Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Raven”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Digital Twin Development for Real Time Optimization

In the real-time optimization operation process of the integrated energy system, digital twin (DT) can support operators to find optimal dispatching strategy. In this research, the DT framework interfacing (external) system-level simulation model, RAVEN, and Python-based optimization framework has been developed. Simple demonstration of finding optimal input values minimizing an objective function with the DT framework has been presented.

25 ENERGY STORAGE↗

Digital Twin for Optimizing Real-time Economy of the Integrated Energy Systems

Economic and safe operation of integrated energy systems (IES) requires real-time optimization (RTO) of the control and actions conducted on each system component. In this regard, digital twins (DTs), which consist of a physical system, a virtual system, and the data communication that occurs between the two, are essential for effective RTO. Through the data warehouse, the virtual system is constantly updated with real-time data from the physical system, and functions as the model in the optimization framework. The reduced-order model of the dynamic process model in the virtual system is used in the optimization framework. The optimization results are then returned, via the data warehouse, as control actions to the physical system. This work demonstrates the software capabilities of DT assets for an IES in the context of preparing a DT for an experimental system comprised of Idaho National Laboratory (INL)’s Thermal Energy Delivery System and battery system. For the virtual demonstration, the DTs encompass (1) a physical system, including the Modelica models of the Thermal Energy Delivery System and the battery system; (2) virtual optimization via the Optimization of Real-Time Capacity Allocation (ORCA) platform; and (3) the open-source data warehouse software DeepLynx. This work assesses the performance of ORCA, which utilizes a reduced-order model built using the Risk Analysis Virtual Environment (RAVEN) and trained on the Modelica models and real-time data pipeline through the graph database hosted in DeepLynx. The proposed optimization workflow will be an RTO model based on DTs and the data they generate.

25 ENERGY STORAGE↗

Pressurized-Water Reactor Core Design using Multi-Objective Plant Fuel Reload Optimization Platform

The United States (U.S.) Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) Program Risk-Informed Systems Analysis (RISA) Pathway Plant Reload Optimization Project aims to develop an integrated, comprehensive framework offering an all-in-one solution for reload evaluations with a special focus on optimization of core design. The optimization of the fuel loading pattern is one of the most important considerations in reducing the amount of new fuel used in the core. Due to thousands of possible options of core configuration, finding optimal solutions is an unachievable task for a human. The Plant ReLoad Optimization (PRLO) platform which supports artificial-intelligence-based reactor core designing is now fully capable of handling realistic problems. The PRLO Platform development project aims to build a reactor core design tool that includes reactor safety and fuel performance analyses and uses artificial intelligence to support the optimization of core design solutions. The NSGA-II (Non-dominated Sorting Genetic Algorithm-II) optimizer was developed and tested within RAVEN (Risk Analysis and Virtual Environment) to handle many constraints by using an augmented objectives methodology. The demonstration was performed with constrained multi-objective optimization of a 17 × 17 pressurized-water reactor core loading patterns to minimize fuel cost and maximize fuel cycle length.

42 ENGINEERING↗

Risk-based area of review estimation in overpressured reservoirs to support injection well storage facility permit requirements for CO 2 storage projects

This paper by the Energy & Environmental Research Center presents a workflow and modeling approach for delineating a risk-based area of review (AOR) to support a U.S. Environmental Protection Agency (EPA) Class VI permit for a carbon dioxide (CO 2 ) storage project. The approach combines semianalytical solutions for estimating formation fluid leakage through a hypothetical leaky wellbore with the results of numerical reservoir simulations to define the AOR. The modeling utilizes 1) semianalytical solutions from the peer-reviewed literature for formation fluid leakage through abandoned wellbores by Raven (1990) and Avci (1994), 2) a FORTRAN model compiled and described in Cihan et al. (2011, 2012) called ASLMA (Analytical Solution for Leakage in Multilayered Aquifers), and 3) a computational framework for estimating a risk-based AOR first proposed by Oldenburg et al. (2014, 2016). Therefore, the approach builds upon well-established research and underlying hydrogeological principles that have been upheld for nearly three decades. Moreover, the ASLMA model has been broadly applied to an array of storage projects. The work presented herein extends these earlier works using a custom wrapper written in the software environment, R (R Core Team, 2020), which was developed to perform multiple runs of the ASLMA model using given ranges for one or more input parameters. In addition, the current work simulates the pressure buildup within the storage reservoir in response to CO 2 injection using a compositional simulator to better accommodate the temporospatial evolution of pressure buildup within the storage reservoir that is more accurately modeled using a heterogeneous geologic model and a compositional simulator that accounts for the multiphase interactions. The workflow is demonstrated using a case study for a 180,000-metric-ton-per-year storage project located in the PCOR (Plains CO 2 Reduction) Partnership region. For the storage project evaluated here, under the scenario where the leaky wellbore is open to a saline aquifer (thief zone) between the overlying seal (cap rock) and the underground sources of drinking water (USDW), the risk-based AOR essentially collapses to the areal extent of the CO 2 plume in the storage reservoir because the pressure buildup in the storage reservoir beyond the CO 2 plume is insufficient to drive formation fluids up a hypothetical leaky wellbore into the USDW. However, even under the conservative assumption that the leaky wellbore is not open to a thief zone, beyond the areal extent of the CO 2 plume, the incremental leakage is less than 400 m 3 over 20 years, which represents ~0.0001% or less of the total volume of water contained within the USDW rock volume. As discussed in the text, the threshold criterion for defining the risk-based AOR is site-specific and should be informed by the results of the sensitivity analysis and available site characterization data. The approach outlined in this paper is designed to be protective of USDWs and, therefore, comply with the Safe Drinking Water Act requirements and provisions for the U.S. EPA Class VI Underground Injection Control (UIC) Program (Class VI Rule) and North Dakota Administrative Code Chapter 43-05-01.

54 ENVIRONMENTAL SCIENCES↗

RELAP5-3D validation studies based on the High Temperature Test facility

In the spring and summer of 2019, experiments were conducted at the High Temperature Test Facility (HTTF) that form the basis of an upcoming high-temperature gas-cooled reactor (HTGR) thermal hydraulics (T/H) benchmark. HTTF is an integral effects test facility for HTGR T/H modeling validation. This paper presents RELAP5-3D models of two of those experiments: PG-27, a pressurized conduction cooldown (PCC); and PG-29, a depressurized conduction cooldown (DCC). These models used the RELAP5-3D model of HTTF originally developed by Paul Bayless as a starting point. The sensitivity analysis and uncertainty quantification code, RAVEN was used to perform calibration studies for the steady-state portion of PG-27. Here we developed four PG-27 calibrations based on steady-state conditions. These calibrations all used an effective thermal conductivity equal to 36 % of the measured thermal conductivity, but they differed with respect to the frictional pressure drops and radial conduction models. These models all captured the trends in steady-state temperature distributions and transient temperature behavior well. All four calibrations show room for improvement in predicting the transient temperature rise. The smallest error in temperature rise during the transient was a 21 % underprediction, and the largest was a 48 % underprediction. The errors in transient temperature rise are largely a result of a mismatch in power density between the RELAP5-3D model and the experiment due to the location of active heater rods along the boundary between heat structures in the model. The best of these calibrations was applied to PG-29 to model the DCC. Once again, temperatures during the transient were underpredicted but trends in temperature were captured. The RELAP5-3D model captured trends in the data but could not reproduce measured temperatures exactly. This result is not attributed to deficiencies in the experimental data or to RELAP5–3D itself. Rather, this result likely arises due to the some of the assumptions and decisions made when the RELAP5-3D model was first developed, prior to the execution of HTTF experiments. An agreement in prediction of temperature trends but challenges reproducing HTTF temperatures within measurement uncertainty is consistent with previous analyses of HTTF in the literature. Future RELAP5-3D validation activities centered around HTTF may be able to provide greater insight into the code’s capabilities for HTGR modeling with a more finely nodalized model.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sensitivity Analysis of Transient Critical Heat Flux by RIA Under High-Pressure Flow Boiling Conditions in TRTL

A reactivity-initiated accident (RIA) is a design-basis accident under which critical heat flux (CHF) is likely to be exceeded. The operational margin for RIAs is currently determined using steady-state CHF lookup tables, which provide conservative estimates relative to transient CHF phenomena. The Transient Reactor Test Loop (TRTL) facility at Oregon State University is capable of performing out-of-pile rapid heating experiments representative of a RIA at conditions representative of a pressurized water reactor (PWR). Here, to further our understanding of and ability to predict transient CHF under PWR conditions, we performed a sensitivity analysis on a RELAP5-3D model of the TRTL facility coupled to the RAVEN code framework to define a proposed experimental test matrix to be performed at the TRTL facility. We then implemented a flow boiling CHF correlation into RELAP5-3D and performed a secondary sensitivity analysis inspecting the impact of the built-in RELAP5-3D CHF and heat transfer multipliers on both the prediction of CHF and key safety parameters, such as peak cladding temperature and heat flux. The results show that the multiplier with the highest influence toward the prediction of CHF occurrence and the safety parameters is the transient CHF multiplier. Operational performance envelopes have been developed for each of the test matrix cases and will be used for validation once the experiments are performed. The TRTL facility is currently performing shakedown testing to verify system performance prior to proceeding with the experimental campaign. Restart testing results include pump curve restart testing, pressure tests, and heater rod thermocouple transients.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

TRISO SiC Failure Probability for Reactivity Initiated Accidents in High-Temperature Gas-Cooled Reactors

This work analyzes the failure process of the silicon carbide (SiC) layer in tristructural isotropic (TRISO) during reactivity-initiated accident scenarios for a high-temperature gas-cooled reactor (HTGR) with BISON. Two cases are considered—a group control rod withdrawal (CRW) and a control rod ejection (CRE)—reproduced from a previous study. Failure probability is modeled using Weibull statistics, and worst-case scenario Weibull parameters are adopted to simulate the envelopes in BISON with a one-dimensional TRISO model. CRW scenario results are characterized by higher values of maximum energy deposition and final temperature and volumetric strain with respect to the CRE ones, but the latter have remarkably higher SiC failure probability, mainly due to the offset in strain rates between the two cases. This work also confirms the validity and conservatism of the performance envelopes produced in a previous work by replicating the envelope formulation using RELAP5-3D and RAVEN with a different sampling technique and obtaining consistent results. A sensitivity analysis using the Sobol variance decomposition method on SiC failure probability is then performed involving a set of inputs on both CRW and CRE. The two most important parameters are Weibull modulus and characteristic stress, and their relative importance depends on the specific case. The proposed interpretation of the results is that both energy deposition and strain rate influence the relative degree of importance of the failure parameters. Computation of 95% confidence intervals around worst-case scenario SiC failure probability values is also carried out for four different sets of Weibull parameters. Heren a new criterion for SiC TRISO quality classification built upon safety-based ranges of Weibull parameters is proposed to be integrated in future Fuel-Production Quality Assurance Plans.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

LOGOS

LOGOS is a software package which contains a set of discrete optimization models that can be employed for capital budgeting optimization problems. More specifically, provided a set of items (characterized by cost and reward values) and constraints, these models select the best combination of items which maximizes overall reward and satisfies the provided constraints. The developed models are based on different versions of the knapsack optimization algorithms. Two main classes of optimization models have been initially developed: deterministic and stochastic. Stochastic optimization models evolve deterministic models by explicitly considering data uncertainties (associated to constraints or item cost and reward). These models can be employed as stand-alone models or interfaced with the INL developed RAVEN code to propagate data uncertainties and analyze the generated data (i.e., sensitivity analysis).

Wang, Congjian↗

Optimization Of Real-time Capacity Allocation

ORCA is a modeling toolset to accelerate real-time control and optimization of digital twins, including virtual models of facilities, physical facilities, and interconnections to allow optimal control of physical facilities using virtual models. ORCA is enabled by INL's RAVEN and DeepLynx software codes.

Talbot, Paul [Idaho National Laboratory] (00000002↗

lanl-ansi/MG-RAVENS

The MG-RAVENS project with the DOE Office of Electricity Microgrid R&D Program is a project to develop a completely free, open-source data exchange standard (API) for the Department of Energy, targeted at software tools related to infrastructure modeling, particularly the modeling of microgrids and electric power distribution systems that are created with funding from the Microgrid R&D Program. This software produces formal definitions of an API, documentation, contains supporting functions for parsing, validating, etc., and will contain examples of workflows enabled by the developed API.

Fobes, David M↗

Plant Reload Optimization (prlo)

The PRLO framework is built on a modular and extensible architecture that tightly couples advanced evolutionary optimization algorithms with nuclear fuel depletion solvers (i.e., nuclear physics neutronics code). It supports exploring complex, high-dimensional design spaces constrained by user-specified operational, safety, and economic constraints. Objectives such as minimizing fresh fuel enrichment, flattening radial and axial power distributions, and maximizing discharge burnup are evaluated. PRLO’s equilibrium cycle optimization capability enables the identification of core configurations that maintain fuel cycle sustainability over extended planning horizons. Its integration with the RAVEN platform facilitates optimization of loading patterns or fuel shuffling schemes across multiple cycles. The interface with SIMULATE, a licensed industry-standard nodal code developed by Studsvik, ensures accurate neutronic and thermal-hydraulic feedback for reactor core design. PRLO’s automated workflow engine supports iterative design refinement, enabling utilities to streamline core design processes and meet evolving performance and regulatory targets.

Kim, Junyung [Idaho National Laboratory] (00090005↗

Risk Importance Ranking of Fire Data Parameters to Enhance Fire PRA Model Realism

Fire is historically and analytically a significant contributor to nuclear power plant risk. The level of fire risk and the methods, tools and data for modeling this risk is highly debated by experts. One area of debate is the input data used in fire modeling and how to deal with this data’s high uncertainty. This report outlines initial work performed for determining the key parameters causing this uncertainty and how it propagates into nuclear power plant models. This research paves the way for the development of methods to reduce fire data uncertainty used in modeling. The Nuclear Regulatory Commission has mandated that nuclear power plants perform fire risk modeling. However, there are several issues with the current risk modeling implementation that affect the results. Approved modeling methods can be overly conservative and often do not match plant experience. Also, the data used in the modeling can have high uncertainties and is influenced by expert judgement. To evaluate input data uncertainty, researchers performed an initial review of several fire experiments done at Sandia National Laboratories. Uncertainties for fire data can come from many sources, such as experiment design constraints, environmental conditions, or other plant-specific aspects. There are many different significant and insignificant parameters driving the uncertainty. Additionally, the uncertainty of the different input data used in the fire modeling could have a significant or insignificant effect on the entire plant risk. A four-step methodology was developed to perform Integrated Probabilistic Risk Assessment Importance Ranking. A demonstration case using these steps was set up and three of the four steps were completed in fiscal year (FY) 2019 and the fourth step done FY 2020. These steps are: 1. The qualitative analysis of potential sources was conducted with the following items identified for the demonstration. • Maximum heat release rate • Time to maximum heat release rate • Duration of max heat release rate • Time to decay • Thermal conductivity of concrete • Specific heat of concrete • Density of concrete • Cable jacket thickness 2. A quantitative characterization of dominant sources of uncertainty was performed. A list of distributions and determined values of the dominant sources is shown in Appendix A. 3. A quantitative screening of the potential sources of uncertainty using Morris Elementary Effects Analysis was completed. An experimental model using the physics-based fire modeling tool Fire Dynamics Simulator was developed and coupled with the Risk Analysis Virtual Environment. The Morris analysis identified at least two parameters that can be eliminated as significant contributors (specific heat of concrete and cable jacket thickness). 4. Global importance measure (Global IM) analysis to generate a comprehensive ranking based on their influence on the plant risk. In this research, a moment-independent Global IM is used since it can address (a) uncertainty in the input parameters of the fire model, (b) uncertainty in the risk outputs, and (c) non-linearity and interactions among input parameters in the fire model, more accurately than the correlation-based and variance-based global methods. The observations from the research showed that, depending on the initial and boundary conditions of the fire scenarios, fire-induced damage could have a very small probability and could be dominated by the tail of the uncertainty distribution; hence, the accuracy of the correlation-based and variance-based methods is questionable. The moment-independent Global IM analysis in this research provides a better understanding of how experimental uncertainty data affects industry’s plant models and where improvements in that data will have the largest benefit for improving fire modeling accuracy in causing core damage. Among the five unscreened parameters obtained from the Morris EE analysis, the Global IM analysis results for the case study indicated that max heat release rate and fire location are the most important parameters. The report also outlines benefits of using a unified computational platform that integrates the underlying simulations (e.g., a fire progression model), quantitative screening (using the Morris EE method), and the Global IM analysis. A unified platform can (i) facilitate the ranking of input parameters considering multiple key fire scenarios simultaneously, rather than considering one scenario at a time, (ii) contribute to more explicit and accurate treatment of dependencies at multiple levels of Fire PRA, (iii) facilitate the sampling-based uncertainty quantification for Fire PRA, and (iv) help generating both “industry-wide” and "plant-specific" ranking of uncertainty sources in Fire PRA. Future research should be done to include additional parameters such as detection/suppression or cable fire spread. Adding a PRA software such as SAPHIRE to the RAVEN platform would help with plant model integration and improve treatment of fire-induced dependency. The I-PRA risk importance ranking methodology offered in this report can provide valuable information for efficiently (a) enhancing the realism of Fire PRA for existing plants and (b) supporting the development of Dynamic Fire PRA for advanced reactors and new plants.

97 MATHEMATICS AND COMPUTING↗

Integrating static PRA information with risk informed safety margin characterization (RISMC) simulation methods

The overall objective of the project was to develop a computationally feasible and user-friendly mechanized process to integrate traditional probabilistic risk assessment (PRA) and dynamic PRA (DPRA) results. Starting with the systematic identification of items in an existing PRA that need dynamic augmentation, the project used a generic 4-loop pressurized reactor (PWR) and 3-loop PWR as example plants. Station blackout (SBO) and large break loss of coolant accident SBLOCA) were selected as the example initiating events. Using the traditional event-tree (ET)/fault-tree (FT) methodology augmented by dynamic evet tree approach, the potential consequences of the initiating events were simulated with RELAP-3D and MELCOR/RASCAL codes to cover Level 1 through Level 3 of PRA. RAVEN and ADAPT software were used to generate Level 1 simulations with RELAP-3D and Level 2/3 simulations with MELCOR (Level 2)/RASCAL (Level 3), respectively. Example branching conditions (BCs) for SBO included AC power recovery time, valve repair failure time, reactor coolant pump leak time/break size and emergency power supply duration to a total of 9. Example BCs for LOCA included off-site power recovery time, diesel generator power recovery time, auxiliary feed water system operation time, safety relief valve failure to open upon demand, reactor coolant pump seal break time and size to a total of 21. Each RELAP-3D simulation (9,587 scenarios) was labelled OK or Core Damage based on the maximum allowed peak clad temperature (2,100oF). Each MELCOR simulation (4610 scenarios) was labeled as Bin over 10rem or Bin 0-10rem based on the dose at the site boundary. The scenarios were clustered based on the criteria above using the mean shift methodology. Classical PRA (CPRA) and DPRA results were compared to identify the ET sequences that need DPRA augmentation. Several approaches were proposed for the incorporation of these sequences into CPRA using clustering with the mean shift methodology, restructuring the CPRA ETs by adding new BCs/sequences, and using the concept of a limit surface. Procedures for decision making regarding the possible consequences of an initiating event (e.g. core damage or not, site evacuation or not) were developed using a convolutional neural network (CNN), a recurrent neural network (RNN) and a transformer neural network (TNN). The project has led to two PhD degrees, three archival journal papers and five refereed conference proceedings.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Release a public version of HERON (HERON 2.0) with improved algorithms for the treatment of energy storage

Integrated energy systems (IESs) are essential for decarbonizing electricity and industrial sectors and fully exploiting these systems requires sophisticated planning, scheduling, and dispatching tools to maximize their socio-economic benefits. The Holistic Energy Resource Optimization Network (HERON) is a generic software plugin for the Risk Analysis Virtual Environment (RAVEN) to perform stochastic technoeconomic analysis of IES with economic drivers. This report summarizes the updates made to HERON 2.0. Particularly, we demonstrate one of the added features, Function-based Control Mechanics, by comparing a price-based dispatch strategy with the original perfect foresight baselines. Our case studies successfully demonstrate that the model is capable to incorporate artificial control algorithm into the dispatch of IES components. In addition, our results from the price-based strategy indicate that the control strategies of IES components are key to the economic and temporal performance of our model; therefore, more sophisticated dispatch strategies are required to improve the model performance.

25 ENERGY STORAGE↗

Time dependent supervisory control update with FARM using rolling window

This report describes improvements to the Feasible Actuator Range Modifier (FARM) component of the RAVEN-based HYBRID framework for analysis of Integrated Energy Systems (IES). FARM supports the HERON plug-in that solves the power dispatch problem. The solution to the dispatch problem involves economically optimal dispatches that satisfy limits on production variables and their rates of variation (explicit constraints) as well as process variables tied to the service life of equipment (implicit constraints). FARM serves to validate or confirm that a HERON solution for explicit constraints also satisfies the implicit constraints. FARM-alpha was released by Argonne National Laboratory in January 2021 followed by FARM-Beta in January 2022 with the latter providing increased flexibility for the user. In this report, FARM-Gamma, the latest version of the code, is described. The major improvement is the implementation of a system identification algorithm based on the Dynamic Mode Decomposition with Control (DMDc) coupled with a “Rolling Window” scheme that allows obtaining linear time-varying state-space models. This feature equips FARM with the most accurate approximation of system dynamics, and it relieves the user from the burden of performing an exhaustive off-line characterization of the dynamics. FARM-Gamma capabilities are assessed by solving the power dispatch problem for a representative IES unit. The simulation times corresponding to the different releases are estimated and compared. These values capture the increasing computational burden of the successively higher fidelity state-space models adopted by FARM-Alpha, FARM-Beta and FARM-Gamma. The code implementation provides significant flexibility, i.e., the user can always select the most suitable version of FARM according to the problem to be solved and the available computational resources. It is anticipated that FARM will play a role in addressing several future IES applications. We outline how it can support the coordinated management and safe operation of a nuclear plant coupled to industrial processes to produce hydrogen and synfuels.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Control system for multi-system coordination via a single reference governor

This report describes the improvements to the Feasible Actuator Range Modifier (FARM) component of the RAVEN-based HYBRID framework for analysis of Integrated Energy Systems (IES). FARM supports the HERON plug-in that solves the power dispatch problem. The solution involves economically optimal dispatches that satisfy the limits on production variables and corresponding rates of variation (explicit constraints) as well as the limits on the process variables tied to the service life of equipment (implicit constraints). The problem can be addressed as a two-stage process, i.e., HERON power dispatcher estimates a solution that meets explicit constraints (low-resolution physics), whereas FARM uses the simulation outcomes of HYBRID high-fidelity model to capture the system dynamic response and enforce implicit constraints (high-resolution physics). The initial version of the code (FARM-Alpha) was released by Argonne National Laboratory in January 2021 followed by FARM-Beta (January 2022) and FARM-Gamma (April 2022).

42 ENGINEERING↗

Synthetic Electricity Market Data Generation and HERON Use Case Setup of Advanced Nuclear Reactors Coupled with Thermal Energy Storage Systems

This study evaluates and optimizes advanced nuclear reactors coupled with thermal energy storage (TES) systems in an Integrated Energy System (IES) architecture to enable advanced nuclear power plants (A NPP) to participate in multi-commodity markets, thus enhancing their economic competitiveness. Nuclear-TES coupling scenarios studied herein are designed attenuate the nuclear heat dynamics and defer energy delivery to a later time, enabling the nuclear reactor to continue operating at or near steady-state design conditions as usual while also enabling flexible generation. Three A-NPPs, namely, an advanced light-water reactor (A LWR), a high temperature gas-cooled reactor (HTGR) and a liquid-metal fast reactor (LMFR) were selected as the initial use cases for demonstrating the technoeconomic of thermally balanced energy storage coupling design for thermal power extraction. Each of the reactor technologies were evaluated in two different electricity markets. Stochastic optimization approach was adopted which included the evaluation of price signals from the Pennsylvania-New Jersey-Maryland (PJM) market, and Electric Reliability Council of Texas (ERCOT), using an autoregressive moving average (ARMA) model. Risk Analysis Virtual Environment (RAVEN) tool and its dispatch optimization plugin, the Holistic Energy Resource Optimization Network (HERON), were used to perform dispatch and capacity optimization, using the price data provided by the ARMA models. The results from the Nuclear-TES use cases will be used to design and characterize dynamic integrated system behavior and feedback.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Implementation of a feature selection algorithm in FARM to identify important state variables and time-invariant matrices

The FARM (Feasible Actuator Range Modifier) software module is a component of the RAVEN-based FORCE framework for analysis of Integrated Energy Systems (IES). FARM aids the HERON software module in the evaluation of the optimal dispatch for the different IES components. Set-point trajectories are required to meet limits on both production variables (i.e., the variables to be optimized such as the electrical power, the hydrogen production rate, etc.) and process variables tied to the service life of equipment (e.g., steam flowrate, vessel pressure, turbine firing temperature, etc.). To evaluate the feasibility of HERON generated set-points and to do so in an acceptable time, FARM employs reduced order models to represent the dynamic behavior of the systems to be dispatched. These surrogate models take the form of a linear dynamic system with sets of Linear Parameter Varying (LPV) matrices that are mapped to the system operating space. These matrices are derived from the trajectories of system state variables and system output variables during transients. The accuracy of LPV matrices depends on the selection of state variables. In previous reports, state variables were selected by adopting a complicated workflow requiring multiple software licenses and an advanced level of user expertise. In this report, a new workflow that automates the state variable selection process is presented. It significantly reduces the frequency of user interventions and does not require multiple software licenses. Each module in the new workflow is described in detail, and the input / output examples in each step of the workflow are provided. It was demonstrated that this workflow can greatly reduce the complexity of the state variable selection process, and that the updated FARM-Gamma and FARM-Delta validators can benefit from this workflow when solving the power dispatch problem of a representative IES test case. Finally, some code improvements that can further enhance the efficiency are suggested.

42 ENGINEERING↗