Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ROTATING MIRROR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Point Relay Scanner Utilizing Ellipsoidal Mirrors

A scanning system uses a polygonal mirror assembly with each facet of the polygon having an ellipsoidal mirror located thereon. One focal point of each ellipsoidal mirror is located at a common point on the axis of rotation of the polygonal mirror assembly. As the mirror assembly rotates. a second focal point of the ellipsoidal mirrors traces out a scan line. The scanner can be utilized for scanned output display of information or for scanning information to be detected.

Manhart, Paul K.↗

Cosmology with liquid mirror telescopes

Liquid mirrors provide an exciting means to obtain large optical telescopes for substantially lower costs than conventional technologies. The liquid mirror concept has been demonstrated in the lab with the construction of a diffraction limited 1.5 m mirror. The mirror surface, using liquid mercury, forms a perfect parabolic shape when the mirror cell is rotated at a uniform velocity. A liquid mirror must be able to support a heavy mercury load with minimal flexure and have a fundamental resonant frequency that is as high as possible, to suppress the amplitude of surface waves caused by small vibrations transmitted to the mirror. To minimize the transmission of vibrations to the liquid surface, the entire mirror rests on an air bearing. This necessitates the mirror cell being lightweight, due to the limited load capabilities of the air bearing. The mirror components must also have physical characteristics which minimize the effects of thermal expansion with ambient temperature fluctuations in the observatory. In addition, the 2.7 m mirror construction is designed so that the techniques used may be readily extended to the construction of large mirrors. To attain the goals of a lightweight, rigid mirror, a composite laminant construction was used. The mirror consists of a foam core cut to the desired parabolic shape, with an accuracy of a few mm. An aluminum hub serves as an anchor for the foam and skin, and allows precise centering of the mirror on the air bearing and drive system. Several plys of Kevlar, covered in an epoxy matrix, are then applied to the foam. A final layer of pure epoxy is formed by spin casting. This final layer is parabolic to within a fraction of a mm. An aluminum ring bonded to the circumference of the mirror retains the mercury, and incorporates stainless-steel hard-points for the attachment of balance weights.

Hogg, David W.↗

Laser Oscillator Incorporating a Wedged Polarization Rotator and a Porro Prism as Cavity Mirror

A laser cavity was designed and implemented by using a wedged polarization rotator and a Porro prism in order to reduce the parts count, and to improve the laser reliability. In this invention, a z-cut quartz polarization rotator is used to compensate the wavelength retardance introduced by the Porro prism. The polarization rotator rotates the polarization of the linear polarized beam with a designed angle that is independent of the orientation of the rotator. This unique property was used to combine the retardance compensation and a Risley prism to a single optical component: a wedged polarization rotator. This greatly simplifies the laser alignment procedure and reduces the number of the laser optical components.

Li, Steven↗

Optical Testing of Diamond Machined, Aspheric Mirrors for Groundbased, Near-IR Astronomy

The Infrared Multi-Object Spectrometer (IRMOS) is a facility-class instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8-2.5 micron) spectrometer and operates at approximately 80 K. The 6061-T651 aluminum bench and mirrors constitute an athermal design. The instrument produces simultaneous spectra at low- to mid-resolving power (R=lambda/delta lambda= 300-3000) of approximately 100 objects in its 2.8 x 2.0 arcmin field. We describe ambient and cryogenic optical testing of the IRMOS mirrors across a broad range in spatial frequency (figure error, mid-frequency error, and microroughness). The mirrors include three rotationally symmetric, off-axis conic sections, one off-axis biconic, and several flat fold mirrors. The symmetric mirrors include convex and concave prolate and oblate ellipsoids. They range in aperture from 94x86 mm to 286x269 mm and in f-number from 0.9 to 2.4. The biconic mirror is concave and has a 94x76 mm aperture, R(sub x)=377 mm, k(sub x)=0.0778, R(sub y)=407 mm, and k(sub y)=0.1265 and is decentered by -2 mm in X and 227 mm in Y. All of the mirrors have an aspect ratio of approximately 6:1. The surface error fabrication tolerances are less than 10 nm RMS microroughness, 'best effort' for mid-frequency error, and less than 63.3 nm RMS figure error. Ambient temperature (approximately 293 K) testing is performed for each of the three surface error regimes, and figure testing is also performed at approximately 80 K. Operation of the ADE Phaseshift MicroXAM white light interferometer (micro-roughness) and the Bauer Model 200 profilometer (mid-frequency error) is described. Both the sag and conic values of the aspheric mirrors make these tests challenging. Figure testing is performed using a Zygo GPI interferometer, custom computer generated holograms (CGH), and optomechanical alignment fiducials. Cryogenic CGH null testing is discussed in detail. We discuss complications such as the change in prescription with temperature and thermal gradients. Correction for the effect of the dewar window is also covered. We discuss the error budget for the optical test and alignment procedure. Data reduction is accomplished using commercial optical design and data analysis software packages. Results from CGH testing at cryogenic temperatures are encouraging thus far.

Chambers, V. John↗

Bandwidth and threshold calculations for angle-tuned parametric oscillators.

The bandwidth of angle-tuned optical parametric oscillators, in some cases, is limited by the noncolinear interaction of the pump, signal, and idler beams, which results when the nonlinear material is rotated relative to the pump beam. To determine this bandwidth, a theoretical expression for the pump power threshold is derived in the near field limit taking into account double refraction for a noncolinear interaction. Angle tuning can be done by (1) rotating the crystal and mirrors as a unit, or by (2) rotating the crystal only. Expressions for determining the tuning rate and threshold increase for both tuning methods are derived.

Basu, R.↗

Economical Fabrication of Large Parabolic Mirrors

Long-focal-length parabolic mirrors fabricated economically by rotational casting. Technique applies to very large mirrors and incorporates new foam/fiberglass techniques ideal for producing rigid, lightweight mirrors. Process developed to produce mirrors that concentrate Sunlight for solarpumped laser.

Schneider, R. T.↗

Scan mirror remote temperature sensing system and method

A remote temperature sensing system (10) for a scanning mirror (7). The system (10) includes a sensor which detects heat radiated by the mirror and provides a signal in response thereto. In the illustrative implementation, the system (10) includes a thermistor mounted within a housing. The housing is contoured to maximize the receipt of thermal energy thereby. A mounting assembly maintains the thermistor a predetermined nonzero distance from the scanning mirror (7). The invention includes a shroud (12) mounted on the mirror (7) for shielding the thermistor and a support tube connected to the thermistor housing on a first end and to a base on the second end thereof. The support tube is adapted to remain stationary within the shroud as the scanning mirror and the shroud rotate due to the scanning of the mirror. Wires are connected to the thermistor on a first end thereof and are wrapped around the support tube. The wires include a length of electrically conductive material having a resistivity which has a low sensitivity to temperature variations. The sensor output is processed in a conventional manner to provide an output indicative of the temperature of the mirror.

VanDyk, Steven G.↗

Elevation scanning laser/multi-sensor hazard detection system controller and mirror/mast speed control components

The electro-mechanical and electronic systems involved with pointing a laser beam from a roving vehicle along a desired vector are described. A rotating 8 sided mirror, driven by a phase-locked dc motor servo system, and monitored by a precision optical shaft encoder is used. This upper assembly is then rotated about an orthogonal axis to allow scanning into all 360 deg around the vehicle. This axis is also driven by a phase locked dc motor servo-system, and monitored with an optical shaft encoder. The electronics are realized in standard TTL integrated circuits with UV-erasable proms used to store desired coordinates of laser fire. Related topics such as the interface to the existing test vehicle are discussed.

Craig, J.↗

The Impact of the AIRS Spatial Response on Channel-to-Channel and Multi-Instrument Data Analyses

The Atmospheric Infrared Sounder (AIRS) measures the infrared spectrum in 2378 channels between 3.7 and 15.4 microns with a very high spectral resolution of approximately 1200. AIRS footprints are approximately 1.1 by 0.6 degrees. Because AIRS is a grating spectrometer, each channel has a unique spatial response. Image rotation due to the scan mirror causes these spatial responses to rotate. In effect, each channel has 90 spatial responses, one for each scene footprint in the scan line. Although the spatial response for most channels is symmetric and nearly uniform, some channels have significantly asymmetric response. This paper reviews and describes the prelaunch measurements that characterized the spatial response functions. Next, it describes the conversion of the ground-based results into footprint-specific response functions valid in flight. Then we describe the postlaunch validation of the measurements, including centroid location, axes orientations, and a check on the full two-dimensional response functions. This latter check involves comparison of AIRS data with that of the Moderate Resolution Imaging Spectrometer (MODIS), which flies on the same platform as AIRS. An important result is that AIRS/MODIS brightness temperature comparisons are significantly improved (scatter reduced) when the AIRS spatial response is explicitly taken into account. Finally, a status report is given on attempts to fully verify the prelaunch measurements by deriving the AIRS spatial response from flight data alone.

preflight calibaration↗

High Resolution X-Ray Explorer (HIREX)

SAO is involved in a study to determine the feasibility of building an orbiting telescope capable of resolving 7 km structure on the Sun. In order to achieve the required imaging the telescope must have a resolution 0.01 arcsec. This fact challenges the state of the art of orbiting telescopes in several areas: Mirror Figuring; Optical Metrology; Optical Mounting; Mirror Figure Control; System Alignment; Optical Stability; Observatory Pointing; and Image Stability. The telescope design concept is based on a 0.6 m Gregorian-style telescope with a 240 meter effective focal length. This is achieved with 2 mirrors supported at opposite ends of a 35 m space-deployable boom. The telescope mirrors are coated with multilayers designed to reflect a broad XUV passband. A third, small mirror, near the focal plane performs the function of selecting the narrow band that is finally imaged. Image stabilization to the 0.005 arcsec level is achieved by active control of the secondary mirror. The primary mirror is held unadjustably to the spacecraft, its pointing set by the spacecraft orientation. The secondary mirror is mounted on a 6-axis stage that permits its position to be changed to align the telescope in space. The stage is intended for intermittent adjustment, both because of its speed of travel, and the TBD alignment procedure. The third mirror is called the TXI (Tuneable X-ray Imager). It is mounted on a gimbal that permits it to be tipped over a 60 degree range, selecting between the individual wavelengths in the initial bandpass. It can also rotated completely out of the way to allow the full, broadband EUV flux to strike the focal plane. Finally, the focal plane assembly is designed to rotate on the outer edge of a circle centered on the TXI mirror rotation axis. This permits the focal plane to move to the location that the TXI redirects the light once it has been set to a given wavelength response. The Engineering Study is divided into the following areas: Mirror Fabrication and Metrology; Optical Layout-Trade Study between On-axis and Off-axis; Overall System Design; and Pointing Control/Image Stabilization. The observational goals of the mission are described in the Mission Requirements document. The work is being performed to the requirements called out in the Science Requirements document.

Goulb, Leon↗

Masks For Deposition Of Aspherical Optical Surfaces

Masks of improved design developed for use in fabrication of aspherical, rotationally symmetrical surfaces of mirrors, lenses, and lens molds by evaporative deposition onto rotating substrates. In deposition chamber, source and mask aligned with axis of rotation of substrate. Mask shadows source of rotating substrate. Azimuthal opening (as function of radius) in mask proportional to desired thickness (as function of radius) to which material deposited on substrate. Combination of improved masks and modern coating chambers provides optical surfaces comparable or superior to those produced by conventional polishing, computer-controlled polishing, replication from polished molds, and diamond turning, at less cost in material, labor, and capital expense.

Rogers, John R.↗

Tropospheric Wind Profile Measurements with a Direct Detection Doppler Lidar

Research has established the importance of global tropospheric wind measurements for large scale improvements in numerical weather prediction. In addition, global wind measurements provide data that are fundamental to the understanding and prediction of global climate change. These tasks are closely linked with the goals of the NASA Earth Science Enterprise and Global Climate Change programs. NASA Goddard has been actively involved in the development of direct detection Doppler lidar methods and technologies to meet the wind observing needs of the atmospheric science community. In this paper we describe a recently developed prototype wind lidar system using a direct detection Doppler technique for measuring wind profiles from the surface through the troposphere. This system uses a pulsed ND:YAG laser operating at 1064 nm as the transmitter. The laser pulse is directed to the atmosphere using a 40 cm diameter scan mirror. The portion of the laser energy backscattered from aerosols and molecules is collected by a 40 cm diameter telescope and coupled via fiber optics into the Doppler receiver. Single photon counting APD's are used to detect the atmospheric backscattered signal. The principle element of the receiver is a dual bandpass tunable Fabry Perot etalon which analyzes the Doppler shift of the incoming laser signal using the double edge technique. The double edge technique uses two high resolution optical filters having bandpasses offset relative to one another such that the 'edge' of the first filter's transmission function crosses that of the second at the half power point. The outgoing laser frequency is located approximately at the crossover point. Due to the opposite going slopes of the edges, a Doppler shift in the atmospheric backscattered laser frequency produces a positive change in signal for one filter and a negative change in the second filter. Taking the ratio of the two edge channel signals yields a result which is directly proportional to the component of the wind along the line-of-sight of the laser. Measuring the radial wind in several directions provides sufficient information to determine the true wind speed and direction. The lidar has operated from our laboratory at Goddard since June, 1997. Wind profiles have been obtained to altitudes of 12 km with a vertical resolution of 330 in. Vector wind data are obtained by rotating the scan mirror to measure line-of-sight wind profiles for at least two azimuth angles at an elevation angle of 45 degrees. The precision of the data as determined from the standard deviation of multiple independent lidar profiles is in the range of 1 to 3 m/sec up to 10 km. Good agreement is obtained when the lidar data are compared with the upper air rawinsonde soundings taken at Dulles airport. Examples of the wind lidar data will be presented along with a description of the instrument and future developments.

Gentry, Bruce M.↗

The optical slit sensor as a standard sensor for spacecraft attitude determination

The basic concept of an optical slit sensor as a standard altitude sensor is considered for any missions using a spinning spacecraft or where rotating sensors or mirrors could be used. Information available from a single sensor or from two sensors is analyzed. A standard slit sensor package is compared with the altitude package flown on the first synchronous meteorological satellite.

Wertz, J.↗

Surface reflectance measurements in the UV from an airborne platform. I

The reflectance of naturally occurring surfaces is measured from a twin engine Cessna 402B aircraft both spectrally (0.29-0.40 micron) with a compact double monochromator and broadband (0.29-1.2 micron) with a UV enhanced photodiode. The measurement system, which is computer controlled and electrically isolated from the aircraft, consists of upward and downward looking hemispheric diffusers, filters, a rotating 90 deg mirror, a focusing lens, and a double monochromator/PMT or the UV photodiode. Measurements are taken at several altitudes enabling the empirical determination of backscatter and attenuation effects on the reflectance. The results are presented for pine forest canopy, green farmland, open ocean, and brown farmland as a function of wavelength and altitude.

Doda, D. D.↗

Surface reflectance measurements in the ultraviolet from an airborne platform. II

The spectral and broadband reflectance of naturally occurring desert sand, black lava, gypsum sand, and snow cover is measured from a twin engine Cessna 402-series aircraft. The measurement system is computer controlled and electrically isolated from the aircraft. It consists of upward and downward looking hemispheric diffusers, filters, a rotating 90 degree mirror, a focusing lens, and a double monochromator/PMT or a UV enhanced photodiode. Measurements are made at several altitudes enabling the empirical determination of the backscatter and attenuation effects on the reflectance. These reflectance results along with those reported earlier for a pine forest, green farmland, the open ocean, and brown farmland are represented analytically.

Doda, D. D.↗

Improved Skin Friction Interferometer

An improved system for measuring aerodynamic skin friction which uses a dual-laser-beam oil-film interferometer was developed. Improvements in the optical hardware provided equal signal characteristics for each beam and reduced the cost and complexity of the system by replacing polarization rotation by a mirrored prism for separation of the two signals. An automated, objective, data-reduction procedure was implemented to eliminate tedious manual manipulation of the interferometry data records. The present system was intended for use in two-dimensional, incompressible flows over a smooth, level surface without pressure gradient, but the improvements discussed are not limited to this application.

Westphal, R. V.↗

Accelerations in Flight

This report deals with the accelerations obtained in flight on various airplanes at Langley Field for the purpose of obtaining the magnitude of the load factors in flight and to procure information on the behavior of an airplane in various maneuvers. The instrument used in these tests was a recording accelerometer of a new type designed by the technical staff of the National Advisory Committee for Aeronautics. The instrument consists of a flat steel spring supported rigidly at one end so that the free end may be deflected by its own weight from its neutral position by any acceleration acting at right angles to the plane of the spring. This deflection is measured by a very light tilting mirror caused to rotate by the deflection of the spring, which reflected the beam of light onto a moving film. The motion of the spring is damped by a thin aluminum vane which rotates with the spring between the poles of an electric magnet. Records were taken on landings and takeoffs, in loops, spins, spirals, and rolls.

Norton, F H↗

Lidar Remote Sensing System

A lidar remote sensing system wherein a laser signal is transmitted along an optical path through a telescope having a primary and secondary mirrors and a rotating prism at the telescope output. When the reflected signal from the target is received it is passed back through the system to a detector, where it is heterodyned with a signal from a local oscillator to detect Doppler frequency shifts in the returned signal. Since the prism is rotating, the prism will be at one position when the signal is transmitted and at another when the returned signal is received. This causes the reflected signal to be off the optical path, reducing the power of the returned signal. To correct this problem a de-rotator or prism is mounted for rotation, in synchronism with the rotating prism. about the optical path in a position to intersect the returned beam and refract it back onto the optical path to reduce the power loss in the returned signal.

Michael J Kavaya↗