Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SMART”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A MINi Powder INjector (MINPIN) for the SMART tokamak

Here, this article presents the design and performance characterization of a MINi Powder INjector (MINPIN) developed for boron wall conditioning (boronization) in the SMall Aspect Ratio Tokamak (SMART) at the University of Seville, Spain. SMART studies positive and negative triangularity plasmas within the low aspect ratio range of 1.4 < R/a < 3, with a major radius (R) of 0.40–0.60 m and a minor radius (a) of 0.20–0.33 m. MINPIN, in design, will gravitationally deliver boron (B) powder into the plasma, which ablates and transports the injected material. Mounted on the top of the vessel, the MINPIN will drop controlled amounts of powder using a piezoelectric blade driven by a signal generator that vibrates at a set frequency. The B will then be deposited in a layer on SMART’s stainless steel vacuum vessel walls, and this boronization process reduces the influx of intrinsic wall impurities, such as oxygen, carbon, nitrogen, and iron, which radiate power and cool the plasma. In the laboratory, we calibrated the drop rate for 1–10 mg/s, which will enable controlled boronization coating while achieving efficient powder ablation. We propose MINPIN’s operational scenarios based on the calibrated drop rate and estimated drop duration, assuming the distance from MINPIN to SMART’s plasmas.

Boron powder↗

Quantum Key Distribution Applicability to Smart Grid Cybersecurity Systems

To meet the increasing demand for electricity and to have a more reliable and resilient electric grid against conventional and extreme events, grid modernization is more crucial now than ever before. This will require the development and deployment of devices that provide advanced communication capabilities. The overall efficiency, reliability, and resilience of the smart grid will be inextricably linked to the exchange of information between these devices. Unfortunately, the increased information flow will increase the potential attack surface and introduce new vulnerabilities. While a smarter grid will depend critically on information flow, these benefits will be accrued only if that information can be protected. Nowadays, information is secured in smart grids primarily through cryptography. However, with the increasing number of sophisticated attacks as well as the increasing computational power, the security of the “classical” cryptographic algorithms is threatened. Quantum information science offers solutions to this problem, specifically quantum key distribution (QKD), which provides a means for the generation and secure distribution of symmetric cryptographic keys. The security of QKD stems ultimately from the very nature of quantum physics. In this paper, we investigate the applicability of QKD to the various smart grid sectors and specific use cases. We have identified 18 smart grid use cases of interest for QKD suitability together with 7 QKD factors used for the assessment of the various use cases. For each use case, the impact to security of the loss of confidentiality, integrity, and/or availability is specified. In addition, the suitability of QKD is assessed for each use case with respect to multiple factors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bat Smart Curtailment: Efficacy and Operational Testing

Curtailment, or blanket curtailment, is a leading method to mitigate the impacts to bats from operating wind turbines. Although this strategy results in considerable decreases in bat fatalities, it also results in decreased energy production. In 2019, Natural Power was awarded funding by the Department of Energy to assess the readiness of the informed smart curtailment technology, EchoSense (formerly referred to as Detection and Active Response Curtailment, [DARC]). The research undertaken by this project expands the understanding of alternative methods, known as smart curtailment, to maintain a reduction in bat fatalities while simultaneously recovering lost energy associated with blanket curtailment. The overall project was composed of three major tasks; Task 1 was focused on cybersecurity compliance of the EchoSense system in accordance with the North American Electric Reliability Corporation Critical Infrastructure Protection (“NERC CIP”) standards, Task 2 assessed the mechanical loads exerted on turbines when operating under a smart curtailment regime, and Task 3 assessed the efficacy of the EchoSense system at an operational wind farm. Regarding Task 1, an external review by the National Renewable Energy Laboratory determined that the EchoSense system did not create any new cybersecurity weaknesses and was compliant with the NERC CIP standards. As a result of this process, Natural Power developed some best practices (10.1) for wind- wildlife technology developers. In conjunction with the National Renewable Energy Laboratory, the results (10.2) of the loads testing demonstrated that the periodic curtailment and release of turbines by the EchoSense system did not have any detrimental impact on the mechanical components of a wind turbine (Task 2). During the late summer to fall of 2020 and 2021, Natural Power demonstrated that the use of the EchoSense smart curtailment system resulted in no significant difference in bat fatalities compared to blanket curtailment with cut-in speeds at 6.9 m/s (2020) and 5.0 m/s (2021) while resulting in a significant difference in decreased lost energy (Task 3). This translates to an average of 41% (2020) and 56% (2021) reduction in per turbine energy loss compared to blanket curtailment. The reduction in energy loss that would have been achieved by EchoSense curtailment compared to blanket curtailment, if applied across all 69 turbines, is roughly equivalent to having an additional turbine on site. These results are notable for finding a balance between the environmental impact of wind energy and the economic feasibility in energy production associated with mitigating that impact. https://www.naturalpower.com/us/expertise/service/engineering-operations/echosense

17 WIND ENERGY↗

A Smart System for the Contactless Measurement of Energy Expenditure

Energy Expenditure (EE) (kcal/day), a key element to guide obesity treatment, is measured from CO 2 production, VCO 2 (mL/min), and/or O 2 consumption, VO 2 (mL/min). Current technologies are limited due to the requirement of wearable facial accessories. A novel system, the Smart Pad, which measures EE via VCO 2 from a room’s ambient CO 2 concentration transients was evaluated. Resting EE (REE) and exercise VCO 2 measurements were recorded using Smart Pad and a reference instrument to study measurement duration’s influence on accuracy. The Smart Pad displayed 90% accuracy (±1 SD) for 14–19 min of REE measurement and for 4.8–7.0 min of exercise, using known room’s air exchange rate. Additionally, the Smart Pad was validated measuring subjects with a wide range of body mass indexes (BMI = 18.8 to 31.4 kg/m2), successfully validating the system accuracy across REE’s measures of ~1200 to ~3000 kcal/day. Furthermore, high correlation between subjects’ VCO 2 and λ for CO 2 accumulation was observed (p < 0.00001, R = 0.785) in a 14.0 m3 sized room. This finding led to development of a new model for REE measurement from ambient CO 2 without λ calibration using a reference instrument. The model correlated in nearly 100% agreement with reference instrument measures (y = 1.06x, R = 0.937) using an independent dataset (N = 56).

47 OTHER INSTRUMENTATION↗

Subscale maturation of advanced reactor technologies (SMART): A path forward for nuclear thermal propulsion fuel and reactor development

Nuclear Thermal Propulsion (NTP) systems are actively being developed for future crewed missions to Mars. NTP systems excel in missions where both high thrust and high specific impulse are required, but modern NTP systems currently do not have a Technology Readiness Level (TRL) high enough for use in crewed space exploration. TRLs are used to demonstrate the level of rigor with which a component/system has been tested/demonstrated for its intended use. While space systems technology in general must be qualified as a unit, nuclear technology must be first demonstrated to meet qualification level requirements both at the fuel (component) level and the reactor (subsystem) level. Here, in this paper, historic NTP development programs are surveyed to identify a testing and development strategy that can be effectively implemented to allow for NTP reactor development. Based on this strategy, required facilities to enable such activities are identified. Current domestic experimental capabilities to support NTP qualification are limited to separate effects testing of individual components. Separate effects testing is found extensively in historic NTP development efforts but is not sufficient for full fuel and reactor qualification. Combined effects testing allows for an accurate assessment of fuel performance but is not achievable for NTP conditions in existing facilities. Assessment of historic development programs suggests that an intermediate, subscale test facility is necessary to advance NTP TRLs. A solution to meet this need is proposed, namely the Subscale Maturation of Advanced Reactor Technologies (SMART) facility. SMART will mitigate risk to NTP development by enabling performance and reactor physics demonstrations of NTP subsystems. A SMART facility could be built by modifying existing nuclear test facilities, which may potentially enable schedule and cost savings. To pursue reactor qualification beyond the subscale, a new ground test facility will be necessary. This ground test facility should be developed concurrently with SMART to allow for the facility to be operational in time for expedited NTP engine demonstration.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A hardware-in-the-loop (HIL) testbed for cyber-physical energy systems in smart commercial buildings

In recent years, there has been a growing trend toward the development of smart buildings that rely on cyber-physical systems (CPS) to optimize occupant comfort, safety, and energy efficiency. To ensure the reliable and efficient operation of CPS with designed control strategies, it is important to evaluate their performance under various scenarios before deploying them in the real world. This is where a Hardware-in-the-loop (HIL) testbed designed for studying sensor and control-related studies in smart buildings can be highly valuable. With the growing threat of cyber-attacks and physical faults targeting smart buildings, it is essential to ensure the security of building operations. A HIL testbed can emulate cyber-attack and physical fault scenarios, allowing researchers to develop and test threat detection and mitigation algorithms. This enables researchers to identify potential issues and optimize the algorithms in a safe and controlled environment before they are deployed in real-world settings, reducing the risk of failures that can negatively impact occupant comfort, safety, and energy efficiency. Therefore, this paper developed a HIL testbed designed for cyber-physical energy systems (e.g. buildings automation system (BAS)) in smart commercial buildings. The HIL testbed is comprised of a real-time building and Heating, Ventilation, and Air-Conditioning (HVAC) emulator using Modelica-based dynamic models, a set of BAS controllers, and a BAS computer server. The data generation capability of the HIL testbed is demonstrated by tracking normal and faulty operating data in the BAS, as well as monitoring detailed network traffic in the local BAS network. Here, this study further demonstrates the HIL testbed’s capability by conducting case studies on real-time physical fault and cyber-attack experiments using a Department of Energy (DOE) prototype commercial building. It is anticipated that the fully functional HIL testbed will be utilized for a variety of sensor and control-related studies, including but not limited to testing, developing, validating of different HVAC control strategies, fault detection & diagnosis, energy monitoring and analysis, cyber security study, etc.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Three-Tier Incremental Approach for Development of Smart Corridor Digital Twins

Development of an arterial smart corridor digital twin requires the integration of real time data streams, data storage, and simulation model execution. This process may be complex, time consuming, and susceptible to errors. To aid in smart corridor digital twin development this paper seeks to provide a framework, best practices, and development guidance. As such, a three-tier incremental approach to smart corridor digital twin development is presented. The paper highlights practical issues in digital twin construction along with key data challenges based on experiences from the development of digital twins for two large Smart Corridor deployments, one in Chattanooga, Tennessee, and the other in Atlanta, Georgia. The presented three-tier incremental approach includes: 1) development of a prepopulated offline simulation, 2) development of a pseudo digital twin that is driven by archived data, and 3) integration of real time data streams to create the online digital twin model. The three-tiered approach facilitates conducting multiple trials and scenarios with increasing complexity, allowing for incremental error processing and updating of the digital twin.

Saroj, Abhilasha↗

Model Residuals as Shields: A Two-Level Formulation to Defend Smart Grids From Poisoning Attacks

The advancement of smart grids presents both vast opportunities and heightened cybersecurity risks. Data-driven defense mechanisms, though designed as a shield against these threats, can fall prey to poisoning attacks. We delve into regression settings, underscoring the imperative to fortify defenses against a spectrum of poison ratios, notably those above 0.5—an issue scarcely addressed in prior studies. Recognizing the susceptibilities of smart grids and their manipulable sensors, we exploit the very intent of poisoning attacks, compromising model accuracy, as our defense mechanism. Our proposed two-level optimization framework discerns between poisoned and authentic data based on model residuals, outperforming or matching existing methods in 72% to 77% of precision and 75% to 80% of recalls across various poisoning attacks, poison ratios, and datasets. Once the authentic data are identified, the trained model is adaptable for a variety of applications. Comprehensive evaluations on different smart grid datasets, pitted against myriad poisoning schemes, validate our methodology’s edge over existing methods. Here, we also shed light on the implications of model misspecification originating from temporal auto-correlation, a common feature in Internet of Things and smart grid data.

Adversarial machine learning (ML)↗

Toward a Smart Metaverse City: Immersive Realism and 3D Visualization of Digital Twin Cities

Metaverse and its related extended reality technologies can enable immersive, realistic, and participatory visualization of 3D data, and their use and the potential within a smart city can be effective for supporting urban research and urban operations management. This book chapter describes a vision for prototyping a “Smart Metaverse City” to combine the unique advantage of the Metaverse technology with the two-way connectivity of a digital twin city application. This synergy aims to create a virtual environment for immersive geovisualization to help researchers and the public understand the complex urban system through science-based and data-driven approaches. This book chapter selectively reviews past technological and paradigm advancements for collecting, analyzing, and visualizing 3D urban big data. Then we present a prototyping Geographic Information System (GIS) framework, together with some relevant data sources and open-source web technologies, to help researchers create a smart Metaverse city. We demonstrate our vision and discuss its application opportunities through a real-world example, a digital twin city developed at the Oak Ridge National Laboratory, to facilitate participatory, smart, and sustainable campus management.

Xu, Haowen↗

SMART SiC Power ICs: Scalable, Manufacturable, and Robust Technology for SiC Power Integrated Circuits (Final Technical Report)

This collaborative project was initiated with the goal of developing Scalable, Manufacturable, and Robust Technology for SiC Power Integrated Circuits (SMART SiC Power ICs). In pursuit of this objective, innovative designs and fabrication processes were implemented, enabling the development of large-scale (>1 cm²) SiC Complementary Metal-Oxide-Semiconductor (CMOS) integrated circuits and high-voltage (400–600 V) lateral power MOSFETs (HV-LDMOS) on 150 mm 4H-SiC substrates. The resulting SMART SiC Power ICs are tailored to support a wide range of applications requiring diverse voltage and power levels, including automotive systems, industrial equipment, electronic data processing, energy harvesting, and power conditioning. To achieve the proposed ‘SMART’ technology for SiC ICs, the team focused on 1) the Development of highly scalable CMOS (with high channel mobilities for n-type and p-type MOSFETs), LDMOS (~600V, 10A rated), and IC technologies, 2) Establishment of a manufacturable process baseline in a production-grade-, 150mm, SiC fabrication facility, and 3) Demonstration of SMART SiC ICs. The project initially comprised of fabricating 5 lots. In lot 1 monolithic integration using a single process was achieved. Here, we were able to successfully accomplish Integrated HV NMOSFET with LV CMOS on N-epi/N+ Substrate. The HV NMOS demonstrated a Breakdown Voltage (BV) more than 600V. Circuit demonstration of CMOS was also another achievement from this lot. In lot 2, priority was in place for isolation and integration. Here we addressed the isolation concerns and integrated the HV NMOS and LV CMOS using the N-epi/P-epi/N+ substrate. Similar to the lot 1, we were able to achieve a BV of 600 V for HV NMOS. Optimized gate oxide process with high channel mobilities, better gate oxide reliability, development of SPICE models, successful ohmic process development, novel wafer area saving design layouts, P+ isolation schemes with channeling implantations and high temperature operational circuits demonstrations are some of the key highlights from lot 1 and lot2. In lot 3, discrete device performances of HV NMOS with a BV ~700V and reliable LV CMOS performances were achieved. Also, novel architectural solutions were successfully implemented to suppress the electric field crowding at the gate oxide for reliable operations. In lot 4, half bridge power driver ICs with a conversion efficiency of (target 90% to 95%) in the 1-5MHz switching frequency range for output power between 25 W to 3 kW have been included in. However, due to the unfortunate events of sudden foundry shutdown (SiCamore Semi) the processing of lot 4 wafers came to a complete stop (January 2024). Arrangements have recently been made to shift the fabrication to another foundry, General Electric Aerospace. The fabrication process now on course (as of December 2024). Characterizations are delayed due to this unfortunate circumstance. The proposed trench architectural-based devices and ICs (lot 5) underwent modifications from the original project proposal. This change was necessitated by limitations in the availability of trench-based processes at commercial production-grade fabrication facilities in the US. Apart from above achievements, a Process Development Kit (PDK) was successfully developed for planar type SiC CMOS/LDMOS.

42 ENGINEERING↗

Design and Experimental Demonstration of an Additive Manufactured Smart Oxy-Methane Burner for High Pressure and Supercritical Combustion

Pressurized oxy combustion-based systems can improve efficiency by recovering latent heat of the steam in the Flue Gas and achieving 90% CO2 capture. In addition, the novel Directly Heated Supercritical Carbon Dioxide (DH-SCO2) power cycles can achieve high thermal efficiencies and provide nearly full carbon capture. Additionally, due to the reduction of flue gas at higher pressure, smaller system size and capital cost reductions are also possible. Recent thermodynamic analysis of the DH-SCO2 cycle performed by the UTEP research team shows that combustion conditions in the vicinity of 300 bar pressure and 1000-1400 K temperature allow for relatively high system efficiencies while operating within the limit of available combustor materials. However, the realization of a directly heated supercritical power cycle requires combustion systems to operate in supercritical conditions and at temperature far below the blowout limit of conventional flames (above 1500 K). The thermodynamic properties along with the combustion properties and kinetics are unexplored at such conditions. Additionally, the interaction of the supercritical environment with energy components is also unknown. High-pressure combustion tests are performed using a smart burner at some intermediate pressure ranges (<20 bar) to help minimize these knowledge gaps. The knowledge obtained from the high-pressure test will assist in understanding the combustion chamber pressurization mechanism, ignition and flame behavior at the elevated pressure. The obtained data will act as a systematic first step in testing at higher pressures of 100 and 300 bar pressures.The primary purpose of this Dissertation is to demonstrate the operability of a low NOx smart burner for oxy-methane combustion at high pressure (< 20 bar) and scalable up to supercritical conditions. A shear co-axial smart burner is designed with a real-time temperature monitoring capability to understand the burner face interaction at high-pressure conditions. In addition, the burner has four independent injection ports to allow the independent injection of fuel and dilution gases in the combustor. The maximum operating capability of the burner is 575 kWth. The burner was fabricated using a Laser Powder Bed Fusion process with Nickel Alloy 718. A powder removal technology was invented comprising ultrasonic vibration, liquid nitrogen exposure and media blasting to remove powders from internal channels of the burner. The burner operability tests are performed in the high-pressure combustor and the swirl combustor. The high-pressure combustor was used to investigate the burner operability and thermal soak back at different pressurized conditions. The experimental tests in high-pressure combustor up to 275 kWth input resulted in 16.5 bar chamber pressure and 198°C thermal soaks back to the burner. The burner was capable of providing the required thermal input within a 3% deviation range. In addition, soot formation occurred at high-pressure tests. The swirl combustor was used to observe the flame stability of the burner. Flame lift-off was observed for jet velocities above 450 m/s. Additionally, lift-off decreased for low co-flow velocities. CO2 dilution experiments showed increased flame instabilities for all conditions above 50% dilution ratios. At lower thermal inputs, partial flame blow-offs occurred for dilution ratios above 50%. All conditions significantly reduced the flame temperature and increased the flame lift-off height. Finally, a 2nd generation AM smart burner was designed using the knowledge from the 1st generation burner experiments. The 2nd generation burner incorporated two sets of swirlers with 0.9 swirl no. A cooling system was also designed for long-duration tests at higher pressures. The thermal input and division of the burner's power are kept the same as the 1st generation burner. The burner is to be fabricated using nickel-alloy 718 for high-pressure handling capability. The design can sustain at high-pressure conditions up to 100 bar.

Islam, Md Nawshad Arslan↗

A multi-agent approach to distribution system fault section estimation in smart grid environment

We report that Multi-Agent Systems (MAS) are seen from different areas as one of the paramount trends for the next generation of power systems. Numerous published studies about MAS discuss its utilization in power distribution networks but none focuses on the prior step to restoration and self-healing that is fault section estimation. This paper aims to show how MAS can improve the utilities’ reliability indexes and consumer satisfaction by overcoming the multiple fault section estimation problem. In order to do this, the authors considered using MAS as a means of communication between smart meters. The purpose of smart meters usage is to employ devices that are already present in smart grids, mainly because of their reading and saving data capacity. The proposed method was tested on a radial feeder generated by the authors. The network was built on HYPERSIM, a software platform of OPAL-RT Technologies. The simulation results show that this MAS provides speed, efficiency, and automation for the process of fault section estimation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Smart Meter Pinging and Reading Through AMI Two-Way Communication Networks to Monitor Grid Edge Devices and DERs

Today’s power distribution system is changing to a power-electronics-enabled distribution system, especially with the increasing penetration of distributed energy resources (DERs). To monitor and manage those electronic devices and DERs at the grid edge, the advanced metering infrastructure (AMI) with two-way communications presents great potential. At present, extensive research explores the upstream communication from smart meters to electric utilities (e.g., meter reading) but few examine the downstream communication from the utilities to smart meters (e.g., meter pinging). This article discusses the AMI two-way communication and its recent industrial practice in the U.S., especially for applying the smart meter pinging functionality to monitor grid-edge devices and DERs. This paper then develops the two-way communication model and the network calculus method to quantify the impact of the two-way communication on the AMI network. In the end, the proposed method is validated with ns-3 simulation using the modified 13-node test feeder and real-world feeder systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development and Validation of Smart Building Technology Modules for Academic and Professional Education

Slipstream leads a team developing a semester-long smart building curriculum for college students and adapting the contents into 16 training videos for building professionals and the public. The topics cover smart building technologies related content including industry trends and benefits, building systems, sensors and IoT devices, advanced building monitoring and controls, smart building control platform, methods, and applications.

99 GENERAL AND MISCELLANEOUS↗

Ensemble voting-based fault classification and location identification for a distribution system with microgrids using smart meter measurements

This study presents an ensemble learning approach for fault classification and location identification in a smart distribution network containing photovoltaics (PV)-based microgrid. Lack of available data points and the unbalanced nature of the distribution system make fault handling a challenging task for utilities. The proposed method uses event-driven voltage data from smart meters to classify and locate faults. The ensemble voting classifier is composed of three base learners; random forest, k-nearest neighbours, and artificial neural network. The fault location (FL) task has been formulated as a classification problem where the fault type is classified in the first step and based on the fault type, the faulty bus is identified. The method is tested on IEEE-123 bus system modified with added PV-based microgrid along with dynamic loading conditions and varying fault resistances from 0 to 20 Ω for both unbalanced and balanced fault types. A further sensitivity analysis has been done to test the robustness of the proposed method under various noise levels and data loss errors in the smart meter measurements. The ensemble method shows improved performance and robustness compared to some previously proposed FL methods. Finally, the proposed method has been experimentally validated on a real-time simulation-based testbed using a state-of-the-art digital real-time simulator, industry standard DNP3 communication protocol and a cpu-based control centre running the FL algorithm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Moving Target Defense Routing for SDN-enabled Smart Grid

The increasing attack surface area in the smart grid communication networks is making the grid more susceptible to cyber attacks that can lead to instability of the grid and even blackouts. While there are multiple types of cyber attacks that can impact the grid, Denial of Service (DoS) attacks are relatively easier to inject as they require lesser knowledge about the system as compared to data integrity attacks. Various research works showcase methods to prevent or mitigate the impacts of DoS attacks in the smart grid but the research still lacks in demonstrating the feasibility and efficacy of the solutions in a real-world environment. In this paper, we propose a Moving Target Defense (MTD)-enabled Software Defined Network (SDN) for the Smart Grid communication implemented on a Hardwarein- the-Loop (HIL) Testbed. We showcase the implementation of the proposed architecture of MTD-enabled SDN using Mininet 2.3.0 which enables communication between the physical grid and the control center. The results show the advantages of using MTD based on SDN for the wide-area network (WAN) with much lower packet drop percentages in the case of MTD-based routing in the SDN WAN. Index Terms—SDN,

97 MATHEMATICS AND COMPUTING↗

On the Use of Smart Meter Data to Estimate the Voltage Magnitude on the Primary Side of Distribution Service Transformers

This paper develops a novel method to estimate the voltage magnitude on the primary side of distribution service transformers. The proposed method relies exclusively on smart meters, and therefore it is fully data-driven. This is an important feature because electric utilities have detailed models of only the primary network - that is, the network between the distribution substation and the primary side of service transformers that are installed closer to end-customer sites. The network that connects the secondary side of service transformers to end-customer sites, referred to as the secondary network, is simply represented by a lumped load. For each secondary network, the proposed method uses data acquired from only 2 smart meters: the closest and the farthest-in the sense of electrical distance - from the service transformer. As a reference to this feature, the proposed method is named SM2Vp. To our knowledge, this is the first time a method is shown to provide actionable information for realtime operation and control of power distribution grids using only two smart meters per secondary network. This is important because utilities have experienced barriers in managing and using large data sets for real-time operation and control. SM2Vp is primarily intended to provide pseudo-measurements for distribution system state estimation, but it can also be used directly for voltage control schemes. The performance of SM2Vp is demonstrated by numerical simulations carried out on three secondary network synthetic models and by using field data provided by a utility partner serving customers in southwestern California. A maximum relative error of approximately 3.9% or less is observed for the primary voltage magnitude estimates in all numerical experiments.

distribution service transformer↗