Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiological Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The Recovery of Medical Isotope 188 W from Irradiated W Metal Target - A New Approach

Tungsten-188 is in widespread use in 188 W(t 1/2 = 69 d )/ 188 Re(t 1/2 = 16.9 h ) biomedical generators. Oak Ridge National Laboratory has been providing this product to the world since 1999. At ORNL, 188 W is produced via irradiation in ORNL’s High Flux Isotope Reactor (HFIR). Enriched 186 W targets in the form of sintered metallic pellets or rings achieve a compact loading in the irradiation vessel, providing a high yield per unit target. The enrichment of the target is >90% 186 W, and this isotope undergoes double neutron capture to produce the desired 188 W product. While 188 W is produced by neutron bombardment, 191 Os(t 1/2 = 15.4 d ) is simultaneously produced as a by-product and expected to be separated from 188 W by postirradiation treatment.In the current processing pathway, the irradiated W metal rings are first converted into an oxide form of WO 3 by heating the irradiated W metal target at 750°C in a quartz reaction vessel inside a vertical furnace under a constant flow of air. During heating, W metal reacts with oxygen in the air to produce WO 3 , which is soluble in 6 M NaOH for preparation of 188 W product. This oxidation process also converts 188 Os (the decay daughter of 188 W) and 191 Os (15.4 d , the irradiation produced byproduct) into OsO 4 , a highly volatile and toxic gas. The gaseous effluents driven from the quartz reaction vessel are passed through a scrubbing array to remove OsO 4 before the air is discharged from the process. This heterogeneous oxidation method simultaneously achieves goals of (1) converting metal target to a soluble oxide form and (2) removing volatile OsO 4 away from the solid WO 3 product by air flow and absorbing the harmful Os species by the scrubbing array. But this method has two potential problems as well: (1) O 2 reacts with only W metal at high temperatures, not with W alloyed with other elements. The O 2 –W reaction will be retarded when formation of WRe or WC occurs, or even when a layer of non-W materials on the surface of the irradiated W rings.; (2) 100% absorption of OsO 4 of high yield (>90%) from the reaction of Os + O 2 is a strict requirement to the OsO 4 scrubbing system--so NaOH scrubbers of a redundant size (2x 1.5 L) are in use for safety reasons.To resolve above two potential problems, direct dissolution of the irradiated W metal target by a selected reagent is a preferred pathway to avoid heating step with generation of tremendous amount of volatile OsO 4 . Hydrogen peroxide (H 2 O 2 ) is such a candidate to dissolve W in forms of either metal or alloys, although literature lacks information of solubilities of Re or Os in H 2 O 2 . With experimental results of dissolving non-radioactive W, Re and Os in H 2 O 2 under various conditions, this report illustrates a method of H 2 O 2 dissolution for irradiated W target, with a complete dissolution of W and Re, but ≤10% dissolution of Os (converted into gaseous OsO 4 and carried out into a scrubbing for absorption) during processing irradiated W target. The portion of undissolved Os can be separated from W solution by a follow up filtration step. Solubilities of W, Re and Os in H 2 O 2 at a temperature range from 14° to 50°C are presented. And a dissolution rate of W metal per surface area of W metal in H 2 O 2 is calculated based on results of dissolving a W metal cylinder of known surface area in H 2 O 2 at room temperature without stirring.

07 ISOTOPE AND RADIATION SOURCES↗

Irradiation of Mo-100 Targets and Testing Fe(ll)CI 2 Precipitation for Tc-99 Removal

The production of molybdenum-99 (Mo-99) is a critical step in the generation of technetium-99m (Tc-99m), a radioisotope widely used in medical imaging. NorthStar Medical Radioisotopes, LLC is planning to produce the important medical radioisotope Mo-99 through a photonuclear reaction on molybdenum-100 (Mo-100). Accelerator production of Mo-99 using enriched Mo-100 targets yields undesirable isotopes, such as niobium-95 (Nb-95) and zirconium-95 (Zr-95). Previous studies reported that Nb and Zr isotopes can be effectively removed from Mo-99 products through coprecipitation with Fe(III). To enable the potential utilization of the first milking of Tc-99m from a Mo-99/Tc-99m generator, it is desirable to remove long-lived Tc-99. This can be accomplished by substituting Fe(III) with Fe(II) during the precipitation step, without affecting the removal of Zr and Nb isotopes. Previous experiments demonstrated up to 99+% removal of Tc using this method. It was also observed that the presence of hydrogen peroxide significantly impacts Tc removal. This was evident in the processing of enriched Mo-100 targets, where only 25% of Tc was removed. To further investigate this, another irradiation of enriched Mo-100 disks was conducted, followed by Tc-99 removal using Fe(II). Prior to irradiation, experimental conditions for Tc removal were optimized through several test runs using Mo-100 disks spiked with Tc-99. The results of these tests are discussed in this report.

07 ISOTOPE AND RADIATION SOURCES↗

Design of Hypothetical Processes for the Production of 131 I and 99 Mo from Activation Targets

For over six decades, medical isotope production has been a high-priority focus of many research reactors across the globe. The majority of these isotopes were produced using highly-enriched uranium (HEU) or low enriched uranium (LEU) – delivering millions of doses of diagnostic and therapeutic isotopes. As a consequence of this production, however, six decades of isotope production has resulted in massive quantities of spent uranium material worldwide with no known disposition pathway creating growing proliferation concerns. Supported by the National Nuclear Security Administration’s (NNSA) Material Management and Minimization (M3) program, there has been increased focus in the production of high-priority isotopes without special nuclear materials or without uranium altogether. Isotope production via activation can potentially fulfill regional isotope demands – particularly in under-developed regions without access to isotope supply chains. The benefits of this approach would be a reduction in uranium proliferation risks, less special nuclear material wastes, and reduced risk of supply disruption in the likely event that major isotope producers will again go off-line as has happened in recent years due to a number of factors.

07 ISOTOPE AND RADIATION SOURCES↗

Production of High Specific Activity 155 Tb, 161 Tb and 203 Pb for Research and Clinical Applications: Effective Target Design, Target Material Recycling and Radioisotope Separation (Final Technical Report)

The overall objectives of this project were (1) to develop methods for the production and separation of a diagnostic and therapeutic or “theranostic” pair of radioisotopes, terbium-155 ( 155 Tb) and terbium-161 ( 161 Tb) and (2) to train graduate students and postdoctoral fellows in technologies and methods used in radionuclide production. Radionuclides can be incorporated into drugs called radiopharmaceuticals that target a specific disease (e.g., cancer). The need for theranostic radionuclides is escalating with the clinical translation of radiopharmaceuticals due to their implementation in personalized medicine, which has demonstrated enhanced patient treatments. High purity and high specific activity radionuclides are critical for theranostic agent development, for example to maintain diagnostic image quality, to minimize radiation dose to the patient, and to increase uptake in the targeted tissue (e.g., tumor), especially in the case of receptor- and antigen-targeted agents. The 155 Tb (diagnostic) and 161 Tb (therapeutic) radioisotopes that were generated through this project are a theranostic pair with demonstrated potential for the development and translation into individualized, targeted, and dosimetry-driven radiotherapies. However, the development of such radiotherapies has been hindered by the lack of a routine and reliable supply of these isotopes in the United States. Methods for the production, separation, and supply of 155 Tb and 161 Tb were investigated and developed in this project. Further, the strong emphasis throughout the project on the training of graduate students and postdoctoral fellows has helped to ensure and enhance the nuclear science workforce through the training of the next generation of highly qualified scientists in nuclear and radiochemistry. This grant also continued a collaboration between scientists at the University of Washington (UW), the University of Missouri (MU) and Brookhaven National Laboratory (BNL). All three institutions were involved in the project, but to different degrees on the various tasks through which the overall objectives were met.

07 ISOTOPE AND RADIATION SOURCES↗

Radiation Protection Studies of International Space Station Extravehicular Activity Space Suits

This publication describes recent investigations that evaluate radiation shielding characteristics of NASA's and the Russian Space Agency's space suits. The introduction describes the suits and presents goals of several experiments performed with them. The first chapter provides background information about the dynamic radiation environment experienced at ISS and summarized radiation health and protection requirements for activities in low Earth orbit. Supporting studies report the development and application of a computer model of the EMU space suit and the difficulty of shielding EVA crewmembers from high-energy reentrant electrons, a previously unevaluated component of the space radiation environment. Chapters 2 through 6 describe experiments that evaluate the space suits' radiation shielding characteristics. Chapter 7 describes a study of the potential radiological health impact on EVA crewmembers of two virtually unexamined environmental sources of high-energy electrons-reentrant trapped electrons and atmospheric albedo or "splash" electrons. The radiological consequences of those sources have not been evaluated previously and, under closer scrutiny. A detailed computational model of the shielding distribution provided by components of the NASA astronauts' EMU is being developed for exposure evaluation studies. The model is introduced in Chapters 8 and 9 and used in Chapter 10 to investigate how trapped particle anisotropy impacts female organ doses during EVA. Chapter 11 presents a review of issues related to estimating skin cancer risk form space radiation. The final chapter contains conclusions about the protective qualities of the suit brought to light form these studies, as well as recommendations for future operational radiation protection.

Cucinotta, Francis A.↗

Sources, seasonal cycling, and fate of plutonium in a seasonally stratified and radiologically contaminated pond

Unlike short-term laboratory experiments, studies at sites historically contaminated with radionuclides can provide insight into contaminant migration behavior at environmentally-relevant decadal timescales. One such site is Pond B, a seasonally stratified reservoir within Savannah River Site (SC, USA) has low levels (μBq L –1 ) of plutonium in the water column. Here, we evaluate the origin of plutonium using high-precision isotope measurements, investigate the impact of water column geochemistry on plutonium cycling during different stratification periods, and re-evaluate long-term mass balance of plutonium in the pond. New isotopic data confirm that reactor-derived plutonium overwhelms input from Northern Hemisphere fallout at this site. Two suggested mechanisms for observed plutonium cycling in the water column include: (1) reductive dissolution of sediment-derived Fe(III)-(oxyhydr)oxides during seasonal stratification and (2) plutonium stabilization complexed strongly to Fe(III)-particulate organic matter (POM) complexes. While plutonium may be mobilized to a limited extent by stratification and reductive dissolution, peak plutonium concentrations are in shallow waters and associated with Fe(III)-POM at the inception of stratification. This suggests that plutonium release from sediments during stratification is not the dominant mechanism driving plutonium cycling in the pond. Importantly, our analysis suggests that the majority is retained in shallow sediments and may become increasingly recalcitrant.

54 ENVIRONMENTAL SCIENCES↗

Radioisotope replacement with compact electron linear accelerators

The replacement of radioactive sources with alternative technologies has been identified as a priority by international authorities, due to the risk of accidents and diversion by terrorists for use in Radiological Dispersal Devices. Many of these sources can be replaced with the X-rays produced by electron beams accelerated to MeV energies. However, the size, weight and costs of electron linacs must be significantly reduced to be considered for radioisotope replacement. RadiaBeam Technologies, LLC is developing a series of inexpensive compact electron accelerators in the 1–10 MeV range for radioisotope replacement such as Ir-192, Cs-137 and Co-60 for various applications. The dramatic level of miniaturization and cost-reduction was achieved thanks to the implementation of such innovative technologies as high-frequency magnetrons, split accelerating structure fabrication technology and solid-state Marx modulators. Here, in this paper, we overview RadiaBeam's compact linac developments, discuss the enabling technologies, and report on the current progress.

43 PARTICLE ACCELERATORS↗

Method and system for in vivo measurement of bone tissue using a two level energy source

Methods and apparatus are provided for radiologically determining the bone mineral content of living human bone tissue independently of the concurrent presence of adipose and other soft tissues. A target section of the body of the subject is irradiated with a beam of penetrative radiations of preselected energy to determine the attenuation of such beam with respect to the intensity of each of two radiations of different predetermined energy levels. The resulting measurements are then employed to determine bone mineral content.

Cameron, J. R.↗

Calculation of Groundwater Pathway Radiological Dose for the Hanford Site Composite Analysis Base Case

The purpose of this environmental calculation file (ECF) is to present the results of the exposure route-specific and total radiological dose assessments for the groundwater exposure pathway as a part of the updated Hanford Site Composite Analysis (CA). The purpose of these radiological dose assessments is to provide an estimate of the cumulative radiological impacts from all screened sources of ionizing radiation and exposure routes that could potentially contribute to the projected dose to a hypothetical member of the public from both existing or future disposal facilities and other sources including past-practice discharge sites.

61 RADIATION PROTECTION AND DOSIMETRY↗

Calculation of Dangerous Values for Radionuclides Considered by the IAEA Code of Conduct

The D-value or dangerous quantity system was designed by the International Commission for Radiological Protection for the determination of source protection categories that can be used to reduce the likelihood of accidents, the consequences of which could result in harm to individuals or costly or expensive cleanup. The process includes multiple scenarios for exposure and two different approaches to the evaluation of detriment. This document provides an example calculation using 137 Cs to walk through the complex process of determining its D-value in the hopes of making the process easily understandable.

61 RADIATION PROTECTION AND DOSIMETRY↗

FY24 accomplishments in preparation for startup of Activated Materials Laboratory (AML)

The Activated Materials Laboratory (AML) will be a new radiological facility at the Advanced Photon Source (APS) in Argonne National Laboratory (ANL), adjacent to the high-energy x-ray microscopy (HEXM) beamline in the long beamline building (LBB) constructed under the APS-upgrade (APS-U) project. The AML is a centralized facility to facilitate the safe conduct of experiments on activated materials at the APS. This report provides an overview of the status of the AML as a Nuclear Science User Facilities (NSUF) partner user facility in preparation for the general user access in 2025 upon the commissioning of the APS-U beamlines. The AML's scope, functionality and components are detailed. The NSUF partner beamlines’ commissioning status in the post-APS-U era is provided, along with the AML’s operational updates and operational plan.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Iron-Chromium-Aluminum Accident Tolerant Fuel Concept Source Term Accident Sequence Analysis - High Burnup Fuel Source Term Accident Sequence Analysis Supplement

To extend NUREG-1465 and high burnup fuel source term (SAND2023-01313) recommendations, representative radiological releases to containment – patterned after NUREG-1465 – have been evaluated for LWRs utilizing iron-chromium-aluminum (FeCrAl) alloys in place of zirconium-based alloys in major core structures (cladding and fuel canisters) and high burnup fuel with enrichments of 8% and 10% for PWRs and BWRs, respectively. Representative radionuclide releases are generated for this accident tolerant fuel concept by applying non-parametric bootstrap methods to MELCOR simulation results. Accident scenarios considered in this analysis include principle contributors to historical core damage frequency estimates for a range of nuclear reactor technologies representative of the operating U.S.A. fleet of nuclear reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cr-coated Accident Tolerant Fuel Concept Source Term Accident Sequence Analysis - High Burnup Fuel Source Term Accident Sequence Analysis Supplement

To extend NUREG-1465 and high burnup fuel source term (SAND2023-01313) recommendations, representative radiological releases to containment – patterned after NUREG-1465 – have been evaluated for LWRs utilizing the chromium-coating on major zircaloy structures (cladding and fuel canisters) and high burnup fuel with enrichments of 8% and 10% for PWRs and BWRs, respectively. Representative radionuclide releases are generated for this accident tolerant fuel concept by applying non-parametric bootstrap methods to MELCOR simulation results. Accident scenarios considered in this analysis include principle contributors to historical core damage frequency estimates for a range of nuclear reactor technologies representative of the operating U.S.A. fleet of nuclear reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development and testing of a fission-like neutron field for dosimetry and instrument calibrations based on deuterium-tritium generator

For nearly five decades 252 Cf sources have been used for testing and calibration over a wide range of neutron detection devices used for nuclear safety and radiation protection. However, the vastly increased cost of 252 Cf sources, its short half-life, and concerns about future shortage have prompted nuclear facilities and radiological calibration laboratories that rely on high-intensity neutron sources to seek alternatives. There appear to be no other radionuclide neutron sources that would match “like-to-like” 252 Cf performance characteristics. Alternatives of producing a fission-like neutron spectrum based on commercially available deuterium-tritium (D-T) generators, and without any fissionable materials or beryllium, have been explored. This paper describes efforts of designing the spectrum shaping assembly, its construction and installation. The produced neutron field was evaluated both from the perspective of the neutron fluence spectrum and the resulting dosimetric outcome. Finally, it was tested for practical application by examining response of various health physics instruments and personal monitoring devices in comparison to the response of those devices when exposed to 252 Cf. In conclusion, the response of survey-type instruments tested within the prototype, surrogate fission, reference field are acceptably close to their response in the targeted 252 Cf field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Fission-like Neutron Spectrum Shaping Assembly based on D-T Generator

For nearly five decades, 252 Cf sources have been used for testing and calibration over a wide range of neutron detection devices used for nuclear safety and radiation protection. However, the vastly increased cost of 252 Cf sources, its short half-life, and concerns about future shortage have prompted nuclear facilities and radiological calibration laboratories that rely on high-intensity neutron sources to seek alternatives. While there appear to be no other radionuclide neutron sources that would match the 252 Cf performance characteristics, all of them, including 252 Cf, present similar concerns in terms of hazards, safety, and security. As a possible solution to this issue, the Pacific Northwest National Laboratory (PNNL) developed a low-risk, cost-efficient alternative to produce fission-like spectra based on commercially available deuterium-tritium (D-T) neutron generators. The alternative of producing a fission-like neutron spectrum without any fissionable materials or beryllium would enable the nuclear facilities across the entire complex to eliminate their reliance on high intensity 252 Cf sources for nuclear safety and radiation protection applications, substantially reducing risks and associated costs. This report describes efforts of designing the spectrum shaping assembly, its construction and characterization of the neutron field produced. Performance of this newly developed D-T generator based neutron field is demonstrated via calibration of a criticality detector, neutron survey instruments, and personal dosimeters verified against current standardized fields produced by 252 Cf spontaneous fission sources.

42 ENGINEERING↗

Python Urban Deployment Model (PyUDM) v1.0.0

The Python Urban Deployment Model (PyUDM) is a simulation tool used to investigate networks of static radiation detectors in urban environments. PyUDM simulates traffic, stationary NaI gamma-ray detectors, and moving radioactive sources on simulated vehicles. The analyzed output of the simulations contain valuable insights into the performance of different configurations of urban radiological detector configurations such as their ability to detect sources moving through the environment. To accurately simulate radioactive material moving through urban environments, PyUDM combines Monte Carlo simulation tools, publicly available map and traffic data, and measured gamma-ray spectra from urban environments.

Rofors, Emil↗

Review of particle deposition to and removal from clothing, skin, and hair after a radioactive airborne dispersal event

Explosive Radiological Dispersal Devices (RDD) – aka dirty bombs – are seen as a credible method to carry out a radiological terror attack. After exploding a radioactive source, the radionuclide-laden plume will be blown downwind of ground zero, with particles falling out and potentially depositing on people caught in and under the cloud. Some of these people may not show any sign of radiation sickness and therefore not realize they have been contaminated and may take the radioactive particulate with them on their daily activities, thus spreading the radioactive particulate outside the initially contaminated area. This paper reviews the scientific literature to better understand the rate at which particulate deposits on and is removed from the different “surfaces” of a person, i.e., hair, skin, and clothing. Prior research indicates that: 1) particle deposition is usually higher on skin than on hair and clothing; 2) particle deposition is greater for a person with higher skin moisture, 3) stronger wind increases the deposition flux onto a person, and 4) the fraction of particulate deposited on the hair, skin, and clothing respectively depends on the length of the hair, assuming all the hair surface is available for deposition. The studies taken into consideration show that the largest uncertainty in particulate deposition onto a person is due to clothing type because of the different possible weave arrangements and tightness which translate into differences in actual surface area and surface roughness. A factor of 2-to-20 variation in deposition rate was found. Removal of the particulate from the contaminated person may be due to wind, a person's movement, and/or contact transfer, i.e., by touching a different clean surface. Experiments show that the majority of the particulate is resuspended within 2–6 h mostly depending on the intensity of physical activity. The largest uncertainty in particulate removal from skin depends on the skin moisture, transfer rate of single-contact, and how many objects/people a person touches per hour. No data for hair were found for particle removal and resuspension. The studies considered did not utilize radionuclides directly; however, data on adhesion of radioactive vs. their non-radioactive counterpart have shown that the uncertainty due to the radioactivity of the particles is lower than that due to other factors. In conclusion, an idealized scenario involving a single building in the path of the cloud showed the impact of building-influenced flow on the cloud transport path and mixing, which affects the radiological dose the downwind population is exposed to and consequently the health effects.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗