the energy and reactivity of sugars make them the optimal substrate for the origin and operation of terrestrial (or extraterrestrial) life. (4) Since it is likely that the use of optimal sugar substrates in biosynthesis sets the average oxidation number of functional biocarbon throughout the Universe near 0.0 (the reduction level of formaldehyde), we proposed that a line(s) in the microwave spectrum of formaldehyde could be rationally selected as a frequency for interstellar communication that symbolizes life. (5) Finally, in preparation for the analysis of Martian meteorite samples, we upgraded our HPLC system to one femtomole sensitivity, and developed a new electrophoretic method of sample preparation for HPLC analysis of the meteoritic amino acids. In a sample of the KT boundary layer from Sussex Wyoming, we found about 300 picomoles per gram of meteoritic alpha-aminoisobutyric acid per gram of KT layer.

Weber, Arthur L.↗

Ramdb: The NASA Raman Spectral Database (version 1.00).

Given that, in most instances, minimal sample preparation is required and due to its contactless instrument design, Raman spectroscopy is one of the most versatile vibrational spectroscopic techniques for the chemical analysis of environmental and biological specimens. The diversity of applications of Raman spectroscopy ranges anywhere from art [1] to planetary science missions [2]. The advancement in the use of Raman spectroscopy in Solar System missions, notably in post-mission sample return analysis, requires a spectral library holding the broad range of specimens that could be found in Solar System sources. For this purpose, we have initiated the development of a Raman spectral database (Ramdb) at NASA Ames Research Center. Currently, the database includes experimental and theoretical Raman spectra of PAHs [3, 4], as well as laboratory Raman spectra of amino acids, carbon allotropes, minerals, and analogs relevance to Earth Sciences [5], Exobiology [6], Planetary [7], and Astrochemistry [8] to name just a few examples. Ramdb can be found on the web at www.astrochemistry.org/ramdb, where raw and processed Raman spectra can be downloaded in CSV format. The laboratory Raman spectra are measured using a laser Raman spectrometer (JASCO NRS-5500-532QRI). The Raman instrument is equipped with three excitation lasers, with wavelengths of 405, 532, and 785 nm. A clean silicon substrate is used as the internal standard for wavenumber calibration. Powdered samples were prepared (microscopic >10 um, grounded microscopic < 10 um) on glass slides. Some raw data exhibited a background signal arising as a combination of laser-induced fluorescence from the sample. To correct this background, we developed a Python pipeline that uses open-source Python libraries. Ramdb provides both raw and processed (using Python pipeline) data, which includes tabulated Raman shift transitions and other measurement details. The theoretical Raman band positions of PAHs (pyrene monomers and tetramer clusters) were computed using density functional theory (DFT) with the help of the Gaussian 16 suite of programs [9]. In the near future, Ramdb will serve as a repository of Raman spectral data from Laboratory Astrophysics and Planetary Science experiments involving the irradiation of organic compounds under simulated space and planetary conditions. In addition, online and offline tools will be developed for utilising the database for comparison to the user’s sample.

N Punnakayathil↗

Aqueous nitrite ion determination by selective reduction and gas phase nitric oxide chemiluminescence

An improved method of flow injection analysis for aqueous nitrite ion exploits the sensitivity and selectivity of the nitric oxide (NO) chemilluminescence detector. Trace analysis of nitrite ion in a small sample (5-160 microL) is accomplished by conversion of nitrite ion to NO by aqueous iodide in acid. The resulting NO is transported to the gas phase through a semipermeable membrane and subsequently detected by monitoring the photoemission of the reaction between NO and ozone (O3). Chemiluminescence detection is selective for measurement of NO, and, since the detection occurs in the gas-phase, neither sample coloration nor turbidity interfere. The detection limit for a 100-microL sample is 0.04 ppb of nitrite ion. The precision at the 10 ppb level is 2% relative standard deviation, and 60-180 samples can be analyzed per hour. Samples of human saliva and food extracts were analyzed; the results from a standard colorimetric measurement are compared with those from the new chemiluminescence method in order to further validate the latter method. A high degree of selectivity is obtained due to the three discriminating steps in the process: (1) the nitrite ion to NO conversion conditions are virtually specific for nitrite ion, (2) only volatile products of the conversion will be swept to the gas phase (avoiding turbidity or color in spectrophotometric methods), and (3) the NO chemiluminescence detector selectively detects the emission from the NO + O3 reaction. The method is free of interferences, offers detection limits of low parts per billion of nitrite ion, and allows the analysis of up to 180 microL-sized samples per hour, with little sample preparation and no chromatographic separation. Much smaller samples can be analyzed by this method than in previously reported batch analysis methods, which typically require 5 mL or more of sample and often need chromatographic separations as well.

NASA Discipline Environmental Health↗

NM-Scale Anatomy of an Entire Stardust Carrot Track

Comet Wild-2 samples collected by NASA s Stardust mission are extremely complex, heterogeneous, and have experienced wide ranges of alteration during the capture process. There are two major types of track morphologies: "carrot" and "bulbous," that reflect different structural/compositional properties of the impactors. Carrot type tracks are typically produced by compact or single mineral grains which survive essentially intact as a single large terminal particle. Bulbous tracks are likely produced by fine-grained or organic-rich impactors [1]. Owing to their challenging nature and especially high value of Stardust samples, we have invested considerable effort in developing both sample preparation and analytical techniques tailored for Stardust sample analyses. Our report focuses on our systematic disassembly and coordinated analysis of Stardust carrot track #112 from the mm to nm-scale.

Nakamura-Messenger, K.↗

Plasma-Based Elemental Analyzer for Crewed Transit and Planetary Habitation

As NASA continues to perform research on the ISS and move towards the Moon and Mars, it is important for astronauts to have a technology capable of determining the composition of solid, liquid, and gas samples. Currently, samples are transported back to Earth for analysis, which may impact results due to the time delay of samples waiting to be returned to Earth as well as potential sample contamination from re-entry, change in environment, and various personnel handling. Therefore, researchers at the Applied Chemistry Lab at KSC have developed a proof-of-concept “Plasma-Based Elemental Analyzer,” which has the capability of testing solid, liquid, and gas samples for identification. Currently, the analysis is only qualitative, with quantitative identification left for future work. This technology is similar to ICP-OES, but differs in instrument size and sample preparation. Both technologies use plasma to ionize samples for light emission. The plasma elemental analyzer aims to be portable and lightweight, require only electrical power, and analyze solid, liquid, and gas samples. It does not use acid digestion or a nebulizer, requires less power than ICP-OES, and is able to operate with minimal to no usage of argon gas. Furthermore, the plasma elemental analyzer operates within low power constraints, which makes it feasible for usage on future missions with higher power constraints. The technology was tested at atmospheric pressure using mostly room air as the carrier gas for plasma production in the proof-of-concept study. The results showed the peak signals of the elements with an associated arbitrary signal intensity that allowed for qualitative identification. Solid samples that were tested included inedible biomass from the Golden Heirloom Cherry Tomato plant and Lunar Highlands Simulants (LHS-1). The liquid samples included elements of interest for the space crop production community. This work showed that a system smaller than the traditional ICP-OES equipment is able to be designed and implemented in future use cases, although it requires further development.

Kenneth Engeling↗

Center for Isotope Cosmochemistry and Geochronology at NASA Johnson Space Center

Ten years in the making the Center for Isotope Cosmochemistry and Geochronology (CICG) at NASA Johnson Space Center is designed to be a cooperative analytical facility where novel techniques are developed and performed. Our team works collaboratively to operate this integrated lab suite comprising sample preparation, metal-free clean chemistry, and mass spectrometers to measure a wide variety of elements and isotopes in astromaterials. Contamination control is enacted throughout by a positive pressure cascade of HEPA filtered air, weekly surface cleaning and particle counting. Astromaterials processing is performed with application-specific mortar and pestles, heavy liquid separation, a Frantz magnetic separator, as well as hand-picking using optical microscopes in laminar flow boxes. Microsampling is also carried out using a New Wave MicroMill. Elements for isotopic analysis are isolated from acid-digested samples using ion-exchange chromatography. Cross-contamination is minimized with dedicated laminar flow boxes and labware for different purification protocols. Instrumentation includes a ThermoFisher Element XR inductively coupled plasma mass spectrometer (ICP-MS) for quantification of elemental concentrations in dissolved sample solutions. For in situ analysis, a Teledyne Photon Machines Analyte Excite+ laser ablation system is coupled to the Element XR. The ThermoFisher Triton thermal ionization mass spectrometer (TIMS) is used to measure the isotopic composition of elements such as CA, K, Cr, Rb, Sr, Sm, Nd at high precision in processed samples. For a more diverse range of isotopic analyses, CICG houses a Nu Sapphire 1700 multi-collector inductively coupled plasma mass spectrometer (MC-ICP-MS), which is a large geometry instrument with a multi-pole collision cell for interference removal. An Applied Spectra Instruments J200 femto-second laser is planned for install this Fall and will be coupled to the Nu Sapphire 1700. NASA’s Internal Scientist Funding Model (ISFM)supports this facility. Advanced analytical geochemistry techniques are applied to targeted astromaterials to address important problems in planetary sciences, with a longer-term goal of preparing for samples collected and returned by space missions. CICG is open to collaborations on projects that utilize the facility’s unique capabilities and are within its research scope. We are particularly eager to support and share expertise with the next generation of planetary scientists.

Justin I Simon↗

Effect of Vacuum on Force Response of an Ultrasonic Penetrator

Introduction: The Apollo astronauts encountered higher than expected resistances when interacting with the lunar soil via the Apollo Lunar Surface Drill (ALSD) and the trenching tool. Reducing the force required to move tools or other mechanical components through regolith will impact many steps of the resource extraction process. Force reduction has been achieved in soil materials by imparting vibration to tooling interfaces such as a vibratory farming cultivator, a percussive scoop, and ultrasonically resonant penetrators. Vibration-assisted tools in granular media reduce interaction forces by fluidizing a volume around the tool, allowing the tool to progress through a dynamic (fluid) medium instead of a static (solid) medium. This work seeks to quantify ultrasonic vibration’s effect on the force response of a penetrator in lunar soil simulant in vacuum sufficient to be within the molecular flow regime of any disturbed gases. Methods: A custom vacuum chamber setup, CUBEvac, was designed and built to facilitate penetration testing in a high vacuum environment, for comparison to penetration behavior in ambient terrestrial environment. A two-stage pumping system (Agilent Triscroll 600 roughing pump, Agilent VHS-6 oil diffusion pump) reached chamber pressures of about 5x10-6 Torr with regolith simulant in place. Figure 1 is a schematic of the heart of the assembly (note the penetration drive mechanisms above the chamber feedthrough and the regolith simulant sample in the bottom are not shown). The penetration actuation stack was comprised of a stepper motor driving a lead screw to move the ultra-sonic probe vertically inside the chamber. Motion was coordinated with an Arduino Uno. GRC-3 lunar simulant was used for this set of experiments. Samples were prepared in a four-liter stain-less steel, cylindrical pot with an internal diameter of approximately 15.56 cm (6.125 in) and a depth of 19.37 cm (7 5/8 in) for testing. The soil was baked out prior to compaction preparation as a measure to reduce soil moisture which interfered with pump down capacity. The soil was not baked again if it was removed from the vacuum chamber, prepped, and immediately returned to the vacuum chamber for pump down. The soil was compacted using a 60 Hz vibration table with a surcharge of 34 kg place on top of the soil in the container. Prepared soil samples weighed approximately 6.5 kg (bulk density 1.895-1.934 g/cm3). Two probe end effectors were tested: A cone penetrometer (static only) with a nominal diameter of 12.7 mm (0.5 in) and a nominal height of 28.6 mm (1.125 in); and a vibrating cylindrical probe measuring 12.7 mm in diameter and 50.8 mm in effective length from the tip (Figure 2). The cylindrical probe vibrated resonantly at 20 kHz with an amplitude 23 μm. The cone penetration tests were conducted to assess potential soil behavior differences in vacuum. The cylinder probe tests were conducted as the primary subject of this investigation to assess force response in vacuum. For each test, a regolith simulant sample was load-ed and compacted in the chamber, which was then evacuated for roughly 18 hours to reach the lowest possible pressure (approximately 5x10-6 Torr for most tests). The probe was then moved to about 10 mm above the soil surface before being pushed to a depth of 50 mm for the cylinder probe tests and to a depth of 100 mm for the cone penetrometer tests, both at a speed of 2 mm/s. The simulant samples were prepared the same for all tests. Ideally, they would respond consistently to probe penetration under ambient and vacuum conditions. This was evaluated by measuring the resistance of representative prepared simulant beds with a standard cone penetrometer in both environments. Results and Discussion: The resistance of the simulant samples in the vacuum tests was consistently lower than in the ambient tests as determined by the cone penetration tests. Thus, the ambient and vacuum results cannot be compared directly; work is underway to de-confound and better correlate the data. Still, figures 3-6 show that probe penetration forces are lower overall in the vacuum environment. In both environments, resonant vibration of the probe provides two useful effects: It reduces the probe penetration force and smooths the force-depth curve, significantly reducing local maxima. These effects have implications for various potential applications, such as astronaut hand-tools, where benefits (reducing astronaut effort) outweigh the cost of the additional energy re-quired to generate vibration. These results demonstrate that resonantly vibrating tools can meaningfully reduce the penetration force required for excavation, probing, and drilling tools in simulated lunar regolith deposits under vacuum levels approaching those that will be experience on the Moon’s surface. Lunar-gravity, ambient environment tests are scheduled soon. The effects of realistic temperatures and temperature gradients and deeper vacuum remain to be tested.

E Rezich↗

Automated Desalting Apparatus

Because salt and metals can mask the signature of a variety of organic molecules (like amino acids) in any given sample, an automated system to purify complex field samples has been created for the analytical techniques of electrospray ionization/ mass spectroscopy (ESI/MS), capillary electrophoresis (CE), and biological assays where unique identification requires at least some processing of complex samples. This development allows for automated sample preparation in the laboratory and analysis of complex samples in the field with multiple types of analytical instruments. Rather than using tedious, exacting protocols for desalting samples by hand, this innovation, called the Automated Sample Processing System (ASPS), takes analytes that have been extracted through high-temperature solvent extraction and introduces them into the desalting column. After 20 minutes, the eluent is produced. This clear liquid can then be directly analyzed by the techniques listed above. The current apparatus including the computer and power supplies is sturdy, has an approximate mass of 10 kg, and a volume of about 20 20 20 cm, and is undergoing further miniaturization. This system currently targets amino acids. For these molecules, a slurry of 1 g cation exchange resin in deionized water is packed into a column of the apparatus. Initial generation of the resin is done by flowing sequentially 2.3 bed volumes of 2N NaOH and 2N HCl (1 mL each) to rinse the resin, followed by .5 mL of deionized water. This makes the pH of the resin near neutral, and eliminates cross sample contamination. Afterward, 2.3 mL of extracted sample is then loaded into the column onto the top of the resin bed. Because the column is packed tightly, the sample can be applied without disturbing the resin bed. This is a vital step needed to ensure that the analytes adhere to the resin. After the sample is drained, oxalic acid (1 mL, pH 1.6-1.8, adjusted with NH4OH) is pumped into the column. Oxalic acid works as a chelating reagent to bring out metal ions, such as calcium and iron, which would otherwise interfere with amino acid analysis. After oxalic acid, 1 mL 0.01 N HCl and 1 mL deionized water is used to sequentially rinse the resin. Finally, the amino acids attached to the resin, and the analytes are eluted using 2.5 M NH4OH (1 mL), and the NH4OH eluent is collected in a vial for analysis.

Spencer, Maegan K.↗