Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SUBSTATIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

E1 Illumination of a Substation Protection System

Sandia’s CRADA partnership with EPRI for calendar year 2017 helped further the technical basis of understanding on the effects to the electric power distribution system infrastructure (i.e., the grid), from a high altitude electromagnetic pulse (HEMP) event. This joint effort yielded evaluation of multiple SCADA relays to very high transient electric fields that were comparable in frequency content to a HEMP event, in multiple equipment configurations that are representative to how the units are fielded and utilized. Both Sandia and EPRI benefit from the data collected. Sandia directly benefits the LDRD effort to address EMP on electrical system infrastructures. EPRI direct benefits the stakeholders they are representing in the power industry. Stakeholders are power generation and distribution companies and equipment manufactures. The results would be used for product improvement and EMP hardening as well as informing the customer base of potential shortfalls of the product to a HEMP event.To better understand the impacts of HEMP on supervisory control and data acquisition (SCADA) systems in typical use at bulk power facilities, Sandia and EPRI has brought together their unique skills and equipment/facilities. EPRI, representing the stakeholders of the power industry, brings technical experience of how supervisory control and data acquisition (SCADA) systems are typically fielded and utilized in real-world applications. With this, EPRI will provides field hardware relating to the SCADA systems. Sandia National Laboratories (Sandia) provides unique test facilities (Sandia’s Electromagnetic Environment Simulator (EMES) and Large Gigahertz Transverse Electromagnetic (GTEM)) and test equipment capabilities to evaluate the SCADA systems to a simulated HEMP event. Sandia brings hands on experience of conducting susceptibility and vulnerability assessments for critical components and systems to high power incident HEMP illumination.

Molina, Luis↗

Fifth-Generation District Heating and Cooling Substations: Demand Response with Artificial Neural Network-Based Model Predictive Control

District heating and cooling (DHC) is considered one of the most sustainable technologies to meet the heating and cooling demands of buildings in urban areas. The fifth-generation district heating and cooling (5GDHC) concept, often referred to as ambient loops, is a novel solution emerging in Europe and has become a widely discussed topic in current energy system research. 5GDHC systems operate at a temperature close to the ground and include electrically driven heat pumps and associated thermal energy storage in a building-sited energy transfer station (ETS) to satisfy user comfort. This work presents new strategies for improving the operation of these energy transfer stations by means of a model predictive control (MPC) method based on recurrent artificial neural networks. The results show that, under simple time-of-use utility rates, the advanced controller outperforms a rule-based controller for smart charging of the domestic hot water (DHW) thermal energy storage under specific boundary conditions. By exploiting the available thermal energy storage capacity, the MPC controller is capable of shifting up to 14% of the electricity consumption of the ETS from on-peak to off-peak hours. Therefore, the advanced control implemented in 5GDHC networks promotes coupling between the thermal and the electric sector, producing flexibility on the electric grid.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Minimax control of a system with process uncertainty in substate space

The control of a single input-single output plant with parameter uncertainty was approached using a minimax technique. A linear time invariant controller results which requires only partial state feedback and is optimal in the sense that it minimizes a quadratic criterion involving tracking error, control, and parameter uncertainty. Bounded input-bounded output stability is guaranteed provided the transfer function has only left half plane zeros. If uncertainties are bounded, it is always possible to stabilize the system when sufficient control amplitude is available. The number of states required to generate the control is equal to the system order less the number of zeros.

Basuthakur, S.↗

The two consecutive M substates in the photocycle of bacteriorhodopsin are affected specifically by the D85N and D96N residue replacements

The photocycle of the proton pump bacteriorhodopsin contains two consecutive intermediates in which the retinal Schiff base is unprotonated; the reaction between these states, termed M1 and M2, was suggested to be the switch in the proton transport which reorients the Schiff base from D85 on the extracellular side to D96 on the cytoplasmic side (Varo and Lanyi, Biochemistry 30, 5016-5022, 1991). At pH 10 the absorption maxima of both M1 and M2 could be determined in the recombinant D96N protein. We find that M1 absorbs at 411 nm as do M1 and M2 in wild-type bacteriorhodopsin, but M2 absorbs at 404 nm. Thus, in M2 but not M1 the unprotonated Schiff base is affected by the D96N residue replacement. The connectivity of the Schiff base to D96 in the detected M2 state, but not in M1, is thereby established. On the other hand, the photostationary state which develops during illumination of D85N bacteriorhodopsin contains an M state corresponding to M1 with an absorption maximum shifted to 400 nm, suggesting that this species in turn is affected by D85. These results are consistent with the suggestion that M1 and M2 are pre-switch and post-switch states, respectively.

NASA Discipline Exobiology↗

Secured fault detection in a power substation

Systems and methods for fault detection and protection in electric power systems that evaluates electromagnetic transients caused by faults. A fault can be detected using sampled data from a first monitored point in the power system. Detection of fault transients and associated characteristics, including transient direction, can also be extracted through evaluation of sample data from other monitored points in the power system. A monitoring device can evaluate whether to trip a switching device in response to the detection of the fault and based on confirmation of an indication of detection of fault transients at the other monitored points of the power system. The determination of whether to trip or activate the switching device can also be based on other factors, including the timing of receipt of an indication of the detection of the fault transients and/or an evaluation of the characteristics of the detected transients.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Secured fault detection in a power substation

Systems and methods for fault detection and protection in electric power systems that evaluates electromagnetic transients caused by faults. A fault can be detected using sampled data from a first monitored point in the power system. Detection of fault transients and associated characteristics, including transient direction, can also be extracted through evaluation of sample data from other monitored points in the power system. A monitoring device can evaluate whether to trip a switching device in response to the detection of the fault and based on confirmation of an indication of detection of fault transients at the other monitored points of the power system. The determination of whether to trip or activate the switching device can also be based on other factors, including the timing of receipt of an indication of the detection of the fault transients and/or an evaluation of the characteristics of the detected transients.

Cui, Tao↗

Methods and systems for detection of man-in-the-middle attacks for SCADA communication networks and applications of same

A system for detecting MITM for SCADA communication networks includes secure substation-substation communication links for providing secure and reliable paths to exchange OT data between substations for OT data consistency check; a SIB in each substation for sampling CT and PT measurements to calculate voltage magnitude and phase angle thereof; a S&C server in each substation coupled to the SIB for receiving the voltage magnitude and phase angle from the SIB and obtaining a packet carrying active power flow in transmission lines between two substations and a time stamp; an IDS server placed in a SCADA center for collecting the packet of each substation sent by the S&C server; analyzing the received packet from every adjacent substation; inspecting the payload of the received packet; and triggering an intrusion alarm to a SCADA operator when the power flow is not the same as the payload of the packets.

McCann, Roy A.↗

Resilient Core Networks for Energy Distribution

Abstract—Substations and their control are crucial for the availability of electricity in today’s energy distribution. Ad- vanced energy grids with Distributed Energy Resources require higher complexity in substations, distributed functionality and communication between devices inside substations and between substations. Also, substations include more and more intelligent devices and ICT based systems. All these devices are connected to other systems by different types of communication links or are situated in uncontrolled environments. Therefore, the risk of ICT based attacks on energy grids is growing. Consequently, security measures to counter these risks need to be an intrinsic part of energy grids. This paper introduces the concept of a Resilient Core Network to interconnected substations. This core network provides essen- tial security features, enables fast detection of attacks and allows for a distributed and autonomous mitigation of ICT based risks.

Kuntze, Nicolai↗