Narrowband signal detection in the SETI field test

Various methods for detecting narrow-band signals are evaluated. The characteristics of synchronized and unsynchronized pulses are examined. Synchronous, square law, regular pulse, and the general form detections are discussed. The CW, single pulse, synchronous, and four pulse detections are analyzed in terms of false alarm rate and threshold relative to average noise power. Techniques for saving memory and retaining sensitivity are described. Consideration is given to nondrifting CW detection, asynchronous pulse detection, interpolative and extrapolative pulse detectors, and finite and infinite pulses.

Cullers, D. Kent↗

Sensitive Infrared Signal Detection by Upconversion Technique

We demonstrated upconversion assisted detection of a 2.05-micron signal by sum frequency generation to generate a 700-nm light using a bulk periodically poled lithium niobate crystal. The achieved 94% intrinsic upconversion efficiency and 22.58% overall detection efficiency at a pW level of 2.05 micron pave the path to detect extremely weak infrared (IR) signals for remote sensing applications.

Wong, Teh-Hwa↗

Signal Detection Techniques for Diagnostic Monitoring of Space Shuttle Main Engine Turbomachinery

An investigation to develop, implement, and evaluate signal analysis techniques for the detection and classification of incipient mechanical failures in turbomachinery is reviewed. A brief description of the Space Shuttle Main Engine (SSME) test/measurement program is presented. Signal analysis techniques available to describe dynamic measurement characteristics are reviewed. Time domain and spectral methods are described, and statistical classification in terms of moments is discussed. Several of these waveform analysis techniques have been implemented on a computer and applied to dynamc signals. A laboratory evaluation of the methods with respect to signal detection capability is described. A unique coherence function (the hyper-coherence) was developed through the course of this investigation, which appears promising as a diagnostic tool. This technique and several other non-linear methods of signal analysis are presented and illustrated by application. Software for application of these techniques has been installed on the signal processing system at the NASA/MSFC Systems Dynamics Laboratory.

Coffin, Thomas↗

VLSI processors for signal detection in SETI

The objective of the Search for Extraterrestrial Intelligence (SETI) is to locate an artificially created signal coming from a distant star. This is done in two steps: (1) spectral analysis of an incoming radio frequency band, and (2) pattern detection for narrow-band signals. Both steps are computationally expensive and require the development of specially designed computer architectures. To reduce the size and cost of the SETI signal detection machine, two custom VLSI chips are under development. The first chip, the SETI DSP Engine, is used in the spectrum analyzer and is specially designed to compute Discrete Fourier Transforms (DFTs). It is a high-speed arithmetic processor that has two adders, one multiplier-accumulator, and three four-port memories. The second chip is a new type of Content-Addressable Memory. It is the heart of an associative processor that is used for pattern detection. Both chips incorporate many innovative circuits and architectural features.

NASA Program Exobiology↗

Vestibular receptor cells and signal detection: bioaccelerometers and the hexagonal sampling of two-dimensional signals

The inner ear contains sensory organs which signal changes in head movement. The vestibular sacs, in particular, are sensitive to linear accelerations. Electron microscopic images have revealed the structure of tiny sensory hair bundles, whose mechanical deformation results in the initiation of neuronal activity and the transmission of electrical signals to the brain. The structure of the hair bundles is shown in this paper to be that of the most efficient two-dimensional phased-array signal processors.

NASA Program Space Physiology and Countermeasures↗

Infrared Signal Detection by Upconversion Technique

We demonstrated up-conversion assisted detection of a 2.05-micron signal by using a bulk periodically poled Lithium niobate crystal. The 94% intrinsic up-conversion efficiency and 22.58% overall detection efficiency at pW level of 2.05-micron was achieved.

Wong, Teh-Hwa↗

Application of LSI to signal detection: The deltic DFPCC

The development of the DELTIC DFPCC serial mode signal processor is discussed. The processor is designed to detect in the presence of background noise a signal coded into the zero crossings of the waveform. The unique features of the DELTIC DFPCC include versatility in handling a variety of signals and relative simplicity in implementation. A theoretical performance model is presented which predicts the expected value of the output signal as a function of the input signal to noise ratio. Experimental results obtained with the prototype system, which was breadboarded with LSI, MSI and SSI components, are given. The device was compared with other LSI schemes for signal processing and it was concluded that the DELTIC DFPCC is simpler and in some cases more versatile than other systems. With established LSI technology, low frequency systems applicable to sonar and similar problems are feasible.

Gassaway, J. D.↗

The Sensitive Infrared Signal Detection by Sum Frequency Generation

An up-conversion device that converts 2.05-micron light to 700 nm signal by sum frequency generation using a periodically poled lithium niobate crystal is demonstrated. The achieved 92% up-conversion efficiency paves the path to detect extremely weak 2.05-micron signal with well established silicon avalanche photodiode detector for sensitive lidar applications.

Wong, Teh-Hwa↗

Development of a Photon Counting System for Differential Lidar Signal Detection

Photon counting has been chosen as a means to extend the detection range of current airborne DIAL ozone measurements. Lidar backscattered return signals from the on and off-line lasers experience a significant exponential decay. To extract further data from the decaying ozone return signals, photon counting will be used to measure the low light levels, thus extending the detection range. In this application, photon counting will extend signal measurement where the analog return signal is too weak. The current analog measurement range is limited to approximately 25 kilometers from an aircraft flying at 12 kilometers. Photon counting will be able to exceed the current measurement range so as to follow the mid-latitude model of ozone density as a function of height. This report describes the development of a photon counting system. The initial development phase begins with detailed evaluation of individual photomultiplier tubes. The PMT qualities investigated are noise count rates, single electron response peaks, voltage versus gain values, saturation effects, and output signal linearity. These evaluations are followed by analysis of two distinctive tube base gating schemes. The next phase is to construct and operate a photon counting system in a laboratory environment. The laboratory counting simulations are used to determine optimum discriminator setpoints and to continue further evaluations of PMT properties. The final step in the photon counting system evaluation process is the compiling of photon counting measurements on the existing ozone DIAL laser system.

Elsayed-Ali, Hani↗

Three-Gorge Reservoir: A 'Controlled Experiment' for Calibration/Validation of Time-Variable Gravity Signals Detected from Space

With the advances of measurements, modern space geodesy has become a new type of remote sensing for the Earth dynamics, especially for mass transports in the geophysical fluids on large spatial scales. A case in point is the space gravity mission GRACE (Gravity Recovery And Climate Experiment) which has been in orbit collecting gravity data since early 2002. The data promise to be able to detect changes of water mass equivalent to sub-cm thickness on spatial scale of several hundred km every month or so. China s Three-Gorge Reservoir has already started the process of water impoundment in phases. By 2009,40 km3 of water will be stored behind one of the world s highest dams and spanning a section of middle Yangtze River about 600 km in length. For the GRACE observations, the Three-Gorge Reservoir would represent a geophysical controlled experiment , one that offers a unique opportunity to do detailed geophysical studies. -- Assuming a complete documentation of the water level and history of the water impoundment process and aided with a continual monitoring of the lithospheric loading response (such as in area gravity and deformation), one has at hand basically a classical forwardinverse modeling problem of surface loading, where the input and certain output are known. The invisible portion of the impounded water, i.e. underground storage, poses either added values as an observable or a complication as an unknown to be modeled. Wang (2000) has studied the possible loading effects on a local scale; we here aim for larger spatial scales upwards from several hundred km, with emphasis on the time-variable gravity signals that can be detected by GRACE and follow-on missions. Results using the Green s function approach on the PREM elastic Earth model indicate the geoid height variations reaching several millimeters on wavelengths of about a thousand kilometers. The corresponding vertical deformations have amplitude of a few centimeters. In terms of long-wavelength spherical harmonics, the induced geoid height variations are very close to the accuracy of GRACE- recoverable gravity field, while the low-degree (2 to 5) harmonics should be detectable. With a large regional time-variable gravity signal, the Three-Gorge experiment can serve as a useful calibration/verification for GRACE (including the elastic loading effects), and future gravity missions (especially for visco-elastic yielding as well as underground water variations).

Chao, Benjamin F.↗

A signal detection strategy for the SETI All Sky Survey

A source detection strategy for the SETI All Sky Survey is described. The method is designed to detect continuous wave (or very narrowband) sources transitting an antenna beam. The short-time spectra of the received signal are accumulated, and candidate extraterrestrial sources are recognized by the recognized by the presence of narrowband power exceeding a threshold function. The threshold function is derived using a Neyman-pearson hypothesis test.

Lawton, W.↗

Signal detection in l/f noise of SQUID magnetometers

It is shown that the variance on the SQUID power spectrum in the l/f low frequency region is well behaved, i.e., any small frequency band may be treated as white noise in standard power spectrum estimation theory. Specifically a calibration signal is examined at 0.017 Hz with an equivalent energy referred to the SQUID input coil of 1 times 10 to the -30th J and a digitally recorded and analyzed record of 140 hr duration obtained an optimum S/N better than 400. The results are in good agreement with theory. In addition no deviation from the l/f dependence of the noise energy spectrum is seen down to frequencies below 10 to the -5th Hz. A commercially available SQUID and electronics system were used.

Cabrera, B.↗

Vertex potentials evoked during auditory signal detection - Relation to decision criteria

Vertex potentials were recorded from eight subjects performing in an auditory threshold detection task with rating scale responses. The amplitudes and latencies of both the N1 and the late positive (P3) components were found to vary systematically with the criterion level of the decision. These changes in the waveshape of the N1 component were comparable to those produced by varying the signal intensity in a passive condition, but the late positive component in the active task was not similarly related to the passively evoked P2 component. It was suggested that the N1 and P3 components represent distinctive aspects of the decision process, with N1 signifying the quantity of signal information received and P3 reflecting the certainty of the decision based upon that information.

Squires, K. C.↗

Test of the magneto optical filter during the comet P/Shoemaker-Levy 9 impacts on Jupiter. A Doppler signal detected?

The observations made in July 1994 on the impact of fragment A of the comet P/Shoemaker-Levy 9 with Jupiter are described. The instrumentation used was a magneto-optical filter, acting as a two-channel filter. The data showed a double-peak transient which occurred after the impact, and whose general properties indicated a true jovian origin. The peaks appear in absorption. A numerical simulation can explain the main characteristics of the observed signal where the two peaks have the same polarity and appear only in the channel at shorter wavelengths. The simulation carried out appeared to indicate that the observed signal could be produced by the combination of shock waves and the expanding material with a velocity of 13 +/- 8 km/s. This implies that two separate impacts may have been observed. The developed simulation can be extended to predict long term effects.