Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SANS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Analysis of Upper Air, Ground and Remote Sensing Data for the ATLAS Field Campaign in San Juan, Puerto Rico

The Atlas San Juan Mission was conducted in February 2004 with the main objectives of observing the Urban Heat Island of San Juan, providing high resolution data of the land use for El Yunque Rain Forest and for calibrating remote sensors. The mission was coordinated with NASA staff members at Marsha& Stennis, Goddard, and Glenn. The Airborne Thermal and Land Applications Sensor (ATLAS) from NASA/Stennis, that operates in the visual and IR bands, was used as the main sensor and was flown over Puerto Rico in a Lear 23 jet plane. To support the data gathering effort by the ATLAS sensor, remote sensing observations and upper air soundings were conducted along with the deployment of a number of ground based weather stations and temperature sensors. This presentation focuses in the analysis of this complementary data for the Atlas San Juan Mission. Upper air data show that during the days of the mission the Caribbean mid and high atmospheres were relatively dry and highly stable reflecting positive surface lifted index, a necessary condition to conduct this suborbital campaign. Surface wind patterns at levels below 850mb were dominated by the easterly trades, while the jet stream at the edge of the troposphere dominated the westerly wind at levels above 500mb. The jet stream remained at high latitudes reducing the possibility of fronts. In consequence, only 8.4 mm of precipitation were reported during the entire mission. Observation of soundings located about 150 km apart reflected minimum variations of the boundary layer across the Island for levels below 850 meters and a uniform atmosphere for higher levels. The weather stations and the temperature sensors were placed at strategic locations to observe variations across the urban and rural landscapes. Time series plot of the stations' data show that heavily urbanized commercial areas have higher air temperatures than urban and suburban residential areas, and much higher temperatures than rural areas. Temperature differences [dT(U-R)] were obtained by subtracting the values of several stations h m a reference urban station, located m the commercial area of San Juan. These time series show that the UHI peaks during the morning between 10:00am and noon to an average of 4.5 C, a temporal pattern not previously observed in similar studies for continental cities. It is also observed a high variability of the UHI with the precipitation patterns even for short events. These results may be a reflection of a large land use density by low level buildings with an apparent absence of significant heat storage effects in the urban areas, and the importance of the surrounding soil and vegetation moisture in controlling the urban tropical climate. The ATLAS data was used to determine albedo and surface temperature patterns on a 10m scale for the study area. These data were used to calibrate the spatial distribution of the surface temperature when using remote sensing images from MODIS (Moderate Resolution Imaging Spectradiometer). Surface temperatures were estimated using the land surface temperature product MODII-L2 distributed by the Land Process Distributed Active Archive Center(LP DAAC). These results show the maximum, minimum and average temperatures in San Juan and in the entire Island at a resolution of 1 km. The information retrieved from MODIS for land surface temperatures reflected similar temporal and spatial variations as the weather stations and ATLAS measurements with a highest absolute offset of about 5 C due to the differences between surface and air temperatures.

Gonzalez, Jorge E.↗

Analysis of Upper Air, Ground and Remote Sensing Data for the Atlas Field Campaign in San Juan, Puerto Rico

The general climate of the island of Puerto Rico is dominated by the easterly trade winds from the Atlantic Ocean, and during synoptically calm days by the topographic and local land surface characteristics [1]. The urban canopy of the metropolitan area of San Juan, capital city of the Island, may introduce a new microclimate that changes the characteristics of the low atmosphere and interacts with the other microclimates already present in the island. The primitive land cover and land use (LCLU) of the metropolitan area of San Juan was composed by broadleaf trees, moist soils, and very dense vegetation in general. The urban LCLU changes the balance for the mass, momentum and energy between the bottom boundary and the lower atmosphere, creating different climate conditions over urban and rural regions. Some of these differences are low relative humidity and high temperatures observed in urban areas when compared to rural areas. These in turn produces a convective circulation over the urban areas, a phenomenon compared to the sea and land breezes, commonly known as heat islands (UHI). Factors that contribute to the formation of the UHI are anthropogenic heat sources, aerosols from pollutants, fast water canalization due to the presence of buildings and streets, among others. The comparison between urban and rural climates is the most common approach to analyze the UHI. These contrasts are larger in clear and calm conditions and tend to disappear in cloudy and windy weather. The UHI was recognized in the early 1950 s as closed isotherms that separates the city from the general temperature field [2]. The impact of the urban LCLU in San Juan, Puerto Rico, was quantified calculating the difference between historical data sets for the air temperature over an identified urban area and a rural area dT(U-R). The analysis of the climatological data revealed that a UHI exists in the metropolitan area of San Juan, Puerto Rico. The data reveals a permanent urban heat island effect present in the SJMA during the year, which is increasing at a rate of 0.41oC/decade. These findings encouraged the planning and execution of an intense field campaign in February 2004 referred as the ATLAS San Juan mission. The focus of the remaining of this report is the analysis of the data for this field campaign.

Gonzalez-Cruz, Jorge E.↗

Highly Siderophile Elements as Tracers for the Subcontinental Mantle Evolution Beneath the Southwestern USA: The San Carlos and Kilbourne Hole Peridotite Xenoliths Revisited

Peridotite xenoliths from San Carlos, Arizona, and Kilbourne Hole, New Mexico, have been studied since the 1970 s to give insights into melting and metasomatism in the subcontinental mantle beneath the southwestern USA. More recently, the highly siderophile elements (HSE; Os, Ir, Ru, Rh, Pt, Pd, and Re) and the included Re-Os isotope system have been established as powerful tools for the study of mantle processes because of their range in compatibility during mantle melting and their siderophile and chalcophile geochemical behavior. Model aluminachron Re-Os ages for San Carlos and Kilbourne Hole, as well as for the nearby Dish Hill and Vulcan's Throne sites, give consistent depletion ages of around 2.2 Ga. This age can be interpreted as a single large scale mantle melting event linked to crustal formation and continental growth under the southwestern USA. Highly siderophile elements, however, may be added to depleted peridotites via melt-rock interaction, especially the more incompatible and hence mobile Pt, Pd, and Re. This may result in overprinting of the signature of melt extraction, thus abating the usefulness of Re-Os mantle extraction model ages. A comprehensive characterization of the suite of mantle xenoliths from the SW USA in terms of HSE concentrations is thus necessary to re-assess the Re-Os system for dating purposes. San Carlos peridotites are depleted to moderately fertile, as indicated by their bulk Al2O3 contents between 0.66 wt% and 3.13 wt%. Bulk Os-187/Os-188 in San Carlos peridotites range from 0.1206 to 0.1357. In contrast, Kilbourne Hole peridotites tend to be more fertile with Al2O3 between 2.11 and 3.78 wt%, excluding one extremely depleted sample with 0.30 wt% Al2O3, and have Os-187/Os-188 between 0.1156 and 0.1272, typical for mantle peridotites. No large fractionation between the more compatible HSE Os, Ir, and Ru are observed. The more incompatible HSE Re, Pd, and to a minor extent, Pt, however, are depleted in a number of samples by factors of up to 4 for Pt, 6 for Pd, and 20 for Re, compared to primitive mantle estimates. This is in agreement with previous studies from the same locales, which demonstrated the presence of different populations of mantle xenoliths having undergone various degrees of melt extraction. The depletion of the more incompatible elements (Re, Pd, and Pt) also suggests that the HSE budgets of the SW USA peridotites were primarily established by extraction of basaltic melt, and reflect only minor influence from later episodes of metasomatism. Model Re-Os ages obtained from San Carlos and Kilbourne Hole xenoliths may thus reflect ages of crustal formation and mantle depletion in the SW USA region.

vanAcken, D.↗

Absorption at San Antonio with 3-Wavelength Photo Acoustic Soot Spectrometer, Tricolor Absorption Photometer (ASAPT) Field Campaign Report

Fine particulate matter (PM2.5; particulate matter with an aerodynamic diameter of 2.5μm and smaller) samples were collected at the University of Texas, San Antonio (UTSA) campus (29.57901, -98.62889) from May 15-30. An additional measurement at the UTSA site included aerosol absorption coefficient of PM1 (particulate matter with an aerodynamic diameter of 1.0μm and smaller) using a tricolor absorption photometer (TAP) (Brechtel Mfg. Inc., Hayward, California). The sampling site is approximately 15 miles northwest of downtown San Antonio and in close proximity to major highway 10 and is just south of a forested area. The setup of the sampler and TAP and collection of PM2.5 samples were completed by Baylor University’s graduate student, Subin Yoon. Three three-wavelength photoacoustic soot spectrometers (PASS-3s) were shipped to San Antonio for testing and possible data collection. R. Subramanian went to San Antonio to lead this effort with assistance from Yoon. Each instrument had a critical flaw that inhibited its use for this campaign. Two instruments had low laser power for each wavelength; in addition, there were power and overheating issues with the one instrument that was installed on a test basis. The third instrument had computer issues that impeded any testing. In short, these three instruments would require a major overhaul in terms of lasers and computer systems to be brought back to field capability. As a result, the filter-based optical measurements were added to the campaign as an alternate measurement that would provide mass absorption efficiency at a single wavelength, but no scattering measurement. The TAP instrument was successfully installed and collected data for San Antonio, but full use of the data would have required a co-located scattering measurement. This campaign was co-located with a Texas Commission on Environmental Quality (TCEQ) ozone field study. That TCEQ field study was a collaboration of the University of Houston (PI James Flynn), Rice University (Co-PI Robert Griffen), and Baylor University (Co-PIs Rebecca Sheesley and Sascha Usenko).

aerosols, tricolor absorption photometer, three-wa↗

Economics of Solar with Storage for Municipal Sites in the City of San Diego [Slides]

This analysis was conducted under the first round of the Solar Energy Innovation Network (SEIN); a program led by the National Renewable Energy Laboratory (NREL). The program assembles diverse teams of stakeholders to research solutions to real-world challenges associated with solar energy adoption. This analysis supported the efforts of the San Diego SEIN team, which consists of the City of San Diego and the Clean Coalition. The City of San Diego aims to deploy solar and storage to support energy resiliency, environmental quality, and affordability of the electricity supply. The team has estimated the total potential for solar deployment across the city, designed a program proposal for utilizing the total solar potential, completed detailed economic analysis of solar options on municipal facilities, conducted stakeholder workshops to explore solar compensation options, and is exploring opportunities for solar-plus-storage to improve resiliency at critical facilities. This analysis supports the team's work by analyzing the techno-economic potential of solar photovoltaics (PV) and lithium-ion battery energy storage at municipal sites in the City of San Diego.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Unified User-Friendly Instrument Control and Data Acquisition System for the ORNL SANS Instrument Suite

In an effort to upgrade and provide a unified and improved instrument control and data acquisition system for the Oak Ridge National Laboratory (ORNL) small-angle neutron scattering (SANS) instrument suite—biological small-angle neutron scattering instrument (Bio-SANS), the extended q-range small-angle neutron scattering diffractometer (EQ-SANS), the general-purpose small-angle neutron scattering diffractometer (GP-SANS)—beamline scientists and developers teamed up and worked closely together to design and develop a new system. We began with an in-depth analysis of user needs and requirements, covering all perspectives of control and data acquisition based on previous usage data and user feedback. Our design and implementation were guided by the principles from the latest user experience and design research and based on effective practices from our previous projects. In this article, we share details of our design process as well as prominent features of the new instrument control and data acquisition system. The new system provides a sophisticated Q-Range Planner to help scientists and users plan and execute instrument configurations easily and efficiently. The system also provides different user operation interfaces, such as wizard-type tool Panel Scan, a Scripting Tool based on Python Language, and Table Scan, all of which are tailored to different user needs. The new system further captures all the metadata to enable post-experiment data reduction and possibly automatic reduction and provides users with enhanced live displays and additional feedback at the run time. We hope our results will serve as a good example for developing a user-friendly instrument control and data acquisition system at large user facilities.

47 OTHER INSTRUMENTATION↗

Importance of river water recharge to the San Joaquin Valley groundwater system

Groundwater is not a sustainable resource, unless abstraction is balanced by recharge. Identifying the sources of recharge in a groundwater basin is critical for sustainable groundwater management. In this paper, we studied the importance of river water recharge to groundwater in the south-eastern San Joaquin Valley (24,000 km 2 , population 4 million). We combined dissolved noble gas concentrations, stable isotopes, tritium, and carbon-14 analyses to analyse the sources, mechanisms, and timescales of groundwater recharge. Area-representative groundwater sampling and numerical model input data enabled a stable isotope mass balance and quantitative estimates of river and local recharge. River recharge, identified by a lighter stable isotope signature, represents 47 ± 4% of modern groundwater in the San Joaquin Valley (recharged after 1950) but only 26 ± 4% of premodern groundwater (recharged before 1950). This implies that the importance of river water recharge in the San Joaquin valley has nearly doubled and is likely the result of a 40% increase in total recharge, caused by river water irrigation return flows and increased stream depletion and river recharge due to groundwater pumping. Compared with the large and long-duration capacity for water storage in the subsurface, storage of water in rivers is limited in time and volume, as evidenced by cold river recharge temperatures resulting from fast infiltration and recharge. Finally, groundwater banking of seasonal surface water flows and expansion of managed aquifer recharge practices therefore appear to be a natural and promising method for increasing the resilience of the San Joaquin Valley water supply system.

54 ENVIRONMENTAL SCIENCES↗

Unravelling the origins of shale nanoporosity using small-angle neutron scattering (SANS)

Hydrocarbon production from tight rocks is constrained by slow diffusion within the shale matrix, limited by small pore sizes and low permeability. The nanopore proportion and size distribution significantly influence matrix permeability, a key property for optimizing hydrocarbon recovery and supporting hydrogen production while minimizing environmental impacts. Small-angle neutron scattering (SANS) has been an important tool for exploring the characteristics and structure of shale nanopores. This study used SANS to analyze nanoporosity and pore size distribution (<100 nm) in tight rocks with varying compositions to determine the influence of rock heterogeneity on SANS measurements. Results showed that nanoporosity correlates with clay content, with the highest clay-rich shale (52.48 wt% clay) exhibiting 8.8 % nanoporosity. SANS also revealed more nanopores than traditional nitrogen adsorption measurements, affirming its ability to reflect bulk mineralogy and upholding the relevance of experimental findings using this technique to optimize field operational approaches.

03 NATURAL GAS↗

The performance of magnetic lens for focusing VCN-SANS.

We have developed a prototype rotating-permanent magnet sextupole lens (named rot-PMSx) for more efficient experiments with neutron beams in time of flight (ToF) mode. This lens can modulate the focusing strength over range 1.5 x 10{sup 4} T/m{sup 2} {le} g' {le} 5.9 x 10{sup 4} T/m{sup 2}. Synchronization between the modulation and the beam pulse produces a focused beam without significant chromatic aberration. We anticipate that this lens could be utilized in focusing small angle neutron scattering (SANS) instruments for novel approach to high resolution SANS. We carried out experiments testing the principle of this lens at the very cold neutron (VCN) beamline (PF2) at Institut Laue-Langevin (ILL), France. The focused beam image size at the detector was kept constant at the same beam size as the source ({approx} 3 mm) over a wavelength range of 30 {angstrom} {le} {lambda} {le} 48 {angstrom} in focal length of {approx} 1.14 m. The flux gain was about 12 relative to a beam without focusing, and the depth of focus was quite large. These results show the good performance of this lens and the system. Thereupon we have demonstrated the performance of this test bed for high resolution focusing of VCN-SANS for a well-studied softmatter sample; a deuterium oxide solution of Pluronic F127, an (PEO){sub 100}(PPO){sub 65}(PEO){sub 100} tri-block copolymer in deuterium oxide. The results of the focusing experiment and the focusing VCN-SANS are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The small-angle neutron scattering extension in MCNPX and the SANS cross section for nanodiamonds

Detonation nanodiamonds provide an intriguing prospect for the development of a very cold neutron (VCN) source or as a high albedo material for VCN reflection helping to control leakage of cold and very cold neutrons in a moderator. The investigation of source and reflector designs necessitates the development of new simulation tools for existing Monte Carlo codes that include small angle neutron scattering (SANS). The SANS extension in MCNPX 2.7 provides an analytical model of hard-sphere scattering with variable scattering particle sizes, size distributions, and packing fractions in order to supplement currently existing scattering kernels as well as the capability to read an experimentally determined small angle neutron scattering profile from a data file. The SANS extension is discussed and compared to nanodiamond SANS measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Urban microclimate and its impact on building performance: A case study of San Francisco

Urban microclimate exerts an increasing influence on urban buildings, energy, and sustainability. This study uses 10-year measured hourly weather data at 27 sites in San Francisco, California, to (1) analyze and visualize the urban microclimate patterns and urban heat island effect; (2) simulate annual energy use and peak electricity demand of typical large office buildings and large hotels to investigate the influence of urban microclimate on building performance; (3) simulate indoor air temperature of a single-family house without air-conditioning during the record three-day heatwave of 2017, to quantify the divergence of climate resilience due to urban microclimate effect. Results show significant microclimate effects in San Francisco with up to 11 °C outdoor air temperature difference between the coastal and downtown areas on September 1, 2017, during the record three-day heatwave. The simulated energy results of the prototype large office and large hotel buildings using the 2017 weather data show over 100% difference in annual heating energy use and 65% difference in annual cooling energy use across different stations; as well as up to 30% difference in peak cooling electricity demand. The impacts on annual site or source energy use are minimal (less than 5%) as cooling and heating in a mild climate are a relatively small portion of overall building energy use in San Francisco. Results also show the microclimate effects influence indoor air temperature of unconditioned homes by up to 5 °C. Newer buildings and homes are much less affected by microclimate effects due to more stringent performance requirements of the building envelope and energy systems. Furthermore, these findings inform that San Francisco microclimate variations should be considered in urban energy planning, building energy codes and standards, as well as heat resilience policymaking.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Controlled Deuteration of Phosphatidylcholine Biosynthetically Produced from Engineered Escherichia coli for SANS Studies

Deuterated phosphatidylcholine (PC) was produced from engineered Escherichia coli (E. coli) BL21 cells grown in deuterated media. The levels of deuteration could be controlled by growing cells in different combinations of deuterated and nondeuterated water, glycerol, and choline, which were analyzed by NMR, mass spectrometric analysis, and small-angle neutron scattering (SANS). By growing cells in deuterium oxide (D2O) in the presence of fully deuterated glycerol and choline, perdeuterated PC (PC-DDD) was produced via this method. The average neutron contrast match points of isolated PC were experimentally determined using SANS. For partially deuterated PC lipids, SANS showed match points of 92 ± 8% D2O for lipids with deuterated fatty acyl chains and glycerol (PC-DDH) and 81 ± 2% D2O for lipids with only deuterated fatty acyl chains (PC-DHH). Our results will benefit SANS studies that utilize deuterated PC lipids as mimetics of lipid bilayers or membrane-like models for structural studies of biomolecular systems.

Zhang, Qiu [ORNL] (ORCID:0000000255064955)↗

AmeriFlux FLUXNET-1F US-LS2 San Pedro River Lewis Springs Savanna

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-LS2 San Pedro River Lewis Springs Savanna. This is the FLUXNET version of the carbon flux data for the site US-LS2 San Pedro River Lewis Springs Savanna produced by applying the standard ONEFlux (1F) software. Site Description - A riparian savanna located on an old alluvial terrace about 0.5 km from the banks of the entrenched San Pedro River in southeastern Arizona USA. Site climate is semiarid with monsoonal (Jul-Sep) rainfall. The trees access groundwater (depth of ~7 m)from an alluvial aquifer recharged elsewhere. Therefore, site water balance is not closed and ET greatly exceeds precipitation. The perennial bunchgrasses use primarily rainfall. This groundwater-using ecosystem is far more ebulliant and productive than the upland vegetation around it (shrublands and grasslands) outside of the San Pedro River corridor.

Scott, Russell↗

AmeriFlux FLUXNET-1F US-LS1 San Pedro River Lewis Springs Sacaton Grassland

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-LS1 San Pedro River Lewis Springs Sacaton Grassland. This is the FLUXNET version of the carbon flux data for the site US-LS1 San Pedro River Lewis Springs Sacaton Grassland produced by applying the standard ONEFlux (1F) software. Site Description - This is a riparian grassland located along an old alluvial terrace along the banks of the entrenched San Pedro River in southeastern Arizona. Site climate is semiarid with monsoonal (Jul-Sep) rainfall. The grasses access groundwater (depth of 2-4 m)from an alluvial aquifer recharged elsewhere. Site water balance is not closed and ET greatly exceeds precipitation. The perennial bunchgrasses use both rainfall, groundwater and occasional flood water. This groundwater-using ecosystem is far more ebulliant and productive than the upland vegetation around it (shrublands and grasslands) outside of the San Pedro River corridor.

Scott, Russell [USDA-ARS]↗

Building a Solar Powered Home in a Historic Neighborhood. A Case Study with CVF Homes, the City of San Antonio Office of Historic Preservation and the Lavaca Neighborhood Association

A Texas collaboration is working to streamline and enable an increase in photovoltaic capacity. The City of San Antonio has made tremendous progress in recent years in the area of solar energy installations on residences. These projects have been great successes, though not without the usual challenges associated with solar energy installations. The City has also seen an increased interest in solar energy systems in official “historic” neighborhoods. These installations have a potential for added challenges, as neighborhoods designated “historic” have additional restrictions, aside from standard building codes, about what changes and upgrades can be done to the exterior. This is in an effort to maintain the historic qualities of the homes and preserve the historical nature of the neighborhoods in which they are present. The purpose of this case study was to examine the construction of a new, single family home, with an included solar energy system, in an official historic neighborhood in San Antonio. Build San Antonio Green hoped to uncover what specific additional challenges the builder faced when working in a historic neighborhood and how those challenges were overcome, to serve as a model for other builders wishing to install solar energy systems in historic neighborhoods. This is of particular importance, as the City of San Antonio has more than 20 officially designated historic neighborhoods, and without proper knowledge of how to comply with the additional regulations, contractors, builders, and solar installers could potentially miss out on tremendous opportunities.

14 SOLAR ENERGY↗

Spatio–Temporal Analysis of Deformation at San Emidio Geothermal Field, Nevada, USA Between 1992 and 2010

Although subsidence has been observed at the San Emidio geothermal field in Nevada using interferometric synthetic aperture radar since the early 1990s, the spatial extent and temporal evolution of the subsidence have not heretofore been quantified. Furthermore, the weather conditions and geographic location of San Emidio negatively affect interferometric image quality, causing low correlation amongst pairs. To address this, we introduce a new method for selecting pairs in areas of low correlation and small deformation signal using a minimum spanning tree method with a measure of image quality as the weighting criterion. We validate our pair selection approach by comparing our data products to SqueeSAR TM data products from a previous study at San Emidio. We also develop a deformation model which characterizes the spatial extent of subsidence at San Emidio in terms of volume change of the reservoir. After applying this deformation model to our data set of interferometric pairs, we examine the temporal relationship of the observed deformation with production and injection operations associated with geothermal power production.

Reinisch, Elena C. (ORCID:0000000252211921)↗

A simulation of the San Andreas fault experiment

The San Andreas Fault Experiment, which employs two laser tracking systems for measuring the relative motion of two points on opposite sides of the fault, was simulated for an eight year observation period. The two tracking stations are located near San Diego on the western side of the fault and near Quincy on the eastern side; they are roughly 900 kilometers apart. Both will simultaneously track laser reflector equipped satellites as they pass near the stations. Tracking of the Beacon Explorer C Spacecraft was simulated for these two stations during August and September for eight consecutive years. An error analysis of the recovery of the relative location of Quincy from the data was made, allowing for model errors in the mass of the earth, the gravity field, solar radiation pressure, atmospheric drag, errors in the position of the San Diego site, and laser systems range biases and noise. The results of this simulation indicate that the distance of Quincy from San Diego will be determined each year with a precision of about 10 centimeters. This figure is based on the accuracy of earth models and other parameters available in 1972.

Agreen, R. W.↗

A simulation of the San Andreas fault experiment

The San Andreas fault experiment (Safe), which employs two laser tracking systems for measuring the relative motion of two points on opposite sides of the fault, has been simulated for an 8-yr observation period. The two tracking stations are located near San Diego on the western side of the fault and near Quincy on the eastern side; they are roughly 900 km apart. Both will simultaneously track laser reflector equipped satellites as they pass near the stations. Tracking of the Beacon Explorer C spacecraft has been simulated for these two stations during August and September for 8 consecutive years. An error analysis of the recovery of the relative location of Quincy from the data has been made, allowing for model errors in the mass of the earth, the gravity field, solar radiation pressure, atmospheric drag, errors in the position of the San Diego site, and biases and noise in the laser systems. The results of this simulation indicate that the distance of Quincy from San Diego will be determined each year with a precision of about 10 cm. Projected improvements in these model parameters and in the laser systems over the next few years will bring the precision to about 1-2 cm by 1980.

Agreen, R. W.↗