Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Retina”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Funduscopic alterations in the rhesus monkey induced by exposure to heavy ions /0+8/ 250 MeV/nucleon

A heavy-ion, high-energy beam has been extracted from the Lawrence Radiation Laboratory Bevatron, making controlled exposure of biological systems feasible, and a series of experiments have been undertaken to determine the possible deleterious effects of such irradiation upon the primate retina. The left eyes of 54 rhesus monkeys have been exposed to accelerated 0+8 (250 MeV/nucleon). Beam flux ranged from 1.3 x 10 to the 7th particles/ sq cm (171 rads) to 5.9 x 10 to the 8th particles/sq cm (7740 rads). Fundus photography was performed immediately prior to and immediately following exposure, at 24 to 48 hours postexposure and at 1, 2, and 5 weeks postexposure. Punctate hemorrhages of the retina were visible at 1.3 x 10 to the 7th particles/sq cm (171 rads), the lowest exposure level utilized in this study. Acute radiation retinopathy, consisting of geographic retinal hemorrhage and ischemic necrosis of the retina, was not seen until total flux reached 7.7 x 10 to the 7th particles/sq cm (1000 rads).

Beckman, F. N.

Cosmic ray effects on the eyes of rats flown on Cosmos no. 782, Experiment K-007

A study was undertaken to determine if, and to what extent, pathological damage results from high-energy particles (HZE) transversing the eye. Light flashes experienced by space travellers indicate that HZE do indeed pass through and activate the retina, but whether actual biological damage occurs has not been investigated thoroughly. Thus, autopsies were performed on the eyes of rats which has been flown in Cosmos 782 satellite for 19.5 days. Comparisons with a control sample subjected to 1000 rads of Ar and Ne radiation show that pathological damage, when it occurs, affects the nucleus of the retina; simple light flashes are not thought to indicate a pathology, and result from activation of (but not damage to) the retina's outer segments.

Philpott, D. E.

Sunlight reflections from a solar power satellite on solar mirrors should not harm the eyes

The potential hazard imposed by the reflection of the Sun's image by the solar power satellite (SPS) was examined. In the worst case, where the transmitter is assumed to be a perfect mirror reflecting the Sun's image normal to the atmosphere, the total energy received by the eye would be 3.36 x 10 to the -7th power watts. The eye's optics would blur the 5.6 sec of art image of the transmitter over a disk approximately 6 minutes arc in diameter, reducing the maximum intensity at the retina by 99%. A given cone in the retina would receive even less energy due to the constant random microtremors and microsaccadic movements of the eye muscles which move the retina over an area some 8 minutes of arc in radius, even during steady fixation. Therefore, very conservative estimates show that the reflections from the transmitter could be viewed safety for at least 3.2 hours and that the entire SPS structure could be viewed for a minimum of 1 hour. The solares mirror is briefly considered and is shown to be safe to view for at least 2.4 minutes.

Hyson, M. T.

Compensating For Movement Of Eye In Laser Surgery

Conceptual system for laser surgery of retina includes subsystem that tracks position of retina. Tracking signal used to control galvanometer-driven mirrors keeping laser aimed at desired spot on retina as eye moves. Alternatively or additionally, indication of position used to prevent firing of laser when eye moved too far from proper aiming position.

Juday, Richard D.

Stroboscopic Goggles for Reduction of Motion Sickness

A device built around a pair of electronic shutters has been demonstrated to be effective as a prototype of stroboscopic goggles or eyeglasses for preventing or reducing motion sickness. The momentary opening of the shutters helps to suppress a phenomenon that is known in the art as retinal slip and is described more fully below. While a number of different environmental factors can induce motion sickness, a common factor associated with every known motion environment is sensory confusion or sensory mismatch. Motion sickness is a product of misinformation arriving at a central point in the nervous system from the senses from which one determines one s spatial orientation. When information from the eyes, ears, joints, and pressure receptors are all in agreement as to one s orientation, there is no motion sickness. When one or more sensory input(s) to the brain is not expected, or conflicts with what is anticipated, the end product is motion sickness. Normally, an observer s eye moves, compensating for the anticipated effect of motion, in such a manner that the image of an object moving relatively to an observer is held stationary on the retina. In almost every known environment that induces motion sickness, a change in the gain (in the signal-processing sense of gain ) of the vestibular system causes the motion of the eye to fail to hold images stationary on the retina, and the resulting motion of the images is termed retinal slip. The present concept of stroboscopic goggles or eyeglasses (see figure) is based on the proposition that prevention of retinal slip, and hence, the prevention of sensory mismatch, can be expected to reduce the tendency toward motion sickness. A device according to this concept helps to prevent retinal slip by providing snapshots of the visual environment through electronic shutters that are brief enough that each snapshot freezes the image on each retina. The exposure time for each snapshot is less than 5 ms. In the event that a higher rate of strobing is necessary for adequate viewing of the changing scene during rapid head movements, the rate of strobing (but not the exposure time) can be controlled in response to the readings of rate-of-rotation sensors attached to the device.

Reschke, M. F.

Contribution of Spaceflight Environmental Factors to Vision Risks

The risk of visual impairment and elevated intracranial pressure as a result of low-earth orbit microgravity exposure has directed our attention and research efforts to the eye. While the alterations observed in astronauts returning from long duration missions include vision and neuroanatomical changes observed by non-invasive methods, other effects and subsequent tissue responses at the molecular and cellular level can only be studied by accessing the tissue itself. As a result of this need, several studies are currently taking place within the Human and Health Countermeasures Element (HHC) that use animal models for eye research. The rodent eye has many similarities to the human eye, and both rats and mice have historically been used as models of human eye disease, aiding in the identification of the disease genes, elucidation of mechanisms of disease, as well as in the assessment of therapeutic treatments. These studies attempt to answer two central questions in the etiology of possible vision alterations in the environment of space exploration missions. The first is: what effects and response mechanisms take place in the different eye structures at the cellular and molecular level? The second question is directed to elucidate the contribution of the various environmental stressors (radiation, nutrition, fluid shift) to these effects. Collaborative approaches with internal and external investigators have allowed performing these studies in a most cost-effective fashion, providing preliminary data and laying the bases for testing further hypotheses in future and specifically designed animal experiments. From a study centered on the radioadaptive response in mice, we have learned that the retina responds to low and high dose gamma radiation by elevating antioxidant-related genes at early time points (4hrs) and that this response returns to control levels after 1 day post-irradiation. We are expanding this research with another collaborative study that investigates the combined effects of radiation exposure and iron overload on sensitivity to radiation injury in rat eyes. All main eye structures will be analyzed in this study: retina, lens and cornea. A study in collaboration with the Space Human Factors and Habitability Element (SHFH) investigates the effects of lunar dust exposure on the rat cornea. It is anticipated that common underlying oxidative stress mechanisms of damage may be observed as a result of these three stressors: radiation, nutritional iron and lunar dust. The contribution of fluid shift is addressed by a study using rats subjected to hindlimb suspension. The hypothesis to be tested in this study is that the mechanical stress imparted by the pressure differential across the optic disc and lamina cribosa will impact oxygenation (therefore causing oxidative stress and hypoxia) and cell survival. This study also includes the assessment of two nutritional antioxidant countermeasures: epigallocatechin gallate (green tea) and resveratrol. Finally, as a result of two successful tissue sharing efforts, we are proceeding with the analysis of eye samples of mice aboard two shuttle missions: STS-133 and STS-135. Results from the STS-133 study are presented in an independent abstract. Briefly, the results show that spaceflight represents a source of environmental stress that directly translates into oxidative and cellular stress in the retina. Similar analysis is also planned for the cornea. These samples add large value to our current vision research as they provide data on the direct effects of low-earth orbit spaceflight on eye structures and physiology.

Zanello, Susana B.

Spaceflight Effects and Molecular Responses in the Mouse Eye: Observations After Shuttle Mission STS-133

Microgravity-induced cephalad fluid shift and radiation exposure are some of the stressors seen in space exploration. Ocular changes leading to visual impairment in astronauts are of occupational health relevance. Therefore, we analyzed the effects of space flight in the eyes of mice. Six mice were assigned to Flight (FLT), Animal enclosure Module (AEM), or vivarium (VIV) group, respectively. Mice were sacrificed at 1, 5 or 7 days after landing from space. One eye was used for histological and immunohistoche-mistry analysis and the other eye for gene expression profiling. 8-OHdG and caspase-3 immunoreactivity were increased in the retina in FLT samples at return(R+1) compared to AEM/VIV groups, and decreased at day 7 (R+7). beta-amyloid was seen in the nerve fibers at the post-laminar region of the optic nerve in the flight samples (R+7). In addition, oxidative and cellular stress response genes were upregulated in the retina of FLT samples upon landing, and decreased by R+7. According to the results, a reversible molecular damage may occur in the retina of mice exposed to spaceflight followed by protective cellular response.

Prospero-Ponce, Claudia

Vascular Patterning Analysis by VESGEN 2D/3D with Bioinformatics: Updates for Rodent Tissues

Fractally branching vascular systems are a complex physiological requirement shared by humans with all higher terrestrial life forms, including other vertebrates, insects, and higher land plants. Vascular trees, networks, and tree-network composites are therefore mapped and quantified by the VESsel GENeration Analysis (VESGEN) software according to weighted physiological vascular rules that include vessel connectivity, tapering and bifurcational branching. According to fluid dynamics, successful vascular transport depends upon a complex distributed system of highly regulated laminar flow. VESGEN has elucidated changes in vascular patterning resulting from inflammatory, developmental and other signaling pathways within numerous tissues of major model organisms important for Space Biology, especially for rodents. Important early stage regenerative opportunities have been identified by VESGEN vascular analysis for visual impairments in the human retina, and is currently being used for research into astronaut visual and ocular disorders associated with long duration missions. The VESGEN 2D software is a mature, automated, widely published capability for which beta testing and public release by NASA is planned for the upcoming year. Early-stage capabilities for VESGEN 3D analysis are under development for the rodent retina and intestine as prototype tissues. A prototype VESGEN 2D Bioinformatics software capability has also been developed to associate phenotypic changes in molecular expression with vascular structure and function. By new VESGEN bioinformatic innovations, expression patterns of the genetic, transcriptional, protein and other markers for regulatory molecules such as vascular endothelial growth factor (VEGF) and their receptors, often indicators of tissue oxygenation status, are co-localized with alterations in vascular pattern. Biomarkers are therefore mapped and quantified as information dimensions directly correlated with the spatial dimensions of a vascular pattern. Further important technology innovations by NASA include substantial image segmentation advances for more automated binary extraction of the grayscale vascular patterns, together with informative associated image quality assessments. Vascular mapping and quantification capabilities for the rodent retina and intestine are illustrated for VESGEN 2D, along with technology status reports on VESGEN 3D and Bioinformatic capabilities. Research partially supported by Ames Center Innovation Awards.

Parsons-Wingerter, P.

Translational Line of Sight: a multi-omics longitudinal study of the murine retinal response to spaceflight hazard analogs

The space environment includes unique hazards like radiation and microgravity which adversely affect physiology and behavior of humans and rodent models. To better characterize the retinal response to spaceflight, we assessed a multi-omics NASA GeneLab dataset where 6-month-old female mice were gamma irradiated and/or hindlimb unloaded for 21 days followed by whole transcriptome shotgun sequencing (RNA-Seq) and reduced representation bisulfite sequencing (RRBS) of retina samples collected at 7 days, 1 month or 4 months post-exposure. We compared time-matched epigenomic and transcriptomic retinal profiles revealing a total of 4,178 differentially methylated loci or regions, and 457 differentially expressed genes. Highest correlation in methylation differences was seen across different conditions at the same time point (e.g., between radiation exposure and hindlimb unloaded at 7 days). Biological processes related to nucleotide metabolism were enriched in all groups with activation at 1 month and suppression at 7 days and 4 months. Genes and processes related to Notch and Wnt signaling showed alterations 4 months post-exposure. Interestingly, Notch3 and Lrg1 showed differential patterns in the NASA Twins Study in-flight samples and in response to stressors in the murine retina in the current study. A total of 23 genes were both differentially methylated and expressed, including genes involved in retinal disease or cataract development (Crybb3, Fgfr1, Pitpnm3, Sipa1l3, Sox9) and inflammatory response (B4galt6, Ppm1a, Sphk1). To our knowledge, the current multi-omics analysis is the first multi-omics study to interrogate the epigenomic and transcriptomic impacts of radiation and hindlimb unloading on the retina in isolation and in combination. The results provide an insight into the retinal response to individual spaceflight hazard analogs and their interplay at different post-exposure stages and contributes towards a mechanistic understanding of spaceflight-induced vision impairment using ground-based models.

Prachi Kothiyal

A Multi-omics Longitudinal Study of the Murine Retinal Response to Chronic Low-dose Irradiation and/or Simulated Microgravity

The space environment includes unique hazards like radiation and microgravity which adversely affect physiology and behavior of humans and rodent models. To better characterize the retinal response to spaceflight, we assessed a multi-omics NASA GeneLab dataset where 6-month-old female mice were gamma irradiated and/or hindlimb unloaded for 21 days followed by whole transcriptome shotgun sequencing (RNA-Seq) and reduced representation bisulfite sequencing (RRBS) of retina samples collected at 7 days, 1 month or 4 months post-exposure. We compared time-matched epigenomic and transcriptomic retinal profiles revealing a total of 4,178 differentially methylated loci or regions, and 457 differentially expressed genes. Highest correlation in methylation differences was seen across different conditions at the same time point (e.g., between radiation exposure and hindlimb unloaded at 7 days). Biological processes related to nucleotide metabolism were enriched in all groups with activation at 1 month and suppression at 7 days and 4 months. Genes and processes related to Notch and Wnt signaling showed alterations 4 months post-exposure. Interestingly, Notch3 and Lrg1 showed differential patterns in the NASA Twins Study in-flight samples and in response to stressors in the murine retina in the current study. A total of 23 genes were both differentially methylated and expressed, including genes involved in retinal disease or cataract development (Crybb3, Fgfr1, Pitpnm3, Sipa1l3, Sox9) and inflammatory response (B4galt6, Ppm1a, Sphk1). To our knowledge, the current multi-omics analysis is the first multi-omics study to interrogate the epigenomic and transcriptomic impacts of radiation and hindlimb unloading on the retina in isolation and in combination. The results provide an insight into the retinal response to individual spaceflight hazard analogs and their interplay at different post-exposure stages and contributes towards a mechanistic understanding of spaceflight-induced vision impairment using ground-based models.

Prachi Kothiyal

Renin-Angiotensin System (RAS) in Hematopoietic Stem/Progenitor Cells (HS/PC) Predicts Vaso-Reparative Dysfunction and Progression of Diabetic Retinopathy (DR)

Purpose: We tested the hypothesis that loss of angiotensin converting enzyme 2 (ACE2) within diabetic HS/PCs (Hematopoietic Stem/Progenitor Cells) would be detrimental to HS/PC reparative function, and alter their ability to contribute to vascular remodeling in human subjects and rodent models of DR (Diabetic Retinopathy). Methods: Subjects (n52) were recruited as controls (n13) or diabetics (n39) with either no DR, mild non-proliferative DR (NPDR), moderate NPDR, severe NPDR or proliferative DR (PDR). Fluorescein angiograms were analyzed using Vessel Generation Analysis (VESGEN) software in a cohort of subjects. CD34+ HS/PCs were isolated from peripheral blood. RAS (Renin-Angiotensin System) gene expression and migration was measured. Diabetic ACE2 knockout (KO)C57BL6-Ins2 (Akita) mice at 3, 6 and 9 months of diabetes were compared to age-matched controls. Bone marrow HS/PC populations were analyzed by flow cytometry and migration and proliferation studies performed. Results: ACE2 gene expression in human CD34+ cells from diabetics without DR was increased compared to controls (p0.0437). Mas receptor mRNA was also increased in diabetics without DR, but reduced with the onset of NPDR (p0.0002), suggesting a loss of compensation. DR was associated with CD34+ cell migratory dysfunction. By VESGEN analysis, vessel density measured by several confirming parameters in early NPDR (n3) was greater than in normal retina (n6) in both arteries and veins, which suggests active retinal remodeling. ACE2KO-Akita and Akita cohorts showed reduced retinal thickness by OCT (Optical Coherence Tomography) at 9 months of diabetes. Absence of ACE2 in 9-month Akita mice led to an accelerated increase in acellular capillaries compared to diabetic alone. Electroretinogram (ERG) in ACE2KO-Akita mice resulted in persistent deterioration of the neural retina. Reparative function studies showed that ACE2KO exacerbated diabetes-induced impairment of LK (Low Potassium) cell migration and proliferative functions as early as 3-month of diabetes (p0.0019). Conclusions: Retinopathy and adverse vascular remodeling in subjects with diabetes was associated with a loss of the protective arm of RAS in HS/PCs. Loss of ACE2 exacerbated vascular dysfunction in diabetic mice.

retina

Cadmium-Free QD Building Blocks for Human Centric Lighting

This project developed Cd-free quantum dot (QD) downconverters for efficacious human-centric lighting (HCL) light emitting diode (LED) devices. Solid state HCL devices address the lack of light in the cyan wavelength region (460-490 nm) in white LEDs by enhancing the melanopic daylight efficacy ratio (MDER) value. MDER is a metric that indicates the degree to which artificial lighting stimulates nonvisual biological processes in the retina responsible for regulating circadian rhythms compared with natural lighting. The peak sensitivity of melanopsin in the retina is at 479 nm, therefore artificial lighting which can fill the well-known “cyan gap” may improve human health. Due to the Restriction of Hazardous Substances (RoHS) regulations, cadmium-free core/shell/shell QDs are the primary targets for low toxicity, tunable downconverters. Cyan- and red-emitting core/shell/shell QDs were implemented in LED devices toward achieving a brightness of 210 lm/W at 4000 K, CRI 90, and MDER > 0.7. Synthetic development of Cd-free materials yielded cyan InP/ZnS QDs with a photoluminescence quantum yield (PLQY) of ~60% between 480-490 nm, and red InP/ZnSe/(ZnSeS)/ZnS QDs reaching ~80% PLQY at 620-630 nm. We successfully demonstrated that the inclusion of cyan QDs increased the MDER value to ≥0.7, but the brightness of the HCL LED devices was hindered due to low PLQY values. However, upon substitution of the Cd-free cyan QD with a low-Cd QD with >90% PLQY, brightness improved by 25% over the Cd-free device to 179 lm/W. Despite the technical obstacles remaining toward improving emission characteristics and stability of QDs under high flux, we have confirmed the promise of narrow, tunable QD emitters in SSL packages toward the goal of healthy, human-centric lighting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Sensory, Decision and Control Systems: April to July 1966

The quarter reported here for the NASA contract, and the longer period reported for the Air Force contract, saw the development of two system concepts for the transmission of video data from a remote location to Earth. In the simpler system, a stereoscopic outline together with other data such as reflectance and possibly the texture of objects will be transmitted to Earth. The objects considered are those larger than a predetermined size and within a predetermined range. From the stereoscopic outlines presented to the operator on Earth he will decide what objects he would like pictured in full TV frames and order these transmitted. In the more elaborate system, TV cameras will be carried on a vehicle and the direction in which the vehicle moves will be chosen by an onboard decision computer. Perceptual decisions may also be made to identify objects whose characteristics have been reported to Earth and whose value to the Earth observer has been communicated back to the perceptual computer. The assembly of cameras, perceptual computer, decision computer and vehicle is called a robot. Photosensors for this robot are television cameras, the first models of which have been tested under computer control. A model of both the perceptual computer and the decision computer has been simulated. It consists of 12 modules, each of which makes an initial guess as to what the response to incoming data should be. Each takes the data from all other modules and combines it in a nonlinear fashion with the data coming directly into it to arrive at a mixed guess as to what act should be performed. When 60% of the modules vote 0. 5 probability for one act, that act is performed. Convergence to a satisfactory decision took from 5 to 25 time steps. The model of the frog's retina previously reported is here extended to that part of the brain, called the tectum, where the frog begins to respond to objects detected by the retina.

Control system

Automatic optometer operates with infrared test pattern

Refractive strength of human eye is monitored by optometer that automatically and continuously images infrared test pattern onto the retina. Condition of focus of the eye at any instant is determined from optometer settings needed to maintain focus of the pattern on the retina.

Cornsweet, T. N.

Human visual response to nuclear particle exposures

Experiments with accelerated helium ions were performed in an effort to localize the site of initial radiation interactions in the eye that lead to light flash observations by astronauts during spaceflight. The character and efficiency of helium ion induction of visual sensations depended on the state of dark adaptation of the retina; also, the same events were seen with different efficiencies and details when particle flux density changed. It was concluded that fast particles cause interactions in the retina, particularly in the receptor layer, and thus give rise to the sensations of light flashes, streaks, and supernovae.

Tobias, C. A.

System and method for character recognition

A character recognition system is disclosed in which each character in a retina, defining a scanning raster, is scanned with random lines uniformly distributed over the retina. For each type of character to be recognized the system stores a probability density function (PDF) of the random line intersection lengths and/or a PDF of the random line number of intersections. As an unknown character is scanned, the random line intersection lengths and/or the random line number of intersections are accumulated and based on a comparison with the prestored PDFs a classification of the unknown character is performed.

Hong, J. P.

Photographic Screening for Eye Defects

Images of retinas examined for characteristic patterns. Color photographs of retinas taken. Proper alinement of eye obtained by asking subject to gaze at light-emitting diode. "Red-eye" patterns in resulting color photographs examined by trained observers for signs of ocular defects. System used to check power of contact lenses and eyeglasses by taking photographs with these items in place.

Richardson, J.

Generation-V dual-Purkinje-image eyetracker

Major advances characterize the Generation-V dual-Purkinje-image eyetracker compared with the Generation-III version previously described. These advances include a large reduction in size, major improvements in frequency response and noise level, automatic alignment to a subject, and automatic adjustment for different separation between the visual and optic axes, which can vary considerably from subject to subject. In a number of applications described in the paper, the eyetracker is coupled with other highly specialized optical devices. These applications include accurately stabilizing an image on a subject's retina; accurately simulating a visually dead retinal region (i.e., a scotoma) of arbitrary shape, size, and position; and, for clinical purposes, stabilizing the position of a laser coagulator beam on a patient's retina so that the point of contact is unaffected by the patient's own eye movements.

Crane, H. D.