Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLE HOLDERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Integrated sample-handling and mounting system for fixed-target serial synchrotron crystallography

Serial synchrotron crystallography (SSX) is enabling the efficient use of small crystals for structure–function studies of biomolecules and for drug discovery. An integrated SSX system has been developed comprising ultralow background-scatter sample holders suitable for room and cryogenic temperature crystallographic data collection, a sample-loading station and a humid `gloveless' glovebox. The sample holders incorporate thin-film supports with a variety of designs optimized for different crystal-loading challenges. These holders facilitate the dispersion of crystals and the removal of excess liquid, can be cooled at extremely high rates, generate little background scatter, allow data collection over >90° of oscillation without obstruction or the risk of generating saturating Bragg peaks, are compatible with existing infrastructure for high-throughput cryocrystallography and are reusable. The sample-loading station allows sample preparation and loading onto the support film, the application of time-varying suction for optimal removal of excess liquid, crystal repositioning and cryoprotection, and the application of sealing films for room-temperature data collection, all in a controlled-humidity environment. The humid glovebox allows microscope observation of the sample-loading station and crystallization trays while maintaining near-saturating humidities that further minimize the risks of sample dehydration and damage, and maximize working times. This integrated system addresses common problems in obtaining properly dispersed, properly hydrated and isomorphous microcrystals for fixed-orientation and oscillation data collection. Its ease of use, flexibility and optimized performance make it attractive not just for SSX but also for single-crystal and few-crystal data collection. Fundamental concepts that are important in achieving desired crystal distributions on a sample holder via time-varying suction-induced liquid flows are also discussed.

47 OTHER INSTRUMENTATION↗

Design of an ultrahigh vacuum transfer mechanism to interconnect an oxide molecular beam epitaxy growth chamber and an x-ray photoemission spectroscopy analysis system

We designed a mechanism and the accompanying sample holders to transfer between a VEECO 930 oxide molecular beam epitaxy (MBE) and a PHI Versa Probe X-ray photoemission spectroscopy (XPS) chamber within a multiple station growth, processing, and analysis system through ultrahigh vacuum (UHV). The mechanism consists of four parts: (1) a platen compatible with the MBE growth stage, (2) a platen compatible with the XPS analysis stage, (3) a sample coupon that is transferred between the two platens, and (4) the accompanying UHV transfer line. The mechanism offers a robust design that enables transfer back and forth between the growth chamber and the analysis chamber, and yet is flexible enough to allow transfer between standard sample holders for thin film growth and masked sample holders for making electrical contacts and Schottky junctions, all without breaking vacuum. We used this mechanism to transfer a barium strontium titanate thin film into the XPS analysis chamber and performed XPS measurements before and after exposing the sample to the air. After air exposure, a thin overlayer of carbon was found to form and a significant shift ({approx}1 eV) in the core level binding energies was observed.

36 MATERIALS SCIENCE↗

Calorimetric method of ac loss measurement in a rotating magnetic field

A method is described for calorimetric ac-loss measurements of high-T{sub c} superconductors (HTS) at 80 K. It is based on a technique used at 4.2 K for conventional superconducting wires that allows an easy loss measurement in parallel or perpendicular external field orientation. This paper focuses on ac loss measurement setup and calibration in a rotating magnetic field. This experimental setup is to demonstrate measuring loss using a temperature rise method under the influence of a rotating magnetic field. The slight temperature increase of the sample in an ac-field is used as a measure of losses. The aim is to simulate the loss in rotating machines using HTS. This is a unique technique to measure total ac loss in HTS at power frequencies. The sample is mounted on to a cold finger extended from a liquid nitrogen heat exchanger (HEX). The thermal insulation between the HEX and sample is provided by a material of low thermal conductivity, and low eddy current heating sample holder in vacuum vessel. A temperature sensor and noninductive heater have been incorporated in the sample holder allowing a rapid sample change. The main part of the data is obtained in the calorimetric measurement is used for calibration. The focus is on the accuracy and calibrations required to predict the actual ac losses in HTS. This setup has the advantage of being able to measure the total ac loss under the influence of a continuous moving field as experienced by any rotating machines.

42 ENGINEERING↗

Qualification of Processing Batches for Tank Closure Cesium Removal Through In-Tank Batch Contact Testing - 20470

The Tank Closure Cesium Removal (TCCR) process at the Savannah River Site (SRS) is currently processing waste from Tank 10H, generating decontaminated salt solution that is sent to Tank 11H. Transfers out of Tank 11H are then disposed of on site as a grout wasteform in the SRS Saltstone Processing Facility. This is a full-scale demonstration of the use of Crystalline Silicotitanate (CST) for the decontamination of aqueous nuclear waste supernate. CST primarily removes cesium from the high sodium alkaline feed, but also adsorbs strontium, actinides, and some other trace metals. The TCCR unit is an at-tank set of four ion exchange columns, with two typically being operated in series during waste processing. Tank 10H is serving a dual function as both the salt dissolution tank as well as the feed tank for the TCCR system. Prior to operation of TCCR, Tank 10H must undergo dissolution campaigns, dissolving the salt cake to form an aqueous salt solution (supernate). After each dissolution campaign, the supernate created must be qualified prior to processing through the TCCR system. Qualification includes detailed characterization of the supernate as well as in-tank batch contact tests to determine the equilibrium loading of Cs-137 on the CST ion exchange media (IONSIV{sup TM} R9120-Ba). In support of the in-tank batch contact testing, Savannah River National Laboratory (SRNL) developed a CST sample holder, also referred to as a 'tea-bag', to hold a measured amount (∼0.1 grams) of pretreated CST between stainless steel screens. The tea-bag fits within a standard stainless steel sample vial that has been modified to allow the flow of supernate to the CST. This sample holder is then immersed in the waste tank allowing free contact between the CST beads and the surrounding liquid, at an effectively infinite liquid-to-solid phase ratio. A pair of tea-bags are deployed in the tank for a period of 10 days for each batch, after which the CST is recovered, digested, and analyzed to determine the loading of cesium isotopes on the CST. This result then supports the TCCR column thermal loading limits for processing as part of the TCCR safety basis. This paper will discuss the design and testing of the CST sample holder, as well as results from the first few batches of waste qualified and subsequently processed through the TCCR system. In addition, results from analyses of Tank 11H samples, showing decontamination of the product will be included. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Atomically precise (catalytic) particles synthesized by a novel cluster deposition instrument

We report a new high vacuum instrument which is dedicated to the preparation of well-defined clusters supported on model and technologically relevant supports for catalytic and materials investigations. The instrument is based on deposition of size selected metallic cluster ions that are produced by a high flux magnetron cluster source. The throughput of the apparatus is maximized by collecting and focusing ions utilizing a conical octupole ion guide and a linear ion guide. The size selection is achieved by a quadrupole mass filter. The new design of the sample holder provides for the preparation of multiple samples on supports of various sizes and shapes in one session. After cluster deposition onto the support of interest, samples will be taken out of the chamber for a variety of testing and characterization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PLASMA ETCHING OF A SINGLE-CELL RF CAVITY -ASYMMETRIC ELECTRONEGATIVE DISCHARGE

We are pursuing the use of environmentally friendly dry etching of SRF cavity in Ar/Cl2 discharge. We have successfully demonstrated on flat samples that in a barrel-type reactor etching rates are comparable to the wet process, such as BCP or EP. The geometry of SRF cavities made of bulk Nb defines the use of asymmetric RF discharge configuration for plasma etching. The asymmetry in the surface area of a driven and grounded electrode creates a difference in the voltage drop over the plasma sheath attached to the driven electrode and the plasma sheath attached to the cavity surface. A specially designed single cell cavity is used to study these asymmetric discharges which contain 20 sample holder holes symmetrically placed over the cell. These sample holder holes can be used for both diagnostics and sample etching purposes. The approach is to combine radially and spectrally resolved profiles of optical intensity of the discharge with direct etched surface diagnostics to obtain an optimum combination of etching rates, roughness and homogeneity in a variety of discharge types, conditions and sequences.

Upadhyay, Janardan↗

A versatile elevated-pressure reactor combined with an ultrahigh vacuum surface setup for efficient testing of model and powder catalysts under clean gas-phase conditions

A small-volume reaction cell for catalytic or photocatalytic testing of solid materials at pressures up to 1000 Torr has been coupled to a surface-science setup used for standard sample preparation and characterization under ultrahigh vacuum (UHV). The reactor and sample holder designs allow easy sample transfer from/to the UHV chamber, and investigation of both planar and small amounts of powder catalysts under the same conditions. The sample is heated with an infrared laser beam and its temperature is measured with a compact pyrometer. Combined in a regulation loop, this system ensures fast and accurate temperature control as well as clean heating. The reaction products are automatically sampled and analyzed by mass spectrometry and/or gas chromatography (GC). Unlike previous systems, our GC apparatus does not use a recirculation loop and allows working in clean conditions at pressures as low as 1 Torr while detecting partial pressures smaller than 10{sup −4} Torr. The efficiency and versatility of the reactor are demonstrated in the study of two catalytic systems: butadiene hydrogenation on Pd(100) and CO oxidation over an AuRh/TiO{sub 2} powder catalyst.

36 MATERIALS SCIENCE↗

Development of the materials analysis and particle probe for Proto-MPEX

The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) is a linear plasma device being used in plasma source research and development (R&D) for the proposed MPEX. Once the R&D is completed, this device can also be used to perform plasma–material interaction studies. To perform these studies, a new materials analysis and particle probe (MAPP) has been constructed. The MAPP’s components are a sample holder and manipulator and a custom vacuum chamber with ports to facilitate surface chemistry diagnostics. The MAPP’s overall design enables rapid sample turnaround and in vacuo surface characterization. The surface analysis vacuum chamber has ports for x-ray photoelectron spectroscopy, thermal desorption spectroscopy, back-scatter ion scattering spectroscopy, forward-scatter ion scattering spectroscopy, and direct recoil spectroscopy. The sample manipulator and holder is a Lesker/UHV Multi-Centre Analytical Stage, which is used to place the samples in the exposure region of the Proto-MPEX or the analysis position in the MAPP vacuum chamber. The sample holder has a heating capability of up to 1200 °C for heated exposure and for desorption studies. In this work, we present the MAPP’s design and the first tungsten sample exposure with ex situ analysis that shows a surface deposition layer on the exposed target, highlighting the need for additional in situ measurements on the Proto-MPEX.

Beers, C. J. (ORCID:0000000150985459)↗

A magnetron sputtering system for the preparation of patterned thin films and in situ thin film electrical resistance measurements

We describe a versatile three gun magnetron sputtering system with a custom made sample holder for in situ electrical resistance measurements, both during film growth and ambient changes on film electrical properties. The sample holder allows for the preparation of patterned thin film structures, using up to five different shadow masks without breaking vacuum. We show how the system is used to monitor the electrical resistance of thin metallic films during growth and to study the thermodynamics of hydrogen uptake in metallic thin films. Furthermore, we demonstrate the growth of thin film capacitors, where patterned films are created using shadow masks.

36 MATERIALS SCIENCE↗

Balanced mechanical resonator for powder handling device

A system incorporating a balanced mechanical resonator and a method for vibration of a sample composed of granular material to generate motion of a powder sample inside the sample holder for obtaining improved analysis statistics, without imparting vibration to the sample holder support.

Sarrazin, Philippe C.↗

Development of a reaction cell for in-situ/operando studies of surface of a catalyst under a reaction condition and during catalysis

Tracking surface chemistry of a catalyst during catalysis is significant for fundamental understanding of catalytic performance of the catalyst since it allows for establishing an intrinsic correlation between surface chemistry of a catalyst at its working status and its corresponding catalytic performance. Ambient pressure X-ray photoelectron spectroscopy can be used for in-situ studies of surfaces of different materials or devices in a gas. To simulate the gaseous environment of a catalyst in a fixed-bed a flowing gaseous environment of reactants around the catalyst is necessary. Here, we report the development of a new flowing reaction cell for simulating in-situ study of a catalyst surface under a reaction condition in gas of one reactant or during catalysis in a mixture of reactants of a catalytic reaction. The homemade reaction cell is installed in a high vacuum (HV) or ultrahigh vacuum (UHV) environment of a chamber. The flowing gas in the reaction cell is separated from the HV or UHV environment through well sealings at three interfaces between the reaction cell and X-ray window, sample door and aperture of front cone of an energy analyzer. Catalyst in the cell is heated through infrared laser beam introduced through a fiber optics interfaced with the reaction cell through a homemade feedthrough. The highly localized heating on the sample holder and Au-passivated internal surface of the reaction cell effectively minimizes any unwanted reactions potentially catalyzed by the reaction cell. The incorporated laser heating allows a fast heating and a high thermal stability of the sample at a high temperature. With this cell, a catalyst at 800 °C in a flowing gas can be tracked readily.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanoconfinement platform for nanostructure quantification via grazing-transmission X-ray scattering

A nano-confinement platform that may allow improved quantification of the structural order of nanometer-scale systems. Sample-holder `chips` are designed for the GTSAXS experimental geometry. The platform involves fabricated nanostructured sample holders on and in one or more corners of a substrate support where the sample material of interest is positioned at the corner of the substrate support. In an embodiment, the substrate material making up the substrate support beneath the sample-holding area is removed. A scattering x-ray sample platform includes a substrate support arranged in a parallelepiped form, having a substantially flat base and a substantially flat top surface, the top surface being substantially parallel with the base, the parallelepiped having a plurality of corners. At least one corner of the substrate support has a sample holding area formed in the top surface of the substrate support and within a predetermined distance from the corner. The sample holding area includes a regular array of nano-wells formed in the top surface of the substrate support.

36 MATERIALS SCIENCE↗

A method for eliminating Faraday rotation in cryostat windows in longitudinal magneto-optical Kerr effect measurements

A solution to the problem of disturbing effect of the background Faraday rotation in the cryostat windows on longitudinal magneto-optical Kerr effect (LMOKE) measured under vacuum conditions and/or at low temperatures is proposed. The method for eliminating the influence of Faraday rotation in cryostat windows is based on special arrangement of additional mirrors placed on sample holder. In this arrangement, the orientation of the cryostat window is perpendicular to the light beam direction and parallel to an external magnetic field generated by the H-frame electromagnet. The operation of the LMOKE magnetometer with the special sample holder based on polarization modulation technique with a photo-elastic modulator is theoretically analyzed with the use of Jones matrices, and formulas for evaluating of the actual Kerr rotation and ellipticity of the sample are derived. The feasibility of the method and good performance of the magnetometer is experimentally demonstrated for the LMOKE effect measured in Fe/Au multilayer structures. The influence of imperfect alignment of the magnetometer setup on the Kerr angles, as derived theoretically through the analytic model and verified experimentally, is examined and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Shock compression of liquid helium and helium-hydrogen mixtures : development of a cryogenic capability for shock compression of liquid helium on Z, final report for LDRD Project 141536.

This final report on SNL/NM LDRD Project 141536 summarizes progress made toward the development of a cryogenic capability to generate liquid helium (LHe) samples for high accuracy equation-of-state (EOS) measurements on the Z current drive. Accurate data on He properties at Mbar pressures are critical to understanding giant planetary interiors and for validating first principles density functional simulations, but it is difficult to condense LHe samples at very low temperatures (<3.5 K) for experimental studies on gas guns, magnetic and explosive compression devices, and lasers. We have developed a conceptual design for a cryogenic LHe sample system to generate quiescent superfluid LHe samples at 1.5-1.8 K. This cryogenic system adapts the basic elements of a continuously operating, self-regulating {sup 4}He evaporation refrigerator to the constraints of shock compression experiments on Z. To minimize heat load, the sample holder is surrounded by a double layer of thermal radiation shields cooled with LHe to 5 K. Delivery of LHe to the pumped-He evaporator bath is controlled by a flow impedance. The LHe sample holder assembly features modular components and simplified fabrication techniques to reduce cost and complexity to levels required of an expendable device. Prototypes have been fabricated, assembled, and instrumented for initial testing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Overview of the Hybrid Illinois Device for Research and Applications Material Analysis Test-stand (HIDRA-MAT)

The Hybrid Illinois Device for Research and Applications (HIDRA) at the University of Illinois at Urbana-Champaign is a toroidal plasma device that enables fusion plasma-material interaction testing with both stellarator and tokamak plasmas. HIDRA’s long-pulse steady state stellarator plasmas provide a testbed for plasma facing component (PFC) plasma exposures. The HIDRA Material Analysis Test-stand (HIDRA-MAT) is a material characterization module attached to HIDRA that is being designed and fabricated to include thermal desorption spectroscopy and laser induced breakdown spectroscopy systems for in-vacuo PFC characterization. A specialized rotatable sample holder positions the sample for liquid metal droplet application from a liquid metal droplet injector on HIDRA-MAT. Early experiments look to investigate the effect liquid lithium has on porous tungsten samples’ retention of H, D, and He after plasma exposure. Preliminary results from a dual residual gas analyzer system show the ability to differentiate D2 and He in HIDRA-MAT. Finally, this work aims to advance the understanding of liquid metal PFCs and further the design and development of new fusion PFCs and technologies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cryogenic probe for low-noise, high-frequency electronic measurements

The design and performance of a low-noise, modular cryogenic probe, which is applicable to a wide range of measurements over a broad range of working frequencies, temperatures, and magnetic fields, is presented. The design of the probe facilitates the exchange of sample holders and sample-stage amplifiers, which, combined with its characteristic low transmission and reflection loss, make this design suitable for high precision or low sensitivity measurements. The specific example of measuring the shot noise of magnetic tunnel junctions is discussed. We highlight various design characteristics chosen specifically to expand the applicability of the probe to measurement techniques such as nuclear magnetic resonance.

47 OTHER INSTRUMENTATION↗

Robotic sample changers for macromolecular X-ray crystallography and biological small-angle X-ray scattering at the National Synchrotron Light Source II

In this work, we present two robotic sample changers integrated into the experimental stations for the macromolecular crystallography (MX) beamlines AMX and FMX, and the biological small-angle scattering (bioSAXS) beamline LiX. They enable fully automated unattended data collection and remote access to the beamlines. The system designs incorporate high-throughput, versatility, high-capacity, resource sharing and robustness. All systems are centered around a six-axis industrial robotic arm coupled with a force torque sensor and in-house end effectors (grippers). They have the same software architecture and the facility standard EPICS-based BEAST alarm system. The MX system is compatible with SPINE bases and Unipucks. It comprises a liquid nitrogen dewar holding 384 samples (24 Unipucks) and a stay-cold gripper, and utilizes machine vision software to track the sample during operations and to calculate the final mount position on the goniometer. The bioSAXS system has an in-house engineered sample storage unit that can hold up to 360 samples (20 sample holders) which keeps samples at a user-set temperature (277 K to 300 K). The MX systems were deployed in early 2017 and the bioSAXS system in early 2019.

36 MATERIALS SCIENCE↗

Synthesis and Observation of Emergent Phenomena in Epitaxial Heusler Compound Heterostructures

The proposal was on the synthesis and observation of emergent phenomena in epitaxial Heusler compound heterostructures. The large range of properties and number of Heusler compounds opens up a wide number of potential compounds that will exhibit emergent phenomena. The similarity, large range of relatively inexpensive, large area, high crystal quality, III-V bulk substrates, lattice parameters and the ability to tune the lattice parameters through ternary or quaternary III-V compound semiconductor epitaxial growth, makes III-V semiconductors an ideal choice for substrates for epitaxial growth of Heusler compounds. A number of half Heusler compounds have been predicted to exhibit band inversion, making them topological and are therefore expected to exhibit spin-momentum locked topological surface states with linear dispersion. Others are predicted to be semimetals with Weyl points and others semiconducting and magnetic. During the course of this grant, emphasis has been on investigating Heusler compounds with emergent phenomena and demonstrating the ability to tune their properties through alloying and strain. We have grown toplogical semimetal (PtLuSb, PtMnBi), Weyl (Co 2 MnAl, Co 2 TiGe), half metal (PtMnSb, Co 2 MnSi, Co 2 MnAl x Si 1-x , Co2FeAl), and semiconducting (CoTiSb, NiTiSn) and tuned their properties through alloying and epitaxial strain. We also investigated the closely related materials of rare-earth monopnictide, some of which have also been predicted to be topological. During the attempts to grow the PtMnBi, it was discovered that Bi, another predicted topological material when ultrathin, could be grown epitaxially on InSb, results for which are also reported here. The main focus for this effort has been on using variable photon energy and spin-dependent angle resolved photoemission (ARPES) to determine bulk band structure and surface states of pristine epitaxial films grown on III-V semiconductor and MgO substrates and correlate results with theory and transport measurements. Theory has been critical to interpretation of experimental results and has been essential in guiding experiments. The research benefited from several strong collaborations between the PIs and the beamline scientists at the Advanced Light Source at Lawrence Berkeley Laboratory, the Stanford Linear Accelerator Center (SLAC) at Stanford and at the Max Lab at Lund University in Sweden. The strong experiment - theory collaboration between the PI’s groups, the Palmstrøm group at UCSB and the Janotti group at the University of Delaware, has been critical for interpreting the experimental ARPES and magnetotransport measurements results and making predictions to guide experiments. Weekly interactive Zoom meetings made this work well. A collaboration between the Palmstrøm group and Dr. Alexei Fedorov at the Advanced Light Source (ALS) resulted in significant modifications to his end chamber to accommodate the vacuum suitcase that was designed and constructed in the Palmstrøm group at UCSB. In collaboration with beamline scientists, Drs. Makoto Hashimoto and Donghui Lu at SLAC, Palmstrøm made modifications to the vacuum suitcase and developed special sample holders that allowed samples to be grown in the Palmstrøm MBE systems at UCSB and transported in the UHV vacuum suitcase to SLAC for ARPES measurements. The development of the vacuum suitcase was essential for this grant as it has allowed variable photon energies to be used to identify surface versus bulk states on samples that could not be capped and decapped using As- or Sb-capping layers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗