At least 73 records · Page 4

Implementation and validation of optimal start control strategy for air conditioners and heat pumps

Commercial buildings are responsible for approximately 20 % of the total energy consumption and greenhouse gas emissions in the United States. Over 85 % of these buildings lack building automation systems, and many are small (<50,000 square feet), underserved, and use rooftop units (RTUs) for heating, ventilation, and air-conditioning needs. Because these buildings lack proper energy management systems, several operational deficiencies lead to excess energy consumption. Studies have shown that managing the RTUs’ heating and cooling set points, schedules, setbacks, and optimal start can result in a 20 % to 25 % reduction in electricity consumption in small commercial buildings. These buildings typically use fixed schedules to start the RTUs 60 to 120 min before occupancy begins, which results in excess energy consumption. This paper presents research that demonstrates and evaluates the performance of four optimal start methods, which utilize data-based modeling as a key element in facilitating adaptive control in response to time-varying inputs while requiring minimal sensor inputs. The evaluation found energy savings in two commercial buildings equipped with RTUs by periodically alternating four different optimal start models during the cooling and heating season. The resulting energy savings are positive for all models and range from 2 to 5 kWh/day/unit. The units on the east side of the building showed higher savings, while interior units showed greater variability in savings due to the differences in capacities and room sizes. Savings were considerably greater during the heating season compared to the cooling season. The performance of all four models on Mondays was poor; models suggested a shorter optimal start time, which resulted in relatively larger errors. Finally, the future work will look at using a different model for the days after weekends and holidays.

42 ENGINEERING↗

Characterization of commercial vehicles’ start-up operations from in-use data

Diesel engines produce disproportionate levels of emissions when the engine and after-treatment systems are operating at low temperatures. This situation arises most commonly when the vehicle is first started after overnight. To quantify emissions attributable to vehicle starts, a sizable collection of on-road commercial vehicle operating data is analyzed to identify start-up events and inspect associated emissions. Data was obtained from the National Renewable Energy Laboratory’s (NREL’s) Fleet DNA and from the Center for Environmental Research & Technology (CE-CERT). Included are 500 + diesel vehicles with more than 42,000 recorded days, drawn from 25 vocational categories across the United States. Analysis shows that vehicle behavior, in terms of engine cold- and warm-operation, starts per day, soak time, and warm-up duration, differs significantly between vehicle vocations. Also, weighting factors for cold- and hot-starts currently used in the U.S. Environmental Protection Agency’s Federal Test Procedure (FTP) for heavy-duty emissions certification accurately represent real-world operations. Although the FTP includes a comparable fraction of cold operation, the hot fraction is much shorter than real-world operation due to limited test duration. The investigation also revealed that real-world engines operate for a significant amount of time when the engine coolant is in the “hot-stabilized” region, but the selective catalytic reduction (SCR) temperature is below its effective operating temperature of 200 °C. Of the vehicles under investigation, almost 20% of their operational time is within this condition. Therefore, novel approaches to raise and maintain SCR temperature are highly required to further reduce engine emissions.

33 ADVANCED PROPULSION SYSTEMS↗

Efficient ECCD non-inductive plasma current start-up, ramp-up, and sustainment for an ST fusion reactor

The elimination of the need for an Ohmic heating solenoid may be the most impactful design driver for the realization of economical compact fusion tokamak reactor systems. However, this would require fully non-inductive start-up and current ramp-up from zero plasma current and low electron temperature of sub-keV to the full plasma current of ~10–15 MA at 20–30 keV electron temperature. To address this challenge, an efficient solenoid-free start-up and ramp-up scenario utilizing a low-field-side-launched extraordinary mode at the fundamental electron cyclotron harmonic frequency (X–I) is proposed, which has more than two orders of magnitude higher electron cyclotron current drive (ECCD) efficiency than the conventional ECCD for the sub-keV start-up regime. A time dependent model was developed to simulate the start-up scenarios. For the Spherical Tokamak Advanced Reactor (STAR) (Menard et al 2023 Next-Step Low-Aspect-Ratio Tokamak Design Studies (IAEA)), it was found that to fully non-inductively ramp-up to 15 MA, it would take about 25 MW of EC power at 170 GHz. Because of the relatively large plasma volume of STAR, radiation losses must be considered. It is important to make sure that high Z impurities are kept sufficiently low during the early current start-up phase where the temperature is sub-keV range. Since the initial current ramp up takes place at a factor of ten lower density compared to the sustained regimes, it is important to transition into a higher bootstrap fraction discharge at lower density to minimize the ECCD power requirement during the densification. For the sustainment phase an array of eight gyrotron launchers with a total of about 60 MW of fundamental O-mode was found to be sufficient to provide the required axis-peaked external current drive. High efficiencies between 19–57 kA MW –1 were found with optimal aiming, and these were resilient to small changes in aiming angles and density and temperature profiles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interval Between Hysterectomy and Start of Radiation Treatment Is Predictive of Recurrence in Patients With Endometrial Carcinoma

Purpose: Adjuvant radiation therapy (RT) has been shown to improve local control in patients with endometrial carcinoma. We analyzed the impact of the time interval between hysterectomy and RT initiation in patients with endometrial carcinoma. Methods and Materials: In this institutional review board-approved study, we identified 308 patients with endometrial carcinoma who received adjuvant RT after hysterectomy. All patients had undergone hysterectomy, oophorectomy, and pelvic and para-aortic lymph node evaluation from 1988 to 2010. Patients' demographics, pathologic features, and treatments were compared. The time interval between hysterectomy and the start of RT was calculated. The effects of time interval on recurrence-free (RFS), disease-specific (DSS), and overall survival (OS) were calculated. Following univariate analysis, multivariate modeling was performed. Results: The median age and follow-up for the study cohort was 65 years and 72 months, respectively. Eighty-five percent of the patients had endometrioid carcinoma. RT was delivered with high-dose-rate brachytherapy alone (29%), pelvic RT alone (20%), or both (51%). Median time interval to start RT was 42 days (range, 21-130 days). A total of 269 patients (74%) started their RT <9 weeks after undergoing hysterectomy (group 1) and 26% started ≥9 weeks after surgery (group 2). There were a total of 43 recurrences. Tumor recurrence was significantly associated with treatment delay of ≥9 weeks, with 5-year RFS of 90% for group 1 compared to only 39% for group 2 (P<.001). On multivariate analysis, RT delay of ≥9 weeks (P<.001), presence of lymphovascular space involvement (P=.001), and higher International Federation of Gynecology and Obstetrics grade (P=.012) were independent predictors of recurrence. In addition, RT delay of ≥9 weeks was an independent significant predictor for worse DSS and OS (P=.001 and P=.01, respectively). Conclusions: Delay in administering adjuvant RT after hysterectomy was associated with worse survival endpoints. Our data suggest that shorter time interval between hysterectomy and start of RT may be beneficial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The role of corporate investment in start-ups for climate-tech innovation

Enabling and accelerating the full potential of energy innovation is a critical component of the global policy response to climate change. Incentivizing start-ups advancing climate-tech (i.e., products and services related to clean energy and climate change), has become central to innovation policy because start-ups are nimble (compared to incumbents), can quickly focus on bringing new technologies to market, and simultaneously create new jobs and catalyze local industries. Public policies to support climate-tech start-ups and efforts such as Mission Innovation tend to focus on increasing government spending (e.g., grants for research and development) or on creating demand pull for new technologies (e.g., feed-in-tariffs). But to go from research and development to widespread adoption of new products and services, start-ups need to grow and scale, and this requires support from private investors. Yet, research on how different investors can shape the direction of climate innovation—and how public policy can incentivize private investment in climate-tech start-ups to support the public good—is surprisingly sparse.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Start current of dielectric-loaded grating in Smith-Purcell radiation

In this paper, a three-dimensional dielectric loaded grating (DLG) is proposed for the Smith-Purcell (SP) device. Taking into the considerations of thickness and width of electron beam, the dispersion equation is derived by using field matches method. The complex frequency is obtained by the numerical solution of dispersion equation, in which the imaginary part represents linear growth rate. The impacts of the electron beam filling factor (EBFF) on growth rate are discussed under the condition that the beam current and beam current density are kept as constants, respectively. In addition, the start current for SP oscillator is obtained by using the dispersion relation combined with boundary conditions. The relationship between the start current and other parameters is discussed and compared with the conventional metal grating. The results show that with the increasing of EBFF, the peak growth rate increases rapidly firstly and then decreases slowly, in which the current and current density are kept as constants, respectively. For the SP oscillator, the start current is increased with the shifting up beam voltage, but it is decreased with the improved EBFF, and only it has a slightly increasing trend when EBFF is close to 1. In addition, the start current is decreased with the increasing of relative dielectric constant, which indicates that by introducing DLG, the start current can be effectively reduced. Theoretical results are in good agreement with that of the simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Black Start with Inverter-Based Resources: Hardware Testing

Black start, or grid restoration after a wide-spread power outage, is a critical service on the power system that has historically been provided by transmission-connected synchronous generators. As the power system transitions to rely on more distributed and inverter-based resources it will be critical that these resources can also provide black start services. In this work we investigated battery energy storage and solar photovoltaics technical capabilities and limitations to provide black start services through hardware testing in an experimental microgrid testbed. This hardware demonstration of inverter-based resources providing black start functions can help inform grid operators on how to include these types of resources in their black start plans.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MSTL Re-Start Phase 1.5 Project Final Report

This document provides an overview of re-start efforts at Sandia National Laboratories (SNL), National Solar Thermal Test Facility (NSTTF), for the SNL Molten Salt Test Loop (MSTL). MSTL is one of the world’s only industrial-scale molten salt test systems, capable of testing commercial-scale thermal hydraulic equipment at an industrial scale, required for confident bankability of products. This work was facilitated as part of the Phase 1 re-start effort for facilitating forensics assessments to inform final refurbishments and upgrades costs and schedule information for revitalizing MSTL for use during a separate Phase 2 effort. This work was facilitated to further de-risk a Phase 2 effort pertaining to the tank and the pump, which were considered during Phase 1 to be high-risk items for a successful re-start. Impact from a successful re-start will allow SNL and other industrial molten salt systems companies, such as those in the Market Utilization Report provided in the Phase 1 submission package. An objective of this document is to also ensure longevity of utilization of MSTL after re start.

14 SOLAR ENERGY↗

The Effect of Spark-Plug Heat Dispersal Range and Exhaust Valve Opening Timing on Cold-Start Emissions and Cycle-to-Cycle Variability

The partnership for advancing combustion engines (PACE) is a US Department of Energy consortium involving multiple national laboratories and includes a goal of addressing key efficiency and emission barriers in light-duty engines fueled with a market-representative E10 gasoline. A major pillar of the initiative is the generation of detailed experimental data and modeling capabilities to understand and predict cold-start behavior. Cold-start, as defined by the time between first engine crank and three-way catalyst light-off, is responsible for a large percentage of NOx, unburned hydrocarbon and particulate matter emissions in light-duty engines. Minimizing emissions during cold-start is a trade-off between achieving faster light-off of the three-way catalyst and engine out emissions during that period. In this study, gaseous and soot emissions were measured at a distance representative of the three-way catalyst position downstream of the engine at a 2 bar net indicated mean effective pressure (NIMEP) steady-state operating condition representative of cold-start. The test matrix included sweeps of ignition timing 15 degrees-before to 10 degrees-after top dead center firing (TDCf) across three different spark-plug heat dispersal ranges (HR). Additionally, the effect of varying exhaust valve opening (EVO) timing on combustion stability and emissions was also studied. Results show that the spark plug HR affects the coefficient of variation (COV) of NIMEP under all cold-start conditions, while the impact on emissions was found to be minimal. At very retarded spark timings, colder spark plugs required higher air and fuel flow to maintain the desired 2bar NIMEP load, but the fraction of fuel energy going into the exhaust was found to be similar for all spark plugs. Finally, retarding exhaust valve timings showed a simultaneous reduction in emissions while increasing the fraction of fuel energy being fed into the exhaust. However, engine COV was also observed to increase with retarded exhaust timings.

42 ENGINEERING↗

Auto Stop-Start Fuel Consumption Benefits

With increasingly stringent regulations mandating the improvement of vehicle fuel economy, automotive manufacturers face growing pressure to develop and implement technologies that improve overall system efficiency. One such technology is an automatic (auto) stop-start feature. Auto stop-start reduces idle time and reduces fuel use by temporarily shutting the engine off when the vehicle comes to a stop and automatically re-starting it when the brake is released, or the accelerator is pressed. As mandated by the U.S. Congress, the U.S. Environmental Protection Agency (EPA) is required to keep the public informed about fuel saving practices. This is done, in partnership with the U.S. Department of Energy (DOE), through the fueleconomy.gov website. The “Fuel-Saving Technologies” and “Gas Mileage Tips” sections of the website are focused on helping the public make informed purchasing decisions and encouraging fuel-saving driving habits. Here, in order to provide users with accurate information about the auto stop-start feature, experiments were conducted to determine its fuel economy effect. Four vehicles were tested both with and without the feature enabled under three test cycles: the Federal Test Procedure (FTP) city fuel economy test, the US06 high acceleration aggressive driving schedule that is often identified as the “Supplemental FTP” driving schedule, and the EPA New York City Cycle (NYCC). The results were compared to measure the fuel economy and consumption effects of using the auto stop-start feature. It was found that the fuel economy improvement varied significantly between drive cycles depending on the amount and percentage of idle time during the test. The largest fuel economy improvements were 7.27% and 26.4% for the FTP and NYCC, respectively.

33 ADVANCED PROPULSION SYSTEMS↗

Gas-injection-start and shutdown characteristics of a 2-kilowatt to 15-kilowatt Brayton power system

Two methods of starting the Brayton power system have been considered: (1) using the alternator as a motor to spin the Brayton rotating unit (BRU), and (2) spinning the BRU by forced gas injection. The first method requires the use of an auxiliary electrical power source. An alternating voltage is applied to the terminals of the alternator to drive it as an induction motor. Only gas-injection starts are discussed in this report. The gas-injection starting method requires high-pressure gas storage and valves to route the gas flow to provide correct BRU rotation. An analog computer simulation was used to size hardware and to determine safe start and shutdown procedures. The simulation was also used to define the range of conditions for successful startups. Experimental data were also obtained under various test conditions. These data verify the validity of the start and shutdown procedures.

Cantoni, D. A.↗

Mach 4 free-jet tunnel starting experiments for a hypersonic research engine model causing high blockage

Tests of a full scale hypersonic research engine (HRE) were conducted in the hypersonic tunnel facility at Mach numbers of 5, 6, and 7. Since the HRE would cause a rather high blockage (48.83 percent of the nozzle area), subscale tests were conducted in various available small wind tunnels prior to the full scale tests to study the effects of model blockage on tunnel starting. The results of the Mach 4 subscale tests which utilized a model system at 0.0952 scale which simulated the HRE in the test section of the tunnel are presented. A satisfactory tunnel starting could not be achieved by varying the free jet length or diffuser size nor by inserting the model into the test stream after tunnel starting. However, the installation of a shroud around the HRE model allowed the tunnel to start with the model preset in the tunnel at a tunnel stagnation pressure to atmospheric exit pressure ratio of 13.4. The simulation of the discharge of instrumentation cooling water and the addition of test hardware at the aft end of the HRE model did not have a significant effect on the tunnel starting.

Carson, G. T., Jr.↗

Frozen start-up behavior of low-temperature heat pipes

Start-up and subsequent operation of a low-temperature heat pipe requires the liquid phase of the operating fluid to be continuously pumped back to the evaporator by the capillary action of the wick. If the pipe has been in an environment where ambient temperatures are below the freezing point of the working fluid prior to start-up, the frozen fluid in the condenser and adiabatic region scan prevent initial flow to the evaporator, causing dryout of the evaporator before all of the working fluid is in the liquid phase. This paper examines the time-dependent wall and vapor temperature profiles along the axial length of a low-temperature heat pipe during start-up from the frozen state, and freeze-out during a normal operation by applying a subfreezing temperature fluid through the condenser. In addition, the experimental transient frozen start-up wall temperature profile is compared with a two-dimensional numerical phase-change model. A successful start-up method using a pulsed power input is presented.

Faghri, Amir↗

Dynamic Modeling of Starting Aerodynamics and Stage Matching in an Axi-Centrifugal Compressor

A DYNamic Turbine Engine Compressor Code (DYNTECC) has been modified to model speed transients from 0-100% of compressor design speed. The impetus for this enhancement was to investigate stage matching and stalling behavior during a start sequence as compared to rotating stall events above ground idle. The model can simulate speed and throttle excursions simultaneously as well as time varying bleed flow schedules. Results of a start simulation are presented and compared to experimental data obtained from an axi-centrifugal turboshaft engine and companion compressor rig. Stage by stage comparisons reveal the front stages to be operating in or near rotating stall through most of the start sequence. The model matches the starting operating line quite well in the forward stages with deviations appearing in the rearward stages near the start bleed. Overall, the performance of the model is very promising and adds significantly to the dynamic simulation capabilities of DYNTECC.

Wilkes, Kevin↗

START Analysis for ESAS Capability Needs Prioritization

START is a tool to optimize research and development primarily for NASA missions. It was developed within the Strategic Systems Technology Program Office, a division of the Office of the Chief Technologist at NASA's Jet Propulsion Laboratory. START is capable of quantifying and comparing the risks, costs, and potential returns of technologies that are candidates for funding. START can be enormously helpful both in selecting technologies for development -- within the constraints of budget, schedule, and other resources -- and in monitoring their progress. START's methods are applicable to everything from individual tasks to multiple projects comprising entire programs of investigation. They can address virtually any technology assessment and capability prioritization issue. In this report, START is used to analyze the capability needs using data from NASA's Exploration Systems Architecture Study (ESAS).

optimization↗

Improved Starting Materials for Back-Illuminated Imagers

An improved type of starting materials for the fabrication of silicon-based imaging integrated circuits that include back-illuminated photodetectors has been conceived, and a process for making these starting materials is undergoing development. These materials are intended to enable reductions in dark currents and increases in quantum efficiencies, relative to those of comparable imagers made from prior silicon-on-insulator (SOI) starting materials. Some background information is prerequisite to a meaningful description of the improved starting materials and process. A prior SOI starting material, depicted in the upper part the figure, includes: a) A device layer on the front side, typically between 2 and 20 m thick, made of p-doped silicon (that is, silicon lightly doped with an electron acceptor, which is typically boron); b) A buried oxide (BOX) layer (that is, a buried layer of oxidized silicon) between 0.2 and 0.5 m thick; and c) A silicon handle layer (also known as a handle wafer) on the back side, between about 600 and 650 m thick. After fabrication of the imager circuitry in and on the device layer, the handle wafer is etched away, the BOX layer acting as an etch stop. In subsequent operation of the imager, light enters from the back, through the BOX layer. The advantages of back illumination over front illumination have been discussed in prior NASA Tech Briefs articles.

Pain, Bedabrata↗

Variations in Sleep and Performance by Duty Start Time in Short Haul Operations

Prior studies have confirmed that commercial airline pilots experience circadian phase shifts and short sleep duration following travel with layovers in different time zones. Few studies have examined the impact of early and late starts on the sleep and circadian phase of airline pilots who return to their domicile after each duty period. We recruited 44 pilots (4 female) from a short-haul commercial airline to participate in a study examining sleep and circadian phase over four duty schedules (baseline, early starts, mid-day starts, late starts). Each duty schedule was five days long, separated by three rest days. Participants completed the rosters in the same order. Sleep outcomes were estimated using wrist-borne actigraphy (Actiware Software, Respironics, Bend, OR) and daily sleep diaries. Thirteen participants volunteered to collect urine samples for the assessment of 6-sulfatoxymelatonin (aMT6s). Urine samples were collected in four-hourly bins during the day and eight-hourly bins during sleep episodes, for 24 hours immediately following each experimental duty schedule. The aMT6s results were fit to a cosine in order to obtain the acrophase to estimate circadian phase. Univariate statistics were calculated for acrophase changes, schedule start times and sleep times. All statistical analyses were computed using SAS software (Cary, IN).

fatigue↗

Synchronous motor with soft start element formed between the motor rotor and motor output shaft to successfully synchronize loads that have high inertia and/or high torque

A line-start synchronous motor has a housing, a rotor shaft, and an output shaft. A soft-start coupling portion is operatively coupled to the output shaft and the rotor shaft. The soft-start coupling portion is configurable to enable the synchronous motor to obtain synchronous operation and to drive, at least near synchronous speed during normal steady state operation of the motor, a load having characteristics sufficient to prevent obtaining normal synchronous operation of the motor when the motor is operatively connected to the load in the absence of the soft-start coupling. The synchronous motor is sufficiently rated to obtain synchronous operation and to drive, at least near synchronous speed during normal steady state operation of the motor, a load having characteristics sufficient to prevent obtaining normal synchronous operation of the motor when the motor is operatively connected to the load in the absence of the soft-start coupling.