Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Radiation Exposure in Nonvascular Fluoroscopy-Guided Interventional Procedures

Purpose: To investigate the radiation exposure in non-vascular fluoroscopy guided interventions and to search strategies for dose reduction. Materials and Methods: Dose area product (DAP) of 638 consecutive non-vascular interventional procedures of one year were analyzed with respect to different types of interventions; gastrointestinal tract, biliary interventions, embolizations of tumors and hemorrhage. Data was analyzed with special focus on the fluoroscopy doses and frame doses. The third quartiles (Q3) of fluoroscopy dose values were defined in order to set a reference value for our in-hospital practice. Results: Mean fluoroscopy times of gastrostomy, jejunostomy, right and left sided percutaneous biliary drainage, chemoembolization of the liver and embolization due to various hemorrhages were 5.9, 8.6, 13.5, 16.6, 17.4 and 25.2 min, respectively. The respective Q3 total DAP were 52.9, 73.3, 155.1, 308.4, 428.6 and 529.3 Gy*cm{sup 2}. Overall, around 66% of the total DAP originated from the radiographic frames with only 34% of the total DAP applied by fluoroscopy (P < 0.001). The investigators experience had no significant impact on the total DAP applied, most likely since there was no stratification to intervention-complexity. Conclusion: To establish Diagnostic Reference Levels (DRLs), there is a need to establish a registry of radiation dose data for the most commonly performed procedures. Documentation of interventional procedures by fluoroscopy 'grabbing' has the potential to considerably reduce radiation dose applied and should be used instead of radiographic frames whenever possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Projector‐Based Quantum Embedding Study of Iron Complexes

Projection‐based embedding theory (PBET) is used to calculate and assess the challenging spin‐crossover energies for a selection of small Fe‐containing systems by embedding the metal center into the frozen potential of the ligands. MP2, CCSD, and CCSD(T) are embedded in potentials from the SCAN and r 2 SCAN functionals and compared with the canonical values for the constituent methods and previously reported reference values. Considering the PBET calculations as a correction for the underlying DFT, the embedding calculations are able to provided improvement for most cases. In some cases, the PBET methods are able to compensate for limitations in the wave function methods and produce results similar to more rigorous calculations from the literature. For the systems with spin‐crossover energies near zero, the current methodology fails to provide consistent improvement. In conclusion, the isolated recalculation of the electronic structure around the metal center when embedded into a DFT treatment of the ligand field shows promise as a pragmatic and lower cost treatment compared to the canonical treatment of the whole system of the difficult class of spin‐crossover complexes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Two and three-dimensional near infrared subcutaneous structure imager using realtime nonlinear video processing

A method includes placing an imaging device in contact with a sample, irradiating the sample via an illuminator such that radiation scatters off of the structure, and providing the scattered radiation to a detector to generate a digital video signal. A processor then performs various operations including subtracting a sum of a black state value and a user-defined black level clamping value from the digital video signal to create subtracted image data, substituting negative values in the subtracted image data with a reference value to create modified image data, and amplifying the modified image data by a user-defined gain to create contrast enhanced image data.

Krasowski, Michael J.↗

A subzone reconstruction algorithm for efficient staggered compatible remapping

Staggered-grid Lagrangian hydrodynamics algorithms frequently make use of subzonal discretization of state variables for the purposes of improved numerical accuracy, generality to unstructured meshes, and exact conservation of mass, momentum, and energy. For Arbitrary Lagrangian–Eulerian (ALE) methods using a geometric overlay, it is difficult to remap subzonal variables in an accurate and efficient manner due to the number of subzone–subzone intersections that must be computed. This becomes prohibitive in the case of 3D, unstructured, polyhedral meshes. A new procedure is outlined in this paper to avoid direct subzonal remapping. The new algorithm reconstructs the spatial profile of a subzonal variable using remapped zonal and nodal representations of the data. The reconstruction procedure is cast as an under-constrained optimization problem. Enforcing conservation at each zone and node on the remapped mesh provides the set of equality constraints; the objective function corresponds to a quadratic variation per subzone between the values to be reconstructed and a set of target reference values. Numerical results for various pure-remapping and hydrodynamics tests are provided. Ideas for extending the algorithm to staggered-grid radiation-hydrodynamics are discussed as well as ideas for generalizing the algorithm to include inequality constraints.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Methodology Used in the Radiological Assessment of a Coal-Fired Power Plant

A radiological assessment of the workers and the public potentially affected by the operation of the Teruel Coal-fired Power Plant (the UPT Teruel), was performed under realistic assumptions. This assessment is part of a wider study to characterize the potential radiological impact of Naturally Occurring Radioactive Materials (NORM), in which our team, integrated by University of Extremadura and CIEMAT, is carrying out the study on coal-fired power plants sponsored by the Spanish Nuclear Safety Council (CSN). The study comprises the four biggest coal-fired power plants in Spain. Taking into account the working conditions and the plant specifications, six groups of workers were defined, established considering the 17 working tasks that could be of any importance for this assessment. For the public, considering that the area is barely inhabited, two different recreational scenarios were defined. Therefore, in-plant and outside measurements, needed for the assessment of each scenario, were carried out. Where experimental data were not available or measurements ranged within the natural background radiation values, modelling has been used. Every measured or estimated activity concentration in coal and other used materials or in the by-products generated in the power plant, for every radionuclide in the natural chains of {sup 238}U, {sup 232}Th and {sup 40}K, were below 0.32 Bq g{sup -1}. Those values are under the 0.5 Bq g{sup -1} reference value for exemption and clearance of {sup 238}U, {sup 232}Th and {sup 226}Ra and the 5 Bq g{sup -1} for {sup 40}K recommended in Europe. In the dose evaluations for six groups of workers, a maximum of 21 {mu}Sv a{sup -1} was obtained (mainly due to the inhalation of resuspended particles). For both considered scenarios for the public, all the evaluated doses were below 4.3 {mu}Sv a{sup -1}. These results are considered negligible from a radiological point of view. In this work the models and assumptions used for the evaluation of workers and public doses, the assessment, as well as the most relevant experimental results and conclusions are presented.

54 ENVIRONMENTAL SCIENCES↗

Urinary trichloroacetic acid levels and semen quality: A hospital-based cross-sectional study in Wuhan, China

Toxicological studies indicate an association between exposure to disinfection by-products (DBPs) and impaired male reproductive health in animals. However, epidemiological evidence in humans is still limited. We conducted a hospital-based cross-sectional study to investigate the effect of exposure to DBPs on semen quality in humans. Between May 2008 and July 2008, we recruited 418 male partners in sub-fertile couples seeking infertility medical instruction or assisted reproduction services from the Tongji Hospital in Wuhan, China. Major semen parameters analyzed included sperm concentration, motility, and morphology. Exposure to DBPs was estimated by their urinary creatinine-adjusted trichloroacetic (TCAA) concentrations that were measured with the gas chromatography/electron capture detection method. We used linear regression to assess the relationship between exposure to DBPs and semen quality. According to the World Health Organization criteria (<20 million/mL for sperm concentration and <50% motile for sperm motility) and threshold value recommended by Guzick (<9% for sperm morphology), there were 265 men with all parameters at or above the reference values, 33 men below the reference sperm concentration, 151 men below the reference sperm motility, and 6 men below the reference sperm morphology. The mean (median) urinary creatinine-adjusted TCAA concentration was 9.2 (5.1) {mu}g/g creatinine. Linear regression analyses indicated no significant association of sperm concentration, sperm count, and sperm morphology with urinary TCAA levels. Compared with those in the lowest quartile of creatinine-adjusted urinary TCAA concentrations, subjects in the second and third quartiles had a decrease of 5.1% (95% CI: 0.6%, 9.7%) and 4.7% (95% CI: 0.2%, 9.2%) in percent motility, respectively. However, these associations were not significant after adjustment for age, abstinence time, and smoking status. The present study provides suggestive but inconclusive evidence of the relationship between decreased sperm motility and increased urinary TCAA levels. The effect of exposure to DBPs on human male reproductive health in Chinese populations still warrants further investigations. - Research highlights: {yields} No association between DBPs exposure and semen quality was found. {yields} Effects of DBPs exposure on male reproductive health need further investigations. {yields} Intra-individual variability of urinary TCAA should be considered in the future.

54 ENVIRONMENTAL SCIENCES↗

SU-E-T-343: Valencia Applicator Commissioning Using a Micro-Chamber Array

Purpose: In the commissioning and QA of surface isotope-based applicators, source-indexer distance (SID) has a great influence in the flatness, symmetry and output. To these purposes, methods described in the literature are the use of a special insert at the entrance of dwell chamber or radiochromic films. Here we present the experience with a micro-chamber array to perform the commissioning and QA of Valencia applicators. Methods: Valencia applicators have been used, the classic and the new extra-shielded version. A micro-chamber array has been employed, 1000 SRS (PTW), with 977 liquid filled, 2.3×2.3×0.5 mm{sup 3} sized ion chambers covering 11×11 cm{sup 2}, which spacing is 2.5 mm in the central 5.5×5.5 cm{sup 2}, dedicated mainly in principle, in conjunction with Octavius 4D (PTW), to IMRT, VMAT, SBRT verifications. Verisoft software that allows for 3D and planar analysis has been used to evaluate the results. Applicators were located on the surface of the array. To verify the SID, measurements corresponding to the reference value, SID ± 1 mm and SID ± 2 mm were acquired (integration time was fixed in order to discard the influence of the source entrance/exit). Once SID was determined, standard protocol treatments corresponding to 3 Gy and 7 Gy were acquired in order to establish typical patient dose distribution. Results: The method is fast and sensitive. The SID obtained was 1321 mm which is the nominal value included in the applicator manual. For example at 1319 mm an asymmetry of ±8% with respect to the central value was measured, along with a central deviation of −4% referred to 1321 mm. Conclusion: A practical method for the commissioning and QA of Valencia applicators has been described. It has been shown that it is an efficient and accurate tool for these purposes as well as for the verification of the absolute output constancy.

60 APPLIED LIFE SCIENCES↗

TU-C-BRE-03: Aggregation of Linac Measurement Data

Purpose: Accurate data of linear accelerator radiation characteristics is important for treatment planning system commissioning as well as regular quality assurance of the machine. The RPC has performed site visits of numerous machines . Data gathered from Varian machines from the past 15 years are presented. The data collected can be used as a secondary check or when commissioning a new machine to verify that values are reasonable. Methods: Data from the past 15 years of RPC site visits was compiled and analyzed. Data was composed from measurements from approximately 400 Varian machines. Each dataset consists of several point measurements at various locations in a water phantom to measure percentage depth dose, output factors, including small MLC fields, off-axis factors, and wedge factors if applicable. Common statistical values are presented for each machine type. Where applicable, data was compared to other reference data given by the vendor or a select number of previous researchers. Results: Data is separated by energy and parameter and then analyzed by machine class. Data distributions of the parameter data were normal except occasionally at the tails. Distributions of the data for each class and parameter are tabulated to give not simply a singular reference value, but metrics about the distribution: 5th and 95th percentile values and the standard deviation as well as the median. Conclusion: The RPC has collected numerous data on Varian linacs and presented the finding of the past 15 years. The data can be used as a reference data set for physicists to compare against. A linac that deviates from the values does not necessarily indicate there is a problem as long as the treatment planning system correlates to the machine. Comparison of linac and treatment planning system data to external reference data can prevent serious treatment errors.

07 ISOTOPE AND RADIATION SOURCES↗

Reference Data for the Density and Viscosity of Liquid Cadmium, Cobalt, Gallium, Indium, Mercury, Silicon, Thallium, and Zinc

The available experimental data for the density and viscosity of liquid cadmium, cobalt, gallium, indium, mercury, silicon, thallium, and zinc have been critically examined with the intention of establishing both a density and a viscosity standard. All experimental data have been categorized into primary and secondary data according to the quality of measurement, the technique employed and the presentation of the data, as specified by a series of criteria. The proposed standard reference correlations for the density of liquid cadmium, cobalt, gallium, indium, silicon, thallium, and zinc are characterized by percent deviations at the 95% confidence level of 0.6, 2.1, 0.4, 0.5, 2.2, 0.9, and 0.7, respectively. In the case of mercury, since density reference values already exist, no further work was carried out. The standard reference correlations for the viscosity of liquid cadmium, cobalt, gallium, indium, mercury, silicon, thallium, and zinc are characterized by percent deviations at the 95% confidence level of 9.4, 14.0, 13.5, 2.1, 7.3, 15.7, 5.1, and 9.3, respectively.

36 MATERIALS SCIENCE↗

Static and rotational output variation of a tomotherapy unit

A simple device to check the machine output in rotational mode is described. Integral and instantaneous beam output in absolute dose can be measured and analyzed in a very simple manner. A method to correlate the results with the value obtained during the machine calibration in static beam and the reference value used by the treatment planning system for dose calculation in rotation beam is also described. Using this method and device, the daily output can be performed in rotational conditions which are closer to the treatment conditions. Measurement results using this device show differences in the beam output between static and rotational delivery which have to be considered carefully during the calibration process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for Variations of {sup 213}Po Half-Life

A device with the parent {sup 229}Th source was constructed to search for variations of the daughter {sup 213}Po half-life (T{sub 1/2} = 4.2 μs). A solar-daily variation with amplitude A{sub So} = (5.3 ± 1.1) × 10{sup –4}, a lunar-daily variation with amplitude A{sub L} = (4.8 ± 2.1) × 10{sup –4}, and a sidereal-daily variation with amplitude A{sub S} = (4.2 ± 1.7) × 10{sup –4} were found upon proceeding the data series over a 622-day interval (from July 2015 to March 2017). The {sup 213}Po half-life mean value is found to be T{sub 1/2} = 3.705 ± 0.001 μs. The reference value is corrected by 12%.

07 ISOTOPE AND RADIATION SOURCES↗

Creating high-precision reference gas standards of 85Kr for groundwater age-dating

Absolute gas counting (AGC) was applied to two gas blends of 85Kr in argon-methane (P10) counting gas to establish a high-precision specific activity (Bq/cm3) reference value for characterizing 85Kr detection efficiency for groundwater age dating measurements. The AGC or length-compensated technique has been utilized by the metrology community for decades and is an accepted method for developing radioactive gas standards. The AGC capability at Pacific Northwest National Laboratory (PNNL) uses a set of nine unequal-length proportional counters with precisely-measured internal volumes, and a gas loading system with high-precision pressure and temperature sensors. A series of AGC measurements were collected at multiple pressures to determine the inverse pressure relationship (1/P) for 85Kr and define a wall-effect correction that accounts for events decaying into the detector wall and not depositing sufficient energy in the gas to be detected. In addition to the wall-effect, two additional corrections were evaluated and are discussed in detail. Specifically, the threshold effect which accounts for events deposited below the analysis threshold and a detection efficiency as a function of detector volume effect that was observed during analysis. A robust uncertainty model was developed using the Guide to the expression of Uncertainty in Measurements (GUM) approach. The combination of carefully scrutinized correction factors, precise measurements of pressure, temperature and detector volume, and robust counting statistics resulted in the determination of high-precision specific activity values with 0.50% or less total combined uncertainty for two Kr-in-P10 reference gas standards (KP10) that will enable new groundwater age-dating measurements at PNNL.

Kr-85↗

COLLISIONS BETWEEN GRAVITY-DOMINATED BODIES. I. OUTCOME REGIMES AND SCALING LAWS

Collisions are the core agent of planet formation. In this work, we derive an analytic description of the dynamical outcome for any collision between gravity-dominated bodies. We conduct high-resolution simulations of collisions between planetesimals; the results are used to isolate the effects of different impact parameters on collision outcome. During growth from planetesimals to planets, collision outcomes span multiple regimes: cratering, merging, disruption, super-catastrophic disruption, and hit-and-run events. We derive equations (scaling laws) to demarcate the transition between collision regimes and to describe the size and velocity distributions of the post-collision bodies. The scaling laws are used to calculate maps of collision outcomes as a function of mass ratio, impact angle, and impact velocity, and we discuss the implications of the probability of each collision regime during planet formation. Collision outcomes are described in terms of the impact conditions and the catastrophic disruption criteria, Q*{sub RD}-the specific energy required to disperse half the total colliding mass. All planet formation and collisional evolution studies have assumed that catastrophic disruption follows pure energy scaling; however, we find that catastrophic disruption follows nearly pure momentum scaling. As a result, Q*{sub RD} is strongly dependent on the impact velocity and projectile-to-target mass ratio in addition to the total mass and impact angle. To account for the impact angle, we derive the interacting mass fraction of the projectile; the outcome of a collision is dependent on the kinetic energy of the interacting mass rather than the kinetic energy of the total mass. We also introduce a new material parameter, c*, that defines the catastrophic disruption criteria between equal-mass bodies in units of the specific gravitational binding energy. For a diverse range of planetesimal compositions and internal structures, c* has a value of 5 {+-} 2; whereas for strengthless planets, we find c* = 1.9 {+-} 0.3. We refer to the catastrophic disruption criteria for equal-mass bodies as the principal disruption curve, which is used as the reference value in the calculation of Q*{sub RD} for any collision scenario. The analytic collision model presented in this work will significantly improve the physics of collisions in numerical simulations of planet formation and collisional evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Bias Estimates Used in Lieu of Validation of Fission Products and Minor Actinides in MCNP K eff Calculations for PWR Burnup Credit Casks

The U.S. Nuclear Regulatory Commission (NRC) Division of Spent Fuel Storage and Transportation recently issued Interim Staff Guidance (ISG) 8, Revision 3. This ISG provides guidance for burnup credit (BUC) analyses supporting transport and storage of PWR pressurized water reactor (PWR) fuel in casks. Revision 3 includes guidance for addressing validation of criticality (k eff ) calculations crediting the presence of a limited set of fission products and minor actinides (FP&MA). Based on previous work documented in NUREG/CR-7109, recommendation 4 of ISG-8, Rev. 3, includes a recommendation to use 1.5 or 3% of the FP&MA worth to conservatively cover the bias due to the specified FP&MAs. This bias is supplementary to the bias and bias uncertainty resulting from validation of k eff calculations for the major actinides in SNF and does not address extension to actinides and fission products beyond those identified herein. The work described in this report involves comparison of FP&MA worths calculated using SCALE and MCNP with ENDF/B-V, -VI, and -VII based nuclear data and supports use of the 1.5% FP&MA worth bias when either SCALE or MCNP codes are used for criticality calculations, provided the other conditions of the recommendation 4 are met. The method used in this report may also be applied to demonstrate the applicability of the 1.5% FP&MA worth bias to other codes using ENDF/B V, VI or VII based nuclear data. The method involves use of the applicant s computational method to generate FP&MA worths for a reference SNF cask model using specified spent fuel compositions. The applicant s FP&MA worths are then compared to reference values provided in this report. The applicants FP&MA worths should not exceed the reference results by more than 1.5% of the reference FP&MA worths.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluating the effect of sample type on American alligator ( Alligator mississippiensis ) analyte values in a point-of-care blood analyser

The assessment of wildlife health has been enhanced by the ability of point-of-care (POC) blood analysers to provide biochemical analyses of non-domesticated animals in the field. However, environmental limitations (e.g. temperature, atmospheric humidity and rain) and lack of reference values may inhibit researchers from using such a device with certain wildlife species. Evaluating the use of alternative sample types, such as plasma, in a POC device may afford researchers the opportunity to delay sample analysis and the ability to use banked samples. In this study, we examined fresh whole blood, fresh plasma and frozen plasma (sample type) pH, partial pressure of carbon dioxide (PCO 2 ), bicarbonate (HCO 3 ₋), total carbon dioxide (TCO 2 ), base excess (BE), partial pressure of oxygen (PO 2 ), oxygen saturation (sO 2 ) and lactate concentrations in 23 juvenile American alligators (Alligator mississippiensis) using an i-STAT CG4+ cartridge. Our results indicate that sample type had no effect on lactate concentration values (F 2,65 = 0.37, P = 0.963), suggesting that the i-STAT analyser can be used reliably to quantify lactate concentrations in fresh and frozen plasma samples. In contrast, the other seven blood parameters measured by the CG4+ cartridge were significantly affected by sample type. In conclusion, we were able to collect blood samples from all alligators within 2 min of capture to establish preliminary reference ranges for juvenile alligators based on values obtained using fresh whole blood.

60 APPLIED LIFE SCIENCES↗

Comparison Calculations of Subcritical Limits in ANSI/ANS-8.1 [Slides]

The calculations presented in this paper were performed with ENDF/B-VIII.0 and SCALE 6.3.1 to provide users with perspective on what the current k eff values are for the SCLs listed in ANS-8.1. There are multiple SCLs that exceed the reference value of 0.98. This may indicate that these values need to be adjusted by the WG for the next iteration of the standard.

ENDF↗

Quantum-cascade-laser-absorption-spectroscopy diagnostic for temperature, pressure, and NO X 2 Π 1/2 at 500 kHz in shock-heated air at elevated pressures

The design, validation, and application of a quantum-cascade-laser-absorption-spectroscopy diagnostic for measuring gas temperature, pressure, and nitric oxide (NO) in high-temperature air are presented. A distributed-feedback quantum-cascade laser (QCL) centered near 1976 c m − <#comment/> 1 was used to scan across two transitions of NO in its ground electronic state ( X 2 Π <#comment/> 1 / 2 ). A measurement rate of 500 kHz was achieved using a single QCL by: (1) performing current modulation through a bias-tee, and (2) targeting closely spaced transitions with a large difference in lower-state energy. The diagnostic was validated in a mixture of 95% argon and 5% NO, which was shock-heated to ≈ <#comment/> 2000 to 3700 K. The average mean percent differences between laser-absorption-spectroscopy (LAS) measurements and predictions from shock-jump relations for temperature, pressure, and NO mole fraction were 3.1%, 4.1%, and 6.5%, respectively. The diagnostic was then applied to characterize shock-heated air at high temperatures (up to ≈ <#comment/> 5500 K ) and high pressures (up to 12 atm) behind either incident or reflected shocks. The LAS measurements were compared to theoretical predictions from shock-jump relations, pressure sensors mounted in the wall of the shock tube, and equilibrium values of the NO mole fraction. The average mean percent differences between LAS measurements and their aforementioned reference values were 3.2%, 10.8%, and 10.4% for temperature, pressure, and NO mole fraction, respectively. Last, a comparison between a measured NO mole fraction time history and a time-stepped homogeneous reactor simulation performed using two different chemical kinetics mechanisms is presented.

Gilvey, Jonathan J. (ORCID:0000000317664383)↗

Core Concepts for a 3000MW th Advanced Burner Reactor

The impacts of increasing power on Advanced Burner Reactor (ABR) core performance were evaluated by increasing the power level from a reference value of 1000 MWth to 3000 MWth. By targeting comparable core performance characteristics and sodium void worth as the reference 1000 MWth ABR core concepts, 3000 MWth ABR core concepts were developed with ternary metal and mixed oxide fuels. A sensitivity study indicates that sodium void worth of a large ABR core could be reduced by deceasing core height or/and increasing the power density. Thus, core height was determined such that the core was reasonably tall to minimize core diameter, but short enough to meet the assumed sodium void worth limit of ~6$. Other design parameters such as fuel volume fraction, TRU enrichment, and number of driver assemblies were determined to achieve the targeted TRU conversion ratio and cycle length. Key design parameters and core performance parameters are provided in Table 0.1. The 3000 MWth ABR core consists of 594 drivers divided into three different enrichment zones to achieve a flat power distribution. The active core heights are 60 cm and 92 cm for the metal and oxide cores with fuel volume fractions of 31.6% and 37.9%, respectively. Cycle length was determined to be 15 months for the metal core and 18 months for the oxide core with a capacity factor of 90%. Three- and four-batch fuel management schemes were employed for the metal and oxide cores, respectively. As a result, the fuel residence time became 45 months for the metal core and 72 months for the oxide core.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗