Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reservoir flow model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Numerical analysis of rarefied slit flows. II - Navier-Stokes simulations

The model problem of pressure-driven flow of a rarefied monatomic gas through a two-dimensional slit is analyzed via full Navier-Stokes numerical simulation. Parametric solutions are generated for slit-height based Knudsen number ranging from continuum to transitional flow and for reservoir pressure ratios leading to subsonic and supersonic flow. The change in the structure of the flowfield near the slit as a function of pressure ratio and Knudsen number are quantified from a purely continuum standpoint. The choice of numerical domain size, boundary conditions and treatment of the slit are also discussed. As expected, comparison with a Direct Simulation Monte Carlo solution for a highly rarefied case shows large differences in the predicted mass flow. The cause of these differences can be quantified through detailed comparison of the local flowfield properties. For the larger pressure ratio cases qualitative trends with increasing rarefaction are discussed, including the change in the sonic line shape in the slit and the in total mass flow.

Wadsworth, D. C.↗

High thermal capacity cold plate/hot plate

The results of an analytical study to determine the feasibility of a novel two-phase cold plate/hot plate (CPHP) are presented. A key feature of the CPHP is the use of capillary forces to separate the liquid and vapor phases and distribute the liquid over the evaporating/condensing surface. The liquid phase is held by capillary forces in a reservoir and is carried to the evaporating surface by a wick. The reservoir is replenished at intervals from a valved external liquid supply line. In the hot plate mode, liquid accumulates in the reservoir and is removed by an external condensate line. Performance requirements for the device were capability of handling a power density of 4 watts/sq cm, an outlet quality (percentage of vapor flow to total flow) greater than 90 percent, and operation in a 0-g environment. An analytical model of CPHP operation was developed which concentrated on the liquid and vapor flows. It was found that the liquid carrying capillary grooves of rectangular cross-section gave significantly better predicted performance than V-shaped grooves. Using the analytical model, capillary groove width and length, vapor channel dimensions, and other parameters were selected to meet the performance requirements with a 100-percent margin.

Hwangbo, H.↗

Old Faithful Model for Radiolytic Gas-Driven Cryovolcanism at Enceladus

A new model is presented on how chemically driven cryovolcanism might contribute to episodic outgassing at the icy moon Enceladus and potentially elsewhere including Europa and Kuiper Belt Objects. Exposed water ices can become oxidized from radiolytic chemical alteration of near-surface water ice by space environment irradiation. In contact with primordially abundant reductants such as NH3, CH4, and other hydrocarbons, the product oxidants can react exothermically to produce volatile gases driving cryovolcanism via gas-piston forces on any subsurface liquid reservoirs. Radiolytic oxidants such as H2O2 and O2 can continuously accumulate deep in icy regoliths and be conveyed by rheological flows to subsurface chemical reaction zones over million-year time scales indicated by cratering ages for active regions of Enceladus and Europa. Surface blanketing with cryovolcanic plume ejecta would further accelerate regolith burial of radiolytic oxidants. Episodic heating from transient gravitational tides, radioisotope decay, impacts, or other geologic events might occasionally accelerate chemical reaction rates and ignite the exothermic release of cumulative radiolytic oxidant energy. The time history for the suggested "Old Faithful" model of radiolytic gas-driven cryovolcanism at Enceladus and elsewhere therefore consists of long periods of chemical energy accumulation punctuated by much briefer episodes of cryovolcanic activity. The most probable sequence for detection of activity in the current epoch is a long evolutionary phase of slow but continuous oxidant accumulation over billions of years followed by continuous but variable high activity over the past 10(exp 7)-10(exp 8) years. Detectable cryovolcanic activity could then later decline due to near-total oxidation of the rheologically accessible ice crust and depletion the accessible reductant abundances, as may have already occurred for Europa in the more intense radiation environment of Jupiter's magnetosphere. Astrobiological potential of Enceladus could correspondingly be higher than at Europa due to a less extreme state of oxidation and greater residual abundance of organics.

Cooper, John F.↗

Thermal evolution of the earth - Effects of volatile exchange between atmosphere and interior

The thermal history of the earth is investigated using a parameterized model of mantle convection, that includes the effects of volatile exchange between the mantle and the surface reservoir and the softening of the mantle by the dissolved volatiles. The mantle degassing rate is taken to be directly proportional to the rate of seafloor spreading which depends on the mantle heat flow. It is shown that the dependence of the mantle viscosity on the volatile content has important effects on the thermal evolution of planetary interiors and the evolution of planetary atmospheres. Degassing is compensated by an increase in temperature, while regassing is compensated by a decrease in temperature. Reasonable degassing scenarios can account for an early rapid formation of the earth's atmosphere inferred from noble gas abundances.

Mcgovern, Patrick J.↗

The variation of magma discharge during basaltic eruptions

The different types of magmatic flow in basaltic eruptions are discussed, and processes explaining the eruptive history of specific volcanoes are investigated. The effusion rate curve is divided into waxing and waning flow parts, and the ideal, elastic response of the reservoir in the waning phase is analytically shown. Historical eruption rates of Mauna Loa, Kilauea, and Etna are presented, demonstrating that for each volcano there is a trend of decreasing rate with increasing duration of eruption, a relationship not predicted by a simple elastic model of magma release. The eruptive histories of these volcanoes is explained by the processes of modification of the eruptive conduits and the continued supply of magma from depth during eruption. Discharge variations from Paricutin, Hekla, and Kilauea Iki are discussed in detail.

Wadge, G.↗

Time-dependent dusty gasdynamical flow near cometary nuclei

This paper presents time-dependent solutions to the coupled dusty hydrodynamics equations describing the spherically symmetric expansion of cometary neutral gas in the vicinity of a cometary nucleus. The sublimation process is repressented by gas outflow from a dust-covered reservoir containing stationary gas whose pressure and density values are determined by the sublimating (Ts) and surface (T0) temperatures. The model resolves earlier ambiguities in determining gas production rates and provides analytic relations between Ts, T0, and the gas parameters at the sonic point. The time evolution of a cometary outburst was modeled. It was found that, as a result of the strong gas-dust interaction in the inner coma region, a 'slow' disturbance in both the dust and gas parameters will be created in addition to the familiar gas blast-wave solution. This new 'slow' disturbance, which propagates with a velocity of about 0.2 km/s, might be responsible for some of the observed slowly expanding cometary halos, such as the one which was recently identified using 1910 Mount Wilson high-resolution comet Halley photographs.

Gombosi, T. I.↗

The Iodine Satellite (iSat) Propellant Feed System - Design and Demonstration

CUBESATS are relatively new spacecraft platforms that are typically deployed from a launch vehicle as a secondary payload, providing low-cost access to space for a wide range of end-users. These satellites are comprised of building blocks having dimensions of 10x10x10 cm3 and a mass of 1.33 kg (a 1-U size). While providing low-cost access to space, a major operational limitation is the lack of a propulsion system that can fit within a CubeSat and is capable of executing high Delta V maneuvers. This makes it difficult to use CubeSats on missions requiring certain types of maneuvers (i.e. formation flying, spacecraft rendezvous). Work has been performed investigating the use of iodine as a propellant for Hall-effect thrusters (HETs) that could subsequently be used to provide a high specific impulse path to CubeSat propulsion. One of the systems under development to support such a technology is the propellant feed system, which must be capable of storing solid iodine propellant, applying heat to sublime the stored solid into the vapor phase, and then control the flow of low-pressure gaseous iodine to both the thruster and cathode. In a test conducted in 2016, a first-generation iodine propellant feed system was integrated with a cathode and Hall thruster. While this test had to be terminated, the feed system in this first test was able to support both cathode and integrated cathode and thruster operation prior to the termination of the test. In the present paper, we describe work performed since that initial integrated test. The effort uses lessons learned from the previous integrated test, retiring risk associated with the iodine propellant feed system, answering open design-space questions, and demonstrating iodine flow control in an integrated system. The work is undertaken at both the component level and then at the integrated subsystem level to systematically improve the feed system design, improving the hardware fidelity so the appearance and operation of the system are as flight-like as possible. At the component level, the work focuses on the propellant tank, the feed system tubing, the valves used to control the flow to the cathode and thruster, and the heaters that maintain the temperature of the flowpaths and keep iodine from redepositing and clogging the system. Work on the propellant reservoir focuses on fabricating a tank that matches the geometry of the flight design, which allows for the identification of flight tank fabrication issues that may arise and permits thermal testing of a tank possessing the same size and thermal mass as the flight design, which can be used to anchor thermal modeling of the component. This is critical for finalizing the tank heater power requirements that feed into the heater design. All metallic materials in the feed system are hastelloy or Inconel, as these materials are resistant to chemical attack by the highly-reactive iodine vapor. The tubing in the iodine feed system must possess ports to permit a neutral gas purge of the system that clear impurities after iodine is loaded into the propellant tank. A procedure is discussed whereby these ports are crimped and sealed after the purge process is completed so as to not re-expose the iodine system to air. The valves are a critical component for control of the flow to the thruster and the cathode. Significant effort has gone into upgrading the materials of the valves to make them more resistant to chemical attack and into developing an understanding of the use of these valves during the startup and operation of the cathode and thruster. The heaters that line the entire feed system are designed to draw minimal power from the power processing unit (PPU) while still having the capacity to maintain all the feed system components at the temperatures required to discourage iodine deposition inside components downstream of the propellant tank exit. The heaters possess two separate resistive traces, giving the design redundancy should a failure occur in the primary heater circuit of one of the heater zones. The task of operating a feed system in conjunction with a thruster and cathode is undertaken in a series of sub-steps. The system is first assembled and operated on xenon gas, using the valves for cathode startup and thruster control based on measurement of the discharge current. After startup and control on xenon are demonstrated, the thruster will be transitioned to iodine operation, demonstrating thruster startup and feed system control while using a xenon-fed cathode. Finally, the last step is to integrate an iodine-compatible cathode with the system, demonstrate autonomous cathode start-up with open-loop control and thruster start-up with closed-loop control for multiple cycles.

Polzin, Kurt A.↗

Numerical simulation of rarefied gas flow through a slit

Two different approaches, the finite-difference method coupled with the discrete-ordinate method (FDDO), and the direct-simulation Monte Carlo (DSMC) method, are used in the analysis of the flow of a rarefied gas from one reservoir to another through a two-dimensional slit. The cases considered are for hard vacuum downstream pressure, finite pressure ratios, and isobaric pressure with thermal diffusion, which are not well established in spite of the simplicity of the flow field. In the FDDO analysis, by employing the discrete-ordinate method, the Boltzmann equation simplified by a model collision integral is transformed to a set of partial differential equations which are continuous in physical space but are point functions in molecular velocity space. The set of partial differential equations are solved by means of a finite-difference approximation. In the DSMC analysis, three kinds of collision sampling techniques, the time counter (TC) method, the null collision (NC) method, and the no time counter (NTC) method, are used.

Keith, Theo G., Jr.↗

X-15 hydraulic-system development

Despite the exacting requirements and conditions of the X-15 including much higher temperature, high horsepower, and extreme vibration and duty cycles, the hydraulic flight control systems compare favorably, weightwise, with preceding models. Although some items, such as the pumps, are heavier, the total system, excluding actuators, weighs approximately 195 pounds as compared with 196 pounds for the F-107A airplane. Use of the new piggy-back pump, with its low flow during most of the operating time, also permitted a reduction in fluid capacity of the hydraulic reservoirs and the total systems, even though the volume of some of the actuators is quite large. This effected a considerable saving in fluid weight. Complete ground-support equipment is available and this equipment, as well as the airplane systems, contains means for complete 5- to 15- micron filtration under controlled temperature conditions. By use of advanced engineering techniques and extensive laboratory testing, it has been possible to provide a sound, lightweight hydraulic system for this advanced, high-performance airplane. (author)

Culleton, R J↗

Computation of nonequilibrium viscous flows in arc-jet wind tunnel nozzles

The axisymmetric Navier-Stokes equations are numerically solved for air flows in converging-diverging conical nozzles. A nonequilibrium formulation with a two-temperature thermochemical model has been employed for vibrationally excited, partially dissociated and ionized air. Evaluations of the formulation is made through comparisons of the computed flow quantities with the experimental data obtained in expanding arc-jet nozzle flows. Two sets of experimental data obtained in conical nozzles with geometric exit-to-throat area ratios of 625 and 8100 cover reservoir pressures ranging from 5 to 95 atm and enthalpies from 5 to 10 MJ/kg. The computed results are in good agreement with local mass flux, Pitot pressure, and static wall pressure measurements at the nozzle exit. For low pressure reservoir conditions, comparisons of computations with the experimental data indicate that the wall catalycity is very important in predicting species mole fraction at the nozzle exit since gas phase chemistry is frozen. The current computations overpredict the atomic oxygen concentrations which in turn results in underprediction of the vibrational temperature.

Gokcen, Tahir↗

The variation of magma discharge during basaltic eruptions

The rate at which basaltic magma is discharged during many eruptions varies substantially. An individual eruption has an eruption rate, which is the volumetric rate of discharge averaged over the whole or a major part of an eruption, and an effusion rate, which is the volumetric flux rate at any given time. In many cases, the effusion rate soon reaches a maximum after a short period of waxing flow (partly because of magmatic expansion); it then falls more slowly in the later parts of the eruption. The release of elastic strain energy from stored magma and the subvolcanic reservoir during eruption can give a waning flow of this type an exponential form. A comparison of the eruption rates of eruptions of Mauna Loa, Kilauea and Etna shows that for each volcano there is a trend of decreasing effusion rate with increasing duration of eruption. It is noted that this relationship is not predicted by a simple elastic model of magma release. Two other processes are invoked to explain the eruptive histories of these volcanoes: modification of the eruptive conduits and the continued supply of magma from depth during eruption.

Wadge, G.↗

Sodium Variable Conductance Heat Pipe for Radioisotope Stirling Systems

In a Stirling radioisotope system, heat must continually be removed from the General Purpose Heat Source (GPHS) modules to maintain the modules and surrounding insulation at acceptable temperatures. Normally, the Stirling convertor provides this cooling. If the converter stops in the current system, the insulation is designed to spoil, preventing damage to the GPHS, and also ending the mission. An alkali-metal Variable Conductance Heat Pipe (VCHP) has been designed to allow multiple stops and restarts of the Stirling convertor in an Advanced Stirling Radioisotope Generator (ASRG). When the Stirling convertor is turned off, the VCHP will activate when the temperatures rises 30 C above the setpoint temperature. A prototype VCHP with sodium as the working fluid was fabricated and tested in both gravity aided and against gravity conditions for a nominal heater head temperature of 790 C. The results show very good agreement with the predictions and validate the model. The gas front was located at the exit of the reservoir when heater head temperature was 790 C while cooling was ON, simulating an operating Advanced Stirling Converter (ASC). When cooling stopped, the temperature increased by 30 C, allowing the gas front to move past the radiator, which transferred the heat to the case. After resuming the cooling flow, the front returned at the initial location turning OFF the VCHP. The against gravity working conditions showed a colder reservoir and faster transients.

Tarau, Calin↗

Passive Water Assurance Delivery System

This report provides an analysis and evaluation of proposed design improvements to the internal water delivery system of NASA’s passive vegetable growing system. The VEGGIE system is designed to provide fresh vegetables and psychological benefits for astronauts aboard the International Space Station. Preliminary testing conducted by NASA for the VEGGIE system revealed flaws in the water delivery system. In these tests, the interface between the plants and the water reservoir failed to provide passive water delivery through the system both in microgravity experiments and experiments conducted on Earth. Our team’s goal was to fix this interface such that water can be passively delivered from the water reservoir to the plant rooting pillows to grow vegetative crops from seed to harvest. The system requirements outlined by NASA include: minimal total mass, on-demand passive water delivery, same dimensions as existing fixtures, minimal pressure on system to prevent leaking, zero mold growth, minimal swelling or clogging for non-flammable capillary materials, pressure stabilization between the water reservoir and plant pillow bags, even dispersal of water during initial priming, minimal bubble obstruction of capillary interface, maximum gas availability to plant roots, growth in a mixed artificial media (50:50 Arcillite:Fafard #2), and to avoid overwatering and drought conditions for plants. The major proposed design improvements are to use a single-interface capillary cord design to directly connect the water reservoir to the plant-rooting pillows, and to alter the water reservoir to model a propellant management device (PMD) in order to ensure consistent and long term watering for the VEGGIE system. The plant rooting pillow required minimal changes outside of replacing the capillary mat on the bottom of the pillow with O-ring insertion points the single-interface capillary system. - Research was conducted to determine which materials are able to uptake water through capillary action to grow Outredgeous Lettuce plants from seed to harvest. The primary requirements to be met by the team's design and evaluation of the capillary interface were: continuous passive watering for 90 days using non-flammable capillary materials and a peak water delivery rate of 30 mL/hr./0.15 m 2 . The results of the team's experimentation showed that the capillary material Nomex displayed the highest capillary water delivery potential with a maximum flow rate of 3.6 mL/hr. The Nomex capillary systems were the only capillary material to consistently grow Outredgeous Lettuce plants from seed to harvest, and displayed the highest average flow rate for multiple experiment sets. The Nomex material was previously incorporated into the VEGGIE system using a matted version of the capillary material, though the team recommends using a cord configuration in the single-interface capillary system for greater system stability. Nomex has proven to be a promising material, as it has passed both health and fire standards for use aboard the International Space Station. PMDs are made of materials that utilize surface tension and adhesive forces to overcome adverse accelerations to improve stability and ensure fluid delivery. PMDs are typically used in fuel tanks to ensure fuel delivery. The team recommends using a sponge PMD in order to mitigate bubble obstruction, decrease system weight, and ensure reliable water delivery to the capillary interface. The PMD water reservoir requires a rigid water reservoir and a vent tube for pressure stabilization. Since PMD’s cannot be tested in 1-G (Earth conditions), further theoretical modeling and testing is required for the proposed water reservoir design. The intent of this proposed system is to passively water plants in microgravity, though the technology is not limited to microgravity applications. The testing at The Ohio State University has proven that the design is highly effective on Earth, demonstrating that it could serve as a simple water delivery system in home and office applications. This would make vegetative crops more accessible in all indoor applications, thereby improving indoor air quality and occupant comfort. Additionally, this technology has great potential to be utilized in greenhouse plant production, cutting back on more sophisticated watering system energy and time requirements.

Alexandria Jensen↗

Catalytic recombination of nitrogen and oxygen on high-temperature reusable surface insulation

The energy transfer catalytic recombination coefficient for nitrogen and oxygen recombination on the surface coating of high-temperature reusable surface insulation (HRSI) is inferred from stagnation point heat flux measurements in a high-temperature dissociated arc jet flow. The resulting catalytic recombination coefficients are correlated with an Arrhenius model for convenience, and these expressions may be used to account for catalytic recombination effects in predictions of the heat flux on the HRSI thermal protection system of the Space Shuttle Orbiter during reentry flight. Analysis of stagnation point pressure and total heat balance enthalpy measurements indicates that the arc heater reservoir conditions are not in chemical equilibrium. This is contrary to what is usually assumed for arc jet analysis and indicates the need for suitable diagnostics and analyses, especially when dealing with chemical reaction phenomena such as catalytic recombination heat transfer effects.

Scott, C. D.↗

California Reservoir Inflow Projections Using a Hybrid EMD-Matalas Method

Inflow projections provide scenarios for future water availability and are integral to operational reservoir management. They can aid water practitioners in decision-making for conservation efforts, multiyear storage retention, managing flood risk, downstream water releases, and regional growth planning. However, conventional methods are often limited in terms of their ability to incorporate non-stationarity, long run persistence, and the cross-correlation of multiple series in a region. This research aims to address these issues with a hybrid approach that integrates Empirical Mode Decomposition (EMD) with the Matalas multisite generation method. Multiple long-run inflows were examined for the Shasta/Trinity Reservoirs and Oroville Reservoir of California. EMD is used to decompose each inflow series into a set of independent intrinsic mode functions (IMFs) that have different timescales and frequencies. These IMFs were grouped into intradecadal (less-than- 10-year average periodicity) and interdecadal (greater-than-10-year average periodicity) series for each site. The IMF projections at each site were then combined to produce replicates of the historical data. This preserves the correlation structure of the intra- and interdecadal components of the series. The hybrid EMD-Matalas method was compared to a traditional autoregressive lag-one model. Both methods were found to retain the statistical characteristics of the historical data. However, the EMD-Matalas method retained the multiyear wet and dry periods to a greater degree. This was examined by comparing the 5-year and 10-year sums from the traditional model with the hybrid EMD-Matalas model. An advantage of the EMD-Matalas method is the ability to explicitly incorporate modes of non-stationary long-run persistence often associated with large-scale climate drivers such as the El Nino Southern Oscillation (ENSO) or the Pacific Decadal Oscillation (PDO). This contributes to scenario planning that may be particularly important for managing multiyear low flow periods.

inflow projections↗

Design of a variable area diffuser for a 15-inch Mach 6 open-jet tunnel

The Langley 15-inch Mach 6 High Temperature Tunnel was recently converted from a Mach 10 Hypersonic Flow Apparatus. This conversion was effected to improve the capability of testing in Mach 6 air at relatively high reservoir temperatures not previously possible at Langley. Elevated temperatures allow the matching of the Mach numbers, Reynolds numbers, and ratio of wall-to-adiabatic-wall temperatures (TW/Taw) between this and the Langley 20-inch Mach 6 CF4 Tunnel. This ratio is also matched for Langley's 31-inch Mach 10 Tunnel and is an important parameter useful in the simulation of slender bodies such as National Aerospace Plane (NASP) configurations currently being studied. Having established the nozzle's operating characteristics, the decision was made to install another test section to provide model injection capability. This test section is an open-jet type, with an injection system capable of injecting a model from retracted position to nozzle centerline between 0.5 and 2 seconds. Preliminary calibrations with the new test section resulted in Tunnel blockage. This blockage phenomenon was eliminated when the conical center body in the diffuser was replaced. The issue then, is to provide a new and more efficient variable area diffuser configuration with the capability to withstand testing of larger models without sending the Tunnel into an unstart condition. Use of the 1-dimensional steady flow equation with due regard to friction and heat transfer was employed to estimate the required area ratios (exit area / throat area) in a variable area diffuser. Correlations between diffuser exit Mach number and area ratios, relative to the stagnation pressure ratios and diffuser inlet Mach number were derived. From these correlations, one can set upper and lower operating pressures and temperatures for a given diffuser throat area. In addition, they will provide appropriate input conditions for the full 3-dimensional computational fluid dynamics (CFD) code for further simulation studies.

Loney, Norman W.↗

Optic Nerve Sheath Mechanics and Permeability in VIIP Syndrome

Long-duration space flight carries the risk of developing Visual Impairment and Intracranial Pressure (VIIP) syndrome, a spectrum of ophthalmic changes including posterior globe flattening, choroidal folds, distension of the optic nerve sheath (ONS), optic nerve kinking and potentially permanent degradation of visual function. The slow onset of VIIP, its chronic nature, and certain clinical features strongly suggest that biomechanical factors acting on the ONS play a role in VIIP. Here we measure several relevant ONS properties needed to model VIIP biomechanics. The ONS (meninges) of fresh porcine eyes (n7) was reflected, the nerve proper was truncated near the sclera, and the meninges were repositioned to create a hollow cylinder of meningeal connective tissue attached to the posterior sclera. The distal end was cannulated, sealed, and pressure clamped (mimicking cerebrospinal fluid [CSF] pressure), while the eye was also cannulated for independent control of intraocular pressure (IOP). The meninges were inflated (CSF pressure cycling 7-50 mmHg) while ONS outer diameter was imaged. In another set of experiments (n4), fluid permeation rate across the meninges was recorded by observing the drainage of an elevated fluid reservoir (30 mmHg) connected to the meninges. The ONS showed behavior typical of soft tissues: viscoelasticity, with hysteresis in early preconditioning cycles and repeatable behavior after 4 cycles, and nonlinear stiffening, particularly at CSF pressures 15 mmHg (Figure). Tangent moduli measured from the loading curve were 372 101, 1199 358, and 2050 379 kPa (mean SEM) at CSF pressures of 7, 15 and 30 mmHg, respectively. Flow rate measurements through the intact meninges at 30mmHg gave a permeability of 1.34 0.46 lmincm2mmHg (mean SEM). The ONS is a tough, strain-stiffening connective tissue that is surprisingly permeable. The latter observation suggests that there could be significant CSF drainage through the ONS into the orbit, likely important for CSF transport in the optic nerve. These experimental measurements, extended to human eyes, are informing computational models of the pathophysiology and biomechanics of the ONS in VIIP syndrome.

biomechanics↗

Biomechanics of the Optic Nerve Sheath in VIIP Syndrome

Long-duration space flight carries the risk of developing Visual Impairment and Intracranial Pressure (VIIP) syndrome, a spectrum of ophthalmic changes including posterior globe flattening, choroidal folds, distension of the optic nerve sheath (ONS), optic nerve kinking and potentially permanent degradation of visual function. The slow onset of VIIP, its chronic nature, and certain clinical features strongly suggest that biomechanical factors acting on the ONS play a role in VIIP. Here we measure several relevant ONS properties needed to model VIIP biomechanics. The ONS (meninges) of fresh porcine eyes (n7) was reflected, the nerve proper was truncated near the sclera, and the meninges were repositioned to create a hollow cylinder of meningeal connective tissue attached to the posterior sclera. The distal end was cannulated, sealed, and pressure clamped (mimicking cerebrospinal fluid [CSF] pressure), while the eye was also cannulated for independent control of intraocular pressure (IOP). The meninges were inflated (CSF pressure cycling 7-50 mmHg) while ONS outer diameter was imaged. In another set of experiments (n4), fluid permeation rate across the meninges was recorded by observing the drainage of an elevated fluid reservoir (30 mmHg) connected to the meninges. The ONS showed behavior typical of soft tissues: viscoelasticity, with hysteresis in early preconditioning cycles and repeatable behavior after 4 cycles, and nonlinear stiffening, particularly at CSF pressures 15 mmHg (Figure). Tangent moduli measured from the loading curve were 372 101, 1199 358, and 2050 379 kPa (mean SEM) at CSF pressures of 7, 15 and 30 mmHg, respectively. Flow rate measurements through the intact meninges at 30mmHg gave a permeability of 1.34 0.46 lmincm2mmHg (mean SEM). The ONS is a tough, strain-stiffening connective tissue that is surprisingly permeable. The latter observation suggests that there could be significant CSF drainage through the ONS into the orbit, likely important for CSF transport in the optic nerve. These experimental measurements, extended to human eyes, are informing computational models of the pathophysiology and biomechanics of the ONS in VIIP syndrome.

fluid shifts↗