Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SPECTROPHOTOMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Using PCDS to study the influence of UV flux variation on the middle atmosphere

The value of the Pilot Climate Data System (PCDS) in examining the influences of short-period solar flux variations on the middle atmosphere was demonstrated. Several Nimbus satellite data sets proposed for the study exist in the PCDS. Planned for retrieval through the PCDS are ozone mixing ratios and cumulative ozone profiles available from the Backscatter Ultraviolet Spectrophotometer on Nimbus-4. Also to be accessed are Nimbus-7 data sets that will provide ozone and nitrogen dioxide mixing ratios, temperature profiles from the Limb Infrared Monitor of the Stratosphere, and ozone mixing ratio profiles from the Solar Backscatter Ultraviolet Spectrophotometer. Bypassing the time-consuming process of reading raw data tapes, the researchers plan to transfer the PCDS processed data to an IBM PC at Iowa State University. The IBM PC will serve as an intermediate vehicle for transferring the data to the NOAA CYBER 840 at Boulder, Colorado, where research will continue on both an eight-layer radiative-photochemical numerical model and on a nonlinear dynamical model. in this research are the FGGE and ERB data sets. These relevant data sets also reside in the PCDS. Problems associated with remote access to the PCDS were discussed in regard to all the PCDS data sets.

Heilman, W.↗

The observed distribution of atmospheric ozone and its variations

It is pointed out that both the total amount and the vertical distribution of atmospheric ozone are presently measured routinely by various ground-based and satellite-borne instruments and by instruments mounted on different carrier platforms such as balloons, aircraft, and rockets. The techniques of observing atmospheric ozone are discussed, taking into account the determination of total ozone, the Dobson spectrophotometer, the Brewer spectrophotometer, the M-83 Filter Ozonometer, and satellite techniques. In a discussion of studies of vertical distribution, remote systems are considered along with in situ measurements. Attention is given to ground-based methods, satellite platforms, backscatter measurements, limb observations, electrochemical methods, chemiluminescent methods, optical methods, and rocket observations. A number of graphs showing the observed distribution of atmospheric ozone are also presented, and changes in this distribution are evaluated.

London, J.↗

Wavelength tunable liquid crystal imaging filters for remote sensing from geosynchronous platforms

Recent advances in liquid crystal technology have enabled us to construct tunable birefringent filters with bandwidths between approximately 0.1 nm and 50 nm. The center wavelength of these filters can be selected electronically, in a few tens of milliseconds, with no moving parts. These liquid crystal tunable filters (LCTF's), together with existing CCD detectors, make possible a new generation of lightweight, rugged, high-resolution imaging spectrophotometers. Such instruments would be particularly interesting for remote sensing applications from geosynchronous platforms. Important advantages exist in the aperture, absence of image shift, power consumption, size, weight, and absence of high drive frequencies, compared to current instruments used or considered for multispectral scene analysis. In the present work, we have reviewed spectral requirements of planned NASA geosynchronous remote sensing missions and identified several applications of the liquid crystal tunable filter technology. We have modeled the LCTF performance in the visible and near-infrared, and carried out a literature study on space-hardening of the filter components, to evaluate the suitability of LCTF's for geosynchronous missions. We have also compared the power consumption, weight, size, reliability, and optical performance of an imaging spectrophotometer using a LCTF monochromator, to other instruments that have been put forward for remote sensing from geosynchronous platforms. We put forward some conceptual designs for LCTF's that seem to offer important reliability, over the mechanical filter wheels presently baselined for the HEPI and ALM experiments. The extremely wide acceptance angle achievable with LCTF's could also avoid the present need for large-aperture interference filters in the ALM (and LIS) experiments. Thermal vacuum testing and radiation damage analysis is required to investigate the space hardening of these new filters for geosynchronous flight.

Foukal, Peter↗

The Coronal Ultraviolet Berkeley Spectrometer (CUBS)

We describe an instrument package to remotely measure thermospheric, exospheric, and plasmaspheric structure and composition. This instrument was flown aboard the second test flight of the Black Brant XII sounding rocket on December 5, 1989, which attained an apogee of 1460 km. The experiment package consisted of a spectrophotometer to measure He I 584 A, O II 834 A, O I 989 A, hydrogen Lyman beta (1025 A), hydrogen Lyman alpha (1216 A), and O I 1304 A transitions, and a photometer to measure the He II 304 A emission. The optical design of the spectrophotometer was identical to that of the Berkeley Extreme Ultraviolet (EUV) Airglow Rocket Spectrometer payload, flown on September 30, 1988 aboard the maiden flight of the Black Brant XII rocket. We present the initial data analysis and describe directions we will go toward the completion of our study.

Bush, Brett C.↗

Differences between recalculated and original Dobson total ozone data from Hradec Kralove, Czechoslovakia, 1962-1990

Backward reevaluation of long-term total ozone measurements from the Solar and Ozone Observatory of Czech Hydrometeorological Institute at Hradec Kralove, Czechoslovakia, was performed for the period 1962-1990. The homogenization was carried out with respect to the calibration level of the World Primary Standard Spectrophotometer No. 83 - WPSS by means of day-by-day recalculations of more than 25,000 individual measurements using the R-N tables reconstructed after international comparisons and regular standard lamp tests of the Dobson spectrophotometer No. 74. The results showed significant differences among the recalculated data and those original ones published in the bulletins Ozone Data for the World. In the period 1962-1979 they reached 10-19 D.U. (3.0-5.5%) for annual averages and even 26 D.U. (7.0%) for monthly averages of total ozone. Such differences exceed several times accuracy of measuring and can significantly influence character of trends of total ozone in Central Europe. Therefore the results from Hradec Kralove support the calls for reevaluation of all historical Dobson total ozone data sets at individual stations of Global Ozone Observing System.

Vanicek, Karel↗

Comparison of recalculated Dobson and TOMS total ozone at Hradec Kralove, Czechoslovakia, 1978-1990

The reevaluated Dobson total ozone data from Hradec Kralove, Czechoslovakia were compared with independent Total Ozone Mapping Spectrophotometer (TOMS) 'version 6' data set. The comparison was performed by means of the parallel daily averages of ground-based and satellite total ozone pairs of the period November 1978 to December 1990. The comparison showed slight differences between both data series. Their average relative difference is 0.48 percent. The similar results have been reached for subsets of direct sun and zenith types of measurements as well. Their relative differences are 0.61 percent and 0.11 percent respectively. These facts indicate not only good mutual relation of both data sources but also reliability and accuracy of the zenith charts of the spectrophotometer No. 74 used at Hradec Kralove. Preliminary assessment of seasonal MU-dependence of the differences between Dobson and TOMS data was made while using total ozones of winter and summer months representing values of MU=2.70-5.20 and MU = 1.12-1.30 respectively. The results did not show systematic underestimation or overestimation of total ozone due to MU-dependence of the instrument at Hradec Kralove in both seasons.

Stanek, Martin↗

UV-B radiation amplification factor determined based on the simultaneous observation of total ozone and global spectral irradiance

The Japan Meteorological Agency started the spectral observation of solar ultraviolet (UV) irradiance on 1 January 1990 at Tateno, Aerological Observatory in Tsukuba (35 deg N, 140 deg E). The observation has been carried out using the Brewer spectrophotometer for the wavelengths from 290 to 325 nm with a 0.5 nm interval every hour from 30 minutes before sunrise to 30 minutes after sunset throughout a year. Because of remarkable similarity within observed spectra, an observed spectrum can be expressed by a simple combination of a reference spectrum and two parameters expressing the deformation of the observed spectrum from the reference. By use of the relation between one of the deformation parameters and the total ozone simultaneously observed with the Dobson spectrophotometer, the possible increase of UV irradiance due to ozone depletion is estimated. For damaging UV, the irradiance possibly increases about 19 percent with the ozone depletion of 10 percent at noon throughout the year in the northern midlatitudes. DUV at noon on the summer solstice possibly increases about 5.6 percent with the ozone depletion of 10 m atm-cm for all latitudes in the Northern Hemisphere.

Ito, T.↗

SPEAM-II experiment for the measurement of stratospheric NO2, O3 and aerosols

Following the success of the Sunphotometer Earth Atmosphere Measurement (SPEAM-I) experiment, a more involved experiment was developed to fly as part of the second set of Canadian Experiments (CANEX-2) which will fly on the US Space Shuttle in the fall of 1992. The instrument complement includes an IBM-PC compatible control computer, a hand-held diode array spectrophotometer, and an interference-filter, limb imaging radiometer for the measurement of the atmospheric airglow. The hand-held spectrometer will measure nitrogen dioxide, ozone and aerosols. The limb imaging radiometer will observe emissions from the O2(1 DELTA) and O2(1 SIGMA) airglow bands. Only the spectrophotometer will be discussed here.

Mcelroy, C. T.↗

Estimates of Spectral UV Irradiance from Earth Probe TOMS: Comparisons with Ground-Based Measurements

Estimates of the spectral UV flux incident on the Earth's surface are calculated based on total column ozone and cloud optical thickness determined from the Earth Probe Total Ozone Mapping Spectrometer (TOMS) satellite data. Spectral fluxes are calculated between 300 and 325 nanometers using a weighting function similar to the measured function of the Brewer Spectrophotometer. Comparisons of the TOMS-derived values with ground-based Brewer Spectrophotometer measurements at 3 locations from the Canadian Brewer network (Toronto, Saskatoon and Saturna Island) and 3 locations from the United States EPA network (Boston, Gaithersburg, and Boulder) show reasonably good agreement over a variety of clear and cloudy conditions. Some systematic differences are apparent, particularly when snow/ice is present and the TOMS instrument cannot distinguish between clouds and snow covered ground, thus leading to an underestimation of UV flux. The presence of absorbing aerosols near the ground or sub-pixel clouds can also lead to significant errors. There are also possible errors in the Brewer data due to radiometric calibration uncertainties and uncorrected cosine response.

Labow, G. J.↗

Continuous pH monitoring in a perfused bioreactor system using an optical pH sensor

Monitoring and regulating the pH of the solution in a bioprocess is one of the key steps in the success of bioreactor operation. An in-line optical pH sensor, based on the optical absorption properties of phenol red present in the medium, was developed and tested in this work for use in NASA space bioreactors based on a rotating wall-perfused vessel system supporting a baby hamster kidney (BHK-21) cell culture. The sensor was tested over three 30-day and one 124-day cell runs. The pH sensor initially was calibrated and then used during the entire cell culture interval. The pH reported by the sensor was compared to that measured by a fiber optically coupled Shimadzu spectrophotometer and a blood gas analyzer. The maximum standard error of prediction for all the four cell runs for development pH sensor against BGA was +/-0.06 pH unit and for the fiber optically coupled Shimadzu spectrophotometer against the blood gas analyzer was +/-0.05 pH unit. The pH sensor system performed well without need of recalibration for 124 days. Copyright 2002 Wiley Periodicals, Inc.

Bioreactors↗

The 825-1110 angstroms EUV spectrum of Venus

On 15 August 1994 we launched the EUVS sounding rocket payload to observe the 825-1110 angstrom region of Venus's far ultraviolet airglow spectrum. The EUVS telescope/spectrograph obtained good data at five times higher spectral resolution than was previously available in the far ultraviolet. We present these data and compare our results to those obtained by the Galileo UVS and Venera 11/12 UV spectrophotometers. We identify several new spectral emission features, including both singly ionized nitrogen and molecular nitrogen in Venus's spectrum. We also see evidence for electron-impact-induced emission from CO. Finally, the EUVS data indicate that the "Ar" emissions detected in Venus's far ultraviolet spectrum by Venera 11/12 spectrophotometers are in fact not due to argon, thus eliminating the discrepancy between in situ and remote sensing measurements.

Flight Experiment↗

Non-Intrusive Techniques of Inspections During the Pre-Launch Phase of Space Vehicle

This paper addresses a method of non-intrusive local inspection of surface and sub-surface conditions, interfaces, laminations and seals in both space vehicle and ground operations with an integrated suite of imaging sensors during pre-launch operations. It employs an advanced Raman spectrophotometer with additional spectrophotometers and lidar mounted on a flying robot to constantly monitor the space hardware as well as inner surface of the vehicle and ground operations hardware. This paper addresses a team of micro flying robots with necessary sensors and photometers to monitor the entire space vehicle internally and externally. The micro flying robots can reach altitude with least amount of energy, where astronauts have difficulty in reaching and monitoring the materials and subsurface faults. The micro flying robot has an embedded fault detection system which acts as an advisory system and in many cases micro flying robots act as a Supervisor to fix the problems. As missions expand to a sustainable presence in the Moon, and extend for durations longer than one year in lunar outpost, the effectiveness of the instrumentation and hardware has to be revolutionized if NASA is to meet high levels of mission safety, reliability, and overall success. The micro flying robot uses contra-rotating propellers powered by an ultra-thin, ultrasonic motor with currently the world's highest power weight ratio, and is balanced in mid-air by means of the world's first stabilizing mechanism using a linear actuator. The essence of micromechatronics has been brought together in high-density mounting technology to minimize the size and weight. The robot can take suitable payloads of photometers, embedded chips for image analysis and micro pumps for sealing cracks or fixing other material problems. This paper also highlights advantages that this type of non-intrusive techniques offer over costly and monolithic traditional techniques.

Thirumalainambi, Rejkumar↗

Characteristics of In Situ Fine Fraction Aerosol Spectra from 300-700 nm Observed Around the Korean Peninsula During KORUS-OC

In situ aerosol extinction and absorption spectra covering the 300-700 nm range at ≤ 1 nm spectral resolution were measured aboard the R/V Onnuri during the Korea U.S. – Ocean Color (KORUS-OC) cruise around the Korean Peninsula from May 21 through June 3, 2016. Total absorption spectra were obtained from aerosols collected on glass fiber filters and subsequently placed in the center of an integrating sphere (Labsphere DRA-CA-30) attached to a dual beam spectrophotometer (Cary 100 Bio UV-Visible Spectrophotometer, 0.2 nm spectral resolution). Absorption spectra from methanol and deionized water extracts of aerosols collected on Teflon filters were measured in a liquid waveguide capillary cell (World Precision Instruments LWCC- 3100, ~0.4 nm spectral resolution). Extinction spectra were measured with a custom built instrument (SpEx, ~0.8 nm spectral resolution). The measurements were obtained at a height of ~10 m above the sea surface with an inlet that limited the measured aerosols to diameters ≤ 1.3 µm. All four sets of spectra exhibit curvature in log-log space with 2nd order polynomials providing a better fit to the measured spectra than power law fits. The deionized water extracts were also analyzed with an ion chromatograph (Dionex ICS-3000 Ion Chromatography System) and with an aerosol mass spectrometer (Aerodyne Research, Inc. HR-ToF High Resolution Aerosol Mass Spectrometer) to examine chemical composition. These data indicate the optical spectra are sensitive to differing chemical properties of the measured ambient aerosols and suggest differing sources and/or atmospheric processes influence the observed optical signatures. The measured suite of spectra are combined to examine the spectral characteristics of single scattering albedo, as well as to examine the contribution of soluble absorbing chromophores to the total absorption spectra. Additional measurements made during the affiliated Korea U.S. - Air Quality (KORUS-AQ) campaign will be used to provide further insight on the observed spectral characteristics.

Jordan, Carolyn E↗

Calculated Transmission Using a Portable Spectroreflectometer

Under normal circumstances, a spectrophotometer is used to measure transmission of material samples. However, a sample may be too large to fit into the spectrophotometer chamber, or a field inspection may be required. This Technical Publication describes the procedure for using measurements made with a portable spectroreflectometer to calculate transmission. A similar procedure is used to calculate infrared transmission using measurements from a portable infrared reflectometer.

Finckenor, M. M.↗

BioSensor Users' Guide

The BioSensor is a fully autonomous 3-color LED-based spectrophotometer paired with a fluidics system that supports microbes in liquid culture. Originally developed for the BioSentinel CubeSat mission to study the response of a wild type and mutant strain of yeast to the deep space environment, the BioSensor consists of a series of 16-well, independently plumbed fluidics cards. The cards utilize filters to allow the fluidic system to administer reagents while constraining the microbes in their wells. Heaters on each card incubate to the appropriate growth temperature once the experiment begins. During the active experiment, the LED/detector system measures the transmission of light through each well at three specific wavelengths, similar to a standard benchtop spectrophotometer. The transmission/absorbance kinetics curves for each well are telemetered back to Earth, along with temperature data, for analysis on the ground. The BioSensor is being upgraded from its original CubeSat free-flyer interface to be a secondary payload on lunar landers, Gateway, and other BLEO applications, while maintaining the same functionality and science utility for future experiments.

Matthew Lera↗

BioSensor Users' Guide

The BioSensor is a fully autonomous 3-color LED-based spectrophotometer paired with a fluidics system that supports microbes in liquid culture. Originally developed for the BioSentinel CubeSat mission to study the response of a wild type and mutant strain of yeast to the deep space environment, the BioSensor consists of a series of 16-well, independently plumbed fluidics cards. The cards utilize filters to allow the fluidic system to administer reagents while constraining the microbes in their wells. Heaters on each card incubate to the appropriate growth temperature once the experiment begins. During the active experiment, the LED/detector system measures the transmission of light through each well at three specific wavelengths, similar to a standard benchtop spectrophotometer. The transmission/ absorbance kinetics curves for each well are telemetered back to Earth, along with temperature data, for analysis on the ground. The BioSensor is being upgraded from its original CubeSat free-flyer interface to be a secondary payload on lunar landers, Gateway, and other BLEO applications, while maintaining the same functionality and science utility for future experiments.

Matthew Lera↗