Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STORAGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Southeast Regional CO 2 Utilization and Storage Acceleration Partnership (SECARB-USA): Preliminary Regional Assessment of Potential Storage Complexes, Including Capacities and Costs, Based on Application of NRAP and SCO2T (Deliverable 3.3) Storage Complexes

The Recipient will assist with the field validation of one or more risk assessment toolsets through: 1) collaborative research; 2) sharing of relevant datasets, information, and technical insights from field efforts; and 3) other modeling and simulation toolsets as they are developed. Collaborative research could include, but is not limited to: 1) demonstrating use of field data for improved leakage pathway characterization, uncertainty reduction, and risk management and uncertainty workflows; 2) testing and validation of a specific National Risk Assessment Partnership (NRAP) tool using site specific data; and 3) improved modeling or reduced-order modeling of geophysical monitoring.

42 ENGINEERING↗

From core-scale experiment to reservoir-scale modeling: A scale-up approach to investigate reaction-induced permeability evolution of CO2 storage reservoir and caprock at a U.S. CO2 storage site

Mineral dissolution and secondary mineral precipitation can cause porosity and permeability changes of CO 2 storage reservoirs and caprocks after injection of CO 2 . In this paper, a 3-step approach (core-scale experiment →core-scale modeling →reservoir-scale modeling) is developed to simulate reservoir-scale porosity and permeability evolution of CO 2 storage formation and caprock at a model CO 2 storage site. The model site is based on characteristics of a real site in Mississippi, USA. Important chemical and permeability modeling parameters in the reservoir-scale model are validated by core-scale experimental and reactive transport modeling results. The reservoir-scale model predicts a maximum 3.2% permeability increase of the CO 2 storage formation and a maximum 1.1% permeability increase of the caprock after 1000 years of exposure to CO 2 -rich brine, while the core-scale model predicts 7% permeability decrease for a small CO 2 storage formation core and 296% permeability increase for a small caprock core after 180-day exposure to CO 2 -rich brine. The discrepancy between permeability results of reservoir-scale model and core-scale model is attributed to strong pH buffering effect of CO 2 storage formation with large mass of H+-consuming minerals. Therefore, using core-scale experiments/models only is not sufficient to elucidate reservoir-scale permeability evolution. Variations of key model parameters have a small effect on permeability evolution of both CO 2 storage formation and caprock, except for variations of K eq (SiO 2 (am)) and the exponent n in permeability-porosity correlation. SiO 2 (am) is a key mineral that governs permeability evolution of CO 2 storage formation and caprock, given the characteristics of the model CO 2 storage site.

58 GEOSCIENCES↗

Underground Natural Gas Storage - Analog Studies to Geologic Storage of CO 2

The purpose of this report is to compile a stand-alone body of knowledge regarding historical and current underground natural gas storage operations that may be directly or indirectly relevant to carbon dioxide (CO 2 ) geologic storage in saline-bearing formations. This is the first of three planned documents that evaluate analog industries of CO 2 storage (the second focuses on wastewater disposal using United States [U.S.] Environmental Protection Agency [EPA] Underground Injection Control [UIC] Class I disposal wells, and the third on CO 2 enhanced oil recovery). Natural gas has been stored underground for over 100 years. This type of storage is necessary for meeting seasonal demand requirements as well as insuring against unforeseen supply disruptions. There are significant similarities that exist between natural gas storage and CO 2 geologic storage (and full-scale carbon capture and storage [CCS]) in terms of site selection and characterization, as well as operational procedures, and the equipment used. Therefore, the extensive operational history of underground natural gas storage operations provides a wealth of knowledge and lessons learned from which CO 2 storage stakeholders in industry, academia, and policy can benefit.

03 NATURAL GAS↗

Underground Natural Gas Storage – Analog Studies to Geologic Storage of CO 2

This study focuses on underground natural gas storage operations and CO 2 geologic storage in saline-bearing formations; both individually and in relation to each other. This study is the first of three that evaluate analog industries of CO 2 storage (second focuses on deep well waste disposal using U.S. EPA UIC Class I wells and third on CO 2 EOR). Several pieces of information can be found throughout the study including overview of underground natural gas storage history and side-by-side comparisons of major synergistic features between underground natural gas storage and CO 2 storage in saline-bearing formations. Best practices and lessons learned from underground natural gas storage operations can provide perspective from which future CO 2 storage R&D pursuits and field projects can benefit. A summary document providing a high-level overview and key takeaways of this study is available on NETL’s website under the Collection Name: NETL’s Analog Studies to Geologic Storage of CO 2 .

03 NATURAL GAS↗

Dynamic Earth Energy Storage: Terawatt-Year, Grid-Scale Energy Storage using Planet Earth as a Thermal Battery (GeoTES): Seedling Project Final Report

Grid-scale energy storage has been identified as a needed technology to support the continued build-out of intermittent renewable energy resources. As of April 2017, the U.S. had approximately 24.2 GW of energy storage on line, compared to 1,081 GW of installed generation capacity (Litynski et al. 2006, Hellstrom 2003). This represents a large shortfall of the storage needed to stabilize the U.S. grids with the rising penetration of renewable energy. Our team proposed to address this shortfall through the storage of excess energy as geothermal brine in deep geologic formations. This concept, known as geologic thermal energy storage (GeoTES), relies on the storage of thermal energy in geologic formations for recovery and use in large-scale direct use geothermal applications. As such, GeoTES has the potential to play a significant role in meeting the energy storage shortfall in the coming decades by assisting with peak demand ramping, easing stress on transmission, providing regional storage to support sustainable direct use geothermal applications, and providing a variety of grid stabilization benefits due to renewable outages or inaccurate forecasting and rotor stability.

15 GEOTHERMAL ENERGY↗

Hydrogen underground storage for grid electricity storage: An optimization study on techno-economic analysis

Here, this study performs a techno-economic analysis of hydrogen underground storage systems for grid electricity storage, evaluating their economic viability at the plant scale using dynamic optimization. It explores the feasibility of various system configurations and revenue models in the context of volatile electricity prices and the necessity for multiple revenue streams. The hypothesis tested is that large-scale hydrogen storage, despite its low round-trip efficiency, can be economically viable with the right mix of revenue streams. This study uses scenario-based analysis to assess the impacts of different system configurations, including engaging in time-shifting arbitrage, ancillary service markets and blending hydrogen with natural gas. Results indicate potential annual net cash flows of up to $\$$1.5 million from ancillary services integration and $\$$5.2 million from natural gas blending, contingent on specific system sizes. The study concludes that hydrogen underground storage for grid electricity storage can be profitable, and emphasizes that proper system design and precise electricity price forecasting are crucial for optimizing system performance and economic returns. This research sets the stage for further investigations into the scalability of hydrogen storage systems and their broader implications for grid electricity storage and energy market dynamics.

25 ENERGY STORAGE↗

Risk-based area of review estimation in overpressured reservoirs to support injection well storage facility permit requirements for CO 2 storage projects

This paper by the Energy & Environmental Research Center presents a workflow and modeling approach for delineating a risk-based area of review (AOR) to support a U.S. Environmental Protection Agency (EPA) Class VI permit for a carbon dioxide (CO 2 ) storage project. The approach combines semianalytical solutions for estimating formation fluid leakage through a hypothetical leaky wellbore with the results of numerical reservoir simulations to define the AOR. The modeling utilizes 1) semianalytical solutions from the peer-reviewed literature for formation fluid leakage through abandoned wellbores by Raven (1990) and Avci (1994), 2) a FORTRAN model compiled and described in Cihan et al. (2011, 2012) called ASLMA (Analytical Solution for Leakage in Multilayered Aquifers), and 3) a computational framework for estimating a risk-based AOR first proposed by Oldenburg et al. (2014, 2016). Therefore, the approach builds upon well-established research and underlying hydrogeological principles that have been upheld for nearly three decades. Moreover, the ASLMA model has been broadly applied to an array of storage projects. The work presented herein extends these earlier works using a custom wrapper written in the software environment, R (R Core Team, 2020), which was developed to perform multiple runs of the ASLMA model using given ranges for one or more input parameters. In addition, the current work simulates the pressure buildup within the storage reservoir in response to CO 2 injection using a compositional simulator to better accommodate the temporospatial evolution of pressure buildup within the storage reservoir that is more accurately modeled using a heterogeneous geologic model and a compositional simulator that accounts for the multiphase interactions. The workflow is demonstrated using a case study for a 180,000-metric-ton-per-year storage project located in the PCOR (Plains CO 2 Reduction) Partnership region. For the storage project evaluated here, under the scenario where the leaky wellbore is open to a saline aquifer (thief zone) between the overlying seal (cap rock) and the underground sources of drinking water (USDW), the risk-based AOR essentially collapses to the areal extent of the CO 2 plume in the storage reservoir because the pressure buildup in the storage reservoir beyond the CO 2 plume is insufficient to drive formation fluids up a hypothetical leaky wellbore into the USDW. However, even under the conservative assumption that the leaky wellbore is not open to a thief zone, beyond the areal extent of the CO 2 plume, the incremental leakage is less than 400 m 3 over 20 years, which represents ~0.0001% or less of the total volume of water contained within the USDW rock volume. As discussed in the text, the threshold criterion for defining the risk-based AOR is site-specific and should be informed by the results of the sensitivity analysis and available site characterization data. The approach outlined in this paper is designed to be protective of USDWs and, therefore, comply with the Safe Drinking Water Act requirements and provisions for the U.S. EPA Class VI Underground Injection Control (UIC) Program (Class VI Rule) and North Dakota Administrative Code Chapter 43-05-01.

54 ENVIRONMENTAL SCIENCES↗

Developing a roadmap for carbon capture, and storage in Oklahoma by assessing the viability of stacked storage

Abstract The Intergovernmental Panel on Climate Change concludes that CO 2 capture and storage (CCS) is critical for climate‐stabilizing energy transitions. In CCS, captured CO 2 is sequestered in saline aquifers within sedimentary basins. The CO 2 storage capacity and the rate of injection are functions of the geology of the saline aquifer, which is uncertain. To minimize impacts of this uncertainty, CCS projects could include backup plans, such as co‐locating geologic CO 2 storage (GCS) sites with or near existing CO 2 ‐enhanced oil recovery (CO 2 ‐EOR) operations. These “stacked storage” projects could hedge against uncertainty in the saline formation performance because captured CO 2 could be injected into either location in the event of unexpected events (e.g., the injectivity decreases). Here, we investigate the possibility and ramifications of developing CCS networks in Oklahoma that are amendable to stacked storage. We find that stacked storage is possible in Oklahoma but the counties with the lowest‐cost saline storage resources do not have existing CO 2 ‐EOR operations. At the systems level, we find it is slightly more expensive (e.g., $1/tCO 2 to $5/tCO 2 ) to site GCS in counties with CO 2 ‐EOR projects. This increased expense is largely due to increased CO 2 transportation costs because hundreds of km of additional pipeline is required to capture CO 2 from the lowest‐cost sources. Overall, our results suggest that it is optimal to build more pipelines and avoid injecting CO 2 in some of the lowest‐cost saline storage resources, to enable capturing CO 2 from the least‐cost sources. © 2023 Society of Chemical Industry and John Wiley & Sons, Ltd.

42 ENGINEERING↗

Element mobilization and immobilization from carbonate rocks between CO 2 storage reservoirs and the overlying aquifers during a potential CO 2 leakage

Despite the numerous studies on changes within the reservoir following CO2 injection and the effects of CO2 release into overlying aquifers, little or no literature is available on the effect of CO2 release on rock between the storage reservoirs and subsurface. To address this knowledge gap, relevant rock materials, temperatures and pressures were used to study mineralogical and elemental changes in this intermediate zone. After rocks reacted with CO2, liquid analysis showed an increase of major elements (e.g., Ca, and Mg) and variable concentrations of potential contaminants (e.g., Sr and Ba); lower concentrations were observed in N2 controls. In experiments with As/Cd and/or organic spikes, representing potential contaminants in the CO2 plume originating in the storage reservoir, most or all of these contaminants were removed from the aqueous phase. SEM and Mössbauer spectroscopy results showed the formation of new minerals and Fe oxides in some CO2-reacted samples, indicating potential for contaminant removal through mineral incorporation or adsorption onto Fe oxides. These experiments show the interactions between the CO2-laden plume and the rock between storage reservoirs and overlying aquifers have the potential to affect the level of risk to overlying groundwater, and should be considered during site selection and risk evaluation.

Environmental Molecular Sciences Laboratory↗

Nonenergy Biomass Carbon Removal and Storage (BiCRS): Assessing Durability of Nongaseous Carbon Products Across Terrestrial Storage Fates

Biomass Carbon Removal and Storage, or BiCRS, pathways use plants or algae that remove carbon dioxide from the atmosphere through photosynthesis and store it underground or in long-lived products. While some BiCRS approaches generate an energy product, all BiCRS approaches generate a carbon product. A new subset of BiCRS approaches focus on the storage of these raw or converted carbon products for generation of carbon credits. However, the durability of these approaches is highly variable as carbon products vary widely in their “form” and the conditions of their “fate.” We organize our thinking about carbon products and their durability around these two primary axes. The durability of carbon product “forms” is mediated by chemical recalcitrance and ranges substantially across agricultural residues, municipal solid waste, woody biomass, and nongaseous products of thermochemical conversion (e.g., biochars and bio-oils). Meanwhile, terrestrial storage “fates” vary in the mechanism employed to stall decay, including surface storage, dry storage, shallow anoxic storage, and deep or geologic anoxic storage (or injection). Each mechanism has different implications for suitability with different feedstock forms as well as long-term risks. We present a framework for assessing durability of solid or liquid raw and conversion carbon products under terrestrial storage fates, highlighting knowns, unknowns, and research priorities moving forward.

09 BIOMASS FUELS↗

Metal Organic Frameworks for Xenon Storage Applications

The demand for cheap and convenient xenon storage continues to rise due to its wide spectrum of applications. It is expected that solid-state adsorbents can provide significant advantages over the current isolated stainless-steel tank-based storage technologies. In this context, we investigated metal organic frameworks for use as adsorbents for xenon. Initially, three representative MOFs were synthesized and characterized in terms of Xe storage. The results were used to validate a computational modeling approach, which was later extended to a larger set of materials. The collected results allowed us to rationalize the key parameters (pore volume, surface area, void fraction etc.), which are important for good performance and selection of the best materials for xenon storage

Noble gas, Storage, MOFs↗

Joint charge storage for high-rate aqueous zinc-manganese dioxide batteries

Aqueous rechargeable zinc-manganese dioxide batteries have great promise for large-scale energy storage due to the use of environmental friendly, abundant, and rechargeable Zn metal anode and MnO2 cathode. In the literature various intercalation and conversion reaction mechanisms have been reported depending on the origin of the starting materials, but it is not clear how these mechanisms can be simultaneously manipulated to improve the charge storage and transport properties. Here, we report a systematical study to understand the electrolyte controlled charge-storage mechanisms in layered d-MnO2. A joint Zn2+ intercalation pseudocapacitance in bulky d-MnO2 and H+ conversion reaction pathway in a wide C-rate charge-discharge range facilitates the high rate performance of high capacity d-MnO2 cathodes. The Zn-d-MnO2 system delivers discharge capacity of 136.9 mAh g-1 at 20 C and capacity retention of 92% over 4,000 cycles with joint charge storage mechanisms.

Jin, Yan↗

Improving Frequency Stability and Minimizing Load Shedding Events by Adopting Grid-Scale Energy Storage with Grid Forming Inverters

The upward adoption trend of renewable generation not only means cleaner energy integrated into modern power grids, but also that most new generation sources are based on front-end inverter bridges, used as interfaces to most wind generation and all the solar PV. It is well known that due to their power electronics-based construction rather than rotational shafts, these sources do not provide inertia inherently, nor substantial amounts of short-circuit currents. However, stable energy such as what can be stored in energy storage systems, although interfaced via inverters, can be controlled to respond to system disturbances in a manner that emulates inertial behavior. This paper focuses on the application of such energy storage systems to augment inertia in the island of Puerto Rico. To do so, a user defined inverter model that contains grid forming capabilities and fast frequency response is modeled and integrated into the real transmission system in power flow and dynamics software. Energy storage is then connected to two selected areas so that it not only provides frequency regulation to avoid widespread load shedding events, but also other tangible benefits. The simulated cases suggest that even relatively small energy storage systems can avert load shedding events if adequately placed in the transmission network.

Grid-forming inverters, IBR, Inertia↗

Characterizing Hydrogen Storage Potential in U.S. Underground Gas Storage Facilities

Abstract Underground hydrogen storage is a long‐duration energy storage option for a low‐carbon economy. Although research into the technical feasibility of underground hydrogen storage is ongoing, existing underground gas storage (UGS) facilities are appealing candidates for the technology because of their ability to store and deliver natural gas. We estimate that UGS facilities in the United States (U.S.) can store 327 TWh (9.8 MMT) of pure hydrogen. A complete transition to hydrogen storage would reduce the collective working‐gas energy of UGS facilities by ∼75%; however, most (73.2%) UGS facilities could maintain current energy demand using a 20% hydrogen‐natural gas blend. U.S. UGS facilities can buffer 23.9%–44.6% of the high and low hydrogen demand projected for 2050, respectively, which exceeds the current percentage of natural gas demand buffered by storage. Thus, transitioning UGS infrastructure to hydrogen could substantially reduce the number of new hydrogen storage facilities needed to support a hydrogen economy.

08 HYDROGEN↗

2024 Stor4Build Annual Meeting: Exploring Challenges and Opportunities in Thermal Energy Storage for Buildings

In late August 2024, Stor4Build brought nearly 80 stakeholders from the thermal energy storage industry to Oak Ridge National Laboratory (ORNL), including researchers, startups, electric utilities, nonprofits, implementers, state energy efficiency offices, and original equipment manufacturers. During the two-day Stor4Build Annual Meeting, participants engaged in vital discussions about the current challenges and opportunities for scaling thermal energy storage solutions in buildings. The event featured panel discussions led by leading technology experts and industry practitioners, as well as updates on Stor4Build–funded projects from national laboratories, highlighting advancements in the thermal energy storage field crucial to achieving the consortium’s mission.

25 ENERGY STORAGE↗

Carbon Storage in Fold‐and‐Thrust Belts: An Overlooked Gigatonne Storage Opportunity

This study presents numerical investigations of the trapping characteristics of fold-and-thrust belt structures, defining three carbon capture and storage (CCS) play types that could be used to store commercial volumes (millions of tonnes) of CO 2 . Specifically, we present simulations of CO 2 storage in three fold-and-thrust belt models comprising a thrust-ramp, duplex, and thrust-fold geometry. To constrain these play types in realistic geology, each model is based on a study site, including a novel investigation of a greenfield saline reservoir in Virginia, USA, being considered for commercial carbon storage and two well-characterized petroleum fields: the Wilburton field in Oklahoma, USA, and the Incahuasi field in Bolivia. Our results provide insight into several key parameters, such as the long-term security of injected CO 2 in these geologies and injection strategies for maximizing storage efficiency while reducing pressure-related risk. These results improve the understanding of CCS in fold-and-thrust belt storage sites globally by describing general storage parameters that may be applied to site-specific projects. We find that thrust-ramp geometries may securely trap CO 2 through solubility and hydrodynamic trapping under suitable reservoir conditions, duplex structures may store some quantities of CO 2 but are pressure-constrained, and that thrust-ramp structures may store large quantities of CO 2 by maximizing fetch volume, which simultaneously lowers geomechanical risk by reducing pressure buildup along zones of weakness.

42 ENGINEERING↗

Getting brighter: Impacts of improved day-ahead solar forecasts in high-solar, high-storage electricity systems

This paper analyzes the impacts of improved day-ahead solar forecasts on costs and dispatch in the solar-rich Southeast U.S. It uses an optimized high-solar, high-storage resource portfolio in which solar generation capacity accounts for 45 % of total installed capacity (34 %–36 % of generation) and energy storage capacity (43 GW) is equivalent to 33 % of peak demand. In a base scenario, improved day-ahead solar forecasts reduce production costs by $\$87$ million per year ($\$0.13$ per MWh load, $2023$$). This level of savings is within the range or lower than earlier studies of solar forecast improvements at lower levels of solar generation (<25 % of total generation). In this study, solar expansion was accompanied by two important sources of flexibility for managing solar forecast error: energy storage and day-ahead solar curtailment. Furthermore, the analysis finds that regional coordination complements day-ahead solar forecast improvements while natural gas commitment flexibility is a substitute for forecast improvements, as the improved solar forecast leads to sub-optimal commitment of thermal units. Day-ahead solar forecast improvements reduce reserves required to manage forecast error by 30 %. Fewer reserves to manage large, infrequent solar forecast errors could be an important benefit of improved solar forecasts.

14 SOLAR ENERGY↗