Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RODENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Effects of Cage Type and NASA Rodent Food Bar in Male Sprague-Dawley Rats

Early prototype caging for the rodent Advanced Animal Habitat (P-AAH) for the International Space Station (ISS) is currently being tested. In this five week study, effects of the wire-bottom P-AAH cages and specialized NASA rodent food bars (FB) were compared to standard vivarium cages (VIV) with corn-cob, litter-filled bottoms, and standard Purina rat chow (CH). Ninety-six male Sprague-Dawley rats were divided into four treatment groups (24 rats/treatment): Group 1) VIV+CH, Group 2) P-AAH+CH, Group 3) VIV+FB, and Group 4) P-AAH+FB. Each VIV and P-AAH cage housed three and six rats, respectively. After five weeks of treatment rats were weighed, euthanized, and blood samples were collected. Weights of liver (LIV), kidney (KID), brain (BRN), epididymal fat (EPI), and perirenal fat (PERI) were also measured. Statistical analysis to compare differences between groups was performed by standard analysis of variance procedures (ANOVA) with a significance level of pLO.05. Results indicated P-AAH housed rats had significantly lower body weights (BW), LIV weights, and LIV/BW than VIV housed rats. FB fed rats had significantly lower blood urea nitrogen (BUN) levels and LIV/BW than CH fed rats. In addition, FB fed rats had significantly higher cholesterol (CHOL) levels, EPI/BW, PERI/BW, and total fat (EPI+PERI)/BW than CH fed rats. The P-AAH+FB group had significantly lower EPI, BRN, and total fat than VIV+FB rats. VIV+FB rats had significantly higher BRN, EPI, PERI, and total fat than VIV+CH rats. Triglycerides (TG), KID, KID/BW, and BRN/BW were not significantly different among treatment groups. These findings provide valuable information regarding cage design and food bar suitability for long-term use on the ISS.

Lau, Angela↗

Rodent Biocompatibility Test Using the NASA Foodbar and Epoxy EP21LV

Epoxy has been used successfully to affix NASA foodbars to the inner walls of the Animal Enclosure Module for past space flight experiments utilizing rodents. The epoxy used on past missions was discontinued, making it necessary to identify a new epoxy for use on the STS-108 and STS-107 missions. This experiment was designed to test the basic biocompatibility of epoxy EP21LV with male rats (Sprague Dawley) and mice (Swiss Webster) when applied to NASA foodbars. For each species, the test was conducted with a control group fed untreated foodbars and an experimental group fed foodbars applied with EP21LV. For each species, there were no group differences in animal health and no statistical differences (P<0.05) in body weights throughout the study. In mice, there was a 16% increase in heart weight in the epoxy group; this result was not found in rats. For both species, there were no statistical differences found in other organ weights measured. In rats, blood glucose levels were 15% higher and both total protein and globulin were 10% lower in the epoxy group. Statistical differences in these parameters were not found in mice. For both species, no statistical differences were found in other blood parameters tested. Food consumption was not different in rats but water consumption was significantly decreased 10 to 15% in the epoxy group. The difference in water consumption is likely due to an increased water content of the epoxy-treated foodbars. Finally, both species avoided consumption of the epoxy material. Based on the global analysis of the results, the few parameters found to be statistically different do not appear to be a physiologically relevant effect of the epoxy material, We conclude that the EP21LV epoxy is biocompatible with rodents.

Tillman, J.↗

Pulmonary Toxicity Studies of Lunar Dusts in Rodents

NASA will build an outpost on the lunar surface for long-duration human habitation and research. The surface of the Moon is covered by a layer of fine, reactive dust, and the living quarters in the lunar outpost are expected to be contaminated by lunar dust. Because the toxicity of lunar dust is not known, NASA has tasked its toxicology laboratory to evaluate the risk of exposure to the dust and to establish safe exposure limits for astronauts working in the lunar habitat. Studies of the pulmonary toxicity of a dust are generally done first in rodents by intratracheal/intrapharyngeal instillation. This toxicity screening test is then followed by an inhalation study, which requires much more of the test dust and is labor intensive. Preliminary results obtained by examining lung lavage fluid from dust-treated mice show that lunar dust was somewhat toxic (more toxic than TiO2, but less than quartz dust). More extensive studies are in progress to further examine lung lavage fluid for biomarkers of toxicity and lung tissues for histopathological lesions in rodents exposed to aged and activated (ground) lunar dust samples. In these studies, reference dusts (TiO2 and quartz) of known toxicities and have industrial exposure limits will be studied in parallel so the relative toxicity of lunar dust can be determined. The results from the instillation studies will be useful for choosing exposure concentrations for the animal inhalation study. The animal inhalation exposure will be conducted with lunar dust simulant prior to the study with the lunar dust. The experiment with the simulate will ensure that the study techniques used with actual lunar dust will be successful. The results of instillation and inhalation studies will reveal the toxicological risk of exposures and are essential for setting exposure limits on lunar dust for astronauts living in the lunar habitat.

Lam, Chiu-wing↗

Maximizing Science Return from Future Rodent Experiments on the International Space Station (ISS): Tissue Preservation

To better understand how mammals adapt to long duration habitation in space, a system for performing rodent experiments on the ISS is under development; Rodent Research-1 is the first flight and will include validation of both on-orbit animal support and tissue preservation. To evaluate plans for on-orbit sample dissection and preservation, we simulated conditions for euthanasia, tissue dissection, and prolonged sample storage on the ISS, and we also developed methods for post-flight dissection and recovery of high quality RNA from multiple tissues following prolonged storage in situ for future science. Mouse livers and spleens were harvested under conditions that simulated nominal, on-orbit euthanasia and dissection operations including storage at -80 C for 4 months. The RNA recovered was of high quality (RNA Integrity Number, RIN(is) greater than 8) and quantity, and the liver enzyme contents and activities (catalase, glutathione reductase, GAPDH) were similar to positive controls, which were collected under standard laboratory conditions. We also assessed the impact of possible delayed on-orbit dissection scenarios (off-nominal) by dissecting and preserving the spleen (RNAlater) and liver (fast-freezing) at various time points post-euthanasia (from 5 min up to 105 min). The RNA recovered was of high quality (spleen, RIN (is) greater than 8; liver, RIN (is) greater than 6) and liver enzyme activities were similar to positive controls at all time points, although an apparent decline in select enzyme activities was evident at the latest time (105 min). Additionally, various tissues were harvested from either intact or partially dissected, frozen carcasses after storage for approximately 2 months; most of the tissues (brain, heart, kidney, eye, adrenal glands and muscle) were of acceptable RNA quality for science return, whereas some tissues (small intestine, bone marrow and bones) were not. These data demonstrate: 1) The protocols developed for future flight experiments will support science return despite delayed preservation post-euthanasia or prolonged storage, and 2) Many additional tissues for gene expression analysis can be obtained by dissection following prolonged storage of the tissue in situ at -80 C. These findings have relevance both to high value, ground-based experiments when sample collection capability is severely constrained, and to all future spaceflight experiments that entail on-orbit sample recovery by the ISS crew.

tissues↗

Evaluation of Rodent Spaceflight in the NASA Animal Enclosure Module for an Extended Operational Period (up to 35 days)

The National Aeronautics and Space Administration Animal Enclosure Module (AEM) was developed as a self-contained rodent habitat for shuttle flight missions that provides inhabitants with living space, food, water, ventilation, and lighting for shuttle flight missions, and this study reports whether, after minimal hardware modification, the AEM could support an extended term up to 35 days for Sprague-Dawley rats and C57BL/6 female mice for use on the International Space Station. Success was evaluated based on comparison of AEM housed animals to that of vivarium housed and to normal biological ranges through various measures of animal health and well-being, including animal health evaluations, animal growth and body masses, organ masses, rodent food bar consumption, water consumption, and analysis of blood contents. The results of this study confirmed that the AEMs could support 12 adult female C57BL/6 mice for up to 35 days with self-contained RFB and water, and the AEMs could also support 5 adult male Sprague-Dawley rats for 35 days with external replenishment of diet and water. This study has demonstrated the capability and flexibility of the AEM to operate for up to 35 days with minor hardware modification. Therefore, with modifications, it is possible to utilize this hardware on the International Space Station or other operational platforms to extend the space life science research use of mice and rats.

Animal enclosure module↗

Maximizing Science Return from Future Rodent Experiments on the International Space Station (ISS): Tissue Preservation

To better understand how mammals adapt to long duration habitation in space, a system for performing rodent experiments on the ISS is under development. Rodent Research-1 is the first flight and will include validation of both on-orbit animal support and tissue preservation. To evaluate plans for on-orbit sample dissection and preservation, we simulated conditions for euthanasia, tissue dissection, and prolonged sample storage on the ISS, and we also developed methods for post-flight dissection and recovery of high quality RNA from multiple tissues following prolonged storage in situ for future science return. Livers and spleens from mice were harvested under conditions that simulated nominal, on-orbit euthanasia and dissection procedures including storage at minus 80 degrees Centigrade for 4 months. The RNA recovered was of high quality (RNA Integrity Number, RNA Integrity Number (RIN) greater than 8) and quantity, and the liver enzyme contents and activities (catalase, glutathione reductase, GAPDH) were similar to positive controls, which were collected under standard laboratory conditions. We also assessed the impact of possible delayed on-orbit dissection scenarios (off-nominal) by dissecting and preserving the spleen (RNA, later) and liver (fast-freezing) at various time points post-euthanasia (from 5 minutes up to 105 minutes). The RNA recovered was of high quality (spleen, RIN greater than 8; liver, RIN greater than 6) and liver enzyme activities were similar to positive controls at all time points, although an apparent decline in select enzyme activities was evident at 105 minutes. Additionally, various tissues were harvested from either intact or partially dissected, frozen carcasses after storage for approximately 2 months; most of the tissues (brain, heart, kidney, eye, adrenal glands and muscle) were of acceptable RNA quality for science return, whereas some tissues (small intestine, bone marrow and bones) were not. These data demonstrate: 1) The protocols developed for future flight experiments will support science return despite delayed preservation post-euthanasia or prolonged storage, and 2) High-quality RNA samples from many different tissues can be recovered by dissection following prolonged storage of the tissue in situ at minus 80 degrees Centigrade. These findings have relevance both to high-value, ground-based experiments when sample collection capability is severely constrained, and to future spaceflight experiments that entail on-orbit sample recovery by the ISS crew.

tissues↗

Potential NASA Rodent Centrifuge

This presentation is a summary of the continuing effort to determine options for studying artificial gravity with rodents. Results of an engineering trade study are presented and an overview of past and planned short radius centrifugation studies are presented. A leading proposal for a future flight centrifuge capable of housing rodents, the Techshot RCF, is presented in only enough detail as is approved by Techshot for public domain use.

Donovan, Frances↗

Characterization of Sensory and Shelter Enrichment in the Rodent Research Habitat

The ISS provides a platform for conducting Rodent Research (RR) in microgravity and 9 missions have been successfully conducted. The results from these experiments have begun to provide new insights into the effects of spaceflight on mammalian physiological systems. After RR-1-4, the Flight IACUC required inclusion of additional cage enrichment into the Rodent Habitats (RH) to "enhance animal well-being by providing animals with sensory and motor stimulation, through structures and resources that facilitate the expression of species typical behaviors". A Hut, in the form of a rigid, mesh igloo-like shelter was implemented beginning with RR-5. The potential influence of the Hut in the novel cage environment of RH on various spaceflight-sensitive physiological systems has not been fully explored. To understand the effects of the Hut, mice (female C57Bl/6J, 15wks) were housed in Vivarium cage (n=5), RH with Hut (n=5), No Hut (n=5), Nestlet (n=10), and Cocoon (n=10) for 7 weeks. There were no differences in weekly body mass or food consumption. Tail blood draw indicated no differences in plasma corticosterone levels, immune cell types, or IgA levels. 24hrs prior to euthanasia, Open Field (OF) and Novel Object (NO) tests were performed. There were no differences across groups, all mice engaged in thigmotaxis (arena wall proximity) in the OF over 50% of the recorded time, and thigmotaxis declined when a NO was introduced. Additional behavioral analysis from daily videos are in progress to quantify activity levels. Post-euthanasia, there were no differences in soleus muscle or adrenal gland mass. Analysis of distal femur cancellous revealed some differences in microarchitecture. These results show that introduction of the Hut may diminish differences observed between spaceflight and ground controls, warranting improved validation of Hut effects in space, and also underscore the value of thorough preflight, ground based testing.

Shirazi-Fard, Yasaman↗

Rodent Research Capabilities Update

Space Biology current Rodent Research hardware and capabilities as of October 2017. These include the Life Sciences Glovebox, Rapid Freeze, sample cartridges and simulated carcass freezing, mass measurement device, habitat configuration with enrichment, and the non-Rodent capabilities they feature.

Leveson-Gower, Dennis↗

Environmental Enrichment in the ISS Rodent Habitat Hardware System

Responses of animals exposed to microgravity during in-space experiments were reviewed from NASAs and ESA available video recording archives. These documented observation of animal behavior, as well as the range and level of activities during spaceflight, clearly demonstrate that weightlessness conditions and the extreme novelty of the surroundings exert damaging psychological stresses on the inhabitants. In response to a recognized need for in-flight animals to improve their wellbeing we propose to reduce such stresses by shaping and interrelating structures and surroundings to satisfying vital physiological needs of inhabitants. Rodent Habitat Hardware System based housing facility incorporating a tubing network system, to maintain and monitor rodent health environment with advanced accessories has been proposed. The new tubing configuration was found suitable for further incorporation of innovative monitoring technology and accessories in the animal holding habitat unit which allow to monitor in real-time the most valuable health related biological parameter under weightlessness environment of spaceflight.

Orr, Sophie↗

A possible mechanism for the decrease in serum thyroxine level by phenobarbital in rodents

Effects of phenobarbital (PB) on the levels of serum thyroid hormones such as total thyroxine (T{sub 4}) and triiodothyronine were examined in male mice, hamsters, rats, and guinea pigs. One day after the final administration of PB (80 mg/kg, intraperitoneal, once daily for 4 days), significant decreases in the levels of the serum total T{sub 4} and free T{sub 4} occurred in mice, hamsters, and rats, while a significant decrease in the level of serum triiodothyronine was observed in hamsters and rats among the animals examined. In addition, a significant decrease in the level of serum thyroid-stimulating hormone was observed in only hamsters among the rodents examined. Significant increases in the level and activity of hepatic T{sub 4}-UDP-glucuronosyltransferase (UGT1A) after the PB administration occurred in mice, hamsters, and rats, while the increase in the amount of biliary [{sup 125}I]T{sub 4}-glucuronide after an intravenous injection of [{sup 125}I]T{sub 4} to the PB-pretreated animals occurred only in rats. In mice, rats, and hamsters, but not guinea pigs, PB pretreatment promoted the clearance of [{sup 125}I]T{sub 4} from the serum, led to a significant increase in the steady-state distribution volumes of [{sup 125}I]T{sub 4}, and raised the concentration ratio (Kp value) of the liver to serum and the liver distribution of [{sup 125}I]T{sub 4}. The present findings indicate that the PB-mediated decreases in the serum T{sub 4} level in mice, hamsters, and rats, but not guinea pigs, occur mainly through an increase in the accumulation level of T{sub 4} in the liver.

60 APPLIED LIFE SCIENCES↗

Tissue-specific in vivo genetic toxicity of nine polycyclic aromatic hydrocarbons assessed using the Muta™Mouse transgenic rodent assay

Test batteries to screen chemicals for mutagenic hazard include several endpoints regarded as effective for detecting genotoxic carcinogens. Traditional in vivo methods primarily examine clastogenic endpoints in haematopoietic tissues. Although this approach is effective for identifying systemically distributed clastogens, some mutagens may not induce clastogenic effects; moreover, genotoxic effects may be restricted to the site of contact and/or related tissues. An OECD test guideline for transgenic rodent (TGR) gene mutation assays was released in 2011, and the TGR assays permit assessment of mutagenicity in any tissue. This study assessed the responses of two genotoxicity endpoints following sub-chronic oral exposures of male Muta™Mouse to 9 carcinogenic polycyclic aromatic hydrocarbons (PAHs). Clastogenicity was assessed via induction of micronuclei in peripheral blood, and mutagenicity via induction of lacZ transgene mutations in bone marrow, glandular stomach, small intestine, liver, and lung. Additionally, the presence of bulky PAH-DNA adducts was examined. Five of the 9 PAHs elicited positive results across all endpoints in at least one tissue, and no PAHs were negative or equivocal across all endpoints. All PAHs were positive for lacZ mutations in at least one tissue (sensitivity = 100%), and for 8 PAHs, one or more initial sites of chemical contact (i.e., glandular stomach, liver, small intestine) yielded a greater response than bone marrow. Five PAHs were positive in the micronucleus assay (sensitivity = 56%). Furthermore, all PAHs produced DNA adducts in at least one tissue. The results demonstrate the utility of the TGR assay for mutagenicity assessment, especially for compounds that may not be systemically distributed. - Highlights: • The Muta™Mouse is a reliable tool for in vivo mutagenicity assessment of PAHs. • All 9 PAHs induced lacZ transgene mutations in small intestine. • Only 5 of 9 PAHs induced lacZ mutations and micronuclei in haematopoietic tissue. • Tissue-specific results are likely related to metabolism, repair, and proliferation. • For oral exposures, it is important to examine effects at the site-of-contact.

60 APPLIED LIFE SCIENCES↗

WE-F-16A-04: Micro-Irradiator Treatment Verification with High-Resolution 3D-Printed Rodent-Morphic Dosimeters

Purpose: Pre-clinical micro-radiation therapy studies often utilize very small beams (∼0.5-5mm), and require accurate dose delivery in order to effectively investigate treatment efficacy. Here we present a novel high-resolution absolute 3D dosimetry procedure, capable of ∼100-micron isotopic dosimetry in anatomically accurate rodent-morphic phantoms Methods: Anatomically accurate rat-shaped 3D dosimeters were made using 3D printing techniques from outer body contours and spinal contours outlined on CT. The dosimeters were made from a radiochromic plastic material PRESAGE, and incorporated high-Z PRESASGE inserts mimicking the spine. A simulated 180-degree spinal arc treatment was delivered through a 2 step process: (i) cone-beam-CT image-guided positioning was performed to precisely position the rat-dosimeter for treatment on the XRad225 small animal irradiator, then (ii) treatment was delivered with a simulated spine-treatment with a 180-degree arc with 20mm x 10mm cone at 225 kVp. Dose distribution was determined from the optical density change using a high-resolution in-house optical-CT system. Absolute dosimetry was enabled through calibration against a novel nano-particle scintillation detector positioned in a channel in the center of the distribution. Results: Sufficient contrast between regular PRESAGE (tissue equivalent) and high-Z PRESAGE (spinal insert) was observed to enable highly accurate image-guided alignment and targeting. The PRESAGE was found to have linear optical density (OD) change sensitivity with respect to dose (R{sup 2} = 0.9993). Absolute dose for 360-second irradiation at isocenter was found to be 9.21Gy when measured with OD change, and 9.4Gy with nano-particle detector- an agreement within 2%. The 3D dose distribution was measured at 500-micron resolution Conclusion: This work demonstrates for the first time, the feasibility of accurate absolute 3D dose measurement in anatomically accurate rat phantoms containing variable density PRESAGE material (tissue equivalent and bone equivalent). This method enables precise treatment verification of micro-radiation therapies, and enhances the robustness of tumor radio-response studies. This work was supported by NIH R01CA100835.

60 APPLIED LIFE SCIENCES↗

SU-E-I-84: Accuracy Comparison of Multi-Modality Image-Based Volumes of Rodent Solid Tumors Using In-Air Micro-CT Image Volume

Purpose: Tumor volume is considered as a better predictor for therapy response monitoring and tumor staging over Response Evaluation Criteria In Solid Tumors (RECIST) or World Health Organization (WHO) criteria. In this study, the accuracy of subcutaneous rodent tumor volumes using preclinical magnetic resonance imaging (MRI), micro-computed tomography (micro-CT) and ultrasound (US) equipment and with an external caliper was compared using in-air micro-CT image volume of excised tumors determined as reference tumor volume in our prior study. Methods: MR, US and micro-CT images of subcutaneous SCC4 head and neck tumor xenografts were acquired 4, 6, 9, 11 and 13 days after tumor cell inoculation. Before MR and US scans, caliper measurements were made. After tumors were excised, in-air micro-CT imaging and ex vivo caliper measurements were performed. Tumor volumes were calculated using formula V = (π/6)*a*b*c where a, b and c are the maximum diameters in three perpendicular dimensions determined by the three image modalities and caliper, and compared with reference tumor volume by linear regression analysis as well as Bland-Altman plots. A one-way Analysis of Variance (ANOVA) test was also performed to compare volumes among caliper measurements. Results: The correlation coefficients (R2) of the regression lines for tumor volumes measured by the three imaging modalities and caliper were 0.9939, 0.9669, 0.9806, 0.9274, 0.9619 and 0.9819 for MRI, US and micro-CT, caliperbeforeMRI, caliperbeforeUS and ex vivo caliper respectively. In Bland-Altman plots, the average of tumor volume difference from reference tumor volume (bias) was significant for caliper and micro- CT, but not for MRI and US. Comparison of caliper measurements showed a significant difference (p < 0.05). Conclusion: Using the in-air micro-CT image volume, tumor volume measured by MRI was the most accurate among the three imaging modalities. In vivo caliper volume measurements showed unreliability while ex vivo caliper measurements reduced errors.

60 APPLIED LIFE SCIENCES↗

Isolation and Characterization of Akhmeta Virus from Wild-Caught Rodents ( Apodemus spp.) in Georgia

In 2013, a novel orthopoxvirus was detected in skin lesions of two cattle herders from the Kakheti region of Georgia (country); this virus was named Akhmeta virus. Subsequent investigation of these cases revealed that small mammals in the area had serological evidence of orthopoxvirus infections, suggesting their involvement in the maintenance of these viruses in nature. In October 2015, we began a longitudinal study assessing the natural history of orthopoxviruses in Georgia. As part of this effort, we trapped small mammals near Akhmeta (n = 176) and Gudauri (n = 110). Here, we describe the isolation and molecular characterization of Akhmeta virus from lesion material and pooled heart and lung samples collected from five wood mice (Apodemus uralensis and Apodemus flavicollis) in these two locations. The genomes of Akhmeta virus obtained from rodents group into 2 clades: one clade represented by viruses isolated from A. uralensis samples, and one clade represented by viruses isolated from A. flavicollis samples. These genomes also display several presumptive recombination events for which gene truncation and identity have been examined.

59 BASIC BIOLOGICAL SCIENCES↗

OP3 NASA JAXA Rodent Research Collaboration Opportunities

Space Biology and Human Research Projects Integrated Proposal to use the JAXA MARS facility to be presented to JAXA and JAXA investigator audience at JAXA Kibo Utilization Symposium and OP3 negotiation for 2019 ISS rodent mission. Slides present a pictorial overview of the proposed science and analysis techniques desired from the US investigator team. Prior published data form a recent collaboration with JAXA is also mentioned.

JAXA Rodent Mouse Habitat Unit↗

RADIATION ECOLOGY ISSUES ASSOCIATED WITH MURINE RODENTS AND SHREWS IN THE CHERNOBYL EXCLUSION ZONE

This article describes major studies performed by the Chernobyl Center's International Radioecology Laboratory (Slavutich, Ukraine) on radioecology of murine rodents and shrews inhabiting the Chernobyl Exclusion Zone. The article addresses the long-term (1986-2005) and seasonal dynamics of radioactive contamination of animals, and reviews interspecies differences in radionuclide accumulations and factors affecting the radionuclide accumulations. It is shown that bioavailability of radionuclides in the 'soil-to-plant' chain and a trophic specialization of animals play key roles in determining their actual contamination levels. The total absorbed dose rates in small mammals significantly reduced during the years following the Chernobyl Nuclear Power Plant accident. In 1986, the absorbed dose rate reached 1.3-6.0 Gy hr{sup -1} in the central areas of the Chernobyl Exclusion Zone (the 'Red Forest'). In 1988 and 1990, the total absorbed dose rates were 1.3 and 0.42 Gy hr{sup -1}, respectively. In 1995, 2000, and 2005, according to the present study, the total absorbed dose rates rarely exceeded 0.00023, 0.00018, and 0.00015 Gy hr{sup -1}, respectively. Contributions of individual radiation sources into the total absorbed dose are described.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗