Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Refraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

An automated approach to the alignment of compound refractive lenses

Compound refractive lenses (CRLs) are established X-ray focusing optics, and are used to focus the beam or image the sample in many beamlines at X-ray facilities. While CRLs are quite established, the stack of single lens elements affords a very small numerical aperture because of the thick lens profile, making them far more difficult to align than classical optical lenses that obey the thin-lens approximation. This means that the alignment must be very precise and is highly sensitive to changes to the incident beam, often requiring regular readjustments. Some groups circumvent the full realignment procedure by using engineering controls ( e.g. mounting optics) that sacrifice some of the beam's focusing precision, i.e. spot size, or resolution. While these choices minimize setup time, there are clear disadvantages. This work presents a new automated approach to align CRLs using a simple alignment apparatus that is easy to adapt and install at different types of X-ray experiments or facilities. This approach builds on recent CRL modeling efforts, using an approach based on the Stochastic Nelder–Mead (SNM) simplex method. This method is outlined and its efficacy is demonstrated with numerical simulation that is tested in real experiments conducted at the Advanced Photon Source to confirm its performance with a synchrotron beam. This work provides an opportunity to automate key instrumentation at X-ray facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-throughput homogenization of a quasi-Gaussian ultrafast laser beam using a combined refractive beam shaper and spatial light modulator

Efficiently shaping femtosecond, transverse Gaussian laser beams to flat-top beams with flat wavefronts is critical for large-scale material processing and manufacturing. Existing beam shaping devices fall short either in final beam homogeneity or efficiency. Here, we present an approach that uses refractive optics to perform the majority of the beam shaping and then uses a fine-tune device (spatial light modulator) to refine the intensity profile. For the beam that we selected, circularly asymmetric with intensity fluctuations, our method achieved a uniformity of 0.055 within 90% of the beam area at 92% efficiency. The optimization involved an iterative beam shaping process that converged to optimum within 10 iterations.

43 PARTICLE ACCELERATORS↗

Refractive Imaging of Air Shock Above Microscale Defects in Pentaerythritol Tetranitrate (PETN) Films

Physical vapor deposition (PVD) of high explosives can produce energetic samples with unique microstructure and morphology compared to traditional powder processing techniques, but challenges may exist in fabricating explosive films without defects. Deposition conditions and substrate material may promote microcracking and other defects in the explosive films. Here, we investigate effects of engineered microscale defects (gaps) on detonation propagation and failure for pentaerythritol tetranitrate (PETN) films using ultra-high-speed refractive imaging and hydrocode modelling. Observations of the air shock above the gap reveal significant instabilities during gap crossing and re-ignition.

36 MATERIALS SCIENCE↗

Interferometric measurements of refractive index and dispersion at high pressure

Abstract We describe a high precision interferometer system to measure the pressure dependence of the refractive index and its dispersion in the diamond anvil cell (DAC). The reflective Fabry–Perot fringe patterns created by both a white light and a monochromatic beam are recorded to determine both the sample thickness and its index at the laser wavelength and to characterize the dispersion in the visible range. Advances in sample preparation, optical setup, and data analysis enable us to achieve $$10^{-4}$$ 10 - 4 random uncertainty, demonstrated with an air sample, a factor of five improvement over the best previous DAC measurement. New data on $${\text{H}}_{2}\text{O}$$ H 2 O liquid water and ice VI up to 2.21 GPa at room temperature illustrate how higher precision measurements of the index and its optical dispersion open up new opportunities to reveal subtle changes in the electronic structure of water at high pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal transport in warm dense matter revealed by refraction-enhanced x-ray radiography with a deep-neural-network analysis

Abstract Transport properties of high energy density matter affect the evolution of many systems, ranging from the geodynamo in the Earth’s core, to hydrodynamic instability growth in inertial confinement fusion capsules. Large uncertainties of these properties are present in the warm dense matter regime where both plasma models and condensed matter models become invalid. To overcome this limit, we devise an experimental platform based on x-ray differential heating and time-resolved refraction-enhanced radiography coupled to a deep neural network. We retrieve the first measurement of thermal conductivity of CH and Be in the warm dense matter regime and compare our measurement with the most commonly adopted models. The discrepancies observed are related to the estimation of a correction term from electron-electron collisions. The results necessitate improvement of transport models in the warm dense matter regime and could impact the understanding of the implosion performance for inertial confinement fusion.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Imidazole-graphyne: a new 2D carbon nitride with a direct bandgap and strong IR refraction

Six-membered rings are common building blocks of many carbon structures. Recent studies have shown that penta-graphene composed of five-membered carbon rings have properties very different from that of graphene. This has motivated the search for new carbon structures. Among this is cp-graphyne, composed of carbon pentagons and bridged by acetylenic linkers. However, the bandgap of cp-graphyne, like that of graphene, is zero, making it unsuitable for applications in electronics. Herein, we show that a new two-dimensional (2D) carbon nitride structure formed by assembling the five-membered imidazole molecules with acetylenic linker can overcome this limitation. Named ID-GY, this new material not only has a direct band gap of 1.10 eV, but it is dynamically and mechanically stable and can withstand temperatures up to 1200 K. In addition, due to its porous and anisotropic geometry, the Young's modulus of ID-GY along the diagonal direction is lower than that of most 2D materials reported previously. Equally important, ID-GY exhibits strong refraction near infrared (IR) and has potential for applications in nanoelectronics and optical devices. These results, based on density functional theory, can stimulate experimental studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phase retrieval for refraction-enhanced x-ray radiography using a deep neural network

X-ray refraction-enhanced radiography (RER) or phase contrast imaging is widely used to study internal discontinuities within materials. The resulting radiograph captures both the decrease in intensity caused by material absorption along the x-ray path, as well as the phase shift, which is highly sensitive to gradients in density. A significant challenge lies in effectively analyzing the radiographs to decouple the intensity and phase information and accurately ascertain the density profile. Conventional algorithms often yield ambiguous and unrealistic results due to difficulties in including physical constraints and other relevant information. We have developed an algorithm that uses a deep neural network to address these issues and applied it to extract the detailed density profile from an experimental RER. To generalize the applicability of our algorithm, we have developed a technique that quantitatively evaluates the complexity of the phase retrieval process based on the characteristics of the sample and the configuration of the experiment. Accordingly, this evaluation aids in the selection of the neural network architecture for each specific case. Beyond RER, the model has potential applications for other diagnostics where phase retrieval analysis is required.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ray-tracing image simulations of transparent objects with complex shape and inhomogeneous refractive index

Optical images of transparent three-dimensional objects can be different from a replica of the object’s cross section in the image plane, due to refraction at the surface or in the body of the object. Simulations of the object’s image are thus needed for the visualization and validation of physical models. We report ray tracing image simulations that achieved high physical fidelity, reproducing optical behaviors and image features not rendered in previous studies. We replicated brightfield microscopy images of drops with complex shapes, and images of pressure and shock waves traveling inside them. For high physical fidelity, the simulations must replicate the spatial and angular distribution of illumination rays, and both the experiment and the simulation must be designed for accurate optical modeling. The simulations are highly sensitive to the properties of the drops and can be used to diagnose and refine fluid dynamics models. The simulated images can also be optimized to extract multiple 3D properties from experimental images. Compared to specialized single-shot 3D imaging methods, this approach has the advantage that it preserves the experimental simplicity, the high resolution, and the visual interpretability characteristic to basic optical imaging. The techniques introduced here are directly applicable to optical microscopy, so they can be used in other fields, such as microfluidics and biology, to expand the type and the accuracy of three-dimensional information that can be extracted from basic optical images.

Cavitation↗

Resonant nonlinear refraction of 4 – 5 - μ m light in CO and C O 2 gas

The resonant nonlinear refraction of 4–5-μm light in CO and CO 2 gas at a peak intensity of 15MW/cm 2 was demonstrated using time- and frequency-resolved measurements of self-focusing and self-defocusing. The nonlinearity of these molecular gases exhibits intensity-dependent sign reversals and a <4-ns response time. A change from self-focusing to self-defocusing or vice versa was observed to occur for Rabi frequencies that are comparable to the collisional linewidth. A density matrix model for the nonlinear susceptibility of a strongly driven two-level system provides a qualitative explanation for these results.

74 ATOMIC AND MOLECULAR PHYSICS↗

Negative Refraction in Time-Varying Strongly Coupled Plasmonic-Antenna–Epsilon-Near-Zero Systems

Time-varying metasurfaces are emerging as a powerful instrument for the dynamical control of the electromagnetic properties of a propagating wave. Here we demonstrate an efficient time-varying metasurface based on plasmonic nano-antennas strongly coupled to an epsilon-near-zero (ENZ) deeply subwavelength film. The plasmonic resonance of the metal resonators strongly interacts with the optical ENZ modes, providing a Rabi level spitting of ~30%. Optical pumping at frequency ω induces a nonlinear polarization oscillating at 2ω responsible for an efficient generation of a phase conjugate and a negative refracted beam with a conversion efficiency that is more than 4 orders of magnitude greater compared to the bare ENZ film. In this work, the introduction of a strongly coupled plasmonic system therefore provides a simple and effective route towards the implementation of ENZ physics at the nanoscale.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Refractive Guide Switching a Regenerative Amplifier Free-Electron Laser for High Peak and Average Power Hard X Rays

In this work, we present an x-ray regenerative amplifier free-electron laser design capable of producing fully coherent hard x-ray pulses across a broad tuning range at a high steady state repetition rate. The scheme leverages a strong undulator taper and an apertured diamond output-coupling cavity crystal to produce both high peak and average spectral brightness radiation that is 2 to 3 orders of magnitude greater than conventional single-pass self-amplified spontaneous emission free-electron laser amplifiers. Refractive guiding in the postsaturation regime is found to play a key role in passively controlling the stored cavity power. The scheme is explored both analytically and numerically in the context of the Linac Coherent Light Source II High Energy upgrade.

47 OTHER INSTRUMENTATION↗

Shock compression of diamond single crystals to 120 GPa: Refractive index and nonlinear photoelasticity

The optical response of transparent solids at extreme conditions is important for both fundamental science and many applications. Strong transparent solids are of particular interest for use as optical windows in dynamic compression experiments. Due to diamond’s exceptional strength and optical properties, laser-driven shock experiments and plate impact experiments were carried out to examine the diamond optical response for shock wave compression along two different crystal orientations. Using laser interferometry at 532 nm and 1550 nm wavelengths, optical transparency was observed and refractive indices were determined for [100] diamond at stresses up to 119 GPa and for [111] diamond at stresses up to 87 GPa. From these results, the nonlinear photoelastic response for [100] and [111] diamond was determined, revealing significant dependence on both crystal orientation and laser wavelength. To enable [100] diamond as an interferometry window in dynamic compression experiments, the requisite window corrections were determined for 532 nm and 1550 nm wavelengths. Because of diamond’s excellent x-ray transparency, the present findings will be particularly useful for incorporating [100] diamonds as windows in dynamic compression experiments involving x-ray diffraction or other x-ray diagnostics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Inserting a Low-Refractive-Index Dielectric Rear Reflector into PERC Cells: Challenges and Opportunities

One of the simplest and most effective ways to reduce the operating temperature of photovoltaic systems in the field is to reflect unusable, 'sub-bandgap' light with energies below the cell absorber's bandgap energy. In this work, low-refractive index SiO2 nanoparticle films inserted between c-Si wafers and metal electrodes significantly increase the reflectance of sub-bandgap light in fabricated test structures. These films are then integrated into the standard PERC fabrication sequence, revealing that the reflection benefits remains after some processing steps but are lost in certain conditions. The SiO2 nanoparticle films are easily ablated during laser contact opening, but are undesirably etched during post-laser cleaning. After Al metallization, the fully fabricated devices show enhanced sub-bandgap reflection when annealed at moderate temperatures, but energy-dispersive X-ray spectroscopy shows that high-temperature firing causes unwanted Al penetration into the SiO2 nanoparticle film, compromising reflection.

14 SOLAR ENERGY↗

Extension of Complex Refractive Index Measurements to the Near-Infrared for Liquids: Methodology and Uncertainty Analysis

Optical identification of liquid droplets, aerosols, or thin films is important for many applications. While reference spectra are sometimes available for such measurements, they are not always applicable to the observed spectrum or the given sample morphology. Reference spectra for many forms can be modeled, however, if the n/k vectors (real and imaginary refractive indices) are available. In previous work we have reported protocols to determine the n/k vectors for dozens of liquids, primarily in the mid-infrared (MIR) spectral range from 7500 to 400 cm –1 . In this work we extend the spectral range into the near-infrared (NIR) region, demonstrating a method to measure and merge the data sets to create composite n/k data ranging from 10 000 to 400 cm –1 (1.0 to 25 µm) with absorbance fidelity spanning over four orders of magnitude, and vastly improved signal-to-noise in the NIR. The precision of the composite data is evaluated for three different liquids, focusing primarily on the steps for converting the raw absorbance spectra to k values. The variability in both MIR and NIR data as well as in the final n/k vectors is also investigated for several liquids. For typical liquids, the overall variability (reported as 2σ) in the final n and k-vectors is determined to be ∼0.4% and 3%, respectively. Finally, the derived n/k data are used to calculate absorbance spectra for aerosol droplets, showing marginal variability due to the typical measurement errors in the final n/k vectors.

47 OTHER INSTRUMENTATION↗

Real-time measurement of parametric influences on the refractive index and length changes in silica optical fibers

In this paper, we present a simple cascaded Fabry-Perot interferometer (FPI) that can be used to measure in real-time the refractive index (RI) and length variation in silica optical fibers caused due to external physical parameters, such as temperature, strain, and radiation. As a proof-of-concept, we experimentally demonstrate real-time monitoring of temperature effects on the RI and length and measure the thermo-optic coefficient (TOC) and thermal expansion coefficient (TEC) by using the cascaded FPI within a temperature range of 21–486°C. The experimental results provide a TEC of 5.53 × 10 −7 /°C and TOC of 4.28 × 10 −6 /°C within the specified temperature range. Such a simple cascaded FPI structure will enable the design of optical sensors to correct for measurement errors by understanding the change in RI and length of optical fiber caused by environment parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Refractive axicon for X-ray microscopy applications: design, optimization, and experiment

In a full-field transmission X-ray microscopy (TXM) setup, a condenser X-ray optical element is used to illuminate the sample by condensing the X-ray beam delivered by the synchrotron storage ring. On-going and future upgrades of synchrotron facilities to diffraction-limited storage rings will pose new challenges to these TXM setups, such as much smaller X-ray beams on the condenser. Here, we demonstrate that a refractive axicon can be used as an X-ray beam shaper to match the ring-shaped aperture of the condenser. Aiming at more efficient use of the incoming X-ray intensity, we explore several axicon designs both analytically and with numerical simulations. The axicons were produced by two-photon polymerization 3D printing on thin silicon nitride membrane substrates. The first characterization of the axicon was carried out at the TOMCAT beamline of the Swiss Light Source (Switzerland).

47 OTHER INSTRUMENTATION↗

Nonlinear refraction and absorption properties of optical materials for high-peak-power long-wave-infrared lasers

Optical materials transparent in the CO 2 laser wavelength range have been evaluated regarding their suitability for components in ultrashort-pulse (≤ a few ps), high-peak-power (≥ a few TW) long-wave infrared (LWIR) lasers. We provide values for the nonlinear refractive index ( n 2 ) for seventeen materials, and onsets for nonlinear absorption for eleven materials. Characterizations were performed using a 2 ps laser pulse at λ =9.2 μ m. This paper methodically presents the newly acquired data in conjunction with existing literature on linear optical properties, establishing it as a comprehensive reference for designing high-peak-power LWIR laser systems.

43 PARTICLE ACCELERATORS↗

High speed laser-induced refractive index change in ophthalmic HEMA hydrogel using a line focus

Laser-induced refractive index change (LIRIC) techniques typically focus femtosecond laser pulses to a tight spot to achieve the high intensities required to alter ophthalmic materials. A line-focus implementation using 800 nm pulses at 1 kHz repetition rate has been shown to greatly increase the effective writing speed of the process, but the high pulse energies used led to nonlinear propagation effects, presenting challenges for the fabrication of ophthalmic correctors. By taking advantage of the lower effective order of multiphoton absorption for 514 nm pulses, power levels may be reduced, allowing overlapped pulse writing. We demonstrate that this allows high-quality phase bars and devices to be made at high speeds.

Manning, Zachary A. [University of Rochester, NY (↗