Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SPECTRAL EMISSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The cathode-fall of low-pressure hydrogen discharges: Absolute spectral emission and model

Absolute excitation probabilities from very low to moderate-current hydrogen discharges in parallel-plane geometry are measured and used to test models. Relative emission data are obtained for the H{sub {alpha}} line, the H{sub 2} (a{sup 3}{Sigma}{yields}b{sup 3}{Pi}) near-UV continuum, and the H{sub 2} (G{sup 1}{Sigma}{yields}B{sup 1}{Pi}{sub u}{sup +}) band at pressures of 0.5 and 2 Torr, a 1.05 cm gap, and voltages from 300 to 900 V. Electron behavior is traced using the first negative (A{sup 2}{Sigma}{sub g}{yields} X{sup 2}{Pi}{sub u}, {nu}'' = 0 {yields}{nu}' = 0) band of N{sub 2}{sup +} by adding 2% N{sub 2}. Relative measurements of H{sub {alpha}}, H{sub 2} near-UV, and N{sub 2} 1st negative emission are placed on a absolute scale by normalization to published measurements and Boltzmann calculations of electron excitation. Emission probabilities calculated using a multi-beam kinetics model for the electrons, H{sup +}, H{sub 2}{sup +}, H{sub 3}{sup +}, H{sup -}, H, and H{sub 2} are compared with the calibrated experiments. Fast H atoms are calculated to produce H{sub {alpha}} excitation that is comparable with that of electrons. The calculated emission intensities for H{sub {alpha}} and H{sub 2} near-UV continuum are within a factor of three of the absolute measurements for a range of 5000:1 in current and 4:1 in hydrogen pressure. Calculations at 2 Torr show that most of the space charge electric field responsible for the cathode fall is produced by H{sub 3}{sup +} ions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectral emission measurements of lithium on the lithium tokamak experiment

There has been a long-standing collaboration between ORNL and PPPL on edge and boundary layer physics. As part of this collaboration, ORNL has a large role in the instrumentation and interpretation of edge physics in the lithium tokamak experiment (LTX). In particular, a charge exchange recombination spectroscopy (CHERS) diagnostic is being designed and undergoing staged testing on LTX. Here we present results of passively measured lithium emission at 5166.89 A in LTX in anticipation of active spectroscopy measurements, which will be enabled by the installation of a neutral beam in 2013. Preliminary measurements are made in transient LTX plasmas with plasma current, I{sub p} < 70 kA, ohmic heating power, P{sub oh}{approx} 0.3 MW and discharge lifetimes of 10-15 ms. Measurements are made with a short focal length spectrometer and optics similar to the CHERS diagnostics on NSTX [R. E. Bell, Rev. Sci. Instrum. 68(2), 1273-1280 (1997)]. These preliminary measurements suggest that even without the neutral beam for active spectroscopy, there is sufficient passive lithium emission to allow for line-of-sight profile measurements of ion temperature, T{sub i}; toroidal velocity and v{sub t}. Results show peak T{sub i} = 70 eV and peak v{sub t} = 45 km/s were reached 10 ms into the discharge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A sensitive search for unknown spectral emission lines in the diffuse X-ray background with XMM-Newton

The Standard Model of particle physics can be extended to include sterile (right-handed) neutrinos or axions to solve the dark matter problem. Depending upon the mixing angle between active and sterile neutrinos, the latter have the possibility to decay into monoenergetic active neutrinos and photons in the keV-range while axions can couple to two photons. We have used data taken with the X-ray telescope XMM-Newton for the search of line emissions. We used pointings with high exposures and expected dark matter column densities with respect to the dark matter halo of the Milky Way. The posterior predictive p-value analysis has been applied to locate parameter space regions which favour additional emission lines. In addition, upper limits of the parameter space of the models have been generated such that the preexisting limits have been significantly improved.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spectral emissivity of metals after damage by particle impact

The reflectance, R, solar absorption, alpha, thermal emittance epsilon, and the alpha/epsilon ratio were determined for several metals before and after bombardment by high velocity microprojectiles. Observed decreases of 1 to 26 percent in the reflectance of various metals were apparently dependent on the amount of surface area damaged as well as on the velocity of the impinging projectiles. The thermal emittance was observed to increase more than the solar absorptance, which resulted in a net decrease in the alpha/epsilon ratio in all metals investigated except stainless steel 304. In the case of stainless steel 304, alpha and epsilon were observed to increase equally, resulting in an alpha/epsilon ratio apparently insensitive to microprojectile bombardment. Recommendations for the continuation of these investigations are outlined.

Laszlo, T. S.↗

Spectral emission of nuclear excited XeBr*

The vacuum-ultraviolet spectroscopy system and MCFIG capsule were filled with a He-3:Ar:Xe:Br (534:195:12:6) torr mixture and irradiatied by a CW flux of 17 x 10 to the 11th power neutrons/sq cm sec. The XeBr* emission was observed, but the Br2 emission normally observed in argon-bromine mixtures predominates. This spectrum is typical of these mixtures with XeBr* probably peaking with 0.1 percent Bromine in 2 atmosphere argon with 2 percent xenon. The addition of a large partial pressure of He-3 produces additional unknowns. The typical vibrational structure of XeBr* was not observed. Sapphire emission continuums were present. Energy deposition was 0.43 watts and the capsule output under the XeBr* and Br2 bands was 0.0016 watts, giving an efficiency of 0.37 percent.

Walters, R. A.↗

Measuring the spectral emissivity of thermal protection materials during atmospheric reentry simulation

Hypersonic spacecraft reentering the earth's atmosphere encounter extreme heat due to atmospheric friction. Thermal Protection System (TPS) materials shield the craft from this searing heat, which can reach temperatures of 2900 F. Various thermophysical and optical properties of TPS materials are tested at the Johnson Space Center Atmospheric Reentry Materials and Structures Evaluation Facility, which has the capability to simulate critical environmental conditions associated with entry into the earth's atmosphere. Emissivity is an optical property that determines how well a material will reradiate incident heat back into the atmosphere upon reentry, thus protecting the spacecraft from the intense frictional heat. This report describes a method of measuring TPS emissivities using the SR5000 Scanning Spectroradiometer, and includes system characteristics, sample data, and operational procedures developed for arc-jet applications.

Marble, Elizabeth↗

Seasonal Surface Spectral Emissivity Derived from Terra MODIS Data

The CERES (Clouds and the Earth's Radiant Energy System) Project is measuring broadband shortwave and longwave radiances and deriving cloud properties form various images to produce a combined global radiation and cloud property data set. In this paper, simultaneous data from Terra MODIS (Moderate Resolution Imaging Spectroradiometer) taken at 3.7, 8.5, 11.0, and 12.0 m are used to derive the skin temperature and the surface emissivities at the same wavelengths. The methodology uses separate measurements of clear sky temperature in each channel determined by scene classification during the daytime and at night. The relationships between the various channels at night are used during the day when solar reflectance affects the 3.7- m radiances. A set of simultaneous equations is then solved to derive the emissivities. Global monthly emissivity maps are derived from Terra MODIS data while numerical weather analyses provide soundings for correcting the observed radiances for atmospheric absorption. These maps are used by CERES and other cloud retrieval algorithms.

Sun-Mack, Sunny↗

Directional spectral emissivity measurement system

Apparatus and process for determining the emissivity of a test specimen including an integrated sphere having two concentric walls with a coolant circulating therebetween, and disposed within a chamber which may be under ambient, vacuum or inert gas conditions. A reference sample is disposed within the sphere with a monochromatic light source in optical alignment therewith. A pyrometer is in optical alignment with the test sample for obtaining continuous test sample temperature measurements during a test. An arcuate slit port is provided through the spaced concentric walls of the integrating sphere with a movable monochromatic light source extending through and movable along the arcuate slit port. A detector system extends through the integrating sphere for continuously detecting an integrated signal indicative of all radiation within its field of view, as a function of the emissivity of the test specimen at various temperatures and various angle position of the monochromatic light source. A furnace for heating the test sample to approximately 3000 K. and control mechanism for transferring the heated sample from the furnace to the test sample port in the integrating sphere is also contained within the chamber.

Halyo, Nesim↗

Chemical composition of Luna 16 lunar regolith

Data on the chemical composition of regolith returned by the Luna 16 automatic station and two fragments of basalts from the lower layer of the core are presented. Spark mass spectrometric, primary X-ray spectral, emission spectral, and atomic absorption methods were used in the analysis. The regolith of mare provinces were shown to be a mixture of material of various origins. The source of the material of the mare regolith was principally basalts of the corresponding lunar lava maria. The regolith is genetically related to it. This follows from a comparison of the chemical composition, mineralogical, and petrochemical features of the basesalts and the regolith from the Sea of Fertility, Sea of Tranquillity, and Ocean of Storms, respectively.

Vinogradov, A. P.↗

Improved Determination of Surface and Atmospheric Temperatures Using Only Shortwave AIRS Channels

The Goddard DAAC has been analyzing AIRS/AMSU sounding data using the AIRS Science Team Version 5 retrieval algorithm. The AIRS Version 5 retrieval algorithm produces significantly better temperature profiles under more difficult cloud conditions than does the AIRS Version 4 algorithm, because, following theoretical considerations, it employs 15 micron CO2 tropospheric sounding channels only for the purpose of generating cloud cleared radiances for all AIRS channels, and determines temperature profiles using only 4.2 micron AIRS observations. This approach works equally well during both daytime and night time conditions. The AIRS Version 6 retrieval algorithm takes this approach one step further, and now also determines surface skin temperatures over both land and ocean, using only shortwave AIRS window channel cloud cleared radiances. Shortwave surface spectral emissivity and spectral bi-directional reflectance are solved for simultaneously along with the surface skin temperature. Longwave surface spectral emissivity is determined in a subsequent step using only AIRS longwave window channels, using the previously determined surface skin temperature. The methodology to do this will be described, and results will be presented demonstrating significant improvement in retrieved surface skin temperatures and surface spectral emissivities compared to those obtained using Version 5, both day and night.

Susskind, Joel↗

Surface emissivity of a reinforced carbon composite material with an oxidation-inhibiting coating

Total effective emissivity and spectral emissivity over the wavelength range of 0.65 to 6.3 microns were determined for temperatures from 1300 t0 2250 deg K. A multi channel radiometer was used in the arcjet and laboratory tests. The black-body-hole method was used to independently check radiometer results. The results show the silicon-carbide coated reinforced carbon composite material is a nongray radiator. The total effective emissivity and the spectral emissivity at 0.65 micron both decreased with increasing temperature, respectively, from approximately 0.8 to 0.6, and from 0.4 to 0.25, over the temperature range. The emissivity values were the same when the sample was viewed normal to the surface or at a 45 deg angle. Recommended emissivity values are presented.

Wakefield, R. M.↗

Spectral imaging of the 3.3 and 11.3 micron emission bands in NGC 1333 - Discovery of spatially separate band emissions

Spectral images in the 3.3 and 11.3 micron IR emission band around the star SVS 3 in NGC 1333 indicate that the two bands have their origin in different locations, rendering them useless in estimates of the sizes of the molecules emitting the bands. This is in keeping with the emission bands' generation by a mixture of variously sized polycyclic aromatic hydrocarbons (PAHs) whose smallest species have been dehydrogenated in the vicinity of SVS 3. Hot bands and overtone/combination bands may account for the 3.4-micron band, rather than molecular side-groups of the PAHs.

Bregman, Jesse↗

Heuristic modeling of spectral plasma emission for laser-induced breakdown spectroscopy

A heuristic model was developed to describe the spectral emission of laser-induced plasmas generated for laser-induced breakdown spectroscopy under the assumption that the composition of the plasma and the plasma state is known. The plasma is described by a stationary spherical shell model surrounded by an ambient gas, which partially absorbs the emitted radiation. The radiation transport equation is used to calculate the spectrum emitted by the plasma. Simulations of a multiline iron spectrum and a self-reversed Al line are compared with experimental spectra. For the iron spectrum, the degree of congruence is moderate to good, which may be attributed to a lack of precise atomic and Stark broadening data as well as a simplified plasma model. The line profile of the Al resonance line with self reversal can be simulated with a high degree of agreement. Simulated spectra of a steel sample in the vacuum ultraviolet spectral range demonstrate the strong influence of the ambient atmosphere in the spectral range between 178 and 194 nm. The number of free parameters of the plasma model of 8 can be further reduced down to 3, taking into account the integral parameters of the plasma that are accessible experimentally.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗