Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STABLE BEAMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

First Results of the IOTA Ring Research at Fermilab

The IOTA ring at Fermilab is a unique machine exclusively dedicated to accelerator beam physics R&D. The research conducted at IOTA includes topics such as nonlinear integrable optics, suppression of coherent beam instabilities, optical stochastic cooling and quantum science experiments. In this talk we report on the first results of experiments with implementations of nonlinear integrable beam optics. The first of its kind practical realization of a two-dimensional integrable system in a strongly-focusing storage ring was demonstrated allowing among other things for stable beam circulation near or at the integer resonance. Also presented will be the highlights of the world’s first demonstration of optical stochastic beam cooling and other selected results of IOTA’s broad experimental program.

43 PARTICLE ACCELERATORS↗

Recent studies of the electron cloud induced beam instability at the Los Alamos PSR

Recent beam studies have focused on two aspects of the observed e-p instability at the Los Alamos Proton Storage Ring (PSR). Most recently it has been observed that a stable beam with the standard production bunch width (290 ns injected beam bunch width) will become e-p unstable when the bunch width is shortened to 200 ns or less. This was not the case years earlier when the ring RF operated at the exact 72.000 sub harmonic of the Linac bunch frequency. Experimental characteristics and possible explanations of this recent ''short pulse instability phenomenon'' will be presented. Other beam studies have focused on electron cloud generation, trapping and ejection from quadrupoles and are the focus of another talk. (auth)

43 PARTICLE ACCELERATORS↗

Multi-cusp ion source for Gen 5.5 doping system

A multi-cusp ion source was designed for Nissin ion doping system 'iG5' developed for GEN5.5 processes. It has many points of similarity to iG4 ion source. The extraction area and the internal volume of the plasma chamber are scaled up. And the method to obtain high current B{sup +} beams is same as iG4 ion source. On the other hand, iG5 ion source has an added feature on the extraction system. We use new developed multi-slit extraction system to obtain stable beams with small divergence. The target boron beam current density of 1mA/cm (that is 130mA) was obtained.

36 MATERIALS SCIENCE↗

First operation of the charge-breeder electron-cyclotron-resonance ion source at the Texas A and M Cyclotron Institute

The 14.5 GHz electron-cyclotron-resonance ion source (ECRIS) designed and fabricated specifically for charge breeding has been installed at the Texas A and M University Cyclotron Institute for use in the institute's ongoing radioactive-ion-beam upgrade. The initial testing of the source has just begun with magnetic analysis of the ECRIS beam. The source has only been conditioning for a brief time at low microwave power, and it is continuing to improve. After the source has been conditioned and characterized, charge-breeding trials with stable beams from a singly ionizing source will begin.

43 PARTICLE ACCELERATORS↗

SU-E-T-220: Investigation of Intrafraction Changes to Photon Beam Profiles

Purpose: Treatment Planning Systems model beam profiles to be static and independent of gantry angle. This work investigates how beam profiles change over time, with varying gantry angle. Methods: 200 cGy was delivered to ICProfiler (Sun Nuclear) on 2 Elekta Synergys and 1 Varian 21EX linacs at 8 gantry angles and 1 clockwise arc. Measurements were recorded 8 times per second. To investigate the initial portion of the beams, single-shot and multi-control-point beams were measured. The differences in beam profiles were analyzed as well as the length of time for the beam to stabilize. Symmetry was calculated 5cm from the central axis at 100cm SSD. Field sizes ranged from 30×30 cm{sup 2} to 40×40 cm{sup 2}. Results: The beam profiles changed over time and were dependent on gantry angle. The composite profile for each beam met 1% tolerance described in TG-142. It took up to 14.7, 3.7 and 11.3 cGy for the two Elektas and Varian respectively to satisfy the tolerance. All linacs had the most flat, symmetric, and stable beam profile with the gantry at 0 degrees, where the symmetry was 100.5%±0.55, 101.0%±0.52 and 101.1%±0.44 respectively. The symmetry was 100.7%±1.06, 101.1%±1.05 and 101.2%±0.64 at the gantry angle with the biggest discrepancy (90, 180 and 180 degrees respectively). Symmetry was better in the X direction for the Elektas and the Y for the Varian. Fluctuations in beam profiles corresponded to changes in dose rate. Conclusion: Flatness and symmetry changed over time and with gantry angle. Because Treatment Planning Systems do not account for these changes, it may be necessary to limit certain beams from clinical use, for example, beams with low MU. It may also be necessary to add additional QA procedures beyond those suggested in TG-142 to account for these changes.

07 ISOTOPE AND RADIATION SOURCES↗

CHICO2, a two-dimensional pixelated parallel-plate avalanche counter

CHICO 2 (Compact Heavy Ion COunter), is a large solid-angle, charged-particle detector array developed to provide both θ and Φ angle resolutions matching those of GRETINA (Gamma-Ray Energy Tracking In-beam Nuclear Array). CHICO 2 was successfully tested at the Argonne National Laboratory where it was fielded as an auxiliary detector with GRETINA for γ-ray spectroscopic studies of nuclei using a 252 Cf spontaneous fission source, stable beams, and radioactive beams from CARIBU. In field tests of the 72,76Ge beams on a 0.5 mg/cm 2 208Pb target at the sub-barrier energy, CHICO 2 provided charged-particle angle resolutions (FWHM) of 1.55° in θ and 2.47° in Φ. This achieves the design goal for both coordinates assuming a beam-spot size (>3 mm) and the target thickness (>0.5 mg/cm 2 ). The combined angular resolution of GRETINA/CHICO 2 resulted in a Doppler-shift corrected energy resolution of 0.60% for 1 MeV coincident de-excitation γ-rays. This is nearly a factor of two improvements in resolution and sensitivity compared to Gammasphere/CHICO. Kinematically-coincident detection of scattered ions by CHICO 2 still maintains the mass resolution (ΔM/M) of ~5% that enhanced isolation of scattered weak beams of interest from scattered contaminant beams.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Family of L-band SRF Cavities for High Power Proton Driver Applications

Recent global interest in high duty factor or CW superconducting linacs with high average beam power highlights the need for robust and reliable SRF structures capable of delivering high average RF power to the beam with moderate HOM damping, low interception of halo and good efficiency. Potential applications include proton or H- drivers for spallation neutron sources, neutrino physics, waste transmutation, subcritical reactors, and high-intensity high-energy physics experiments. We describe a family of SRF cavities with a range of Betas capable of transporting beam currents in excess of 10 mA CW with large irises for minimal interception of halo and HOM and power couplers capable of supporting high average power operation. Goals include an efficient cell shape, high packing factor for efficient real-estate gradient and strong HOM damping to ensure stable beam operation,

43 PARTICLE ACCELERATORS↗

Projectile fragmentation of radioactive beams of {sup 68}Ni, {sup 69}Cu, and {sup 72}Zn

The fragment production cross sections of secondary neutron-rich beams of {sup 68}Ni, {sup 69}Cu, and {sup 72}Zn isotopes at energies of about 95A MeV have been measured. We compare the measured cross sections to EPAX, an empirical parametrization of fragmentation cross sections. A reasonable agreement of the experimental data and EPAX predictions suggests that an EPAX parametrization used for stable beams seems to be valid for unstable neutron-rich ion beams. EPAX tends to overestimate the yields of neutron-rich isotopes. This problem is amplified when neutron-rich radioactive beams are employed, leading to overly optimistic estimates of the production of neutron-rich isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast ion stabilization of tilt in large radius FRCs

The field reversed configuration (FRC) has been a curious case in plasma physics research in that early MHD analysis suggested FRCs should be grossly unstable, while experimental results contradicted that prediction. Later, this theory was able to resolve this contradiction by understanding that finite Larmor radius effects largely negated the MHD predictions. Similarly, previous theoretical studies of beam driven FRCs predicted that such system would be unstable to beam driven modes while, again, experimental results indicated the contradiction. In this paper, we reconcile the theoretical understanding of beam driven modes with experimental observations of stability in these systems. By self-consistently capturing fast ion generation from neutral beam injection and its impact on the plasma equilibrium, we show that low amplitude perturbations in the magnetic field, driven by betatron particles, modify the precession frequencies of the betatron particles such that the drive for compressional Alfvén waves in the thermal plasma is reduced. Finally, we are able to demonstrate, for the first time, stable beam driven FRC evolution at high S*/E in 3D kinetic simulations.

Betatrons↗

CHICOX, a heavy-ion detection system for GRETA

The CHICOX detection system is an array of position sensitive parallel plate avalanche counters used for heavy ion detection in in-beam particle-gamma coincidence experiments. CHICOX, an upgrade of the CHICO2 array, is geometrically compatible with the GRETINA and GRETA gamma-ray arrays and provides an angular resolution sufficient to utilize the excellent position resolution of GRETINA/GRETA. CHICOX was successfully commissioned and fielded as an auxiliary detector to GRETINA in a campaign of stable-beam Coulomb excitation experiments at the ATLAS facility of Argonne National Laboratory. We report here on the design and in-beam performance of the CHICOX array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applications of electron lenses: scraping of high-power beams, beam-beam compensation, and nonlinear optics

Electron lenses are pulsed, magnetically confined electron beams whose current-density profile is shaped to obtain the desired effect on the circulating beam. Electron lenses were used in the Fermilab Tevatron collider for bunch-by-bunch compensation of long-range beam-beam tune shifts, for removal of uncaptured particles in the abort gap, for preliminary experiments on head-on beam-beam compensation, and for the demonstration of halo scraping with hollow electron beams. Electron lenses for beam-beam compensation are being commissioned in the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Laboratory (BNL). Hollow electron beam collimation and halo control were studied as an option to complement the collimation system for the upgrades of the Large Hadron Collider (LHC) at CERN; a conceptual design was recently completed. Because of their electric charge and the absence of materials close to the proton beam, electron lenses may also provide an alternative to wires for long-range beam-beam compensation in LHC luminosity upgrade scenarios with small crossing angles. At Fermilab, we are planning to install an electron lens in the Integrable Optics Test Accelerator (IOTA, a 40-m ring for 150-MeV electrons) as one of the proof-of-principle implementations of nonlinear integrable optics to achieve large tune spreads and more stable beams without loss of dynamic aperture.

43 PARTICLE ACCELERATORS↗

Characteristics of the positive ion source at reduced gas feed

The neutral beam injector of steady state superconducting tokamak (SST1-NBI) at IPR is designed for injecting upto 1.7 MW of neutral beam (Hº, 30–55 keV) power to the tokamak plasma for heating and current drive. Operations of the positive ion source (PINI or Plug-In-Neutral-Injector) of SST1-NBI were carried out on the NBI test stand. The PINI was operated at reduced gas feed rate of 2–3 Torr l/s, without using the high speed cryo pumps. Experiments were conducted to achieve a stable beam extraction by optimizing operational parameters namely, the arc current (120–300 A), acceleration voltage (16–40 kV), and a suitable control sequence. The beam divergence, power density profiles, and species fractions (H{sup +}:H{sub 2}{sup +}:H{sub 3}{sup +}) were measured by using the diagnostics such as thermal calorimetry, infrared thermography, and Doppler shift spectroscopy. The maximum extracted beam current was about 18 A. A further increase of beam current was found to be limited by the amount of gas feed rate to the ion source.

43 PARTICLE ACCELERATORS↗

Status of PLS-II Upgrade Program

The Pohang Light Source (PLS) at the Pohang Accelerator Laboratory has been operated first at 2.0 GeV since 1995, and later was upgraded to 2.5 GeV. During this time, 6 insertion devices like undulators and multipole wigglers have been put into operation to produce special photon beams, with a total of 27 beamlines installed and 3 beamlines under construction. Recently, Korea synchrotron user's community is demanding high beam stability, higher photon energies as well as more straight sections for insertion devices in the PLS. To meet the user requirements, the PLS-II upgrade program has been launched in January, 2009, incorporating a modified chromatic version of Double Bend Achromat (DBA) to achieve almost twice as many straight sections as the current PLS with a design goal of the relatively low emittance, {epsilon}, of 5.9 nm{center_dot}rad. In the PLS-II, the top-up injection using full energy linac is planned for much higher stable beam as well and thus the production of hard x-ray undulator radiation of 8 to 13 keV is anticipated to allow for the successful research program namely Protein Crystallography. The PLS-II machine components of storage ring, linear accelerator and photon beamlines will be partly dismantled and reinstalled in a 6-months shutdown beginning January, 2011 and then the PLS-II upgrade be started the initial commissioning with a 100 mA beam current from July in 2011.

43 PARTICLE ACCELERATORS↗

The FRIB Decay Station: New Horizons with Rare Isotopes

In May 2022, the Facility for Rare Isotope Beams (FRIB), located on the campus of Michigan State University (MSU), began delivering exotic isotopes to an international community of scientists. New discoveries are now being reported from radioactive decay of neutron-rich nuclei near N = 20 and N = 28.FRIB is expected to produce roughly 80% of the unstable or radioactive isotopes predicted to exist up to uranium (Z = 92). The new user facility is supported by the U.S. Department of Energy, and it is operated by MSU. A high-power superconducting linear accelerator, shaped like a paper-clip, drives the production of these rare isotopes by colliding stable nuclei moving at half the speed of light with a rotating, water-cooled graphite tar-get. These collisions cause the primary stable beam to fragment into a wide variety of unstable nuclei, which can be subsequently filtered through a multistage magnetic separator, the Advanced Rare Isotope Separator, and transported to one of several experimental stations. The FRIB Decay Station initiator (FDSi) (see Figure 1) was developed to enable comprehensive radio-active decay studies of the exotic nuclei produced by FRIB and it was used in the first two experiments in 2022. Further, the FDSi is a highly reconfigurable multidetector system with two focal planes (FP1 for discrete spectroscopy and FP2 for total absorption spectroscopy) that can be optimized for the specific science goals of each experiment. It is designed, built, and operated by a community of users with the sup-port of U.S. funding agencies, including the Department of Energy and National Science Foundation.

07 ISOTOPE AND RADIATION SOURCES↗

Automated RF Phase Adjustment for Beam Stabilization in the Fermilab Linac

The Fermilab Linac experiences longitudinal beam phase drift, leading to increased particle loss, conventionally corrected through labor-intensive manual RF adjustments. This project explores machine learning-based automation for drift correction, employing a prototype-based classification approach. Our model utilizes a 34-dimensional feature set (RF settings and BPM readings) and leverages a 7x27 response matrix for system modeling. To overcome limited real-world data, we generate synthetic data, enhancing model training and generalizability. Custom loss functions, including a surrogate energy-consistent loss and a temporal smoothness constraint, ensure physically plausible drift predictions. The goal is a robust system for autonomous phase adjustments, ensuring stable beam acceleration and reduced manual intervention.

Chichili, R. R. [Illinois U., Chicago]↗

Automated RF Phase Adjustment for Beam Stabilization in the Fermilab Linac

The Fermilab Linac experiences longitudinal beam phase drift, leading to increased particle loss, conventionally cor- rected through labor-intensive manual RF adjustments. This project explores machine learning-based automation for drift correction, employing a prototype-based classification approach. Our model utilizes a 34-dimensional feature set (RF settings and BPM readings) and leverages a 7x27 response matrix for system modeling. To overcome limited real-world data, we generate synthetic data, enhancing model training and generalizability. Custom loss functions, including a sur- rogate energy-consistent loss and a temporal smoothness constraint, ensure physically plausible drift predictions. The goal is a robust system for autonomous phase adjustments, ensuring stable beam acceleration and reduced manual intervention.

Chichili, R. R. [U. Illinois, Chicago]↗

MTOF - A High Resolution Isobar Separator for Studies of Exotic Decays

A compact high resolution, isobar separator, based on the Multi-pass-Time-of-Flight (MTOF) principle, is being built by the University Radioactive Ion Beam (UNIRIB) Consortium. MTOF as a spectroscopy tool will have the capability to suppress a contaminating nuclear species with a relative mass difference of M/dM > 40,000 by a factor of >> 100. MTOF has high transmission (20% - 50%), is not chemistry dependent and fast (2-10 milliseconds of analysis time per ion bunch of {approx} 10{sup 4} ions). The commissioning of and first experiments with MTOF will take place at the UNISOR mass separator of HRIBF, which acts as a low resolving power pre-separator. At this location, MTOF will provide isobarically pure samples of nuclei for decay spectroscopy produced in fusion-evaporation reactions with stable beams from the 25-MV tandem accelerator or by fission of UC. MTOF is capable of providing isobarically pure samples of all masses. Initially, our experimental program will focus on the region around 100Sn.

43 PARTICLE ACCELERATORS↗

Systematic analysis of above-barrier fusion of {sup 9,10,11}Be+{sup 209}Bi

Measurements of fusion for {sup 9,10,11}Be allow testing of the relative importance to fusion and breakup of the alpha-cluster structure found in all these Be isotopes, compared with the neutron-halo structure only present for {sup 11}Be. However, disagreements exist among different published experimental data sets for the reactions of {sup 9,10,11}Be with {sup 209}Bi. Accurate measurements of above-barrier cross sections for the products of complete fusion (fission and evaporation residues) in the reaction of {sup 9}Be with {sup 209}Bi and {sup 208}Pb provide the basis for a reanalysis of above-barrier fusion for {sup 10,11}Be+{sup 209}Bi. This includes procedures making full use of the higher precision stable beam data and resolves many of the disagreements. The improved self-consistency of the analysis allows investigation of the experimental average fusion barriers. Although showing some scatter, these suggest a higher barrier for the neutron halo nucleus {sup 11}Be. Comparison of published cross sections for fusion associated with capture of all the charge of the projectile suggest that all these Be isotopes show significant suppression of complete fusion, a surprising result given that the alpha-breakup threshold energies are 1.57 MeV for {sup 9}Be but over 7 MeV for {sup 10,11}Be. Further experimental studies to investigate in more detail the division between complete and incomplete fusion for reactions of {sup 10,11}Be are needed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗