Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAFETY DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Fusion energy technology and design-specific safety considerations

Design of commercial fusion energy technology must be done in a manner safe to the general public. This presentation is intended to cover the major non-radiological categories which must be considered for adequate safety of fusion devices.

70 - PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fusion energy technology and design-specific safety considerations

Design of commercial fusion energy technology must be done in a manner safe to the general public. This presentation is intended to cover the major non-radiological categories which must be considered for adequate safety of fusion devices.

70 - PLASMA PHYSICS AND FUSION TECHNOLOGY↗

2D surface temperature measurement of plasma facing components with modulated active pyrometry

In nuclear fusion devices, such as Tore Supra, the plasma facing components (PFC) are in carbon. Such components are exposed to very high heat flux and the surface temperature measurement is mandatory for the safety of the device and also for efficient plasma scenario development. Besides this measurement is essential to evaluate these heat fluxes for a better knowledge of the physics of plasma-wall interaction, it is also required to monitor the fatigue of PFCs. Infrared system (IR) is used to manage to measure surface temperature in real time. For carbon PFCs, the emissivity is high and known (ε ~ 0.8), therefore the contribution of the reflected flux from environment and collected by the IR cameras can be neglected. However, the future tokamaks such as WEST and ITER will be equipped with PFCs in metal (W and Be/W, respectively) with low and variable emissivities (ε ~ 0.1–0.4). Consequently, the reflected flux will contribute significantly in the collected flux by IR camera. The modulated active pyrometry, using a bicolor camera, proposed in this paper allows a 2D surface temperature measurement independently of the reflected fluxes and the emissivity. Experimental results with Tungsten sample are reported and compared with simultaneous measurement performed with classical pyrometry (monochromatic and bichromatic) with and without reflective flux demonstrating the efficiency of this method for surface temperature measurement independently of the reflected flux and the emissivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Grazing incidence angle based sensing approach integrated with fiber-optic Fourier transform infrared (FO-FTIR) spectroscopy for remote and label-free detection of medical device contaminations

Contamination of medical devices has become a critical and prevalent public health safety concern since medical devices are being increasingly used in clinical practices for diagnostics, therapeutics and medical implants. The development of effective sensing methods for real-time detection of pathogenic contamination is needed to prevent and reduce the spread of infections to patients and the healthcare community. In this study, a hollow-core fiber-optic Fourier transform infrared spectroscopy methodology employing a grazing incidence angle based sensing approach (FO-FTIR-GIA) was developed for detection of various biochemical contaminants on medical device surfaces. We demonstrated the sensitivity of FO-FTIR-GIA sensing approach for non-contact and label-free detection of contaminants such as lipopolysaccharide from various surface materials relevant to medical device. The proposed sensing system can detect at a minimum loading concentration of approximately 0.7 μg/cm{sup 2}. The FO-FTIR-GIA has the potential for the detection of unwanted pathogen in real time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Implementation of wireless technologies in nuclear power plants' electromagnetic environment using cognitive radio system - 153

Wireless technologies have increased efficiency in many industrial settings across the world by enabling a mobile workforce and improving communications. Unfortunately, the nuclear power industry has been slow to adopt wireless technology as a result of safety, security, and reliability concerns expressed by regulators and others. A Research and Development (R and D) effort is currently being conducted to address two significant technical concerns for the introduction of wireless technology in nuclear power plants, which are electromagnetic compatibility (EMC) and wireless coexistence. Most equipment in nuclear power plants has never been tested for vulnerability to wireless transmission. As such, the impact of modern wireless devices on nuclear safety and plant reliability is not understood. Existing guidance from the Nuclear Regulatory Commission (NRC) and Electric Power Research Institute (EPRI) rely on the use of exclusion zones to protect plant equipment, which can result in exclusion zones of up to eight feet for some tablet devices rendering them ineffective for the mobile workforce. Another unknown is how different wireless devices will operate in close proximity to one another in the harsh electromagnetic environment of a nuclear power plant. These issues are being addressed through development of a cognitive radio system that has the ability to generate and output multiple wireless signals such as Wi-Fi, Bluetooth, and cellular communications at varying power levels and frequencies. The cognitive radio system is a modular system that can test nuclear plant equipment located in training areas, simulators, and the actual plant environment. In addition to using the system for testing plant equipment to wireless signals and EMC standards, the system can also monitor the radio spectrum for usage in other plant focuses such as cyber security. The R and D work will provide the objective guidance for the nuclear industry in the two areas mentioned and will develop a cognitive radio system for in-plant EMC and coexistence testing. The system will assist in the seamless use of wireless technology in nuclear power plants while greatly reducing the risks wireless signals may introduce. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fueling the Future: The Emergence of Self-Powered Enzymatic Biofuel Cell Biosensors

Self-powered biosensors are innovative devices that can detect and analyze biological or chemical substances without the need for an external power source. These biosensors can convert energy from the surrounding environment or the analyte itself into electrical signals for sensing and data transmission. The self-powered nature of these biosensors offers several advantages, such as portability, autonomy, and reduced waste generation from disposable batteries. They find applications in various fields, including healthcare, environmental monitoring, food safety, and wearable devices. While self-powered biosensors are a promising technology, there are still challenges to address, such as improving energy efficiency, sensitivity, and stability to make them more practical and widely adopted. This review article focuses on exploring the evolving trends in self-powered biosensor design, outlining potential advantages and limitations. With a focal point on enzymatic biofuel cell power generation, this article describes various sensing mechanisms that employ the analyte as substrate or fuel for the biocatalyst’s ability to generate current. Technical aspects of biofuel cells are also examined. Research and development in the field of self-powered biosensors is ongoing, and this review describes promising areas for further exploration within the field, identifying underexplored areas that could benefit from further investigation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Defining and Characterizing Methods, Tools, and Computing Resources to Support Pseudo Exhaustive Testability of Software Based I&C Devices

Under the Department of Energy’s Light Water Reactor Sustainability Program, within the Plant Modernization research pathway, the Digital I&C Qualification Project is identifying new methods that would be beneficial in qualifying digital I&C systems and devices for safety-related usage. One such method that would be useful in qualifying field components such as sensors and actuators is the concept of testability. The Nuclear Regulatory Commission (NRC) considers testability to be one of two design attributes sufficient to eliminate consideration of software-based or software logic-based common cause failure (the other being diversity). The NRC defines acceptable “testability” as follows: Testability – A system is sufficiently simple such that every possible combination of inputs and every possible sequence of device states are tested and all outputs are verified for every case (100% tested). [NUREG 0800, Chapter 7, Branch Technical Position (BTP) 7-19] This qualification method has never proven to be practical in view of the very large number of combinations of inputs and sequences of device states for a typical I&C device. However, many of these combinations are not unique in the sense that they represent the same state space or in that that they represent state space that would not affect the critical design basis functions of the device. Therefore, the state space of interest might possibly be reduced to a manageable dimension through such analysis. This project focuses on a representative I&C device similar in design, function, and complexity to the types of devices that would likely be deployed in nuclear power plants as digital or software based sensors and actuators (e.g. Smart Sensors). Analysis will be conducted to determine the feasibility of testing this device in a manner consistent with the NRC definition. This report describes acceptable test methods, needed tools (existing or new), and computing resources, all based on engineering and computer science principles. This information will then be used in a later phase of this project to develop a test specification for I&C device testability that can be used in a future phase of this project to demonstrate digital qualification with respect to common cause failure. Following that, testing will be conducted and the results analyzed to determine if the methods employed are sufficient to eliminate consideration of software common cause failure in accordance with the concept of testability.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

REALIZATION OF A AUTOMATED T-WAY COMBINATORIAL TESTING APPROACH FOR A SOFTWARE BASED EMBEDDED DIGITAL DEVICE

Under the Department of Energy’s Light Water Reactor Sustainability Program, within the Plant Modernization research pathway, the Digital I&C Qualification Project is identifying new methods that would be beneficial in qualifying digital I&C systems and devices for safety-related usage. One such method that would be useful in qualifying field components such as sensors and actuators is the concept of testability. The Nuclear Regulatory Commission (NRC) considers testability to be one of two design attributes sufficient to eliminate consideration of software-based or software logic-based common cause failure (the other being diversity). The NRC defines acceptable “testability” as follows: Testability – A system is sufficiently simple such that every possible combination of inputs and every possible sequence of device states are tested and all outputs are verified for every case (100% tested). [NUREG 0800, Chapter 7, Branch Technical Position (BTP) 7-19] This qualification method has never proven to be practical in view of the very large number of combinations of inputs and sequences of device states for a typical I&C device. However, many of these combinations are not unique in the sense that they represent the same state space or in that that they represent state space that would not affect the critical design basis functions of the device. Therefore, the state space of interest might possibly be reduced to a manageable dimension through such analysis. This project will focus on a representative I&C device similar in design, function, and complexity to the types of devices that would likely be deployed in nuclear power plants as digital or software based sensors and actuators (e.g. Smart Sensors). Analysis will be conducted to determine the feasibility of testing this device in a manner consistent with the NRC definition. This report describes the development of test process for Bounded Exhaustive Testing with respect to Combinatorial Test (CT) methods. The report describes the candidate Device Under Test SW – the VCU smart sensor, conceptual experimental methods for stated test objectives, description of the process, tools, resources, and computing. This information will be used to fully develop a detailed test plan (based on statistical measure needs) and test environment for conducting an I&C device testability demonstration study. The future planed experimental study of this project is to demonstrate digital qualification via Bounded Exhaustive Testability with respect to Common Cause Failure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design of High Power Density 100 kW Surface Permanent Magnet Machine with No Heavy Rare Earth Material Using Current Source Inverter for Traction Application

Surface permanent magnet (SPM) machines are appealing candidates for traction applications because of high power density and high efficiency. Rare-earth magnets deliver high performance but raise concerns about material supply dependability, particularly if they use heavy rare-earth materials. This paper presents the design of a high-performance SPM machine without any heavy rare-earth material that is optimized specifically for a current-source inverter (CSI) traction drive. This machine is designed for a constant-power speed ratio (CPSR) of 3. A genetic algorithm has been performed to achieve a target of 50 kW/L active power density at speeds up to 20,000 rpm. Operation at a peak line-to-line voltage of 800 V can be achieved using 1200 V power devices with a safety margin. The predicted electromagnetic and rotor structural performance characteristics are presented using both analytical and finite element analysis (FEA) results.

(CPSR)↗

A Comprehensive Assessment Tool for Low-TRL Current Energy Converters

Along with a market-competitive levelized cost of energy, a current energy converter technology strongly benefits from an extensive consideration of socioeconomic, environmental, and regulatory factors early in the design process. As part of a technology performance level assessment, a series of assessment questions and guidance are developed and presented to evaluate an early-stage current energy technology on holistic criteria considering the entire device lifecycle. The assessment represents an accumulation of industry and research experience to date and relies on regular updates to ensure alignment with industry best-practices, regulatory requirements, and up-to-date technical understanding. A cradle-to-grave (materials, manufacturing, installation and deployment, operations and maintenance, and end-of-life) assessment of capabilities and functional requirements (i.e., high, medium, and low) performance criteria for current energy converters deployed in tidal, ocean current, and/or river applications. Key considerations related to manufacturing and installation include supply chain robustness, manufacturability and related job creation in the end-user and/or adjacent communities, and the time-to-repayment of the embodied energy debt. During deployment and maintenance operations, the safety of the device and subsystems during disconnect or grid failure, the difficulty and frequency of offshore heavy-lift activities, the avoidance or mitigation of area-use conflicts, the sea-states and weather conditions that permit maintenance access, and the availability of contingency plans (should conditions change unexpectedly) are a portion of the considered assessment criteria. Results include the potential impact of early-stage design decisions on the socioeconomic, environmental, and regulatory performance of a technology that allows developers to increase the product value and probability of success, and minimize costly late-stage design iterations through early and broad consideration of factors affecting overall performance and acceptability.

life cycle analysis↗

A Comprehensive Assessment Tool for Low-TRL Current Energy Converters: Preprint

Along with a market-competitive levelized cost of energy, a current energy converter technology strongly benefits from an extensive consideration of socioeconomic, environmental, and regulatory factors early in the design process. As part of a technology performance level assessment, a series of assessment questions and guidance are developed and presented to evaluate an early-stage current energy technology on holistic criteria considering the entire device lifecycle. The assessment represents an accumulation of industry and research experience to date and relies on regular updates to ensure alignment with industry best-practices, regulatory requirements, and up-to-date technical understanding. A cradle-to-grave (materials, manufacturing, installation and deployment, operations and maintenance, and end-of-life) assessment of capabilities and functional requirements for tidal, river, and ocean current technologies has been completed. This work presents the evaluation questions and qualitative performance criteria for current energy converters deployed in tidal, ocean current, and/or river applications. Key considerations related to manufacturing and installation include supply chain robustness, manufacturability and related job creation in the end-user and/or adjacent communities, and the time-to-repayment of the embodied energy debt. During deployment and maintenance operations, the safety of the device and subsystems during disconnect or grid failure, the difficulty and frequency of offshore heavy-lift activities, the avoidance or mitigation of area use conflicts, the sea-states and weather conditions that permit maintenance access, and the availability of contingency plans (should conditions change unexpectedly) are a portion of the considered assessment criteria. Results include the potential impact of early-stage design decisions on the socioeconomic, environmental, and regulatory performance of a technology that allows developers to increase the product value and probability of success, and minimize costly late-stage design iterations through early and broad consideration of factors affecting overall performance and acceptability.

industry support↗

A Comprehensive Assessment Tool for Low-TRL Current Energy Converters

Along with a market-competitive levelized cost of energy, a current energy converter technology strongly benefits from an extensive consideration of socioeconomic, environmental, and regulatory factors early in the design process. As part of a technology performance level assessment, a series of assessment questions and guidance are developed and presented to evaluate an early-stage current energy technology on holistic criteria considering the entire device lifecycle. The assessment represents an accumulation of industry and research experience to date and relies on regular updates to ensure alignment with industry best-practices, regulatory requirements, and up-to-date technical understanding. A cradle-to-grave (materials, manufacturing, installation and deployment, operations and maintenance, and end-of-life) assessment of capabilities and functional requirements for tidal, river, and ocean current technologies has been completed. This work presents the evaluation questions and qualitative performance criteria for current energy converters deployed in tidal, ocean current, and/or river applications. Key considerations related to manufacturing and installation include supply chain robustness, manufacturability and related job creation in the end-user and/or adjacent communities, and the time-to-repayment of the embodied energy debt. During deployment and maintenance operations, the safety of the device and subsystems during disconnect or grid failure, the difficulty and frequency of offshore heavy-lift activities, the avoidance or mitigation of area use conflicts, the sea-states and weather conditions that permit maintenance access, and the availability of contingency plans (should conditions change unexpectedly) are a portion of the considered assessment criteria. Results include the potential impact of early-stage design decisions on the socioeconomic, environmental, and regulatory performance of a technology that allows developers to increase the product value and probability of success, and minimize costly late-stage design iterations through early and broad consideration of factors affecting overall performance and acceptability.

converter↗

Neutron calorimeter development at fission and fusion pulsed neutron sources

A neutron calorimeter fielded in pulsed neutron irradiation experiments at the National Ignition Facility (NIF) and White Sands Missile Range Fast Burst Reactor (WSMR FBR) is described, and results are provided and discussed. The calorimeter is modular in design to allow fielding of various neutron absorber materials and thicknesses, as well as use at both fission and fusion sources, all of which has been done. Neutron calorimeters designed for fission sources have been fielded at fusion sources as well, but these instances are not documented in available literature—making this work novel. The functional calorimeter consists of a neutron absorber and two sheathed, grounded thermocouples secured within a subassembly made of thermally insulating materials. This subassembly is placed into a sealed vessel for material and facility safety considerations. The device was fielded at NIF in four polar-direct-drive exploding pusher shots and eleven WSMR FBR pulses. Calorimeter data from NIF experiments show a discernable thermal response accredited to neutron heating within the first 10 s, but the data are dominated by noise from ambient X-ray heating after time = 10 s post-pulse. This response is highly consistent between shots and linearly related to incident neutron fluence and neutron absorber thickness. A temperature rise of 1.1E-2 K/(10 13 neutrons/cm 2 ) per millimeter of absorber thickness was determined for both 0.4 mm and 1 mm thick depleted uranium absorbers with linear best fit R 2 of 0.97 and 0.98 for each thickness and y-axis offsets of 8.8E-3 and 1.3E-2, respectively. WSMR FBR experiment data show a temperature rise of 6.2E-2 K/(10 13 neutrons/cm 2 ) with linear best fit R 2 of 0.14 and y-axis offset of 7.6E-3 for a calorimeter with a 1 mm thick enriched boron carbide ( 10 B 4 C) absorber, though it must be noted that device-to-device variability is significant at both facilities. So these data are also affected by noise on a similar timescale as at NIF, though the noise is significantly lesser in magnitude but oscillatory.

42 ENGINEERING↗

A Novel Model of Thyristor in Reverse Recovery Process for Current Interruption Test of HVDC Circuit Breakers

The high voltage thyristor is widely used in high voltage DC (HVDC) grids due to its large current capability. Recently, the high voltage thyristor is implemented to produce a high current in the HVDC circuit breaker (CB) testing process. Unfortunately, the reverse recovery process (RRP) of a thyristor could induce significant turn-off overvoltage and power losses, jeopardizing the safety of the devices. The existing models of a thyristor cannot describe such hard-switching transient accurately. Therefore, this paper divides this process into four stages based on the physical mechanism and proposes a novel cosine exponential (CE), simulating the voltage and current of the thyristor with analytical equations, which are derived from the equivalent circuit. Moreover, the extraction procedure of the proposed model is illustrated in this paper. Finally, we develop an HVDC CB test platform to validate the proposed model. Experimental results show that the proposed CE model can accurately predict the overvoltage with a relative error of less than 8% at various current varying rates.

Dongye, Zhonghao↗

High Temperature Irradiation Resistant Thermocouple (HTIR-TC)

INL researchers have created a new thermocouple that can resist high temperature and radiation. This device will improve safety and reduce costs associated with unit failures. Learn more about INL research at http://www.facebook.com/idahonationallaboratory

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Overview of the Salt at Wall Thermal Exchanges (SWATH) Experiment

Molten Salt Reactors have attracted increased attention in recent years because of the design and safety possibilities offered by the use of a liquid fuel. The European project SAMOFAR1 (2015-2019) is currently coordinating the research efforts on the Molten Fast Salt Reactor (MSFR) concept in Europe. The MSFR is a fast-spectrum breeder reactor with a large negative power coefficient that can be operated in a Thorium fuel cycle. The fast spectrum allows the reduction of the reprocessing requirements and a better reactor breeding ratio. Other advantages of the MSFR design are the possibility for actinide burning and extending fuel resources, on-line fuel loading and reprocessing and the use of novel passive safety systems such as the fuel salt draining system. The reference MSFR concept is a 3000 MW(th) reactor with three different circuits: the fuel circuit, the intermediate circuit and the power conversion system. The main components of the fuel circuit are the fuel salt which serves as fuel and coolant, the core cavity, the inlet and outlet pipes, the gas injection system (not shown in the figure), the salt-bubble separators, the fuel heat exchangers and the pumps. A lithium fluoride salt has been selected as the fuel matrix. The initial composition (non-irradiated) of the MSFR fuel salt is a mixture of a lithium fluoride, thorium fluoride salts and actinides fluoride (LiF-ThF{sub 4}-{sup 233}UF{sub 4} or LiF-ThF{sub 4}- {sup enr}UF{sub 4}-(Pu-MA)F{sub 3}), with the proportion of LiF fixed at about Development of accurate numerical models for the MSFR can only be accomplished by the use of a multiphysics approach which allows taking into account the coupling between relevant neutronics, thermal hydraulics and thermomechanics phenomena. As it is discussed in the next section, such a reactor model requires further progress on the knowledge of molten salt thermal hydraulics, in particular regarding the accuracy of the fuel salt Computational Fluid Dynamics (CFD) models. The Salt at Wall: Thermal Exchanges (SWATH) experiment is being designed to contribute to this particular point. SWATH is one of the experimental activities of the European H2020 SAMOFAR project and includes both experimental and numerical developments. The main objectives of SWATH are to: (i) Improve molten salt numerical models used for design and safety studies and (ii) Demonstrate the working principles of the cold plug device. The cold plug device is a key safety component of the salt draining system of the MSFR. The cold plug is intended to passively melt during accidental conditions thus allowing the flow of the nuclear fuel from the core cavity to the fuel salt draining tanks by gravity forces. The fuel salt draining tanks are designed to ensure that adequate margins are obtained regarding the fuel cooling capabilities and the reactivity control. The next sections provide an overview of the current challenges in molten salt thermal hydraulics modeling and the SWATH experiment design. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Note: Electrostatic detection of stainless steel dust particles for fusion applications

Dust accumulation inside next-step fusion devices poses a significant safety concern and dust diagnostics will be needed to assure safe operations. An electrostatic dust detection device has been successfully demonstrated in the National Spherical Torus Experiment, Tore Supra, and the Large Helical Device, and the detector's response to carbon particles was previously characterized in laboratory experiments. This paper presents laboratory results showing that detection of stainless steel particles at levels as low as several μg/cm{sup 2} is also possible.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An overview of craniospinal axis fields and field matching

Many methods are implemented for craniospinal axis (CSA) radiation treatment (RT). This paper’s goal is to define correctly matched CSA RT fields. Overlap or a space between matched RT fields can create variances of dose and the possibility of negative side effects or disease recurrence, respectively. An accurate CSA RT match procedure is created with localization markers, immobilization devices, equations, feathered matches, safety gap, and portal imaging. A CS match angle is predetermined to optimize patient position before immobilization device fabrication. Various central axis (CA) placements within the brain and spine fields that effect gantry, table, and collimator rotation are described. An overview of the methods used to create CSA RT fields and matches is presented for optimal CSA RT implementation. In addition, to the author’s knowledge, this is the first time that a prone CSA RT with anesthesia has been described.

61 RADIATION PROTECTION AND DOSIMETRY↗