Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Bipolar Electrode Sample Preparation Devices

An analyte selection device can include: a body defining a fluid channel having a channel inlet and channel outlet; a bipolar electrode (BPE) between the inlet and outlet; one of an anode or cathode electrically coupled with the BPE on a channel inlet side of the BPE and the other of the anode or cathode electrically coupled with the BPE on a channel outlet side of the BPE; and an electronic system operably coupled with the anode and cathode so as to polarize the BPE. The fluid channel can have any shape or dimension. The channel inlet and channel outlet can be longitudinal or lateral with respect to the longitudinal axis of the channel. The BPE can be any metallic member, such as a flat plate on a wall or mesh as a barrier BPE. The anode and cathode can be located at a position that polarizes the BPE.

Wang, Yi↗

Examining the Uppermost Surface of the Lunar Regolith

This slide presentation reviews the examination of the uppermost surface of the lunar regolith. It shows the mechanism (i.e. a Clam Shell Sampling Device) that was used to retrieve samples of the surface of the lunar soil. Samples were obtained from the devices, and they were examined in the scanning electron microscope (SEM). Using a lunar simulant, JSC-1a, test were run to ascertain if the sample from the clam shell device were biased due to the collection. The results of the test were that all the fine grains analyzed to the limit of the capabilities were found to be lunar in composition, though non-lunar contaminants may exist in the submicron population. Further work is required, though the initial study shows that the uppermost surface is enriched in fine (< 2 micron grains) compared to the bulk soil.

Noble, Sarah↗

The Uppermost Surface of the Moon

The Ap16 Clam shell Sampling Devices (CSSDs) were designed to sample the uppermost surface of lunar soil. The two devices used beta cloth (69003) and velvet (69004) to collect soil from the top 100 and 500 micrometers of the soil, respectively. Due to the difficulty of the sampling method, little material was collected and as a result little research has been done on these samples. Initial studies attempted to look at the material which had fallen off of the fabrics and was subsequently collected from inside the sample containers. However, this material was highly fractionated and did not provide an adequate picture of the uppermost surface. Recently, samples were obtained directly from the beta cloth using carbon tape. While still fractionated, these samples provide a unique glimpse into the undisturbed soil exposed at the lunar surface.

Noble, Sarah K.↗

Systems and Methods for Gravity-Independent Gripping and Drilling

Systems and methods for gravity independent gripping and drilling are described. The gripping device can also comprise a drill or sampling devices for drilling and/or sampling in microgravity environments, or on vertical or inverted surfaces in environments where gravity is present. A robotic system can be connected with the gripping and drilling devices via an ankle interface adapted to distribute the forces realized from the robotic system.

Parness, Aaron↗

Introducing “ The Integrator ”: A novel technique to monitor environmental flow systems

Abstract We introduce “ The Integrator ,” a novel technique to quantify transport and reaction metrics commonly used to characterize flow systems. This development consists of two products: (1) The Integrator sampling device and (2) its supporting mathematical framework, which is compatible with semi‐continuous sensor data. The use of The Integrator device simplifies the logistics of sample collection and greatly reduces the number of samples needed, making it ideal to characterize systems that are: (1) difficult to access, (2) large and thus intractable or highly heterogeneous, and (3) highly instrumented otherwise but where a more holistic, mechanistic understanding may be gained by monitoring one or more currently untracked elements. We tested and validated The Integrator technique using experimental data collected from a heart rate monitor (high‐quality, high‐frequency data in response to known excitation events) and solute tracer experiments conducted in two contrasting (fourth and seventh order) rivers. In the Supporting Information , we provide details concerning the design of The Integrator device used in our field case studies and provide insight into potential improvements. Despite our case studies focus on the analysis of conservative and reactive transport of solutes in rivers, the principles behind The Integrator technique can be used to monitor water quality in hyporheic zones, aquifers, wetlands, swamps, karsts, oceans, wastewater treatment plants, pipe networks, and air quality. Furthermore, special arrangements of Integrator devices can be used to gather data at spatial and temporal resolutions that are currently unattainable due to high transportation and/or personnel costs.

54 ENVIRONMENTAL SCIENCES↗

Onsite Gaseous Centrifuge Enrichment Plant UF6 Cylinder Destructive Analysis

The IAEA safeguards approach for gaseous centrifuge enrichment plants (GCEPs) includes measurements of gross, partial, and bias defects in a statistical sampling plan. These safeguard methods consist principally of mass and enrichment nondestructive assay (NDA) verification. Destructive assay (DA) samples are collected from a limited number of cylinders for high precision offsite mass spectrometer analysis. DA is typically used to quantify bias defects in the GCEP material balance. Under current safeguards measures, the operator collects a DA sample from a sample tap following homogenization. The sample is collected in a small UF6 sample bottle, then sealed and shipped under IAEA chain of custody to an offsite analytical laboratory. Current practice is expensive and resource intensive. We propose a new and novel approach for performing onsite gaseous UF6 DA analysis that provides rapid and accurate assessment of enrichment bias defects. DA samples are collected using a custom sampling device attached to a conventional sample tap. A few micrograms of gaseous UF6 is chemically adsorbed onto a sampling coupon in a matter of minutes. The collected DA sample is then analyzed onsite using Laser Ablation Absorption Ratio Spectrometry-Destructive Assay (LAARS-DA). DA results are determined in a matter of minutes at sufficient accuracy to support reliable bias defect conclusions, while greatly reducing DA sample volume, analysis time, and cost.

Uranium Enrichment Laser Safeguards↗

Variable-Temperature-Gradient Device for Solidification Research

Device for research in solidification and crystal growth allows crystallization of melt observed as occurs. Temperature gradient across melt specimen increased or decreased rapidly while solidification front proceeds at constant speed across sample. Device moves sample at same speed, thereby holding position of liquid/solid interface stationary within field of optical microscope. Device, variabletemperature-gradient microscope stage, used to study crystal growth at constant rate while thermal driving force is varied.

Kaukler, W. F.↗

Sink or source? Insights into the behavior of copper and zinc in the sediment porewater of a constructed wetland by peepers

The H-02 free water surface constructed wetland has been applied to remove heavy metals, mainly copper (Cu) and zinc (Zn), from wastewater on the Savannah River Site (Aiken, SC, USA). More and more studies focus on the metal behavior between the sediment and the overlying water, which directly reflects the stability of metals after sedimentation in constructed wetlands. This study focused on the biogeochemical pathways in metal bioavailability and remobilization in the sediment after metals were removed from the overlying water. The dialysis sampling devices (peepers) were used to collect porewater samples from eight depths in the sediment for the measurement of Cu, Zn, dissolved organic carbon (DOC), and major anions (sulfate and chloride). Surface water samples were also collected for the measurement of Cu, Zn, DOC, and anions. Different temporal trends were observed for dissolved Cu between the surface and bottom waters, but not for dissolved Zn. There were no obvious changes in porewater metal concentrations with increasing depths in the sediment. Sediment served as a sink for Cu as only 3% of porewater samples showed higher labile Cu concentrations than the surface water during the entire year. Furthermore, sediment served as a source for Zn in summer and winter as 32% of porewater samples showed higher labile Zn concentrations than the surface water, and these samples were collected at all sediment depths. We think the seasonal changes in the behaviors of Cu and Zn were primarily controlled by the sulfur dynamics and the metal removal processes in the constructed wetland, as well as the different complexing chemistry between Cu and Zn. Also, our study supports that peeper is a powerful tool for studying the biogeochemistry of metals in the sediment.

54 ENVIRONMENTAL SCIENCES↗

Spatiotemporal Changes in Trace Metal Bioavailability in the Sediment Pore water of a Constructed Wetland Using Passive Pore water Samplers

Sediments in aquatic systems often act as a major sink for contaminants. Diffusive gradient in thin films (DGTs) and in situ equilibrium dialysis samplers (peepers) are two major in situ pore water sampling devices that overcome the problems associated with conventional pore water sampling methods. In the present study, DGTs and peepers were used to study the spatial and seasonal effects (cool months, October–February; warm months, May–September) on metal bioavailability in the H‐02 constructed wetland and the sink versus source role of the sediments by calculating the metal resupply capacity. Data showed similar seasonal trends in metal concentrations using passive samplers, peepers, and DGTs. Pooled Cu and Zn concentrations measured using DGTs were lower in warm months (1.67 ± 1.50 and 2.62 ± 0.68 μg L –1 , respectively, p < 0.001) versus in cool months (2.12 ± 0.65 and 5.58 ± 1.33 μg L –1 , respectively, p < 0.001; mean ± 95% confidence interval). Sulfate (SO 4 2− ) concentrations were significantly (p = 0.0139) lower in warm months (averaged at 0.22 ± 0.05 mg L –1 ) compared to in cool months (0.16 ± 0.05 mg L –1 ). The increase in SO 4 2− concentration is an indicator of the lower activity of sulfate‐reducing bacteria, which need SO 4 2− during anaerobic respiration, in which SO 4 2− is reduced to sulfide (S 2– ) that forms insoluble salts with Cu and Zn, which could partially explain the higher bioavailability of these metals in the cool season. Metal resupply capacity of the sediments was mostly <0.2 for Cu and Zn. Taken together, the H0‐2 wetland sediments mostly acted as a sink to both Cu and Zn over the course of the present study. Environ Toxicol Chem 2023;42:2726–2736. © 2023 The Authors. Environmental Toxicology and Chemistry published by Wiley Periodicals LLC on behalf of SETAC.

54 ENVIRONMENTAL SCIENCES↗

OMH3075 Hall Effect Sensor Total Ionizing Dose Test Report

The purpose of this test was to characterize the OMH3075 Hall Effects sensor degradation for total dose response. The device samples were exposed to low dose irradiations using gamma radiation. Device parameters such as magnetic operating points, leakage currents, supply currents, and rise and fall times were investigated.

Forney, James↗

Sample processing approach for detection of ricin in surface samples

With several ricin contamination incidents reported over the past decade, rapid and accurate methods are needed for environmental sample analysis, especially after decontamination. A sample processing method was developed for common surface sampling devices to improve the limit of detection and avoid false negative/positive results for ricin analysis. Potential assay interferents from the sample matrix (bleach residue, sample material, wetting buffer), including reference dust, were tested using a Time-Resolved Fluorescence (TRF) immunoassay. Test results suggested that the sample matrix did not cause the elevated background fluorescence sometimes observed when analyzing post-bleach decontamination samples from ricin incidents. Furthermore, sample particulates (80 mg/mL Arizona Test Dust) did not enhance background fluorescence or interfere with ricin detection by TRF. These results suggested that high background fluorescence in this immunoassay could be due to labeled antibody quality and/or quantity issues. Centrifugal ultrafiltration devices were evaluated for ricin concentration as a part of sample processing. Up to 30-fold concentration of ricin was observed by the devices, which serve to remove soluble interferents and could function as the front-end sample processing step to other ricin analytical methods. Here, the procedure has the potential to be used with a broader range of environmental sample types and with other potential interferences and to be followed by other ricin analytical methods, although additional verification studies would be required.

54 ENVIRONMENTAL SCIENCES↗

Comparative Studies of AlGaAs/InGaAs Enhancement/Depletion-Mode High Electron Mobility Transistors with Virtual Channel Layers by Hybrid Gate Recesses Approaches

Unlike the conventional GaAs- and InP-based enhancement/depletion-mode (E/D-mode) transistors, the improved gate characteristics of the AlGaAs/InGaAs E-mode high electron mobility transistors (HEMTs) by way of hybrid gate recesses to remove the n-AlAs/i-GaAs/n-AlGaAs virtual channel layers upon 2DEG channels are demonstrated. As compared to the D-mode device (sample A), the gate reverse currents are effectively reduced by 45 and 102 times for the E-mode devices with additional gate recess time of 24 s (sample B) and 30 s (sample C) to remove part of the virtual channel layers, respectively. Under gate forward bias, the hybrid gate recesses also enable the gate turn-on voltages to increase. Furthermore, the threshold voltages of –1.25, 0.09, and 0.22 V are observed in the samples A, B, and C, respectively. The maximum transconductances of 187.3, 209.2, and 243.4 mS/mm and saturation current density of 482.8, 410.6, and 347.4 mA/mm are obtained in the samples A, B, and C, respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗