Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STOMACH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Second cancer incidence risk estimates using BEIR VII models for standard and complex external beam radiotherapy for early breast cancer

Purpose: To compare organ specific cancer incidence risks for standard and complex external beam radiotherapy (including cone beam CT verification) following breast conservation surgery for early breast cancer.Method: Doses from breast radiotherapy and kilovoltage cone beam CT (CBCT) exposures were obtained from thermoluminescent dosimeter measurements in an anthropomorphic phantom in which the positions of radiosensitive organs were delineated. Five treatment deliveries were investigated: (i) conventional tangential field whole breast radiotherapy (WBRT), (ii) noncoplanar conformal delivery applicable to accelerated partial beast irradiation (APBI), (iii) two-volume simultaneous integrated boost (SIB) treatment, (iv) forward planned three-volume SIB, and (v) inverse-planned three volume SIB. Conformal and intensity modulated radiotherapy methods were used to plan the complex treatments. Techniques spanned the range from simple methods appropriate for patient cohorts with a low cancer recurrence risk to complex plans relevant to cohorts with high recurrence risk. Delineated organs at risk included brain, salivary glands, thyroid, contralateral breast, left and right lung, esophagus, stomach, liver, colon, and bladder. Biological Effects of Ionizing Radiation (BEIR) VII cancer incidence models were applied to the measured mean organ doses to determine lifetime attributable risk (LAR) for ages at exposure from 35 to 80 yr according to radiotherapy techniques, and included dose from the CBCT imaging. Results: All LAR decreased with age at exposure and were lowest for brain, thyroid, liver, and bladder (<0.1%). There was little dependence of LAR on radiotherapy technique for these organs and for colon and stomach. LAR values for the lungs for the three SIB techniques were two to three times those from WBRT and APBI. Uncertainties in the LAR models outweigh any differences in lung LAR between the SIB methods. Constraints in the planning of the SIB methods ensured that contralateral breast doses and LAR were comparable to WBRT, despite their added complexity. The smaller irradiated volume of the ABPI plan contributed to a halving of LAR for contralateral breast compared with the other plan types. Daily image guided radiotherapy (IGRT) for a left breast protocol using kilovoltage CBCT contributed <10% to LAR for the majority of organs, and did not exceed 22% of total organ dose. Conclusions: Phantom measurements and calculations of LAR from the BEIR VII models predict that complex breast radiotherapy techniques do not increase the theoretical risk of second cancer incidence for organs distant from the treated breast, or the contralateral breast where appropriate plan constraints are applied. Complex SIB treatments are predicted to increase the risk of second cancer incidence in the lungs compared to standard whole breast radiotherapy; this is outweighed by the threefold reduction in 5 yr local recurrence risk for patients of high risk of recurrence, and young age, from the use of radiotherapy. APBI may have a favorable impact on risk of second cancer in the contralateral breast and lung for older patients at low risk of recurrence. Intensive use of IGRTincreased the estimated values of LAR but these are dominated by the effect of the dose from the radiotherapy, and any increase in LAR from IGRT is much lower than the models' uncertainties.

60 APPLIED LIFE SCIENCES↗

Four-dimensional dose evaluation using deformable image registration in radiotherapy for liver cancer

Purpose: In order to evaluate the dosimetric impact of respiratory motion on the dose delivered to the target volume and critical organs during free-breathing radiotherapy, a four-dimensional dose was evaluated using deformable image registration (DIR). Methods: Four-dimensional computed tomography (4DCT) images were acquired for 11 patients who were treated for liver cancer. Internal target volume-based treatment planning and dose calculation (3D dose) were performed using the end-exhalation phase images. The four-dimensional dose (4D dose) was calculated based on DIR of all phase images from 4DCT to the planned image. Dosimetric parameters from the 4D dose, were calculated and compared with those from the 3D dose. Results: There was no significant change of the dosimetric parameters for gross tumor volume (p > 0.05). The increase D{sub mean} and generalized equivalent uniform dose (gEUD) for liver were by 3.1%{+-} 3.3% (p= 0.003) and 2.8%{+-} 3.3% (p= 0.008), respectively, and for duodenum, they were decreased by 15.7%{+-} 11.2% (p= 0.003) and 15.1%{+-} 11.0% (p= 0.003), respectively. The D{sub max} and gEUD for stomach was decreased by 5.3%{+-} 5.8% (p= 0.003) and 9.7%{+-} 8.7% (p= 0.003), respectively. The D{sub max} and gEUD for right kidney was decreased by 11.2%{+-} 16.2% (p= 0.003) and 14.9%{+-} 16.8% (p= 0.005), respectively. For left kidney, D{sub max} and gEUD were decreased by 11.4%{+-} 11.0% (p= 0.003) and 12.8%{+-} 12.1% (p= 0.005), respectively. The NTCP values for duodenum and stomach were decreased by 8.4%{+-} 5.8% (p= 0.003) and 17.2%{+-} 13.7% (p= 0.003), respectively. Conclusions: The four-dimensional dose with a more realistic dose calculation accounting for respiratory motion revealed no significant difference in target coverage and potentially significant change in the physical and biological dosimetric parameters in normal organs during free-breathing treatment.

60 APPLIED LIFE SCIENCES↗

SU-E-J-168: Automated Pancreas Segmentation Based On Dynamic MRI

Purpose: MRI guided radiotherapy is particularly attractive for abdominal targets with low CT contrast. To fully utilize this modality for pancreas tracking, automated segmentation tools are needed. A hybrid gradient, region growth and shape constraint (hGReS) method to segment 2D upper abdominal dynamic MRI is developed for this purpose. Methods: 2D coronal dynamic MR images of 2 healthy volunteers were acquired with a frame rate of 5 f/second. The regions of interest (ROIs) included the liver, pancreas and stomach. The first frame was used as the source where the centers of the ROIs were annotated. These center locations were propagated to the next dynamic MRI frame. 4-neighborhood region transfer growth was performed from these initial seeds for rough segmentation. To improve the results, gradient, edge and shape constraints were applied to the ROIs before final refinement using morphological operations. Results from hGReS and 3 other automated segmentation methods using edge detection, region growth and level set were compared to manual contouring. Results: For the first patient, hGReS resulted in the organ segmentation accuracy as measure by the Dices index (0.77) for the pancreas. The accuracy was slightly superior to the level set method (0.72), and both are significantly more accurate than the edge detection (0.53) and region growth methods (0.42). For the second healthy volunteer, hGReS reliably segmented the pancreatic region, achieving a Dices index of 0.82, 0.92 and 0.93 for the pancreas, stomach and liver, respectively, comparing to manual segmentation. Motion trajectories derived from the hGReS, level set and manual segmentation methods showed high correlation to respiratory motion calculated using a lung blood vessel as the reference while the other two methods showed substantial motion tracking errors. hGReS was 10 times faster than level set. Conclusion: We have shown the feasibility of automated segmentation of the pancreas anatomy based on dynamic MRI.

60 APPLIED LIFE SCIENCES↗

MO-E-17A-03: Monte Carlo CT Dose Calculation: A Comparison Between Experiment and Simulation Using ARCHER-CT

Purpose: To compare the CT doses derived from the experiments and GPU-based Monte Carlo (MC) simulations, using a human cadaver and ATOM phantom. Methods: The cadaver of an 88-year old male and the ATOM phantom were scanned by a GE LightSpeed Pro 16 MDCT. For the cadaver study, the Thimble chambers (Model 10×5−0.6CT and 10×6−0.6CT) were used to measure the absorbed dose in different deep and superficial organs. Whole-body scans were first performed to construct a complete image database for MC simulations. Abdomen/pelvis helical scans were then conducted using 120/100 kVps, 300 mAs and a pitch factor of 1.375:1. For the ATOM phantom study, the OSL dosimeters were used and helical scans were performed using 120 kVp and x, y, z tube current modulation (TCM). For the MC simulations, sufficient particles were run in both cases such that the statistical errors of the results by ARCHER-CT were limited to 1%. Results: For the human cadaver scan, the doses to the stomach, liver, colon, left kidney, pancreas and urinary bladder were compared. The difference between experiments and simulations was within 19% for the 120 kVp and 25% for the 100 kVp. For the ATOM phantom scan, the doses to the lung, thyroid, esophagus, heart, stomach, liver, spleen, kidneys and thymus were compared. The difference was 39.2% for the esophagus, and within 16% for all other organs. Conclusion: In this study the experimental and simulated CT doses were compared. Their difference is primarily attributed to the systematic errors of the MC simulations, including the accuracy of the bowtie filter modeling, and the algorithm to generate voxelized phantom from DICOM images. The experimental error is considered small and may arise from the dosimeters. R01 grant (R01EB015478) from National Institute of Biomedical Imaging and Bioengineering.

60 APPLIED LIFE SCIENCES↗

In vitro dose measurements in a human cadaver with abdomen/pelvis CT scans

Purpose: To present a study of radiation dose measurements with a human cadaver scanned on a clinical CT scanner. Methods: Multiple point dose measurements were obtained with high-accuracy Thimble ionization chambers placed inside the stomach, liver, paravertebral gutter, ascending colon, left kidney, and urinary bladder of a human cadaver (183 cm in height and 67.5 kg in weight) whose abdomen/pelvis region was scanned repeatedly with a multidetector row CT. The flat energy response and precision of the dosimeters were verified, and the slight differences in each dosimeter's response were evaluated and corrected to attain high accuracy. In addition, skin doses were measured for radiosensitive organs outside the scanned region with OSL dosimeters: the right eye, thyroid, both nipples, and the right testicle. Three scan protocols were used, which shared most scan parameters but had different kVp and mA settings: 120-kVp automA, 120-kVp 300 mA, and 100-kVp 300 mA. For each protocol three repeated scans were performed. Results: The tube starting angle (TSA) was found to randomly vary around two major conditions, which caused large fluctuations in the repeated point dose measurements: for the 120-kVp 300 mA protocol this angle changed from approximately 110° to 290°, and caused 8% − 25% difference in the point dose measured at the stomach, liver, colon, and urinary bladder. When the fluctuations of the TSA were small (within 5°), the maximum coefficient of variance was approximately 3.3%. The soft tissue absorbed doses averaged from four locations near the center of the scanned region were 27.2 ± 3.3 and 16.5 ± 2.7 mGy for the 120 and 100-kVp fixed-mA scans, respectively. These values were consistent with the corresponding size specific dose estimates within 4%. The comparison of the per-100-mAs tissue doses from the three protocols revealed that: (1) dose levels at nonsuperficial locations in the TCM scans could not be accurately deduced by simply scaling the fix-mA doses with local mA values; (2) the general power law relationship between dose and kVp varied from location to location, with the power index ranged between 2.7 and 3.5. The averaged dose measurements at both nipples, which were about 0.6 cm outside the prescribed scan region, ranged from 23 to 27 mGy at the left nipple, and varied from 3 to 20 mGy at the right nipple over the three scan protocols. Large fluctuations over repeated scans were also observed, as a combined result of helical scans of large pitch (1.375) and small active areas of the skin dosimeters. In addition, the averaged skin dose fell off drastically with the distance to the nearest boundary of the scanned region. Conclusions: This study revealed the complexity of CT dose fluctuation and variation with a human cadaver.

60 APPLIED LIFE SCIENCES↗

SU-C-210-05: Evaluation of Robustness: Dosimetric Effects of Anatomical Changes During Fractionated Radiation Treatment of Pancreatic Cancer Patients

Purpose: Pancreatic tumors show large interfractional position variations. In addition, changes in gastrointestinal air volume and body contour take place during treatment. We aim to investigate the robustness of the clinical treatment plans by quantifying the dosimetric effects of these anatomical changes. Methods: Calculations were performed for up to now 3 pancreatic cancer patients who had intratumoral fiducials for daily CBCT-based positioning during their 3-week treatment. For each patient, deformable image registration of the planning CT was used to assign Hounsfield Units to each of the 13—15 CBCTs; air volumes and body contour were copied from CBCT. The clinical treatment plan was used (CTV-PTV margin = 10 mm; 36Gy; 10MV; 1 arc VMAT). Fraction dose distributions were calculated and accumulated. The V95% of the clinical target volume (CTV) and planning target volume (PTV) were analyzed, as well as the dose to stomach, duodenum and liver. Dose accumulation was done for patient positioning based on the fiducials (as clinically used) as well as for positioning based on bony anatomy. Results: For all three patients, the V95% of the CTV remained 100%, for both fiducial- and bony anatomy-based positioning. For fiducial-based positioning, dose to duodenum en stomach showed no discernable differences with planned dose. For bony anatomy-based positioning, the PTV V95% of the patient with the largest systematic difference in tumor position (patient 1) decreased to 85%; the liver Dmax increased from 33.5Gy (planned) to 35.5Gy. Conclusion: When using intratumoral fiducials, CTV dose coverage was only mildly affected by the daily anatomical changes. When using bony anatomy for patient positioning, we found a decline in PTV dose coverage due to the interfractional tumor position variations. Photon irradiation treatment plans for pancreatic tumors are robust to variations in body contour and gastrointestinal gas, but the use of fiducial-based daily position verification is imperative. This work was supported by the foundation Bergh in het Zadel through the Dutch Cancer Society (KWF Kankerbestrijding) project No. UVA 2011-5271.

60 APPLIED LIFE SCIENCES↗

SU-E-T-242: Design of a Novel Afterloader Clearance QA Device for Biliary HDR Therapy

Purpose: Bile duct cancer affects 2–3 thousand people annually in the United States. Radiation therapy has been shown to double median survival, with combined external beam and intraluminal high dose-rate (HDR) brachytherapy being most effective. Endoscopic retrograde cholangiopancreatography (ERCP) biliary HDR, a less-invasive alternative to trans-hepatic brachytherapy, is delivered through a catheter that travels a tortuous path from nose to bile duct, requiring wire drive force and dexterity beyond typical afterloader performance specifications. Thus, specific afterloader quality assurance(QA) is recommended for this procedure. Our aim was to create a device and process for Varisource afterloader clearance QA with objectives that it be quantitative and can monitor afterloader performance over time, compare performance between two distinct afterloaders and potentially Result in a predictive nomogram for patient-specific clearance. Methods: Based on retrospective reconstruction of 20 ERCP patient anatomies, we designed a phantom to test afterloader ability to drive the source wire along an intended treatment path. The ability of the afterloader to fully extend the intended treatment path is a function of number and diameters of turns. We have determined experimentally that relative position of the turns does not impact performance. Results: Both patient and QA paths involve three common turns/loops: a large turn representing the stomach(10.8cm±2.0cm), an elliptical loop representing the duodenum(7.3cm±1.5cmx4.8cm±0.7cm), and a final turn at the end of the bile duct that may be tight for some patient-specific anatomies and absent in others(3.7cm±0.7cm, where present). Our phantom design uses anatomical average turn diameters for the stomach and duodenum then terminates in a turn of quantitatively selectable diameter. The smallest final turn diameter that an afterloader can pass is recorded as the QA parameter. Conclusion: With this device and QA process, we have the ability to quantitatively evaluate and track our afterloader performance for a technically challenging ERCP brachytherapy procedure.

60 APPLIED LIFE SCIENCES↗

SU-E-T-300: Dosimetric Comparision of 4D Radiation Therapy and 3D Radiation Therapy for the Liver Tumor Based On 4D Medical Image

Purpose: The purpose of this work was to determine the dosimetric benefit to normal tissues by tracking liver tumor dose in four dimensional radiation therapy (4DRT) on ten phases of four dimensional computer tomagraphy(4DCT) images. Methods: Target tracking each phase with the beam aperture for ten liver cancer patients were converted to cumulative plan and compared to the 3D plan with a merged target volume based on 4DCT image in radiation treatment planning system (TPS). The change in normal tissue dose was evaluated in the plan by using the parameters V5, V10, V15, V20,V25, V30, V35 and V40 (volumes receiving 5, 10, 15, 20, 25, 30, 35 and 40Gy, respectively) in the dose-volume histogram for the liver; mean dose for the following structures: liver, left kidney and right kidney; and maximum dose for the following structures: bowel, duodenum, esophagus, stomach and heart. Results: There was significant difference between 4D PTV(average 115.71cm3 )and ITV(169.86 cm3). When the planning objective is 95% volume of PTV covered by the prescription dose, the mean dose for the liver, left kidney and right kidney have an average decrease 23.13%, 49.51%, and 54.38%, respectively. The maximum dose for bowel, duodenum,esophagus, stomach and heart have an average decrease 16.77%, 28.07%, 24.28%, 4.89%, and 4.45%, respectively. Compared to 3D RT, radiation volume for the liver V5, V10, V15, V20, V25, V30, V35 and V40 by using the 4D plans have a significant decrease(P≤0.05). Conclusion: The 4D plan method creates plans that permit better sparing of the normal structures than the commonly used ITV method, which delivers the same dosimetric effects to the target.

60 APPLIED LIFE SCIENCES↗

SU-E-T-346: Effect of Jaw Position On Dose to Critical Structures in 3-D Conformal Radiotherapy Treatment of Pancreatic Cancer

Purpose: Three-dimensional conformal therapy remains a valid and widely used modality for pancreatic radiotherapy treatment. It usually meets dose constraints on critical structures. However, careful positioning of collimation jaws can reduce dose to the critical structures. Here we investigate the dosimetric effect of jaw position in MLC-based 3-D conformal treatment planning on critical structures. Methods: We retrospectively selected seven pancreatic cancer patients treated with 3-D conformal radiotherapy. We started with treatment plans (Varian Truebeam LINAC, Eclipse TPS, AAA, 18MV) having both x and y jaws aligned with the farthest extent of the block outline (8mm around PTV). Then we subsequently moved either both x-jaws or all x and y jaws outwards upto 3 cm in 1 cm increments and investigated their effect on average and maximum dose to neighboring critical structures keeping the same coverage to treatment volume. Results: Lateral displacement of both x-jaws by 1cm each increased kidney and spleen mean dose by as much as 1.7% and 1.3% respectively and superior inferior displacement increased liver, right kidney, stomach and spleen dose by as much as 2.1%, 2%, 5.2% and 1.6% respectively. Displacement of all x and y-jaws away by 1cm increased the mean dose to liver, right kidney, left kidney, bowels, cord, stomach and spleen by as much as 4.9%, 5.9%, 2.1%, 2.8%, 7.4%, 10.4% and 4.2% respectively. Percentage increase in mean dose due to 2 and 3cm jaw displacement increased almost linearly with the displaced distance. Changes in maximum dose were much smaller (mostly negligible) than the changes in mean dose. Conclusion: Collimation jaw position affects dose mostly to critical structures adjacent to it. Though treatment plans with MLCs conforming the block margin usually meet dose constraints to critical structures, keeping jaws all the way in, to the edge of the block reduces dose to the critical structures during radiation treatment.

60 APPLIED LIFE SCIENCES↗

SU-E-T-503: Intensity Modulated Proton Therapy (IMPT) Versus Intensity Modulated X-Ray Therapy (IMRT) for Patient with Hepatocellular Carcinoma: A Dosimetric Comparison

Purpose This study compares the dosimetric parameters in treatment of unresectable hepatocellular carcinoma between intensity modulated proton therapy (IMPT) and intensity modulated x-ray radiation therapy (IMRT). Methods and Materials: We studied four patients treated at our institution. All patients were simulated supine with 4D-CT using a GE light speed simulator with a maximum slice thickness of 3mm. The average CT and an internal target volume to account for respiration motion were used for planning. Both IMRT and IMPT plans were created using Elekta’s CMSXiO treatment planning system (TPS). The prescription dose was 58.05 CGE in 15 fractions. The IMRT plans had five beams with combination of co-planar and non-co-planar. The IMPT plans had 2 to 3 beams. Dose comparison was performed based on the averaged results of the four patients. Results The mean dose and V95% to PTV were 58.24CGE, 98.57% for IMPT, versus 57.34CGE and 96.68% for IMRT, respectively. The V10, V20, V30 and mean dose of the normal liver for IMPT were 23.10%, 18.61%, 13.75% and 9.78 CGE; and 47.19%, 37.55%, 22.73% and 17.12CGE for IMRT. The spinal cord didn’t receive any dose in IMPT technique, but received a maximum of 18.77CGE for IMRT. The IMPT gave lower maximum dose to the stomach as compared to IMRT (19.26 vs 26.35CGE). V14 for left and right kidney was 0% and 2.32% for IMPT and 3.89% and 29.54% for IMRT. The mean dose, V35, V40 and V45 for small bowl were similar in both techniques, 0.74CGE, 6.27cc, 4.85cc and 3.53 cc for IMPT, 3.47CGE, 9.73cc, 7.61cc 5.35cc for IMRT. Conclusion Based on this study, IMPT plans gave less dose to the critical structures such as normal liver, kidney, stomach and spinal cord as compared to IMRT plans, potentially leading to less toxicity and providing better quality of life for patients.

60 APPLIED LIFE SCIENCES↗

Radiotherapy for stage I seminoma of the testis: Organ equivalent dose to partially in-field structures and second cancer risk estimates on the basis of a mechanistic, bell-shaped, and plateau model

Purpose: The aim of the current study was to (a) calculate the organ equivalent dose (OED) and (b) estimate the associated second cancer risk to partially in-field critical structures from adjuvant radiotherapy for stage I seminoma of the testis on the basis of three different nonlinear risk models. Methods: Three-dimensional plans were created for twelve patients who underwent a treatment planning computed tomography of the abdomen. The plans for irradiation of seminoma consisted of para-aortic anteroposterior and posteroanterior fields giving 20 Gy to the target site with 6 MV photons. The OED of stomach, colon, liver, pancreas, and kidneys, that were partially included in the treatment volume, was calculated using differential dose–volume histograms. The mechanistic, bell-shaped, and plateau models were employed for these calculations provided that organ-specific parameters were available for the subsequent assessment of the excess absolute risk (EAR) for second cancer development. The estimated organ-specific lifetime risks were compared with the respective nominal intrinsic probabilities for cancer induction. Results: The mean OED, which was calculated from the patients’ treatment plans, varied from 0.54 to 6.61 Gy by the partially in-field organ of interest and the model used for dosimetric calculations. The difference between the OED of liver derived from the mechanistic model with those from the bell-shaped and plateau models was less than 1.8%. An even smaller deviation of 1.0% was observed for colon. For the rest organs of interest, the differences between the OED values obtained by the examined models varied from 8.6% to 50.0%. The EAR for stomach, colon, liver, pancreas, and kidney cancer induction at an age of 70 yr because of treatment of a typical 39-yr-old individual was up to 4.24, 11.39, 0.91, 3.04, and 0.14 per 10 000 persons-yr, respectively. Patient’s irradiation was found to elevate the lifetime intrinsic risks by 8.3%–63.0% depending upon the organ of interest and the model employed for risk analysis. Conclusions: Radiotherapy for stage I seminoma of the testis may result in an excess risk for the appearance of secondary malignancies in partially in-field organs. The organ- and model-dependent second cancer risk assessments of this study may be of value for patient counseling and follow-up.

60 APPLIED LIFE SCIENCES↗

SU-F-J-169: A Feasibility Study of Using MRI Alone in Abdominal Radiotherapy

Purpose: To demonstrate the feasibility of a MRI alone workflow to support treatment planning and image guidance for abdominal radiotherapy. Methods: Abdominal MR images (in-phase/out-phase/fat/water) were acquired for a patient with breath-hold using a Dixon pulse sequence. Air masks were created on in-phase images using intensity thresholding and morphological processing methods in order to separate air from bone. Pseudo-CT and DRRs were generated using a published method. To investigate the effect of heterogeneity corrections on dose calculations using pseudo-CT, three different plans (3-field 3D, 5-field IMRT and 2-arc VMAT) were performed to mimic pancreatic treatments (1.8Gy/fraction over 28 fractions). Results: The DRRs created from pseudo-CT were of comparable quality as those created from CT. Comparing dose calculations with and without heterogeneity corrections between the 3 different plans, the biggest dosimetric differences were seen in the VMAT plan where modulation must occur across air-tissue interfaces such as those of the stomach and bowel. The DVHs for the VMAT plan showed ∼84cc difference at V50Gy in the small bowel. In terms of pseudo-CT quality, some small volumes of air in the bowel and stomach were misclassified as bone. The VMAT plan was re-optimized on pseudo-CT with 0 HU in the misclassified areas. The V50Gy in the small bowel differed by ∼90cc between the new VMAT plan with and without heterogeneity corrections. Conclusion: We found that the use of MRI alone is feasible for abdominal treatment planning and image guidance. A difference between calculations with and without heterogeneity corrections was found that is most pronounced for VMAT where the traversal of air-tissue interfaces is unavoidable. Future work will be performed to minimize misclassification between bone and air.

60 APPLIED LIFE SCIENCES↗

Distal Pancreatectomy With En Bloc Resection of the Celiac Trunk for Extended Pancreatic Tumor Disease: An Interdisciplinary Approach

Purpose: Infiltration of the celiac trunk by adenocarcinoma of the pancreatic body has been considered a contraindication for surgical treatment, thus resulting in a very poor prognosis. The concept of distal pancreatectomy with resection of the celiac trunk offers a curative treatment option but implies the risk of relevant hepatic or gastric ischemia. We describe initial experiences in a small series of patients with left celiacopancreatectomy with or without angiographic preconditioning of arterial blood flow to the stomach and the liver. Materials and Methods: Between January 2007 and October 2009, six patients underwent simultaneous resection of the celiac trunk for adenocarcinoma of the pancreatic body involving the celiac axis. In four of these cases, angiographic occlusion of the celiac trunk before surgery was performed to enhance collateral flow from the gastroduodenal artery. Radiologic and surgical procedures, findings, and outcome were analyzed retrospectively. Results: Complete tumor removal (R0) succeeded in two patients, whereas four patients underwent R1-tumor resection. After surgery, one of the two patients without angiographic preparation experienced an ischemic stomach perforation 1 week after surgery. The other patient died from severe bleeding from an ischemic gastric ulcer. Of the four patients with celiac trunk embolization, none presented ischemic complications after surgery. Mean survival was 371 days. Conclusion: In this small series, ischemic complications after celiacopancreatectomy occurred only in those patients who did not receive preoperative celiac trunk embolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic body radiation therapy planning with duodenal sparing using volumetric-modulated arc therapy vs intensity-modulated radiation therapy in locally advanced pancreatic cancer: A dosimetric analysis

Stereotactic body radiation therapy (SBRT) achieves excellent local control for locally advanced pancreatic cancer (LAPC), but may increase late duodenal toxicity. Volumetric-modulated arc therapy (VMAT) delivers intensity-modulated radiation therapy (IMRT) with a rotating gantry rather than multiple fixed beams. This study dosimetrically evaluates the feasibility of implementing duodenal constraints for SBRT using VMAT vs IMRT. Non–duodenal sparing (NS) and duodenal-sparing (DS) VMAT and IMRT plans delivering 25 Gy in 1 fraction were generated for 15 patients with LAPC. DS plans were constrained to duodenal D{sub max} of<30 Gy at any point. VMAT used 1 360° coplanar arc with 4° spacing between control points, whereas IMRT used 9 coplanar beams with fixed gantry positions at 40° angles. Dosimetric parameters for target volumes and organs at risk were compared for DS planning vs NS planning and VMAT vs IMRT using paired-sample Wilcoxon signed rank tests. Both DS VMAT and DS IMRT achieved significantly reduced duodenal D{sub mean}, D{sub max}, D{sub 1cc}, D{sub 4%}, and V{sub 20} {sub Gy} compared with NS plans (all p≤0.002). DS constraints compromised target coverage for IMRT as demonstrated by reduced V{sub 95%} (p = 0.01) and D{sub mean} (p = 0.02), but not for VMAT. DS constraints resulted in increased dose to right kidney, spinal cord, stomach, and liver for VMAT. Direct comparison of DS VMAT and DS IMRT revealed that VMAT was superior in sparing the left kidney (p<0.001) and the spinal cord (p<0.001), whereas IMRT was superior in sparing the stomach (p = 0.05) and the liver (p = 0.003). DS VMAT required 21% fewer monitor units (p<0.001) and delivered treatment 2.4 minutes faster (p<0.001) than DS IMRT. Implementing DS constraints during SBRT planning for LAPC can significantly reduce duodenal point or volumetric dose parameters for both VMAT and IMRT. The primary consequence of implementing DS constraints for VMAT is increased dose to other organs at risk, whereas for IMRT it is compromised target coverage. These findings suggest clinical situations where each technique may be most useful if DS constraints are to be employed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of a high-throughput method for processing sponge-stick samples to detect viable, non-spore-forming biothreat agents

After a bioterrorism incident, surface sampling is often used to determine the extent of contamination and exposure, guiding decontamination efforts and decisions for re-occupancy of affected sites. The sponge-stick (SS) is a preferred and commonly used device for sample collection to detect both spore-forming and non-spore-forming biothreat agents from non-porous surfaces. Here, in this study, a recently developed high-throughput method (HTM) for processing SS samples to detect viable Bacillus anthracis spores was adapted for detection of non-spore-forming biothreat agents, Yersinia pestis and Francisella tularensis. The scalable HTM was used to process up to 20 SS samples simultaneously, compared to the current stomacher-based method which processes one SS at a time. Comparisons of the HTM and the stomacher-based method were statistically indistinguishable for most experiments (P > 0.05) with HTM recoveries of 37–60 % for Y. pestis inoculated at 102–103 cells/SS and held 48 h at 4 °C to mimic sample transport/storage. The HTM was integrated with Rapid Viability-Polymerase Chain Reaction (RV-PCR) analysis to detect viable Y. pestis in the presence of particulate contamination (Arizona Test Dust, ATD). This approach detected Y. pestis inoculated at 20 cells/SS and ATD did not impact detection (P > 0.05). F. tularensis showed significantly lower recoveries between no-hold time and 48-h hold time (4 °C, P < 0.05) using the HTM, which further testing showed could be due to toxicity of the neutralizing buffer used for SS pre-wetting. With modifications, this method could enhance throughput capacity while maintaining similar recovery efficiencies to current methods for other non-spore-forming bacterial pathogens.

Biological and medical sciences↗

Juvenile Steelhead Distribution, Migration, Feeding, and Growth in the Columbia River Estuary, Plume, and Coastal Waters

Abstract Relative to extensive research on the freshwater stages of steelhead Oncorhynchus mykiss life history, little is known about the species' estuarine and early marine phases despite the decline of numerous populations, including several from the Columbia River. Comparisons of the distribution, diet, and growth of juvenile steelhead collected during surveys of the Columbia River estuary and coastal waters in May, June, and September 1998–2011 were analyzed for comparisons between fish caught in the estuary and ocean and between hatchery (marked) and putative wild (unmarked) fish. Almost all catches of juvenile steelhead in the ocean occurred during the May surveys (96%). Juvenile steelhead were consistently caught at the westernmost stations (>55 km from shore), indicating an offshore distribution. Based on otolith structure and chemistry, we determined that these juveniles had been in marine waters for an average of only 9.8 d (SD = 10.2). Some of the steelhead that had been in marine waters for 1–3 d were captured at the westernmost edge of survey transects, indicating rapid offshore migration. Estuary caught fish ate fewer prey types and consumed far less food than did ocean caught fish, which ate a variety of prey, including juvenile fishes, euphausiids, and crab megalopae. Estuary and ocean caught unmarked fish exhibited higher feeding intensities, fewer empty stomachs, and better condition than hatchery fish. Growth hormone levels (insulin like growth factor 1 [IGF 1]) in unmarked fish and hatchery fish varied annually, with unmarked fish having slightly higher overall values. In general, the FL, condition, stomach fullness, and IGF 1 of ocean caught steelhead increased with distance offshore. Unlike juveniles of other salmonid species, steelhead appeared to quickly migrate westward from coastal rivers and showed patterns of increased feeding and growth in offshore waters. An understanding of the estuarine and ocean ecology of steelhead smolts may assist in the management of threatened steelhead populations. Received July 18, 2013; accepted November 21, 2013

Daly, Elizabeth A.↗

Endoluminal ultrasound applicators for MR-guided thermal ablation of pancreatic tumors: Preliminary design and evaluation in a porcine pancreas model

Purpose: Endoluminal ultrasound may serve as a minimally invasive option for delivering thermal ablation to pancreatic tumors adjacent to the stomach or duodenum. The objective of this study was to explore the basic feasibility of this treatment strategy through the design, characterization, and evaluation of proof-of-concept endoluminal ultrasound applicators capable of placement in the gastrointestinal (GI) lumen for volumetric pancreas ablation under MR guidance. Methods: Two variants of the endoluminal applicator, each containing a distinct array of two independently powered transducers (10 × 10 mm 3.2 MHz planar; or 8 × 10 × 20 mm radius of curvature 3.3 MHz curvilinear geometries) at the distal end of a meter long flexible catheter assembly, were designed and fabricated. Transducers and circulatory water flow for acoustic coupling and luminal cooling were contained by a low-profile polyester balloon covering the transducer assembly fixture. Each applicator incorporated miniature spiral MR coils and mechanical features (guiding tips and hinges) to facilitate tracking and insertion through the GI tract under MRI guidance. Acoustic characterization of each device was performed using radiation force balance and hydrophone measurements. Device delivery into the upper GI tract, adjacent to the pancreas, and heating characteristics for treatment of pancreatic tissue were evaluated in MR-guided ex vivo and in vivo porcine experiments. MR guidance was utilized for anatomical target identification, tracking/positioning of the applicator, and MR temperature imaging (MRTI) for PRF-based multislice thermometry, implemented in the real-time RTHawk software environment. Results: Force balance and hydrophone measurements indicated efficiencies of 48.8% and 47.8% and −3 dB intensity beam-widths of 3.2 and 1.2 mm for the planar and curvilinear transducers, respectively. Ex vivo studies on whole-porcine carcasses revealed capabilities of producing ablative temperature rise (ΔT > 15 °C) contours in pancreatic tissue 4–40 mm long and 4–28 mm wide for the planar transducer applicator (1–13 min sonication duration, ∼4 W/cm{sup 2} applied acoustic intensity). Curvilinear transducers produced more selective heating, with a narrower ΔT > 15 °C contour length and width of up to 1–24 mm and 2–7 mm, respectively (1–7 min sonication duration, ∼4 W/cm{sup 2} applied acoustic intensity). Active tracking of the miniature spiral coils was achieved using a Hadamard encoding tracking sequence, enabling real-time determination of each coil’s coordinates and automated prescription of imaging planes for thermometry. In vivo MRTI-guided heating trials in three pigs demonstrated capability of ∼20 °C temperature elevation in pancreatic tissue at 2 cm depths from the applicator, with 5–7 W/cm{sup 2} applied intensity and 6–16 min sonication duration. Dimensions of thermal lesions in the pancreas ranged from 12 to 28 mm, 3 to 10 mm, and 5 to 10 mm in length, width, and depth, respectively, as verified through histological analysis of tissue sections. Multiple-baseline reconstruction and respiratory-gated acquisition were demonstrated to be effective strategies in suppressing motion artifacts for clear evolution of temperature profiles during MRTI in the in vivo studies. Conclusions: This study demonstrates the technical feasibility of generating volumetric ablation in pancreatic tissue using endoluminal ultrasound applicators positioned in the stomach lumen. MR guidance facilitates target identification, device tracking/positioning, and treatment monitoring through real-time multislice PRF-based thermometry.

60 APPLIED LIFE SCIENCES↗