Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SHUNT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A 100 GHz Josephson mixer using resistively-shunted Nb tunnel junctions

The authors describe preliminary mixer results using resistively shunted Nb/AlO(x)/Nb tunnel junctions in a 100-GHz waveguide mixer mount. The mixer utilizes robust, lithographically defined devices which have nonhysteretic I-V curves. A receiver temperature of 390 K (DSB) has been obtained with a conversion loss of -6.5 dB. The receiver's behavior agrees qualitatively with the behavior predicted by the resistively shunted junction model. Substantial improvements in performance are expected with the use of better-optimized shunted junctions, and numerical simulations suggest that, if devices with higher ICRN (critical current-normal state resistance) products can be obtained, Josephson effect mixers could be competitive with SIS mixers at high frequencies.

Schoelkopf, R. J.↗

Optimal Topology and Experimental Evaluation of Piezoelectric Materials for Actively Shunted General Electric Polymer Matrix Fiber Composite Blades

NASA Glenn Research Center, in collaboration with GE Aviation, has begun the development of a smart adaptive structure system with piezoelectric (PE) transducers to improve composite fan blade damping at resonances. Traditional resonant damping approaches may not be realistic for rotating frame applications such as engine blades. The limited space in which the blades reside in the engine makes it impossible to accommodate the circuit size required to implement passive resonant damping. Thus, a novel digital shunt scheme has been developed to replace the conventional electric passive shunt circuits. The digital shunt dissipates strain energy through the load resistor on a power amplifier. General Electric (GE) designed and fabricated a variety of polymer matrix fiber composite (PMFC) test specimens. Investigating the optimal topology of PE sensors and actuators for each test specimen has revealed the best PE transducer location for each target mode. Also a variety of flexible patches, which can conform to the blade surface, have been tested to identify the best performing PE patch. The active damping control achieved significant performance at target modes. This work has been highlighted by successful spin testing up to 5000 rpm of subscale GEnx composite blades in Glenn s Dynamic Spin Rig.

Choi, Benjamin B.↗

The results of systems tests of the 500 kV busbar controllable shunting reactor in the Tavricheskaya substation

The results of systems tests of the 500 kV busbar magnetization-controllable shunting reactor (CSR), set up in the Tavricheskaya substation, including measurements of the quality of the electric power, the harmonic composition of the network currents of the reactor for different values of the reactive power consumed, the determination of the regulating characteristics of the reactor, the speed of response of the shunting reactor in the current and voltage stabilization modes, and also the operation of the reactor under dynamic conditions for different perturbations, are presented. The results obtained are analyzed.

42 ENGINEERING↗

Increasing the reliability of the shutdown of 500 - 750-kV overhead lines equipped with shunt reactors in an unsuccessful three-phase automatic repeated closure cycle

The reasons for circuit-breaker failures during repeated disconnection of 500 - 750 kV overhead lines with shunt reactors in a cycle of unsuccessful three-phase automatic reconnection (TARC) are analyzed. Recommendations are made for increasing the operating reliability of power transmission lines with shunt reactors when there is unsuccessful reconnection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Two-Step Absorber Deposition Approach To Overcome Shunt Losses in Thin-Film Solar Cells: Using Tin Sulfide as a Proof-of-Concept Material System

As novel absorber materials are developed and screened for their photovoltaic (PV) properties, the challenge remains to reproducibly test promising candidates for high-performing PV devices. Many early-stage devices are prone to device shunting due to pinholes in the absorber layer, producing “false-negative” results. We demonstrate a device engineering solution toward a robust device architecture, using a two-step absorber deposition approach. We use tin sulfide (SnS) as a test absorber material. The SnS bulk is processed at high temperature (400 °C) to stimulate grain growth, followed by a much thinner, low-temperature (200 °C) absorber deposition. At a lower process temperature, the thin absorber overlayer contains significantly smaller, densely packed grains, which are likely to provide a continuous coating and fill pinholes in the underlying absorber bulk. We compare this two-step approach to the more standard approach of using a semi-insulating buffer layer directly on top of the annealed absorber bulk, and we demonstrate a more than 3.5× superior shunt resistance R sh with smaller standard error σ Rsh . Electron-beam-induced current (EBIC) measurements indicate a lower density of pinholes in the SnS absorber bulk when using the two-step absorber deposition approach. We correlate those findings to improvements in the device performance and device performance reproducibility.

14 SOLAR ENERGY↗

Use of the Viatorr Expanded Polytetrafluoroethylene-Covered Stent-Graft for Transjugular Intrahepatic Portosystemic Shunt Creation in Children: Initial Clinical Experience

Four children, three boys and one girl, with a median age of 9 years 8 months, underwent transjugular intrahepatic portosystemic shunt creation with an expanded polytetrafluoroethylene (e-PTFE)-covered nitinol stent. The stent-graft was successfully placed in all four patients without any complication. Clinical and biochemical improvement was noted in all four patients during follow-up. Radiological follow-up with use of duplex ultrasound showed a recurrent stenosis of the shunt 180 days after stent-graft implantation in one patient. This was treated with placement of an additional stent-graft, re-expanding completely the recurrent stenosis. In the other three patients, the stent-graft remained fully patent until the end of the study or until orthotopic liver transplantation. These preliminary results suggest that use of the Viatorr ePTFE-covered stent-graft in children is safe and feasible, with potentially the same high patency rate and improved clinical outcome as reported in adult patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Short-Term Effects of Transjugular Intrahepatic Shunt on Cardiac Function Assessed by Cardiac MRI: Preliminary Results

The purpose of this study was to assess short-term effects of transjugular intrahepatic shunt (TIPS) on cardiac function with cardiac magnetic resonance imaging (MRI) in patients with liver cirrhosis. Eleven patients (six males and five females) with intractable esophageal varices or refractory ascites were imaged with MRI at 1.5 T prior to, within 24 h after, and 4-6 months after TIPS creation (n = 5). Invasive pressures were registered during TIPS creation. MRI consisted of a stack of contiguous slices as well as phase contrast images at all four valve planes and perpendicular to the portal vein. Imaging data were analyzed through time-volume curves and first derivatives. The portoatrial pressure gradient decreased from 19.8 {+-} 2.3 to 6.6 {+-} 2.3, accompanied by a nearly two fold increase in central pressures and pulmonary capillary wedge pressure immediately after TIPS creation. Left and right end diastolic volumes and stroke volumes increased by 11, 13, and 24%, respectively (p < 0.001), but dropped back to baseline at follow-up. End systolic volumes remained unchanged. E/A ratios remained within normal range. During follow-up the left ventricular mass was larger than baseline values in all patients, with an average increase of 7.9 g (p < 0.001). In conclusion, the increased volume load shunted to the heart after TIPS creation transiently exceeded the preload reserve of the right and left ventricle, leading to significantly increased pulmonary wedge pressures and persistent enlargement of the left and right atria. Normalization of cardiac dimensions was observed after months together with mild left ventricular hypertrophy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pancreaticoportal Fistula and Disseminated Fat Necrosis After Revision of a Transjugular Intrahepatic Portosystemic Shunt

A 59-year old man with alcohol related cirrhosis and portal hypertension was referred for transjugular intrahepatic portosystemic shunt (TIPS) to treat his refractory ascites. Ten years later, two sequential TIPS revisions were performed for shunt stenosis and recurrent ascites. After these revisions, he returned with increased serum pancreatic enzyme levels and disseminated superficial fat necrosis; an iatrogenic pancreaticoportal vein fistula caused by disruption of the pancreatic duct was suspected. The bare area of the TIPS was subsequently lined with a covered stent-graft, and serum enzyme levels returned to baseline. In the interval follow-up period, the patient has clinically improved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Mesocaval Shunt Creation in a Patient with Chronic Portal and Superior Mesenteric Vein Thrombosis

The creation of a transjugular intrahepatic portosystemic shunt (TIPS) is a critical procedure for the treatment of recurrent variceal bleeding and refractory ascites in the setting of portal hypertension. Chronic portal vein thrombosis remains a relative contraindication to conventional TIPS and options are limited in this scenario. Presented is a novel technique for management of refractory ascites in a patient with hepatitis C cirrhosis and chronic portal and superior mesenteric vein thrombosis secondary to schistosomiasis and lupus anticoagulant utilizing fluoroscopically guided percutaneous mesocaval shunt creation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Anatomical, Procedural, and Operator Skill Factors on the Success and Duration of Fluoroscopy-Guided Transjugular Intrahepatic Portosystemic Shunt

PurposeTo assess the impact of anatomical, procedural, and operator skill factors on the success and duration of fluoroscopy-guided transjugular intrahepatic portoystemic shunt following standard operating procedure (SOP).Material and MethodsDuring a 32-month period, 102 patients underwent transjugular intrahepatic portosystemic shunt creation (TIPS) by two interventional radiologists (IR) following our institutional SOP based on fluoroscopy guidance. Both demographic and procedural data were assessed. The duration of the intervention (D{sub Int}) and of the portal vein puncture (D{sub Punct}) was analyzed depending on the skill level of the IR as well as the anatomic or procedural factors.ResultsIn 99 of the 102 patients, successful TIPS without peri-procedural complications was performed. The mean D{sub Int} (IR1: 77 min; IR2: 51 min, P < 0.005) and the mean D{sub Punct} (IR1: 19 min; IR2: 13 min, P < 0.005) were significantly higher in TIPS performed by IR1 (with 2 years of clinical experience performing TIPS, n = 38) than by IR2 (>10 years of clinical experience performing TIPS, n = 61), (P < 0.005 both, Mann–Whitney U test). D{sub Int} showed a higher correlation with D{sub Punct} for IR2 (R{sup 2} = 0.63) than for IR1 (R{sup 2} = 0.13). There was no significant difference in the D{sub Punct} for both IRs with regard to the success of the wedged portography (P = 0.90), diameter of the portal vein (P = 0.60), central right portal vein length (P = 0.49), or liver function (MELD-Score before the TIPS procedure; P = 0.14).ConclusionTIPS following SOP is safe, fast, and reliable. The only significant factor for shorter D{sub Punct} and D{sub Int} was the clinical experience of the IR. Anatomic variability, successful portography, or liver function did not alter the duration or technical success of TIPS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Efficacy of Transjugular Intrahepatic Portosystemic Shunt Created with Expanded Polytetrafluoroethylene-Covered Stent-Grafts: 8-mm Versus 10-mm

Purpose: Conflicting data exist regarding the appropriate shunt diameter for transjugular intrahepatic portosystemic shunt (TIPS) creation in cirrhotic patients. This study was designed to compare the clinical efficacy of TIPS using stent-grafts with 8- and 10-mm diameters. Methods: In this retrospective study, cirrhotic patients who underwent TIPS technical successfully for the prevention of variceal rebleeding from December 2011 to June 2015 were included. Thirty-four patients with 8-mm TIPS and 380 patients with 10-mm TIPS were identified. Propensity score matching method produced 32 patients in each group for comparison. Results: Baseline characteristics between two groups were comparable. There was no significant difference in variceal rebleeding rate between the two groups. The cumulative incidence of variceal rebleeding after 1 and 3 years was 6.4% and 35.5% in the 8-mm group, respectively, and 14.2% and 24.9% in the 10-mm group, respectively (P = 0.663). 8-mm TIPS conferred a significant decrease in hepatic encephalopathy (HE) rate compared with the 10-mm TIPS (16.1 vs. 32.6% at 1 year, 27.8 vs. 53.2% at 3 years, P = 0.034). The cumulative survival rates were similar between the two groups: 93.3% and 79.6% at 1 and 3 years, respectively, in the 8-mm TIPS group vs. 87.3% and 72.1% at 1 and 3 years, respectively, in the 10-mm TIPS group (P = 0.451). Conclusion: The placement of 8-mm TIPS was sufficient to decompress the portal hypertension and prevent variceal rebleeding. The use of the 8-mm stent-graft can decrease HE rates compared with 10-mm stent-graft, although no survival benefit was observed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adjuvant Transjugular Variceal Occlusion at Creation of a Transjugular Intrahepatic Portosystemic Shunt (TIPS): Efficacy and Risks of Bucrylate Embolization

Adjuvant embolization of varices may reduce rebleeding in patients with a transjugular intrahepatic portosystemic shunt (TIPS). The aim of this study was to investigate the efficacy and the risks of adjuvant variceal embolization at TIPS implantation using bucrylate. Patients and Methods: The retrospective study evaluated 104 of 237 cirrhotic patients with TIPS for variceal bleeding who received adjuvant bucrylate embolization. For TIPS creation, bare stents were used in 35 patients (33.7%) and covered stents in 69 patients (66.3%) patients. Isolated gastric varices were seen in 10 patients (9.6%). Results: Six patients (5.8%) rebled during a median follow-up time of 26 months (1–57 months). Rebleeding occurred in 14% (5/35) of patients with a bare stent but only in 1.4% (1/69) of patients with a covered stent. The 1- and 2-year rebleeding rates of all patients were 0.9 and 2.9% and of patients receiving a bare stent were 2.9 and 8.6%, respectively. Bucrylate migration was seen in 13 patients (12.5%). In 9 of these patients (8.7%), asymptomatic lung embolization occurred. This was rare in patients with esophageal varices (3.1%) but frequent (60%) in patients with isolated gastric varices and a spontaneous splenorenal shunt. Conclusions: Our results suggest that adjuvant embolization using bucrylate is effective and delays variceal rebleeding. The general use of covered stents, however, alleviates the utility of adjuvant bucrylate embolization which may be restricted to patients with a high risk of rebleeding indicated by large varices, active, acute or recent variceal bleeding and advanced cirrhosis. Bucrylate should not be used in isolated gastric varices because it bears a high risk of migration into the lungs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intracellular shunting of O{sub 2}{sup −} contributes to charge compensation and preservation of neutrophil respiratory burst in the absence of voltage-gated proton channel activity

Proton efflux via voltage-gated proton channels (Hv1) is considered to mediate the charge compensation necessary to preserve NADPH oxidase activity during the respiratory burst. Using the Hv1 inhibitor Zn{sup 2+}, we found that the PMA-induced respiratory burst of human neutrophils is inhibited when assessed as extracellular production of O{sub 2}{sup −} and H{sub 2}O{sub 2}, in accordance with literature studies, but, surprisingly, unaffected when measured as oxygen consumption or total (extracellular plus intracellular) H{sub 2}O{sub 2} production. Furthermore, we show that inhibiting Hv1 with Zn{sup 2+} results in an increased production of intracellular ROS. Similar results, i.e. decreased extracellular and increased intracellular ROS production, were obtained using a human granulocyte-like cell line with severely impaired Hv1 expression. Acidic extracellular pH, which dampens proton efflux, also augmented intracellular production of H{sub 2}O{sub 2}. Zinc caused an increase in the rate but not in the extent of depolarization and cytosolic acidification indicating that mechanisms other than proton efflux take part in charge compensation. Our results suggest a hitherto unpredicted mechanism of charge compensation whereby, in the absence of proton efflux, part of O{sub 2}{sup −} generated within gp91{sup phox} in the plasma membrane is shunted intracellularly down electrochemical gradient to dampen excessive depolarization. This would preserve NADPH oxidase activity under conditions such as the inflammatory exudate in which the acidic pH hinders charge compensation by proton efflux. Highlights: • Neutrophils’ respiratory burst is not inhibited by the H{sup +} channel inhibitor Zn{sup 2+}. • Intracellular production of O{sub 2}{sup −} and H{sub 2}O{sub 2} is increased in the presence of Zn{sup 2+}. • Intracellular H{sub 2}O{sub 2} production is increased in H{sup +} channels knock-down cells. • Zn{sup 2+} increases the rate but not the extent of depolarization and pH{sub i} decrease. • Intracellular shunting of O{sub 2}{sup −} contributes to charge compensation in neutrophils.

60 APPLIED LIFE SCIENCES↗

Crystallographic and Catalytic Studies of the Peroxide-Shunt Reaction in a Diiron Hydroxylase

A diiron hydroxylase reaction typically begins by combination of O{sub 2} with a diferrous center to form reactive intermediates capable of hydrocarbon hydroxylation. In this natural cycle, reducing equivalents are provided by specific interactions with electron transfer proteins. The biological process can be bypassed by combining H{sub 2}O{sub 2} with a diferric center, i.e., peroxide-shunt catalysis. Here we show that toluene 4-monooxygenase has a peroxide-shunt reaction that is {approx}600-fold slower than catalysis driven by biological electron transfer. However, the toluene 4-monooxygenase hydroxylase-effector protein complex was stable in the presence of 300 mM H{sub 2}O{sub 2}, suggesting overall benign effects of the exogenous oxidant on active site structure and function. The X-ray structure of the toluene 4-monooxygenase hydroxylase-effector protein complex determined from crystals soaked in H{sub 2}O{sub 2} revealed a bound diatomic molecule, assigned to a cis-{mu}-1,2-peroxo bridge. This peroxo species resides in an active site position adjacent to the hydrogen-bonding substructure established by effector protein binding and faces into the distal cavity where substrate must bind during regiospecific aromatic ring hydroxylation catalysis. These results provide a new structural benchmark for how activated intermediates may be formed and dispatched during diiron hydroxylase catalysis.

59 BASIC BIOLOGICAL SCIENCES↗

A cytosolic glyoxylate shunt complements the canonical photorespiratory pathway in Arabidopsis

Photorespiration functions in part to support photosynthetic performance, especially under stress such as high light, yet the underlying mechanisms are poorly understood. To identify modulators of photorespiration under high light, we have isolated genetic suppressors of the photorespiratory mutant hpr1 (hydroxypyruvate reductase 1) from Arabidopsis. A suppressor that partially rescues hpr1 is mapped to GLYR1, which encodes the cytosolic glyoxylate reductase 1 that converts glyoxylate to glycolate. Independent glyr1 mutants also partially rescue hpr1 and another photorespiratory mutant, catalase 2. Our genetic, transcriptomic and metabolic profiling analyses together reveal a connection between cytosolic glyoxylate and a non-canonical photorespiratory route mediated by HPR2, which we name the photorespiratory glyoxylate shunt. This shunt complements the canonical photorespiratory pathway and is especially critical when high photorespiratory fluxes are required and when the major photorespiratory pathway is deficient. Our findings support the metabolic flexibility of photorespiration and may help to improve crop performance under stress.

Light stress↗

Correlation-based network analysis combined with machine learning techniques highlight the role of the GABA shunt in Brachypodium sylvaticum freezing tolerance

Perennial grasses will account for approximately 16 billion gallons of renewable fuels by the year 2022, contributing significantly to carbon and nitrogen sequestration. However, perennial grasses productivity can be limited by severe freezing conditions in some geographical areas, although these risks could decrease with the advance of climate warming, the possibility of unpredictable early cold events cannot be discarded. We conducted a study on the model perennial grass Brachypodium sylvaticum to investigate the molecular mechanisms that contribute to cold and freezing adaption. The study was performed on two different B. sylvaticum accessions, Ain1 and Osl1, typical to warm and cold climates, respectively. Both accessions were grown under controlled conditions with subsequent cold acclimation followed by freezing stress. For each treatment a set of morphological parameters, transcription, metabolite, and lipid profiles were measured. State-of-the-art algorithms were employed to analyze cross-component relationships. Phenotypic analysis revealed higher adaption of Osl1 to freezing stress. Our analysis highlighted the differential regulation of the TCA cycle and the GABA shunt between Ain1 and Osl1. Osl1 adapted to freezing stress by repressing the GABA shunt activity, avoiding the detrimental reduction in fatty acid biosynthesis and the concomitant detrimental effects on membrane integrity.

54 ENVIRONMENTAL SCIENCES↗

Fabrication and characterization of shunted μ-SQUID

In order to eliminate hysteresis, we have fabricated and characterized niobium based shunted micron size superconducting quantum interference devices (μ-SQUIDs). We find a wide temperature range where these μ-SQUIDs are non-hysteretic in nature and show a very good I{sub c} vs. B oscillations in hysteretic regime and V vs. B oscillations in non-hysteretic regime. Here we report the characteristics of a shunted- μ-SQUID (Wf38LS72D5). In this device we have achieved a large voltage modulation, in non-hysteretic regime, at various temperatures including such as 1.1 mV at 6.62 K with a transfer function V{sub Φ} = 7.2mV/Φ{sub 0}. The figures within the original article PDF file, as supplied to AIP Publishing, were affected by a PDF-processing error. Consequently, the article re-flowed and pagination increased from 3 to 4 pages. This article was updated on 14 May 2014 to correct the PDF-processing error, with the scientific content remaining unchanged. Readers are advised that the replacement article PDF file contains an additional blank page to preserve the original pagination.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A capacitively shunted superconducting microbridge

A superconducting microbridge small enough to exhibit the Josephson effect has been shunted by a large external capacitance. Surprisingly little capacitive hysteresis is observed in its I-V characteristic. Prominent subgap structures are seen. The resistively shunted junction (RSJ) model fails to explain the observations.

Chiao, R. Y.↗