Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SURFACE CONTAMINATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Flight evidence of spacecraft surface contamination rate enhancement by spacecraft charging obtained with a quartz crystal microbalance

The significance of the fraction of the mass outgassed by a negatively charged space vehicle which is ionized within the vehicle plasma sheath and electrostatically reattracted to the space vehicle was determined. The ML-12 retarding potential analyzer/temperature controlled quartz crystal microbalances (RPA/TQCMs) distinguishes between charged and neutral molecules and investigates contamination mass transport mechanism. Two long term, quick look flight data sets indicate that on the average a significant fraction of mass arriving at one RPA/TQCM is ionized. It is assumed that vehicle frame charging during these periods was approximately uniformly distributed in degree and frequency. It is shown that electrostatic reattraction of ionized molecules is an important contamination mechanism at and near geosynchronous altitudes.

Clark, D. M.↗

Materials SIG quantification and characterization of surface contaminants

When LDEF entered orbit its cleanliness was approximately a MIL-STD-1246B Level 2000C. Its burden of contaminants included particles from every part of its history including a relatively small contribution from the shuttle bay itself. Although this satellite was far from what is normally considered clean in the aerospace industry, contaminating events in orbit and from processing after recovery were easily detected. The molecular contaminants carried into orbit were dwarfed by the heavy deposition of UV polymerized films from outgassing urethane paints and silicone based materials. Impacts by relatively small objects in orbit could create particulate contaminants that easily dominated the particle counts within a centimeter of the impact site. During the recovery activities LDEF was 'sprayed' with a liquid high in organics and water soluble salts. With reentry turbulence, vibration, and gravitational loading particulate contaminants were redistributed about LDEF and the shuttle bay.

Crutcher, E. Russ↗

Device For Sampling Surface Contamination

Specially designed cotton swab suitable for use in clean room. Contamination-sampling device improved version of basic cotton-tipped wooden applicator, designed for extreme cleanliness and to enhance utility for sampling according to exacting specifications. Device does not shed cotton and wood fibers.

Delgado, Felix A.↗

Using Optically Stimulated Electron Emission as an Inspection Method to Monitor Surface Contamination

During redesign of the Space Shuttle reusable solid rocket motor (RSRM), NASA amended the contract with ATK Launch Systems (then Morton Thiokol Inc.) with Change Order 966 to implement a contamination control and cleanliness verification method. The change order required: (1) A quantitative inspection method (2) A written record of actual contamination levels versus a known reject level (3) A method that is more sensitive than existing methods of visual and black light inspection. Black light inspection is only useful for inspection of contaminants that fluoresce near the 365 nm spectral line and is not useful for inspection of most silicones that will not produce strong fluorescence. Black light inspection conducted by a qualified inspector under controlled light is capable of detecting Conoco HD-2 grease in gross amounts and is very subjective due to operator sensitivity. Optically stimulated electron emission (OSEE), developed at the Materials and Process Laboratory at Marshall Space Flight Center (MSFC), was selected to satisfy Change Order 966. OSEE offers several important advantages over existing laboratory methods with similar sensitivity, e.g., spectroscopy and nonvolatile residue sampling, which provide turn around time, real time capability, and full coverage inspection capability. Laboratory methods require sample gathering and in-lab analysis, which sometimes takes several days to get results. This is not practical in a production environment. In addition, these methods do not offer full coverage inspection of the large components

Lingbloom, Mike S.↗

Portable Fourier Transform Spectroscopy for Analysis of Surface Contamination and Quality Control

Progress has been made into adapting and enhancing a commercially available infrared spectrometer for the development of a handheld device for in-field measurements of the chemical composition of various samples of materials. The intent is to duplicate the functionality of a benchtop Fourier transform infrared spectrometer (FTIR) within the compactness of a handheld instrument with significantly improved spectral responsivity. Existing commercial technology, like the deuterated L-alanine triglycine sulfide detectors (DLATGS), is capable of sensitive in-field chemical analysis. This proposed approach compares several subsystem elements of the FTIR inside of the commercial, non-benchtop system to the commercial benchtop systems. These subsystem elements are the detector, the preamplifier and associated electronics of the detector, the interferometer, associated readout parameters, and cooling. This effort will examine these different detector subsystem elements to look for limitations in each. These limitations will be explored collaboratively with the commercial provider, and will be prioritized to meet the deliverable objectives. The tool design will be that of a handheld gun containing the IR filament source and associated optics. It will operate in a point-and-shoot manner, pointing the source and optics at the sample under test and capturing the reflected response of the material in the same handheld gun. Data will be captured via the gun and ported to a laptop.

Pugel, Diane↗

The Ability of AMSTAR Dechlorination Solution to Remove and Degrade PCBs from Contaminated Surfaces

Polychlorinated biphenyls (PCBs) are a group of synthetic aromatic compounds with the general formula C12H(10-x)Cl(-x) that were historically used in industrial paints, caulking material and adhesives, as their properties enhanced structural integrity, reduced flammability and boosted antifungal properties. Although the United States Environmental Protection Agency (USEPA) has banned the manufacture of PCBs since 1979, they have been found in at least 500 of the 1,598 National Priorities List (Superfund) sites identified by the USEPA. Prior to the US EPA's ban on PCB production, PCBs were commonly used as additives in paints and asphalt-based adhesives that were subsequently applied to a variety of structures. Government facilities constructed as early as 1930 utilized PCB-containing binders or PCB-containing paints, which are now leaching into the environment and posing ecological and worker health concerns. In 2006, a commercially available product known as AMSTAR Dechlorination Solution was tested at NASA's Kennedy Space Center for its ability to remove and degrade PCBs from structural materials. This evaluation was requested by the Environmental Security Technology Certification Program (ESTCP) evaluating the ability of NASA's Bimetallic Treatment System (BTS) to remove and degrade PCBs from structural materials. The results of the laboratory testing are to be used to determine if a side-by-side field-scale test comparing BTS to AMSTAR was warranted. A recommended sampling and analysis testing program was submitted to ESTCP that included triplicate screening of AMSTAR's PCB dechlorination capabilities on a variety of surfaces including glass, bare metal, and painted metal coupons. The test procedures, analytical techniques and results obtained are presented in this interim report to ESTCP.

Quinn, Jacqueline E.↗

Characterization of Low Pressure Cold Plasma in the Cleaning of Contaminated Surfaces

The characterization of low pressure cold plasma is a broad topic which would benefit many different applications involving such plasma. The characterization described in this paper focuses on cold plasma used as a medium in cleaning and disinfection applications. Optical Emission Spectroscopy (OES) and Mass Spectrometry (MS) are the two analytical methods used in this paper to characterize the plasma. OES analyzes molecules in the plasma phase by displaying the light emitted by the plasma molecules on a graph of wavelength vs. intensity. OES was most useful in identifying species which may interact with other molecules in the plasma, such as atomic oxygen or hydroxide radicals. Extracting useful data from the MS is done by filtering out the peaks generated by expected molecules and looking for peaks caused by foreign ones leaving the plasma chamber. This paper describes the efforts at setting up and testing these methods in order to accurately and effectively characterize the plasma.

cold plasma characterization↗