Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Coupled Gel/Seeded Growth of Cs2AgBiBr6 Single Crystals for Radiation Detection

Abstract— The all-inorganic lead free Cs2AgBiBr6 perovskite represents a highly promising environment-friendly radiation detector material. The first attempt to grow Cs2AgBiBr6 single crystals using the unique gel growth method is reported in this study. This technique enables controlled reagent diffusion in a gel medium at room temperature, fostering the growth of visible single crystals. It offers advantages over conventional methods, leading to fewer equilibrium and non-equilibrium defects and simplified execution. Interestingly, the as-grown crystals exhibited variations in size and colors within the gel matrix, indicating the influence of Bi solutes in Bi-poor and Bi-rich Cs2AgBiBr6 crystals. Once the crystals were confirmed by powder xray diffraction, a series of comprehensive material characterizations was performed. The resistivity of Cs2AgBiBr6 single crystals was measured at 1.12x107 Ω•cm. Trap density analysis yielded a value of 2.82 x1010 cm-3. The charge carrier mobility was determined to be 32.9 cm2V-1S-1, suggesting the suitability for radiation detector applications. Additional growth optimization is going on and further characterization will be reported during the presentation. Our work helps accelerate the development of lead-free perovskite materials toward radiation detector applications.

James, Ralph B.↗

Thermal Stability Analysis for a Heliocentric Gravitational Radiation Detection Mission

The Laser Interferometer Space Antenna (LISA) mission is designed for detailed studies of low-frequency gravitational radiation. The mission is currently a candidate for ESA's post-Horizon 2000 program. Thermal noise affects the measurement in at least two ways. Thermal variation of the length of the optical cavity to which the lasers are stabilized introduces phase variations in the interferometer signal, which have to be corrected for by using data from the two arms separately.

Laser Interferometer Space Antenna LISA gravitatio↗

Enhancement of radiation detection performance with reduction of EH 6/7 deep levels in n-type 4H–SiC through thermal oxidation

We report the effect of EH 6/7 electron trap centers alone on the performance of high-resolution radiation detectors fabricated on n-type 4H–SiC epitaxial layers. A Schottky barrier detector (SBD) and a metal-oxide-semiconductor (MOS) capacitor detector fabricated using two sister samples derived from the same 50 μm 4H–SiC parent wafer exhibited widely different energy resolutions of 0.4% and 0.9% for 5486 keV alpha particles. An equivalent noise charge model analysis ruled out the effect of the detector capacitance and the leakage current on the resolution of the detectors. Deep level transient spectroscopic studies revealed the presence of two trapping centers in each detector within the temperature scan range 240–800 K. The Z 1/2 center, a potential electron trap, was detected in both the detectors in equal concentration, which suggested that the observed difference in the energy resolution is due to the presence of the other defect, the EH 6/7 center, in the SBD. The capture cross section of the EH 6/7 center was calculated to be three orders of magnitude higher than the second defect [a carbon antisite vacancy (CAV) center] observed in the MOS detector with an activation energy of 1.10 eV, which accounted for the enhanced electronic trapping in the SBD leading to its poor energy resolution. It has been proposed that the EH 6/7 centers in the SBD have likely been reconfigured to CAV pairs during the thermal growth of the silicon dioxide layer in the MOS detector. The proposed formation mechanism of CAV, a stable qubit state for quantum information processing, addresses the outstanding questions related to the role of defect dynamics in their formation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Halide Perovskites and Their Derivatives for Efficient, High‐Resolution Direct Radiation Detection: Design Strategies and Applications

Abstract The past decade has witnessed a rapid rise in the performance of optoelectronic devices based on lead‐halide perovskites (LHPs). The large mobility‐lifetime products and defect tolerance of these materials, essential for optoelectronics, also make them well‐suited for radiation detectors, especially given the heavy elements present, which is essential for strong X‐ray and γ‐ray attenuation. Over the past decade, LHP thick films, wafers, and single crystals have given rise to direct radiation detectors that have outperformed incumbent technologies in terms of sensitivity (reported values up to 3.5 × 10 6 µC Gy air −1 cm −2 ), limit of detection (directly measured values down to 1.5 nGy air s −1 ), along with competitive energy and imaging resolution at room temperature. At the same time, lead‐free perovskite‐inspired materials (e.g., methylammonium bismuth iodide), which have underperformed in solar cells, have recently matched and, in some areas (e.g., in polarization stability), surpassed the performance of LHP detectors. These advances open up opportunities to achieve devices for safer medical imaging, as well as more effective non‐invasive analysis for security, nuclear safety, or product inspection applications. Herein, the principles behind the rapid rises in performance of LHP and perovskite‐inspired material detectors, and how their properties and performance link with critical applications in non‐invasive diagnostics are discussed. The key strategies to engineer the performance of these materials, and the important challenges to overcome to commercialize these new technologies are also discussed.

36 MATERIALS SCIENCE↗

Study of the atmospheric effects on the radiation detected by the sensor aboard orbiting platforms (ERTS/LANDSAT)

The author has identified the following significant results. Multispectral scanner data for Brasilia was corrected for atmospheric interference using the LOWTRAN-3 computer program and the analytical solution of the radiative transfer equation. This improved the contrast between two natural targets and the corrected images of two different dates were more similar than the original ones. Corrected images of MSS data for Ribeirao Preto gave a classification accuracy for sugar cane about 10% higher as compared to the original images.

Dejesusparada, N.↗

Radiation Detection Technologies

When governing bodies seek to reduce the spread and development of nuclear material and weapons, arms control and safeguards technologies play an important role in preventing proliferation within a state that has already developed a nuclear weapon. Arms control treaties work to control the development, production, stockpiling, proliferation, distribution, or the usage of a certain weapon type or delivery system. Treaty guidelines are met using combinations of monitoring, detection, and verification technologies. 1 To verify compliance, a country must determine if the activities of another country are within the limits and obligations established by the treaty. A verifiable treaty contains an interlocking web of constraints and provisions designed to deter cheating, to make cheating more complicated and more expensive, or to make its detection timelier. In the past, the U.S. has deemed treaties to be effectively verifiable if there is confidence that significant violations can be detected in time to respond and offset any threat that the violation may create for the U.S.

61 RADIATION PROTECTION AND DOSIMETRY↗

Influence of carrier trapping on radiation detection properties in $\mathrm{CVD}$ grown 4H-SiC epitaxial layers with varying thickness up to 250 µm

We report low doped n-type 4H-SiC epitaxial layers of thickness 50, 150, and 250 µm grown by hot wall chemical vapor deposition were used to fabricate Ni/4H-SiC Schottky radiation detectors. The epitaxial layers were grown on the (0001) face of highly conductive bulk 4H-SiC substrates 8° offcut towards the $\langle 11\bar{2}1\rangle$ direction. The 50, 150, and 250 µm thick epilayer detectors, under optimized settings, showed energy resolutions of 2.0%, 0.78%, and 0.63%, respectively for 5.48 MeV alpha particles. Deep level transient spectroscopy studies showed that the observed variation in the detector resolution is linked to the defect parameters in the devices. Least-squares fitting of the bias dependence of the charge collection efficiency according to a drift-diffusion model, revealed minority carrier diffusion lengths of 16, 10, and 9.2 µm, respectively, implying that the detectors are not limited by minority carrier trapping. The detector performance was observed to be primarily dependent on the concentration and capture cross-sections of the lifetime killing electron traps Z 1/2 and EH 6/7 .

36 MATERIALS SCIENCE↗

Summary of Summer Project: Evaluating New Double Perovskite Halide Scintillators for Radiation Detection Applications

Project Outline: • Experimental validation of machine learning based prediction models; • Evaluating double perovskite halides (chlorides, some bromides) – A 2 bb'X 6 :Ce; A = Br + , Cs + ; B = Na + , K + ; B' = RE 3+ ; X = Cl - , Br - ; • Performing single crystal growth and characterization (physical, optical, scintillation properties).

61 RADIATION PROTECTION AND DOSIMETRY↗