Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Rooftop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Methodology for Estimating Solar Potential on Multiple Building Rooftops for Photovoltaic Systems

In this paper, a methodology for estimating solar potential on multiple building rooftops is presented. The objective of this methodology is to estimate the daily or monthly solar radiation potential on individual buildings in a city/region using Light Detection and Ranging (LiDAR) data and a geographic information system (GIS) approach. Conceptually, the methodology is based on the upward-looking hemispherical viewshed algorithm, but applied using an area-based modeling approach. The methodology considers input parameters, such as surface orientation, shadowing effect, elevation, and atmospheric conditions, that influence solar intensity on the earth s surface. The methodology has been implemented for some 212,000 buildings in Knox County, Tennessee, USA. Based on the results obtained, the methodology seems to be adequate for estimating solar radiation on multiple building rooftops. The use of LiDAR data improves the radiation potential estimates in terms of the model predictive error and the spatial pattern of the model outputs. This methodology could help cities/regions interested in sustainable projects to quickly identify buildings with higher potentials for roof-mounted photovoltaic systems.

14 SOLAR ENERGY↗

Modeling the potential effects of rooftop solar on household energy burden in the United States

Policymakers at the federal and state level have begun to incorporate energy burden into equity goals and program evaluations, aiming to reduce energy burden below a high level of 6% for lower income households in the United States. Pairing an empirical household-level dataset spanning United States geographies together with modeled hourly energy demand curves, we show that rooftop solar reduces energy burden across a majority of adopters during our study period from a median of 3.3% to 2.6%. For low- and moderate-income adopters (at or below 80% and 120% of area median income, respectively), solar reduces median 2021 energy burden from 7.7% to 6.2%, and 4.1% to 3.3%, respectively. Importantly, solar reduces the rate of high or severe energy burden from 67% of all low-income households before adoption to 52% of households following adoption, and correspondingly from 21% to 13% for moderate-income households. Here, we show rooftop solar can support policy goals to reduce energy burden along with strategies such as weatherization and bill assistance.

14 SOLAR ENERGY↗

The impact of policies and business models on income equity in rooftop solar adoption

Low- and moderate-income (LMI) households are less likely to adopt rooftop solar photovoltaics (PVs) than higher-income households in the United States. As the existing literature has shown, this dynamic can decelerate rooftop PV deployment and has potential energy justice implications, in light of the cost-shifting between PV and non-PV households that can occur under typical rate structures and incentive programmes. Here we show that some state policy interventions and business models have expanded PV adoption among LMI households. Additionally, we find evidence that LMI-specific financial incentives, PV leasing and property-assessed financing have increased the diffusion of PV adoption among LMI households in existing markets and have driven more installations into previously underserved low-income communities. By shifting deployment patterns, we posit that these interventions could catalyse peer effects to increase PV adoption in low-income communities even among households that do not directly benefit from the interventions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analysis of the Value Proposition of High-Efficiency, Multijunction Solar Modules for Residential Rooftop Installations

Utilizing detailed bottom-up models, we analyze the potential markets for high-efficiency photovoltaic modules in the United States. We first estimate the fraction of area-constrained residential rooftops that could benefit from increasing the availability of high-efficiency systems. We then model the impact of efficiency on installed system costs in these area-constrained scenarios. Finally, we explore the value proposition of high-efficiency, fixed-tilt micro-concentrator photovoltaic modules in a series of case studies of residential customers, modeling the levelized cost of energy, payback period, and annual bill savings. We find that efficiency can provide significant savings in installed system cost and improve value to the solar system owner. The improvement in value depends on location and the size of the rooftop, as well as the ability of a given technology to collect diffuse light and achieve low module costs.

14 SOLAR ENERGY↗

Advanced Rooftop Control (ARC) Retrofit: Field-Test Results

The multi-year research study was initiated to find solutions to improve packaged equipment operating efficiency in the field. Pacific Northwest National Laboratory (PNNL), with funding from the U.S. Department of Energy’s (DOE’s) Building Technologies Office (BTO) and Bonneville Power Administration (BPA) conducted this research, development and demonstration (RD&D) study. Packaged equipment with constant speed supply fans is designed to provide ventilation at the design rate at all times when the fan is operating as required by building code. Although there are a number of hours during the day when a building may not be fully occupied or the need for ventilation is lower than designed, the ventilation rate cannot be adjusted easily with a constant speed fan. Therefore, modulating the supply fan in conjunction with demand controlled ventilation (DCV) will not only reduce the coil energy but also reduce the fan energy. The objective of this multi-year research, development and demonstration project was to determine the magnitude of energy savings achievable by retrofitting existing packaged rooftop air conditioners with advanced control strategies not ordinarily used for packaged units. First, through detailed simulation analysis, it was shown that significant energy (between 24% and 35%) and cost savings (38%) from fan, cooling and heating energy consumption could be realized when packaged air conditioning units with gas furnaces are retrofitted with advanced control packages (combining multi-speed fan control, integrated economizer controls and DCV). The simulation analysis also showed significant savings for heat pumps (between 20% and 60%). The simulation analysis was followed by an extensive field test of a retrofittable advanced rooftop unit (RTU) controller.

Katipamula, Srinivas↗

Structural Code Considerations for Solar Rooftop Installations

Residential rooftop solar panel installations are limited in part by the high cost of structural related code requirements for field installation. Permitting solar installations is difficult because there is a belief among residential permitting authorities that typical residential rooftops may be structurally inadequate to support the additional load associated with a photovoltaic (PV) solar installation. Typical engineering methods utilized to calculate stresses on a roof structure involve simplifying assumptions that render a complex non-linear structure to a basic determinate beam. This method of analysis neglects the composite action of the entire roof structure, yielding a conservative analysis based on a rafter or top chord of a truss. Consequently, the analysis can result in an overly conservative structural analysis. A literature review was conducted to gain a better understanding of the conservative nature of the regulations and codes governing residential construction and the associated structural system calculations.

Dwyer, Stephen F.↗

Physical Sciences Laboratory 1 Rooftop Stack Mixing Study

To address concerns about worker exposures on the Physical Science Laboratory (PSL) rooftop, a tracer study was conducted to measure gaseous tracer concentrations downwind of six stacks on the southern half of the PSL building (PSL-1). These concerns were raised, in part, due to the non-standard configuration of the stacks on this building. Five of the six stacks were only about 8 feet tall, with one shorter stack that was essentially level with the roof deck. These stacks were reconfigured in August 2016, and these exhaust points on PSL-1 are now 18 feet tall. This report describes the objectives of the tracer tests performed on PSL-1, provides an overview of how the tests were executed, and presents results of the tests. The tests on the PSL rooftop were a follow-on project from a similar study performed on the LSL-II ventilation exhaust (Flaherty and Antonio, 2016).

54 ENVIRONMENTAL SCIENCES↗

Analyzing the Energy Performance, Wind Loading, and Costs of Photovoltaic Slat Modules on Commercial Rooftops

NREL studied a new type of photovoltaic (PV) module configuration wherein multiple narrow, tilted slats are mounted in a single frame. Each slat of the PV slat module contains a single row of cells and is made using ordinary crystalline silicon PV module materials and processes, including a glass front sheet and weatherproof polymer encapsulation. Compared to a conventional ballasted system, a system using slat modules offer higher energy production and lower weight at lower LCOE. The key benefits of slat modules are reduced wind loading, improved capacity factor and reduced installation cost. First, the individual slats allow air to flow through, which reduce wind loading. Using PV performance modeling software, we compared the performance of an optimized installation of slats modules to a typical installation of conventional modules in a ballasted rack mounting system. Based on the results of the performance modeling two different row tilt and spacing were tested in a wind tunnel. Scaled models of the PV Slat modules were wind tunnel tested to quantify the wind loading of a slat module system on a commercial rooftop, comparing the results to conventional ballasted rack mounted PV modules. Some commercial roofs do not have sufficient reserve dead load capacity to accommodate a ballasted system. A reduced ballast system design could make PV system installation on these roofs feasible for the first time without accepting the disadvantages of penetrating mounts. Finally, technoeconomic analysis was conducted to enable an economic comparison between a conventional commercial rooftop system and a reduced-ballast slat module installation.

14 SOLAR ENERGY↗

Water Footprint of European Rooftop Photovoltaic Electricity based on Regionalised Life Cycle Inventories

The water use of photovoltaic (PV) electricity has been investigated in very few studies so far, which may be due to the low water demand of PV systems during operation. In this study, the water consumption and water withdrawal of electricity generated by PV systems were assessed by considering all life cycle stages and by taking account of country-level regional differences in water availability. The life cycle inventories of the manufacture of monocrystalline silicon (mono-Si) and cadmium telluride (CdTe) PV modules are based on data collected between 2010 and 2013 and take account of the shares of different countries in total global production. The water use in the life cycle inventories of European rooftop PV systems and conventional electricity generation technologies was regionalised to the country or region (such as continents, political or geographic entities of several countries) level and complemented by the share of water lost by evaporation. The AWARE (Available WAter REmaining) method was used to assess the water stress impact caused by water consumption and water withdrawal of electricity generation by European rooftop PV systems as well as by reservoir hydroelectric power plants and large-scale hard coal and nuclear power plants in Europe. The functional unit of this analysis is 1 kWh of alternating current (AC) electricity (at busbar). The life cycle inventories were linked to KBOB (Coordination Group for Construction and Property Services) life cycle inventory data DQRv2:2016, which are based on ecoinvent data v2.2 and contain updated life cycle inventory data in relevant economic sectors. This study was financed by the Swiss Federal Office of Energy (SFOE) and carried out in the framework of the Task 12 of the Photovoltaic Power Systems Programme (PVPS) of the International Energy Agency (IEA).

14 SOLAR ENERGY↗

ComStock Measure Documentation: Thermostat and Lighting Control for Load Shedding + Photovoltaics With 40% Rooftop Coverage

This report describes the modeling methodology for an upgrade package of two end-use savings shape measures - Thermostat Control for Load Shedding and Lighting Control for Load Shedding - and briefly introduces key results. The package combines thermostat control for load shedding, lighting control for load shedding, and PV with 40% rooftop coverage measures to reduce the net building load during the building's electricity peak window every weekday. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start and end times of the predicted peak window, and then relaxes the thermostat setpoints and dims the lighting level from the original schedules during the peak window to reduce the peak demand, while applying the fixed rooftop PV application for onsite electricity generation. The measure is applicable to (large, medium and small) offices, warehouses, and primary and secondary schools, which correspond to approximately 68% of the stock floor area of commercial buildings in ComStock analysis. The measure demonstrates 5%-15% daily peak demand reduction performance for applicable buildings, and around 1% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

14 SOLAR ENERGY↗

Development of a Hydronic Rooftop Unit-HyPak-MA

The majority of U.S. commercial floor space is cooled by rooftop HVAC units (RTUs). RTU popularity derives chiefly from their low initial cost and relative ease of service access without disturbing building occupants. Unfortunately, current RTUs are inherently inefficient due to a combination of characteristics that unnecessarily increase cooling loads and energy use. 36% percent of annual U.S. energy, and two-thirds of electricity, is consumed in and by buildings. Commercial buildings consume approximately 4.2 quads of energy each year at a cost of $230 billion per year, with HVAC equipment consuming 1.2 quads of electricity. More than half of all U.S. commercial floor space is cooled by packaged HVAC units, most of which are rooftop units (RTUs). Inefficient RTUs create an estimated 3.5% of U.S. CO{sub 2} emissions, thus contributing significantly to global warming5. Also, RTUs often fail to maintain adequate ventilation air and air filtration, reducing indoor air quality. This is the second HyPak project to be supported by DOE through NETL. The prior project, referred to as HyPak-1 in this report, had two rounds of prototype fabrication and testing as well as computer modeling and market research. The HyPak-1 prototypes demonstrated the high performance capabilities of the HyPak concept, but made it clear that further development was required to reduce heat exchanger cost and improve system reliability before HyPak commercialization can commence. The HyPak-1 prototypes were limited to about 25% ventilation air fraction, limiting performance and marketability. The current project is intended to develop a 'mixed-air' product that is capable of full 0-100% modulation in ventilation air fraction, hence it was referred to as HyPak-MA in the proposal. (For simplicity, the -MA has been dropped when referencing the current project.) The objective of the HyPak Project is to design, develop and test a hydronic RTU that provides a quantum improvement over conventional RTU performance. Our proposal targeted 60% and 50% reduction in electrical energy use by the HyPak RTU for dry and humid climates, respectively, when compared with a conventional unit, and reduction in peak energy consumption of 50% and 33% respectively. In addition to performance targets, our goal is to develop a production-ready design with durability, reliability and maintainability similar to air-cooled packaged equipment, and that can be commercialized immediately following the conclusion of this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dataset for: Rooftop solar and energy storage programs can remediate energy-limiting behaviors of energy insecure households

Energy insecurity affects most low-income households in the United States. Energy insecurity, which is characterized by a household’s inability to afford their energy needs, often leads to risky choices, causing other forms of insecurity including food and health. Although there are government programs designed to provide relief to low-income households that face energy insecurity, eligibility for these programs is usually determined by household income, and those with incomes close to the threshold face uncertainty or may be left out. In many cases, these households turn to energy-limiting behaviors as a strategy to lower their electric utility bills. This paper explores the relationship between energy insecurity and energy-limiting behaviors to investigate alternative solutions that target the households that may fall out of available energy assistance programs. We explore the role of battery energy storage systems and rooftop solar photovoltaics in improving energy affordability. The results show that residential rooftop solar and behind-the-meter energy storage can offset two-thirds of the bill savings that households attain through energy-limiting behavior. Household renewable energy systems could complement existing energy assistance programs to provide long-term bill relief, enabling occupants to live in their homes with comfort and dignity. This dataset is intended to allow readers to reproduce and customize the analysis performed in this work to their benefit.

Kerby, Jessica [Pacific Northwest National Laborat↗

Photovoltaic solar array technology required for three wide scale generating systems for terrestrial applications: rooftop, solar farm, and satellite

Three major options for wide-scale generation of photovoltaic energy for terrestrial use are considered: (1) rooftop array, (2) solar farm, and (3) satellite station. The rooftop array would use solar cell arrays on the roofs of residential or commercial buildings; the solar farm would consist of large ground-based arrays, probably in arid areas with high insolation; and the satellite station would consist of an orbiting solar array, many square kilometers in area. The technology advancement requirements necessary for each option are discussed, including cost reduction of solar cells and arrays, weight reduction, resistance to environmental factors, reliability, and fabrication capability, including the availability of raw materials. The majority of the technology advancement requirements are applicable to all three options, making possible a flexible basic approach regardless of the options that may eventually be chosen. No conclusions are drawn as to which option is most advantageous, since the feasibility of each option depends on the success achieved in the technology advancement requirements specified.

Berman, P. A.↗

Aerial thermal scanner data for monitoring rooftop temperatures

Four Nebraska communities and one South Dakota community were surveyed. Thermal scanner data were converted to a film format and the resultant imagery was successfully employed to monitor rooftop temperatures. The program places emphasis on heat losses resulting from inadequate home insulation, offers CENGAS customers the opportunity to observe a thermogram of their rooftop, and assists homeowners in evaluating insulation needs.

Bjorkland, J.↗

A report on the use of thermal scanner data in an operational program for monitoring apparent rooftop temperatures

CENGAS, a division of Central Telephone and Utilities Corporation in cooperation with the Remote Sensing Institute, South Dakota State University, is using airborne thermal scanner data to monitor relative rooftop temperatures. Four Nebraska communities and one South Dakota community were surveyed by the Remote Sensing Institute for CENGAS. Thermal scanner data were converted to a film format and the resultant imagery has been successfully employed by CENGAS. The program places emphasis on heat losses resulting from inadequate home insulation, offers CENGAS customers the opportunity to observe a thermogram of their rooftop, and assists homeowners in evaluating insulation needs.

Bjorklund, J.↗

Integration of Photovoltaics into Building Energy Usage through Advanced Control of Rooftop Unit

This paper presents a computational approach to forecast photovoltaic (PV) power in kW based on a neural network linkage of publicly available cloud cover data and on-site solar irradiance sensor data. We also describe a control approach to utilize rooftop air conditioning units (RTUs) to support renewable integration. The PV forecasting method is validated using data from a rooftop PV panel installed on the Distributed Energy, Communications, and Controls (DECC) laboratory at Oak Ridge National Laboratory. The validation occurs in multiple phases to ensure that each component of the approach is the best representation of the actual expected output. The control of the RTU is based on model predictive methods.

Starke, Michael R↗

Visual-SOLAR: Modeling and Visualization of Solar Radiation Potential on Individual Building Rooftops

We have developed a modeling framework for estimating solar radiation potentials on individual building rooftops that is suitable for utility-scale applications as well as building-specific applications. The framework uses light detection and ranging (LIDAR) data at approximately 1-meter horizontal resolution and 0.3-meter vertical resolution as input for modeling a large number of buildings quickly. One of the strengths of this framework is the ability to parallelize its implementation. Furthermore, the framework accounts for building specific characteristics, such as roof slope, roof aspect, and shadowing effects, that are critical to roof-mounted photovoltaic system. The resulting data has helped us to identify the so-called "solar panel sweet spots" on individual building rooftops and obtain accurate statistics of the variation in solar radiation as a function of time of year and geographical location.

Source record↗

RM12-2798 High-Efficiency Rooftop Unit Replacement: Hawaii and Guam Energy Improvement Technology Demonstration Project

As part of its overall strategy to meet its energy goals, NAVFAC partnered with NREL to rapidly demonstrate and deploy cost-effective renewable energy and energy efficiency technologies. This high efficiency rooftop unit replacement project was one of several demonstrations of new and underutilized commercial energy efficiency technologies. The common goals were to demonstrate and measure the performance and economic benefits of the system and to monitor any ancillary impacts related to standards of service and operation and maintenance (O and M) practices. In short, these demonstrations simultaneously evaluated the benefits and compatibility of the technologies with the U.S. Department of Defense (DOD) mission, and with NAVFAC's design, construction, and O and M practices.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗