Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radio frequency techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Robust superconductivity and the suppression of charge-density wave in the quasi-skutterudites Ca 3 ( Ir 1 – x Rh x ) 4 Sn 13 single crystals at ambient pressure

Single crystals of the quasi-skutterudite compounds Ca 3 (Ir 1-x Rh x ) 4 Sn 13 (3–4–13) were synthesized by flux growth and characterized by x-ray diffraction, energy dispersive x-ray spectroscopy, magnetization, resistivity, and radio frequency magnetic susceptibility techniques. The coexistence and competition between the charge density wave (CDW) and superconductivity was studied by varying the Rh/Ir ratio. The superconducting transition temperature, T c , varies from 7 K in pure Ir (x = 0) to 8.3 K in pure Rh (x = 1). Temperature-dependent electrical resistivity reveals monotonic suppression of the CDW transition temperature, T CDW (x). The CDW starts in pure Ir, x = 0, at T CDW ≈ 40 K and extrapolates roughly linearly to zero at x c ≈ 0.53–0.58 under the superconducting dome. Magnetization and transport measurements show a significant influence of CDW on superconducting and normal states. Meissner expulsion is substantially reduced in the CDW region, indicating competition between the CDW and superconductivity. The low-temperature resistivity is higher in the CDW part of the phase diagram, consistent with the reduced density of states due to CDW gapping. Its temperature dependence just above T c shows signs of non-Fermi liquid behavior in a cone-like composition pattern. We conclude that the Ca 3 (Ir 1-x Rh x ) 4 Sn 13 alloy is a good candidate for a composition-driven quantum critical point at ambient pressure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Temperature, rf field, and frequency dependence performance evaluation of superconducting niobium half-wave coaxial cavity

Recent advancement in superconducting radio frequency cavity processing techniques, with diffusion of impurities within the RF penetration depth, resulted in high quality factor with increase in quality factor with increasing accelerating gradient. The increase in quality factor is the result of a decrease in the surface resistance as a result of nonmagnetic impurities doping and change in electronic density of states. The fundamental understanding of the dependence of surface resistance on frequency and surface preparation is still an active area of research. Here, we present the result of RF measurements of the TEM modes in a coaxial half-wave niobium cavity resonating at frequencies between 0.3 ? 1.3 GHz. The temperature dependence of the surface resistance was measured between 4.2 K and 1.6 K. The field dependence of the surface resistance was measured at 2.0 K. The baseline measurements were made after standard surface preparation by buffered chemical polishing.

Dhakal, P.↗

Neutral Atmosphere Properties Determining D-region Electron Densities

The increasing discoveries of various manifestations of meteorological control of the D region ionization and the growth of techniques for its measurement provide a challenge to meteorologists to test their insight into middle atmosphere processes with the physical interpretation of D layer phenomena. Models for ion production due to photoionization of minor atmospheric nitric oxide by quasi-monochromatic solar Lyman-alpha radiation are presented. A ground based measuring technique using low frequency radio reflection heights is briefly described and an approach to the interpretation of data acquired by this method is discussed. It is shown that D region electron density variations can provide an efficient diagnostic tool for the detection of perturbations of the circulation state of the middle atmosphere.

Taubenheim, J.↗

KNbO3 single crystal growth by the radio frequency heating Czochralski method

A radio frequency heating Czochralski technique to obtain single crystal KNbO3 is first presented. The technological parameters of KNbO3 crystal growth by the Czochralski technique and its pulling conditions were studied in detail. The experiments on second harmonic generation using 1.06 micrometer Nd:YAG laser in KNbO3 have been conducted. The second harmonic efficiency for upconversion of KNbO3 is found to be as high as that of NaBa2Nb5O15. An automatic scanning measurement for the optical homogeneity of KNbO crystal is also described. KNbO3 is revealed to be a potentially useful nonlinear material for optical device applications.

Wang, W.↗

Magnetic Microspheres for Therapeutical Applications

Hyperthermia is a well known cancer therapy and consists of heating a tumor region to the elevated temperatures in the range of 40-45 C for an extended period of time (2-8 hours). This leads to thermal inactivation of cell regulatory and growth processes with resulting widespread necrosis, carbonization and coagulation. Moreover, heat boosts the tumor response to other treatments such as radiation, chemotherapy or immunotherapy. Of particular importance is careful control of generated heat in the treated region and keeping it localized. Higher heating, to about 56 C can lead to tissue thermo-ablation. With accurate temperature control, hyperthermia has the advantage of having minimal side effects. Several heating techniques are utilized for this purpose, such as whole body hyperthermia, radio-frequency (RF) hyperthermia, ultrasound technique, inductive microwave antenna hyperthermia, inductive needles (thermoseeds), and magnetic fluid hyperthermia (MFH).MFH offers many advantages as targeting capability by applying magnets. However, this technology still suffers significant inefficiencies due to lack of thermal control. This paper will provide a review of the topic and outline the ongoing work in this area. The main emphasis is in devising ways to overcome the technical difficulty in hyperthermia therapy of achieving a uniform therapeutic temperature over the required region of the body and holding it steady. The basic obstacle of the present heating methods are non-uniform thermal properties of the tissue. Our approach is to develop a novel class of magnetic fluids which have inherent thermoregulating properties. We have identified a few magnetic alloys which can serve as a suitable nano-particle material. The objective is to synthesize, characterize and evaluate the efficacy of TRMF for hyperthermia therapy.

Mazuruk, K.↗

Magnetic Microspheres and Tissue Model Studies for Therapeutical Applications

Hyperthermia is a well known cancer therapy and consists of heating a tumor region to the elevated temperatures in the range of 40-45 C for an extended period of time (2-8 hours). This leads to thermal inactivation of cell regulatory and growth processes with resulting widespread necrosis, carbonization and coagulation. Moreover, heat boosts the tumor response to other treatments such as radiation, chemotherapy or immunotherapy. Of particular importance is careful control of generated heat in the treated region and keeping it localized. Higher heating, to about 56 C can lead to tissue thermo-ablation. With accurate temperature control, hyperthermia has the advantage of having minimal side effects. Several heating techniques are utilized for this purpose, such as whole body hyperthermia, radio-frequency (RF) hyperthermia, ultrasound technique, inductive microwave antenna hyperthermia, inductive needles (thermoseeds), and magnetic fluid hyperthermia (MFH).MFH offers many advantages as targeting capability by applying magnets. However, this technology still suffers significant inefficiencies due to lack of thermal control. This paper will provide a review of the topic and outline the ongoing work in this area. The main emphasis is in devising ways to overcome the technical difficulty in hyperthermia breast therapy of achieving a uniform therapeutic temperature over the required region of the body and holding it steady for an extended period (2-3 hours). The basic shortcomings of the presently utilized heating methods stem from the non-uniform thermal properties of the tissue and the point heating characteristics of the techniques without any thermal control. Our approach is to develop a novel class of magnetic fluids, which have inherent thermoregulating properties. We have identified a few magnetic alloys which can serve as suitable nano to micron-size particle material. The objective is to synthesize, characterize and evaluate the efficacy of Thermo Regulating Magnetic Fluids (TRMF) for hyperthermia therapy. The development of a tissue model and testing the fluid dynamics of particle motion, settling, distribution in the tissue matrix and heat generation will be discussed.

Ramachandran, N.↗

Biomedical Monitoring By A Novel Noncontact Radio Frequency Technology Project

The area of Space Health and Medicine is one of the NASA's Space Technology Grand Challenges. Space is an extreme environment which is not conducive to human life. The extraterrestrial environment can result in the deconditioning of various human physiological systems and thus require easy to use physiological monitoring technologies in order to better monitor space crews for appropriate health management and successful space missions and space operations. Furthermore, the Space Technology Roadmap's Technology Area Breakdown Structure calls for improvements in research to support human health and performance (Technology Area 06). To address these needs, this project investigated a potential noncontact and noninvasive radio frequency-based technique of monitoring central hemodynamic function in human research subjects in response to orthostatic stress.

Portfolio↗

Mars 2020 Entry, Descent, and Landing as Observed by Radio Science Techniques at UHF and X-band Frequencies

On February 18, 2021, NASA’s Mars 2020 Rover “Perseverance” conducted the Entry, Descent, and Landing (EDL) sequence to land safely on the surface of Mars at Jezero Crater. Due to the criticality of the EDL sequence, redundant telecommunications strategies were utilized to observe the event. The rover transmitted an X-band (8.4 GHz) signal encoded with Multiple Frequency Shift Keying tones direct-to-Earth and a UHF (401.5 MHz) signal with 8 kbps encoded telemetry to orbiters, which relayed the signal back to Earth at X-band. NASA’s Deep Space Network complexes at Goldstone, California and Madrid, Spain received the direct-to-Earth X-band signal. Two of the largest steerable radio telescopes in the world, the 100-meter Green Bank Telescope in West Virginia and the Effelsberg 100-meter Radio Telescope in Germany also received the UHF carrier signal on Earth. During the EDL event, full spectrum recordings of the UHF and X-band signals were captured at these observatories using open-loop receivers. Real-time and post-processing signal analysis to determine power level, received frequency, and Doppler shift allowed determination of the spacecraft’s health and safety state during critical sequences, including event detection such as atmospheric entry, plasma blackouts, and parachute deployment. Simultaneous observations of the UHF and X-band radio links allow for redundancy in the event of a fault and greatly improve confidence in Doppler event detection.

Gladden, Roy↗

Radio-Frequency Tank Eigenmode Sensor for Propellant Quantity Gauging

Although there are several methods for determining liquid level in a tank, there are no proven methods to quickly gauge the amount of propellant in a tank while it is in low gravity or under low-settling thrust conditions where propellant sloshing is an issue. Having the ability to quickly and accurately gauge propellant tanks in low-gravity is an enabling technology that would allow a spacecraft crew or mission control to always know the amount of propellant onboard, thus increasing the chances for a successful mission. The Radio Frequency Mass Gauge (RFMG) technique measures the electromagnetic eigenmodes, or natural resonant frequencies, of a tank containing a dielectric fluid. The essential hardware components consist of an RF network analyzer that measures the reflected power from an antenna probe mounted internal to the tank. At a resonant frequency, there is a drop in the reflected power, and these inverted peaks in the reflected power spectrum are identified as the tank eigenmode frequencies using a peak-detection software algorithm. This information is passed to a pattern-matching algorithm, which compares the measured eigenmode frequencies with a database of simulated eigenmode frequencies at various fill levels. A best match between the simulated and measured frequency values occurs at some fill level, which is then reported as the gauged fill level. The database of simulated eigenmode frequencies is created by using RF simulation software to calculate the tank eigenmodes at various fill levels. The input to the simulations consists of a fairly high-fidelity tank model with proper dimensions and including internal tank hardware, the dielectric properties of the fluid, and a defined liquid/vapor interface. Because of small discrepancies between the model and actual hardware, the measured empty tank spectra and simulations are used to create a set of correction factors for each mode (typically in the range of 0.999 1.001), which effectively accounts for the small discrepancies. These correction factors are multiplied to the modes at all fill levels. By comparing several measured modes with the simulations, it is possible to accurately gauge the amount of propellant in the tank. An advantage of the RFMG approach of applying computer simulations and a pattern-matching algorithm is that the Although there are several methods for determining liquid level in a tank, there are no proven methods to quickly gauge the amount of propellant in a tank while it is in low gravity or under low-settling thrust conditions where propellant sloshing is an issue. Having the ability to quickly and accurately gauge propellant tanks in low-gravity is an enabling technology that would allow a spacecraft crew or mission control to always know the amount of propellant onboard, thus increasing the chances for a successful mission. The Radio Frequency Mass Gauge (RFMG) technique measures the electromagnetic eigenmodes, or natural resonant frequencies, of a tank containing a dielectric fluid. The essential hardware components consist of an RF network analyzer that measures the reflected power from an antenna probe mounted internal to the tank. At a resonant frequency, there is a drop in the reflected power, and these inverted peaks in the reflected power spectrum are identified as the tank eigenmode frequencies using a peak-detection software algorithm. This information is passed to a pattern-matching algorithm, which compares the measured eigenmode frequencies with a database of simulated eigenmode frequencies at various fill levels. A best match between the simulated and measured frequency values occurs at some fill level, which is then reported as the gauged fill level. The database of simulated eigenmode frequencies is created by using RF simulation software to calculate the tank eigenmodes at various fill levels. The input to the simulations consists of a fairly high-fidelity tank model with proper dimensions and including internal tank harare, the dielectric properties of the fluid, and a defined liquid/vapor interface. Because of small discrepancies between the model and actual hardware, the measured empty tank spectra and simulations are used to create a set of correction factors for each mode (typically in the range of 0.999 1.001), which effectively accounts for the small discrepancies. These correction factors are multiplied to the modes at all fill levels. By comparing several measured modes with the simulations, it is possible to accurately gauge the amount of propellant in the tank. An advantage of the RFMG approach of applying computer simulations and a pattern-matching algorithm is that the

Zimmerli, Gregory A.↗

Spacecraft Multiple Array Communication System Performance Analysis

The Communication Systems Simulation Laboratory (CSSL) at the NASA Johnson Space Center is tasked to perform spacecraft and ground network communication system simulations, design validation, and performance verification. The CSSL has developed simulation tools that model spacecraft communication systems and the space and ground environment in which the tools operate. In this paper, a spacecraft communication system with multiple arrays is simulated. Multiple array combined technique is used to increase the radio frequency coverage and data rate performance. The technique is to achieve phase coherence among the phased arrays to combine the signals at the targeting receiver constructively. There are many technical challenges in spacecraft integration with a high transmit power communication system. The array combining technique can improve the communication system data rate and coverage performances without increasing the system transmit power requirements. Example simulation results indicate significant performance improvement can be achieved with phase coherence implementation.

Hwu, Shian U.↗

Detection, Localization, and Tracking of Unauthorized UAS and Jammers

Small unmanned aircraft systems (UASs) are expected to take major roles in future smart cities, for example, by delivering goods and merchandise, potentially serving as mobile hot spots for broadband wireless access, and maintaining surveillance and security. Although they can be used for the betterment of the society, they can also be used by malicious entities to conduct physical and cyber attacks to infrastructure, private/public property, and people. Even for legitimate use-cases of small UASs, air traffic management (ATM) for UASs becomes of critical importance for maintaining safe and collusion-free operation. Therefore, various ways to detect, track, and interdict potentially unauthorized drones carries critical importance for surveillance and ATM applications. In this paper, we will review techniques that rely on ambient radio frequency signals (emitted from UASs), radars, acoustic sensors, and computer vision techniques for detection of malicious UASs. We will present some early experimental and simulation results on radar-based range estimation of UASs, and receding horizon tracking of UASs. Subsequently, we will overview common techniques that are considered for interdiction of UASs.

surveillance↗

Two Optical-Beam-Forming Concepts For Array Antennas

Two optical-beam-forming concepts selected for development of phased-array antennas. Involve use of novel combinations of optical and electronic techniques to distribute radio-frequency signal to or from antenna elements in array: phase and amplitude of radio-frequency signal traveling to or from each element controlled in such way to cause array as whole to transmit or receive signal in desired spatial pattern, steered, narrowed, broadened, or otherwise varied. Techniques result in compact, lightweight beam-steering antennas. Potential applications include steered-beam or quasi-optical microwave antennas in communication and radar systems, remote control of antennas in general, and photonic communication. With some modifications, transmitting and receiving configurations incorporated into single system.

Wu, Te-Kao↗

Feasibility Study of a Satellite Solar Power Station

A feasibility study of a satellite solar power station (SSPS) was conducted to: (1) explore how an SSPS could be flown and controlled in orbit; (2) determine the techniques needed to avoid radio frequency interference (RFI); and (3) determine the key environmental, technological, and economic issues involved. Structural and dynamic analyses of the SSPS structure were performed, and deflections and internal member loads were determined. Desirable material characteristics were assessed and technology developments identified. Flight control performance of the SSPS baseline design was evaluated and parametric sizing studies were performed. The study of RFI avoidance techniques covered (1) optimization of the microwave transmission system; (2) device design and expected RFI; and (3) SSPS RFI effects. The identification of key issues involved (1) microwave generation, transmissions, and rectification and solar energy conversion; (2) environmental-ecological impact and biological effects; and (3) economic issues, i.e., costs and benefits associated with the SSPS. The feasibility of the SSPS based on the parameters of the study was established.

Glaser, P. E.↗

Radio-Frequency Rapid Thermal Processing Enabling Spatial Phase Transformation and Nanocrystallization of Soft Magnetic Amorphous Alloys

Thermal processing of soft magnetic amorphous and nanocrystalline alloys is explored under the influence of radio-frequency induction-heating techniques. Direct induction-heating concepts based on longitudinal and transverse flux heating are examined and the details of electromagnetic fields interaction with metallic strips are discussed by analytical calculations as well as finite element analysis. Initial experimental results confirming spatial control of phase transformations and nanocrystallization within a single strip of Finemet Fe-based amorphous ribbons are reported. Here, the degree to which primary and secondary crystallization temperature are achieved depends on the spacing between the ribbon relative to the induction coil as well as the coil design and configuration. For transverse coil configurations, the local temperature and therefore microstructural evolution is different across the lateral dimension of processed ribbons, with reduced gap sizes producing enhanced peak temperatures and larger temperature distributions with greater spatial variation in microstructure. In addition, indirect susceptor-based induction heating under tension is performed and the impact of microstructure is demonstrated. Herein, potential for exploiting spatially optimized phase transformations is illustrated through electromagnetic field–assisted processing in a scalable manufacturing process with amorphous and nanocrystalline soft magnetic alloys.

36 MATERIALS SCIENCE↗