Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radio-frequency Linac”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Chromaticity of the lattice and beam stability in energy-recovery linacs

Energy recovery linacs (ERLs) are an emerging generation of accelerators promising to revolutionize the fields of high-energy physics and photon sciences. These accelerators combine the advantages of linear accelerators with that of storage rings, and hold the promise of delivering electron beams of unprecedented power and quality. Use of superconducting radio-frequency (SRF) cavities converts ERLs into nearly perfect "perpetuum mobile" accelerators, wherein the beam is accelerated to a desirable energy, used, and then gives the energy back to the RF field. One potential weakness of these devices is transverse beam break-up instability that could severely limit the available beam current. In this paper, I present a method of suppressing these dangerous effects using a natural phenomenon in the accelerators, viz., the chromaticity of the transverse motion.

43 PARTICLE ACCELERATORS↗

Status of intense permanent magnet proton source for China-accelerator driven sub-critical system Linac

Two compact intense 2.45 GHz permanent magnet proton sources and their corresponding low energy beam transport (LEBT) system were developed successfully for China accelerator driven sub-critical system in 2014. Both the proton sources operate at 35 kV potential. The beams extracted from the ion source are transported by the LEBT, which is composed of two identical solenoids, to the 2.1 MeV Radio-Frequency Quadrupole (RFQ). In order to ensure the safety of the superconducting cavities during commissioning, an electrostatic-chopper has been designed and installed in the LEBT line that can chop the continuous wave beam into a pulsed one. The minimum width of the pulse is less than 10 μs and the fall/rise time of the chopper is about 20 ns. The performance of the proton source and the LEBT, such as beam current, beam profile, emittance and the impact to RFQ injection will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Five-cell superconducting RF module with a PBG coupler cell: design and cold testing of the copper prototype

We report the design and experimental data for a copper prototype of a superconducting radio-frequency (SRF) accelerator module. The five-cell module has an incorporated photonic band gap (PBG) cell with couplers. The purpose of the PBG cell is to achieve better higher order mode (HOM) damping, which is vital for preserving the quality of high-current electron beams. Better HOM damping raises the current threshold for beam instabilities in novel SRF accelerators. The PBG design also increases the real-estate gradient of the linac because both HOM damping and the fundamental power coupling can be done through the PBG cell instead of on the beam pipe via complicated end assemblies. First, we will discuss the design and accelerating properties of the structure. The five-cell module was optimized to provide good HOM damping while maintaining the same accelerating properties as conventional elliptical-cell modules. We will then discuss the process of tuning the structure to obtain the desired accelerating gradient profile. Finally, we will list measured quality factors for the accelerating mode and the most dangerous HOMs.

43 PARTICLE ACCELERATORS↗

Operational Experience from LCLS-II Cryomodule Testing

This paper describes the initial operational experience gained from testing Linac Coherent Light Source II (LCLS-II) cryomodules at Fermilab’s Cryomodule Test Facility (CMTF). Strategies for a controlled slow cooldown to 100 K and a fast cooldown past the niobium superconducting transition temperature of 9.2 K will be described. The test stand for the cryomodules at CMTF is sloped to match gradient in the LCLS-II tunnel at Stanford Linear Accelerator (SLAC) laboratory, which adds an additional challenge to stable liquid level control. Control valve regulation, Superconducting Radio-Frequency (SRF) power compensation, and other methods of stabilizing liquid level and pressure in the cryomodule 2.0 K SRF cavity circuit will be discussed. Several different pumping configurations using cold compressors and warm vacuum pumps have been used on the cryomodule 2.0 K return line and the associated results will be described.

Wang, Renzhuo↗

Beam Commissioning and Integrated Test of the PIP-II Injector Test Facility

The PIP-II Injector Test (PIP2IT) facility is a near-complete low energy portion of the Superconducting PIP-II linac driver. PIP2IT comprises the warm front end and the first two PIP-II superconducting cryomodules. PIP2IT is designed to accelerate a 2 mA H⁻ beam to an energy of 20 MeV. The facility serves as a testbed for a number of advanced technologies required to operate PIP-II and provides an opportunity to gain experience with commissioning of the superconducting linac, significantly reducing project technical risks. Some PIP2IT components are contributions from international partners, who also lend their expertise to the accelerator project. The project has been successfully commissioned with the beam in 2021, demonstrating the performance required for the LBNF/DUNE. In this paper, we describe the facility and its critical systems. We discuss our experience with the integrated testing and beam commissioning of PIP2IT, and present commissioning results. This important milestone ushers in a new era at Fermilab of proton beam delivery using superconducting radio-frequency accelerators.

43 PARTICLE ACCELERATORS↗

An Optical Streaking Method for Measuring Femtosecond Electron Bunches

The measurement of the ultra-short electron bunch length on the femtosecond time scale constitutes a very challenging problem. In the x-ray free electron laser facilities such as the Linac Coherent Light Source, generation of a sub-ten femtoseconds electron beam with 20pC charge is possible, but direct measurements are very difficult due to the resolution limit of the present diagnostics. We propose a new method here based on the measurement of the electron beam energy modulation induced from laser-electron interaction in a short wiggler. A typical optical streaking method requires a laser wavelength much longer than the electron bunch length. In this paper a laser with its wavelength shorter than the electron bunch length has been adopted, while the slope on the laser intensity envelope is used to distinguish the different periods. With this technique it is possible to reconstruct the bunch longitudinal profile from a single shot measurement. Generation of ultrashort x-ray pulses at femtoseconds (fs) scale is of great interest within synchrotron radiation and free electron laser (FEL) user community. One of the simple methods is to operate the FEL facility at low charge. At the Linac Coherent Light Source (LCLS), we have demonstrated the capability of generating ultrashort electron-beam (e-beam) with a duration of less than 10 fs fwhm using 20 pC charge. The x-ray pulses have been delivered to the x-ray users with a similar or even shorter pulse duration. However, The measurement of such short electron or x-ray pulse length at the fs time-scale constitutes a challenging problem. A standard method using an S-band radio-frequency (rf) transverse deflector has been established at LCLS, which works like a streak camera for electrons and is capable of resolving bunch lengths as short as 25 fs fwhm. With this device, the electrons are transversely deflected by the high-frequency time-variation of the deflecting fields. Increasing the deflecting voltage and rf frequency are the right direction to achieve a better resolution. For example, by choosing an X-band transverse deflecting cavity, the expected resolution for LCLS beam with 4.3 GeV is about 1 fs rms. Typically the rf breakdown threshold and the power source availability prevent going to even higher voltage and frequency. With the highly-developed laser techniques, we can choose to streak the beam at optical frequencies. By jumping from rf to optical frequency, the wavelength is shortening by 4 to 5 orders. With an electron bunch length shorter than half period of the laser, we can apply the similar rf deflecting or zero-phasing method for e-beam bunch length measurements using a high-power laser. A short wiggler is required to provide interaction between the electron and the laser. For example, to measure the e-beam at the order of 1 m rms length, a laser with its wavelength of 10 {mu}m may be considered. For a typical few GeV e-beam, the wiggler period has to be large to satisfy the resonance condition. Also, if the e-beam is longer than one laser period, the different modulation periods will overlap and we cannot distinguish them. So this method is so far limited by the achievable long-wavelength laser power. To get an effective modulation on an e-beam of 4.3 GeV, the required laser power is about a few tens GW. In this paper we propose to adopt a high-power Ti:Sapphire laser (wavelength of 800 nm), and use the slope in the intensity envelope to distinguish the different modulation periods. First an ultrashort electron beam interacts with the Ti:Sapphire laser in a wiggler, where the electron energy is modulated at the same periods of the laser. If the laser pulse is long and the short electron bunch is overlapped (in time) with the middle part of the laser, such as the setup at LCLS laser heater, the different energy modulation periods on the electron beam will be overlapped on the energy profile. In this conditionwe typically have a double-horn distribution of the energy profile, and the electron-bunch length information cannot be retrieved. But if the laser pulse (with a Gaussian temporal shape) is relatively short, we can synchronize the e-beam with the laser at the slope region of the intensity envelope, and the amplitude of each energy modulation period will be different. Then these electrons pass through a dispersive section such as a spectrometer, after that this periodically-modulated energy profile can be observed in a transverse screen. By properly choosing the laser parameters, each modulation period will show as a separate streak on the screen. This modulation period in energy dimension correlates to the laser wavelength in time dimension. Since the laser wavelength is a known parameter, no additional calibration is needed. This provides a single shot, self-calibrated method for ultrashort electron bunch length measurements.

43 PARTICLE ACCELERATORS↗

Ultra-Short Electron Bunch and X-Ray Temporal Diagnostics with an X-Band Transverse Deflector

The measurement of ultra-short electron bunches on the femtosecond time scale constitutes a very challenging problem. In X-ray free-electron laser facilities such as the Linac Coherent Light Source (LCLS), generation of sub-ten femtosecond X-ray pulses is possible, and some efforts have been put into both ultra-short electron and X-ray beam diagnostics. Here we propose a single-shot method using a transverse rf deflector (X-band) after the undulator to reconstruct both the electron bunch and X-ray temporal profiles. Simulation studies show that about 1 fs (rms) time resolution may be achievable in the LCLS and is applicable to a wide range of FEL wavelengths and pulse lengths. The jitter, resolution and other related issues will be discussed. The successful operation of the Linac Coherent Light Source (LCLS), with its capability of generating free-electron laser (FEL) X-ray pulses from a few femtoseconds (fs) up to a few hundred fs, opens up vast opportunities for studying atoms and molecules on this unprecedented ultrashort time scale. However, tremendous challenges remain in the measurement and control of these ultrashort pulses with femtosecond precision, for both the electron beam (e-beam) and the X-ray pulses. For ultrashort e-beam bunch length measurements, a standard method has been established at LCLS using an S-band radio-frequency (rf) deflector, which works like a streak camera for electrons and is capable of resolving bunch lengths as short as {approx} 10 fs rms. However, the e-beam with low charges of 20 pC at LCLS, which is expected to be less than 10 fs in duration, is too short to be measured using this transverse deflector. The measurement of the electron bunch length is helpful in estimating the FEL X-ray pulse duration. However, for a realistic beam, such as that with a Gaussian shape or even a spiky profile, the FEL amplification varies along the bunch due to peak current or emittance variation. This will cause differences between the temporal shape or duration of the electron bunch and the X-ray pulse. Initial experiments at LCLS have revealed that characterization of the X-ray pulse duration on a shot-by-shot basis is critical for the interpretation of the data. However, a reliable x-ray pulse temporal diagnostic tool is not available so far at the LCLS. We propose a novel method in this paper to characterize the FEL X-ray pulse duration and shape. A transverse rf deflector is used in conjunction with an e-beam energy spectrometer, located after the FEL undulator. By measuring the difference in the e-beam longitudinal phase space between FEL-on and FEL-off, we can obtain the time-resolved energy loss and energy spread induced from the FEL radiation, allowing the FEL X-ray temporal shape to be reconstructed.

43 PARTICLE ACCELERATORS↗

Numerical Modeling of Ion-Optical Systems for Extraction of a Beam of Negative Hydrogen Ions and Its Acceleration and Matching with a Radio-Frequency Quadrupole Accelerator

A source of negative hydrogen ions is constructed at the Institute for High Energy Physics in order to raise the intensity of the U-70 accelerator complex using multiturn charge-exchange injection. The 3D ion-optical IBSimu simulation package was used to model and optimize the system for extraction of an ion beam from plasma, its acceleration to 100 keV, and matching with a radio-frequency quadrupole (RFQ) accelerator. The system of extraction of an ion beam with a current of 50 mA and electron-flow suppression was modeled. The magnetic transport channels with two solenoids and six quadrupole lenses were compared. The end goals of analysis of the matching channel were to obtain the needed Twiss parameters and to minimize the emittance growth at the RFQ input.

43 PARTICLE ACCELERATORS↗

Project X RFQ EM Design

Project X is a proposed multi-MW proton facility at Fermi National Accelerator Laboratory (FNAL). The Project X front-end would consist of an H- ion source, a low-energy beam transport (LEBT), a CW 162.5 MHz radio-frequency quadrupole (RFQ) accelerator, and a medium-energy beam transport (MEBT). Lawrence Berkeley National Laboratory (LBNL) and FNAL collaboration is currently developing the designs for various components in the Project X front end. This paper reports the detailed EM design of the CW 162.5 MHz RFQ that provides bunching of the 1-10 mA H- beam with acceleration from 30 keV to 2.1 MeV.

43 PARTICLE ACCELERATORS↗

Overview and Lessons Learned of the Jefferson Lab Cryomodule Production for the CEBAF 12 GeV Upgrade

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab is nearing completion of an energy upgrade from 6 to 12 GeV. An integral part of the upgrade is the addition of ten new cryomodules, each consisting of eight seven-cell superconducting radio-frequency (SRF) cavities. An average performance of 100+MV of acceleration per cryomodule is needed to achieve the 12 GeV beam energy goal. The production methodology was for industry to provide and deliver the major components to Jefferson Lab, where they were tested and assembled into cryomodules. The production process begins with an inspection upon receiving of all major components followed by individual performance qualification testing. The SRF cavities received their final chemical processing and cleaning at Jefferson Lab. The qualified components along with all associated hardware and instrumentation are assembled, tested, installed into CEBAF and run through an integrated system checkout in preparation for beam operations. The production process is complete and one of the first completed cryomodules has successfully produced 108 MV of acceleration with a linac beam current of 465 {micro}A.

43 PARTICLE ACCELERATORS↗

Design options for a superconducting ion linac

Following a review of the design options for a superconducting ion linac, we present here an alternative design for the pre-stripper section of the superconducting driver linac for the rare isotope science project (RISP) of the Institute for Basic Science in Korea. The proposed alternative design takes advantage of the recent accelerator developments at Argonne, namely for the recent ATLAS intensity and efficiency upgrade and the Fermilab proton improvement plan project (PIP-II). In particular, the state-of-the-art performance of quarter-wave (QWRs) and half-wave resonators (HWRs), the integrated steering correctors and cold beam position monitors (BPMs) for a compact cryomodule design. In order to simplify the design and avoid frequency transitions, we used two types of QWRs at 81.25 MHz while the baseline design has QWRs at 81.25 MHz and HWRs at 162.5 MHz. The new QWR types were optimized for β ~0.05 and ~0.11, respectively, and corrected for beam steering effects. Nine cryomodules are required to reach the stripping energy of 18.5 MeV/u for uranium beam. An alternative radio-frequency quadrupole (RFQ) design was also developed. It is optimized with the multi-harmonic buncher (MHB) to produce a much smaller longitudinal emittance, offering much needed flexibility for beam tuning and more tolerance to errors. Following the lattice design optimization, end-to-end beam dynamics simulations including most important sources of machine error were performed. The results showed that the design is robust and tolerant to errors with no beam loss observed for typical machine errors.

43 PARTICLE ACCELERATORS↗

High-throughput injection-acceleration of electron bunches from a linear accelerator to a laser wakefield accelerator

Plasma-based accelerators (PBAs) driven by either intense lasers (laser wakefield accelerators, LWFAs) or particle beams (plasma wakefield accelerators, PWFAs), can accelerate charged particles at extremely high gradients compared to conventional radio-frequency (RF) accelerators. In the past two decades, great strides have been made in this field, making PBA a candidate for next-generation light sources and colliders. However, these challenging applications necessarily require beams with good stability, high quality, controllable polarization and excellent reproducibility. To date, such beams are generated only by conventional RF accelerators. As such, it is important to demonstrate the injection and acceleration of beams first produced using a conventional RF accelerator, by a PBA. In some recent studies on LWFA staging and external injection-acceleration in PWFA only a very small fraction (from below 0.1% to few percent) of the injected charge (the coupling efficiency) was accelerated. For future colliders where beam energy will need to be boosted using multiple stages, the coupling efficiency per stage must approach 100%. Here we report the first demonstration of external injection from a photocathode-RF-gun-based conventional linear accelerator (LINAC) into a LWFA and subsequent acceleration without any significant loss of charge or degradation of quality, which is achieved by properly shaping and matching the beam into the plasma structure. Furthermore, this is an important step towards realizing a high-throughput, multi-stage, high-energy, hybrid conventional-plasma accelerator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Next generation HOM-damping

Research and development for superconducting radio-frequency cavities has made enormous progress over the last decades from the understanding of theoretical limitations to the industrial mass fabrication of cavities for large-scale particle accelerators. Key technologies remain hot topics due to continuously growing demands on cavity performance, particularly when in pursuit of high quality beams at higher beam currents or higher luminosities than currently achievable. This relates to Higher Order Mode (HOM) damping requirements. Meeting the desired beam properties implies avoiding coupled multi-bunch or beam break-up instabilities depending on the machine and beam parameters that will set the acceptable cavity impedance thresholds. The use of cavity HOM-dampers is crucial to absorb the wakefields, comprised by all beam-induced cavity Eigenmodes, to beam-dynamically safe levels and to reduce the heat load at cryogenic temperature. Cavity damping concepts may vary, but are principally based on coaxial and waveguide couplers as well as beam line absorbers or any combination. Next generation Energy Recovery Linacs and circular colliders call for cavities with strong HOM-damping that can exceed the state-of-the-art, while the operating mode efficiency shall not be significantly compromised concurrently. This imposes major challenges given the rather limited damping concepts. A detailed survey of established cavities is provided scrutinizing the achieved damping performance, shortcomings, and potential improvements. The scaling of the highest passband mode impedances is numerically evaluated in dependence on the number of cells for a single-cell up to a nine-cell cavity, which reveals the increased probability of trapped modes. This is followed by simulations for single-cell and five-cell cavities, which incorporate multiple damping schemes to assess the most efficient concepts. The usage and viability of on-cell dampers is elucidated for the single-cell cavity since it can push the envelope towards quasi HOM-free operation suited for next generation storage and collider rings. Geometrical end-cell shape alterations for the five-cell cavity with already efficient mode damping are discussed as a possibility to further lower specific high impedance modes. Lastly, the findings are eventually put into relation with demanding impedance instability thresholds in future collider rings.

43 PARTICLE ACCELERATORS↗

H{sup -} beam transport experiments in a solenoid low energy beam transport

The Front End Test Stand (FETS) is located at Rutherford Appleton Laboratory and aims for a high current, fast chopped 3 MeV H{sup -} ion beam suitable for future high power proton accelerators like ISIS upgrade. The main components of the front end are the Penning ion source, a low energy beam transport line, an radio-frequency quadrupole (RFQ) and a medium energy beam transport (MEBT) providing also a chopper section and rebuncher. FETS is in the stage of commissioning its low energy beam transport (LEBT) line consisting of three solenoids. The LEBT has to transport an H{sup -} high current beam (up to 60 mA) at 65 keV. This is the injection energy of the beam into the RFQ. The main diagnostics are slit-slit emittance scanners for each transversal plane. For optimizing the matching to the RFQ, experiments have been performed with a variety of solenoid settings to better understand the actual beam transport. Occasionally, source parameters such as extractor slit width and beam energy were varied as well. The paper also discusses simulations based on these measurements.

43 PARTICLE ACCELERATORS↗

Towards Construction of a Novel Nanometer-Resolution MeV-STEM for Imaging Thick Frozen Biological Samples

Driven by life-science applications, a mega-electron-volt Scanning Transmission Electron Microscope (MeV-STEM) has been proposed here to image thick frozen biological samples as a conventional Transmission Electron Microscope (TEM) may not be suitable to image samples thicker than 300–500 nm and various volume electron microscopy (EM) techniques either suffering from low resolution, or low speed. The high penetration of inelastic scattering signals of MeV electrons could make the MeV-STEM an appropriate microscope for biological samples as thick as 10 μm or more with a nanoscale resolution, considering the effect of electron energy, beam broadening, and low-dose limit on resolution. The best resolution is inversely related to the sample thickness and changes from 6 nm to 24 nm when the sample thickness increases from 1 μm to 10 μm. To achieve such a resolution in STEM, the imaging electrons must be focused on the specimen with a nm size and an mrad semi-convergence angle. This requires an electron beam emittance of a few picometers, which is ~1000 times smaller than the presently achieved nm emittance, in conjunction with less than 10 -4 energy spread and 1 nA current. We numerically simulated two different approaches that are potentially applicable to build a compact MeV-STEM instrument: (1) DC (Direct Current) gun, aperture, superconducting radio-frequency (SRF) cavities, and STEM column; (2) SRF gun, aperture, SRF cavities, and STEM column. Beam dynamic simulations show promising results, which meet the needs of an MeV-STEM, a few-picometer emittance, less than 10 -4 energy spread, and 0.1–1 nA current from both options. Also, we designed a compact STEM column based on permanent quadrupole quintuplet, not only to demagnify the beam size from 1 μm at the source point to 2 nm at the specimen but also to provide the freedom of changing the magnifications at the specimen and a scanning system to raster the electron beam across the sample with a step size of 2 nm and the repetition rate of 1 MHz. This makes it possible to build a compact MeV-STEM and use it to study thick, large-volume samples in cell biology.

36 MATERIALS SCIENCE↗

Design, development, and acceleration trials of radio-frequency quadrupole

A deuteron radio frequency quadrupole (RFQ) accelerator has been designed, fabricated, and tested at BARC, which will be used for neutron generation. The RFQ operates at a frequency of 350 MHz and needs an inter-vane voltage of 44 kV to accelerate the deuteron beam to 400 keV within a length of 1.03 m. The error analysis shows that the offset of two opposite vanes in the same direction by 100 μm leads to a change in resonant frequency by 1.3 MHz and a significant change of fields in the quadrants (∼±40% with respect to average field). From the 3D analysis, we have observed that the unwanted dipole mode frequencies are very near to the quadrupole mode frequency which will make structure sensitive to the perturbations. In order to move the dipole modes away from the quadrupole modes, we have used the dipole stabilizer rods. The 5 wire transmission line theory was used to study the perturbative analysis of the RFQ and based on this a computer program has been written to tune the cavity to get required field distribution. Based on these studies, a 1.03 m long RFQ made of OFE copper has been fabricated and tested. Even though the RFQ was designed for deuteron (D{sup +}) beam, we tested it by accelerating both the proton (H{sup +}) and D{sup +} beams. The RFQ was operated in pulsed mode and accelerated both H{sup +} and D{sup +} beams to designed values of 200 and 400 keV, respectively. The measured parameters are in good agreement with the designed values validating our simulations and fabrication processes. In this paper, simulations, RF measurements, and beam commissioning results are presented.

43 PARTICLE ACCELERATORS↗

RF conditioning and beam experiments on 400 keV RFQ accelerator at BARC

A 400 keV Radio-frequency quadrupole accelerator (RFQ) has been designed, developed and tested at BARC. This will be used as a neutron generator (via D-T reaction). The RFQ operates at a resonant frequency of 350 MHz and needs an RF power of ∼ 60 kW to accelerate the deuteron beam to 400 keV within a length of 1.03 m. Though the RFQ is designed for deuteron beam, it was tested by accelerating both the proton and deuteron beams to their designed values of 200 and 400 keV respectively. The proton and deuteron beam experiments required peak RF power of approx. 15 kW and 60 kW respectively at 350 MHz. The RF power from the tetrode amplifier and coaxial transmission lines is coupled to the cavity by a coaxial loop coupler. As the coupler and cavity operated at vacuum of better than 2e-6 torr, extensive RF conditioning of the cavity and coupler was performed to reach at the desired power levels. (author)

43 PARTICLE ACCELERATORS↗

Study of ponderomotive instability in the FRIB beta=0.53 half-wave resonator

Superconducting radio-frequency niobium cavities are susceptible to deformations caused by external or internal forces, leading to shifts in the cavity resonant frequency. One source of deformation comes from the radiation pressure of the cavity fields, producing the so-called Lorentz force detuning effect. This effect can couple to the cavity mechanical modes in generator driven mode, leading to ponderomotive instability. In the FRIB 322 MHz, β=0.53 Half-wave Resonators (HWR), the instability appeared when the cavity was detuned, with thresholds depending on low-level RF control parameters, such as closed loop gain, as well as accelerating gradient. Using a measured Lorentz Transfer Function, Simulink simulations were conducted to predict the instability thresholds, which were then compared with the experimental results. We will discuss how these thresholds can be broadened to enable stable operation at higher gradients.

Accelerator Physics↗