Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RETENTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Progress Summary: 12-Month Compression Set and Load Retention of Thermally Accelerated Aged Siloxane Specimens (Additively Manufactured by the Direct-Ink-Write (DIW) 3D Printing Technique) Was Measured

Motivation: Accelerated aging of polymeric materials is needed to predict their long-term mechanical functionality. Two key metrics used to evaluate their performance are compression set and load retention. A baseline(time=0)mechanical assessment was done prior to initiating the accelerated aging process to acquire initial thickness and load values for future calculation of compression set and load retention.Specimens are beingaged under compressive strain (13%for the current studies) at four different temperatures (25, 40, 55, and 70°C) for at least 1 year; compression set and load retention will be measured at various timepoints. Time-temperature superposition (TTS) will be applied to the isothermal data to obtain long-term predictions. Significance: Compression set is increasing with time and temperature, as expected. The increasing compression set is accompanied by decreasing load retention.The relativelylow compression set indicates the material is performing well.In a previous aging study, the legacy S5370 RTV foam exhibited 40% relative compression set after 12 months at 70°C, which is more than twice that of the DIW material. Progress:Data has been acquired out to the 12-month timepoint. Relative compression set and load retention versus time are shown in Fig. 1.A technical issue with the method of measuring load retention was discovered and previously reported load retention values have been adjusted; the current load retention values are estimates. TTS predictions are shown in Fig. 2.

36 MATERIALS SCIENCE↗

Initial Testing of an In Situ Load Retention Aging Vessel

A thermal aging vessel instrumented with load cells was fabricated. The primary function of the vessel is to continuously monitor the in situ load retention of up to three compressed polymer coupons undergoing thermally accelerated aging under nitrogen. A secondary function is to enable gas sampling of the vessel headspace during thermal aging. Heating of the vessel is achieved using a custom heater jacket. To improve upon our conventional aging study methods which require periodic interruption of aging to perform load testing in an Instron machine at room temperature, this technology aims to automate/facilitate data acquisition/analysis, improve data quality, and enable uninterrupted compression of the polymer which represents the service condition. As an example case to assess functionality of the in situ vessel, the load retention of a siloxane elastomer material additively manufactured by direct-ink-writing (DIW) was measured at three different isothermal aging temperatures for ~1 month. Initial compression of the coupons while near the aging temperature was achieved by temporarily opening the heated vessel to access the interior chamber and manually tightening four nuts to drive the heated compression plate down onto the heated coupons. Initial testing demonstrated achievement of the primary load retention monitoring function. Unfortunately, the vessel leaked which prevented gas sampling; an active purge was used to maintain a nitrogen atmosphere. Welded or otherwise sealed joints, which could be implemented in a future design, would likely eliminate leak paths. To apply time-temperature superposition (TTS), a technique used to provide long-term prediction of the load retention from short-term isothermal data, the load retention needed to be calculated relative to the load at an estimated “equilibrium” time, after most of the transient viscoelastic physical relaxation occurred. The peak load immediately after compression could not be used as the load retention basis for two reasons: (1) age-related changes must be isolated from non-age-related physical relaxation before applying TTS and (2) the manual mechanism used to compress the specimens at the aging temperature was neither smooth nor repeatable which affected the peak load value. To better understand the effect of the mode of initial compression on the measured load, and possibly better estimate “equilibrium” physical relaxation times, systematic stress relaxation experiments were performed using an Instron machine with a thermal chamber. At a given temperature, the DIW polymer was compressed to a fixed strain in either a stepped or continuous manner at two different rates, then held at that strain for 24 hrs. The results indicated that, at a given temperature, the different stress relaxation curves appeared to converge to the same curve at some “equilibrium” time when the non-age-related physical relaxation was mostly complete. Though this observation suggests that the discontinuous manual compression employed by the vessel is feasible, a compression mechanism that is rapid, smooth, and repeatable would enhance its use.

36 MATERIALS SCIENCE↗

The Association of Age-Related and Off-Target Retention with Longitudinal Quantification of [ 18 F]MK6240 Tau PET in Target Regions

6-(fluoro- 18 F)-3-(1H-pyrrolo[2,3-c]pyridin-1-yl)isoquinolin-5-amine ([ 18 F]MK6240) tau PET tracer quantifies the brain tau neurofibrillary tangle load in Alzheimer disease. The aims of our study were to test the stability of common reference region estimates in the cerebellum over time and across diagnoses and evaluate the effects of age-related and off-target retention on the longitudinal quantification of [ 18 F]MK6240 in target regions. Methods: We assessed reference, target, age-related, and off-target regions in 125 individuals across the aging and Alzheimer disease spectrum with longitudinal [ 18 F]MK6240 SUVs and SUV ratios (SUVRs) (mean ± SD, 2.25 ± 0.40 y of follow-up). We obtained SUVR from meninges, exhibiting frequent off-target retention with [ 18 F]MK6240. Additionally, we compared tracer uptake between 37 cognitively unimpaired young (CUY) (mean age, 23.41 ± 3.33 y) and 27 cognitively unimpaired older (CU) adults (amyloid-β–negative and tau-negative, 58.50 ± 9.01 y) to identify possible nonvisually apparent, age-related signal. Two-tailed t testing and Pearson correlation testing were used to determine the difference between groups and associations between changes in region uptake, respectively. Results: Inferior cerebellar gray matter SUV did not differ on the basis of diagnosis and amyloid-β status, cross-sectionally and over time. [ 18 F]MK6240 uptake significantly differed between CUY and CU adults in the putamen or pallidum (affecting ~75% of the region) and in the Braak II region (affecting ~35%). Changes in meningeal and putamen or pallidum SUVRs did not significantly differ from zero, nor did they vary across diagnostic groups. We did not observe significant correlations between longitudinal changes in age-related or meningeal off-target retention and changes in target regions, whereas changes in all target regions were strongly correlated. Conclusion: Inferior cerebellar gray matter was similar across diagnostic groups cross-sectionally and stable over time and thus was deemed a suitable reference region for quantification. Despite not being visually perceptible, [ 18 F]MK6240 has age-related retention in subcortical regions, at a much lower magnitude but topographically colocalized with significant off-target signal of the first-generation tau tracers. The lack of correlation between changes in age-related or meningeal and target retention suggests little influence of possible off-target signals on longitudinal tracer quantification. Nevertheless, the age-related retention in the Braak II region needs to be further investigated. Future postmortem studies should elucidate the source of the newly reported age-related [ 18 F]MK6240 signal, and in vivo studies should further explore its impact on tracer quantification.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fuel nozzle tube retention

A system for retaining a fuel nozzle premix tube includes a retention plate and a premix tube which extends downstream from an outlet of a premix passage defined along an aft side of a fuel plenum body. The premix tube includes an inlet end and a spring support feature which is disposed proximate to the inlet end. The premix tube extends through the retention plate. The spring retention feature is disposed between an aft side of the fuel plenum and the retention plate. The system further includes a spring which extends between the spring retention feature and the retention plate.

42 ENGINEERING↗

Effect of rhenium addition on deuterium retention in neutron-irradiated tungsten

In this work, the effects of rhenium (Re) addition on deuterium (D) retention in neutron-irradiated tungsten (W) were investigated. Pure W and W-5Re (5 at.%) alloy samples were irradiated with neutrons at High Flux Isotope Reactor using MFE-RB-19 J capsule. The sample temperature and the damage level were 864 K and 0.35 dpa for pure W and 792 K and 0.26 dpa for W-5Re alloy. A portion of the samples was exposed to D plasma at Tritium Plasma Experiment at Idaho National Laboratory at 823 K to a fluence of 5 × 1025 m -2 . Vacancy-type defects in neutron-irradiated samples were examined using positron annihilation spectroscopy (PAS); D retention after plasma exposure was evaluated by thermal desorption spectrometry (TDS). TDS measurements revealed that D retention in the neutron-irradiated W-5Re alloy was similar to that in the unirradiated W sample, whereas a significant increase in D retention was observed in neutron-irradiated W. Thus, Re addition significantly suppressed the increase in D retention after neutron irradiation. This effect was attributed to the suppression of vacancy-type defect formation, as confirmed by PAS.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Strong-Sludge Gas Retention and Release Mechanisms in Clay Simulants

The Hanford Site has 28 double-shell tanks (DSTs) and 149 single-shell tanks (SSTs) containing radioactive wastes that are complex mixes of radioactive and chemical products. The mission of the Department of Energy's River Protection Project is to retrieve and treat the Hanford tank waste for disposal and close the tank farms. A key aspect of the mission is to retrieve and transfer waste from the SSTs, which are at greater risk for leaking, into DSTs for interim storage until the waste is transferred to and treated in the Waste Treatment and Immobilization Plant. There is, however, limited space in the existing DSTs to accept waste transfers from the SSTs, and approaches to overcoming the limited DST space will benefit the overall mission. The purpose of this study is to summarize and analyze the key previous experiment that forms the basis for the relaxed controls and to summarize progress and results on new experiments focused on understanding the conditions that result in low gas retention. The previous large-scale test used about 50 m3 of sediment, which would be unwieldy for doing multiple parametric experiments. Accordingly, experiments began with smaller-scale tests to determine whether the desired mechanisms can be studied without the difficulty of conducting very large experiments. The most significant results from the current experiments are that progressively lower gas retention occurs in tests with progressively deeper sediment layers and that the method of gas generation also affects the maximum retention. Based on the results of this study, it is plausible that relatively low gas retention could occur in sufficiently deep tank waste in DSTs. The current studies and previous work, however, have not explored how gas retention and release will behave when two or more layers with different properties are present.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Water retention and gas relative permeability of two industrial concretes

This experimental study aims at identifying the water retention properties of two industrial concretes to be used for long term underground nuclear waste storage structures. Together with water retention, gas transfer properties are identified at varying water saturation level, i.e. relative gas permeability is assessed directly as a function of water saturation level S{sub w}. The influence of the initial de-sorption path and of the subsequent re-saturation are analysed both in terms of water retention and gas transfer properties. Also, the influence of concrete microstructure upon water retention and relative gas permeability is assessed, using porosity measurements, analysis of the BET theory from water retention properties, and MIP. Finally, a single relative gas permeability curve is proposed for each concrete, based on Van Genuchten-Mualem's statistical model, to be used for continuous modelling approaches of concrete structures, both during drying and imbibition.

36 MATERIALS SCIENCE↗

The influence of helium on deuterium retention in beryllium co-deposits

Tritium co-deposition with materials from the plasma-facing components is expected to be the main contributor to tritium retention in ITER. Since He will also be present in the plasma as fusion ash during the DT campaign, this study focuses on the effect of He on D retention in Be co-deposits. The PISCES-B linear plasma device was used to create co-deposited Be-D-He layers for various deposition temperatures (295 K - 475 K) and He concentrations in D - αHe plasma mixtures (0 ≤ α ≤ 0.1). Thermal desorption spectroscopy and nuclear reaction analysis were used to determine the D concentration in co-deposits. For the lowest He concentration (1%) an increase of D retention was observed for the deposition at room temperature, whereas for higher He concentrations a declining trend of D retention was found. Including 10% of He in the plasma is found to reduce D retention at deposition temperatures below 425 K and have a negligible effect at higher deposition temperatures.

36 MATERIALS SCIENCE↗

Deuterium retention in pre-lithiated samples and Li–D co-deposits in the DIII-D tokamak

Divertor designs involving liquid lithium have been proposed as an alternative to solid designs and wall conditioning techniques. However, Li affinity with tritium poses a risk for the fuel cycle. This study investigates deuterium retention in pre-lithiated samples and Li–D co-deposits in the DIII-D tokamak, making for the first time a direct comparison between Li–D co-deposits and pre-deposited Li films. Samples were exposed to H-mode plasmas in the far scrape-off layer (SOL), and Li powder was injected in-situ with the impurity powder dropper to study the uniformity of Li coatings, and the dependence of fuel retention on Li thickness. The results show that at temperatures below the melting point of lithium, deuterium retention is independent of the thickness of pre-deposited Li layers, with Li–D co-deposits being the primary factor for fuel retention. Both pre-deposited and in-situ deposited Li showed lower erosion than predicted by sputtering yield calculations. These results suggest that fuel retention in fusion reactors using lithium in the divertor will likely be dominated by co-deposits rather than in the divertor itself. If one desires to use Li to achieve flatter temperature profiles, operando Li injection is advantageous over pre-deposited Li films, at least at temperatures below the melting point of lithium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Influence of Microstructure on Deuterium Retention in Polycrystalline Tungsten

The retention of hydrogen isotopes in the plasma-facing materials of a fusion reactor is dependent on the density of trapping sites in the material. One factor that can influence the trapping defects is the surface state of the material before exposure. Mechanically polished, electropolished, and recrystallized tungsten samples were compared by exposing them to 350 eV D + beams with peak fluences of ~1 × 10 24 D + /m 2 at 500 and 740 K at the Multicharged Ion Research Facility (MIRF). At the exposure temperature of 740 K, no significant retention was detected. For material exposed at 500 K, significant differences in retention were observed, and the order of increasing retention was recrystallized, electropolished, and mechanically polished. Lastly, the other variable besides surface treatment was the time delay between ion exposure and thermal desorption spectroscopy which also may have impacted the retention measurements if there was out-gassing of the D while samples were in storage before thermal desorption spectroscopy (TDS).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of a Cr-rich surface layer on D retention in various RAFM steels

In this work, deuterium (D) retention is compared between various reduced-activation ferritic/martensitic steels, including CLF-1, Eurofer, F82H, and Rusfer, exposed to pure D plasma (ion flux ~1.5–2 × 10 21 m -2 s -1 , fluence, ϕ D , ~1 × 10 25 m -2 , sample temperature ~373 K, and incident ion energy ~100 eV). It is found that there is a large difference (up to ~30x) in the D retention between CLF-1 and F82H even with the same plasma exposure condition and similar nominal composition. The ϕ D dependence of the D retention exhibits a peculiar, counterintuitive feature: the D retention decreases with an increase in ϕ D from 2 × 10 23 m -2 to 1 × 10 25 m -2 . Surface analyses reveal that a Cr-rich surface layer is formed during outgassing at 773 K for 1 h before plasma exposure, and that there exists a clear correlation between the D retention and the Cr content in the surface layer.

36 MATERIALS SCIENCE↗

Oxygen plasma immersion ion implantation treatment to enhance data retention of tungsten nanocrystal nonvolatile memory

Data retention characteristics of tungsten nanocrystal (W-NC) memory devices using an oxygen plasma immersion ion implantation (PIII) treatment are investigated. With an increase of oxygen PIII bias voltage and treatment time, the capacitance–voltage hysteresis memory window is increased but the data retention characteristics become degraded. High-resolution transmission electron microscopy images show that this poor data retention is a result of plasma damage on the tunneling oxide layer, which can be prevented by lowering the bias voltage to 7 kV. In addition, by using the elevated temperature retention measurement technique, the effective charge trapping level of the WO{sub 3} film surrounding the W-NCs can be extracted. This measurement reveals that a higher oxygen PIII bias voltage and treatment time induces more shallow traps within the WO{sub 3} film, degrading the retention behavior of the W-NC memory.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Order-of-magnitude differences in retention of low-energy Ar implanted in Si and SiO{sub 2}

The retention of 1 and 5 keV Ar implanted at 45° in Si and 4.3 nm SiO{sub 2} on Si was studied at fluences between 3 × 10{sup 14} and 1.5 × 10{sup 16} cm{sup −2}. X-ray photoelectron spectroscopy (XPS) served to monitor the accumulation of Ar as well as the removal of SiO{sub 2}. Bombardment induced changes in oxygen chemistry caused the O 1s peak position to move toward lower binding energies by as much as 2.2 eV. Plotted versus depth of erosion, the fluence dependent changes in oxygen content, and peak position were similar at 1 and 5 keV. The Ar content of Si increased with increasing exposure, saturating at fluences of ∼2 × 10{sup 15} cm{sup −2} (1 keV) and ∼6 × 10{sup 15} cm{sup −2} (5 keV). Much less Ar was retained in the SiO{sub 2}/Si sample, notably at 1 keV, in which case the low-fluence Ar signal amounted to only 8% of the Si reference. The results imply that essentially no Ar was trapped in undamaged SiO{sub 2}, i.e., the Ar atoms initially observed by XPS were located underneath the oxide. At the lowest fluence of 5 keV Ar, the retention ratio was much higher (43%) because the oxide was already highly damaged, with an associated loss of oxygen. The interpretation was assisted by TRIM(SRIM) calculations of damage production. Partial maloperation of the ion beam raster unit, identified only at a late stage of this work, enforced a study on the uniformity of bombardment. The desired information could be obtained by determining x,y line scan profiles of O 1s across partially eroded SiO{sub 2}/Si samples. Fluence dependent Ar retention in Si was described using an extended version of the rapid relocation model which takes into account that insoluble implanted rare-gas atoms tend to migrate to the surface readily under ongoing bombardment. The range parameters required for the modeling were determined using TRIM(SRIM); sputtering yields were derived from the literature. The other three parameters determining the Ar signal, i.e., (1) the thickness w of the near-surface Si region devoid of Ar, (2) the relocation efficiency Ψ{sub rlc}, and (3) the effective attenuation length L in XPS analysis were varied within reasonable limits until the calculated retention curves for 1 and 5 keV Ar in Si agreed with experimental data to better than 8%, using the same XPS sensitivity factor throughout. Results: w = 1.4 ± 0.1 nm, Ψ{sub rlc} = 6.6 ± 0.5, and L = 2.7 ± 0.2 nm. Combining experimental and calculated data, it was found that the Ar trapping efficiency of the damaged oxide is intimately correlated with the loss of oxygen. The calculated stationary areal densities of all retained Ar are compared with results obtained by high-resolution medium-energy ion scattering spectrometry. Attractive areas of future research in rare gas retention and nanobubble formation are sketched briefly.

42 ENGINEERING↗

Regulatory Compliance of H Retention Basin Using Rhombo Balls - 16151

Elevated pH conditions in the Savannah River Site 281-8H Retention Basin will have to be resolved prior to the issuance of a new National Pollutant Discharge Elimination System permit. The 281-8H retention basin collects rain water runoff, cooling tower blow downs and steam condensate from H Area Tank Farm operation processes. The basin discharges to a South Carolina Department of Health and Environmental Control National Pollutant Discharge Elimination System permitted out-fall, H-12. The permit requires the out-fall to meet certain discharge requirements. The National Pollutant Discharge Elimination System permit requires the pH to be within the range 4.8 to 8.5. The 281-8H Retention Basin has a steady history of elevated pH levels, above 8.5, especially during the warmer months of the year, normally March through October. The rise in pH has been attributed to the exponential growth of algae which occurs during the warm months of the year. The increased algae colonies undergo photosynthesis which depletes the CO{sub 2} in the basin water and subsequently raises the pH level. The current permit allows simultaneous discharge of low pH well water, pH between 4.6 and 5.0, and the 281-8H Retention Basin water which provides blending to achieve regulatory compliance. The regulatory agency indicated in 2010 that adding well water to achieve compliance of pH limits will not be allowed when the new permit is issued in the future. Therefore, a solution to the high pH had to be identified and implemented in order to ensure regulatory compliance. A system engineering evaluation was conducted to determine the best solution to the large algae colonies and high pH levels. The evaluation identified options in four primary categories as well as some combination of those categories to control algae growth and to ultimately increase the amount of CO{sub 2} in the basin. Eleven evaluation criteria were developed for the various options, and a percentage (out of 100%) was assigned to related groups of criteria. Twenty-six options were evaluated during this process. The highest ranking options determined from the evaluation were the 12-sided Rhombo ball floating cover, biological digester and a combination of the digester and the floating cover. Option 3, a combination of the top two choices, was chosen as the best approach. The Rhombo cover along with the initial shock application of a biological digester has worked to eliminate algae growth and lower the pH level. The Rhombos have significantly lowered the basin pH level from greater than 9 to less than 7, which is within the regulatory compliance pH requirements of 4.8 to 8.5. The system engineering evaluation and subsequent solution chosen are useful in many venues. The application of the 12 sided Rhombo ball's unique ability to nestle together no matter which way they turn is advantageous to applications/problems that need to block 99.99% sunlight from a body of water. The 281-8H Retention Basin required nine 18 wheeler truckloads with trailers that were 16.2 m (53 Ft) long and filled with Rhombo balls. The basin required a total of approximately 700,000 Rhombo balls to be fully covered. They are easy to install and handle. The Rhombo balls have wind resistance up to 120 Km/hr (75 MPH) and have a life expectancy of 25 years. This application can be used to control plant and algae growth and is effective in evaporation reduction at 99%. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Temperature effects on adsorption and capillarity water retention mechanisms in constrained unsaturated soils

Abstract This paper focuses on the impact of elevated temperatures on the adsorptive and capillarity water retention mechanisms of unsaturated soils under constrained (constant volume) conditions. This topic is critical for simulating the thermo-hydraulic behavior of soils in hydrogeological or geotechnical applications, including climate change effects on near surface soils, energy piles or soil borehole thermal energy storage systems in unsaturated soil layers, and buffers for geological nuclear waste repositories. A nonisothermal soil water retention curve (SWRC) that separately considers the temperature-dependency of the key parameters governing adsorptive and capillarity water retention mechanisms and soil physical parameters (e.g., surface tension, contact angle, adsorption capacity, cation exchange capacity, mean cavitation suction, air entry value and equilibrium film thickness) was developed to provide insights into the impact of temperature on water retention over the full suction range. The nonisothermal SWRC was validated using experimental data on high plasticity clays, with a good prediction of temperature effects on adsorption and capillarity water retention mechanisms in constrained unsaturated soils.

Lu, Yu↗

Deuterium retention in advanced steels for fusion reactor structural application

Reduced activation ferritic-martensitic (RAFM) steels, castable nanostructured alloys (CNA), and oxide-dispersion-strengthened (ODS) steels have been developed for the fusion reactor structural application with improved mechanical properties and radiation resistance. However, the hydrogen isotope retention in these steels is not well understood. In this study, 10 keV D 2 implantation was performed on six steels, together with pure iron and T91 as references, at room temperature. Subsequent thermal desorption spectroscopy (TDS) measurements were carried out to investigate the deuterium retention. Possible deuterium trapping sites in the studied materials were discussed in coordination with available microstructural information. The results of this study indicated that ODS-steels have the largest deuterium retention, which is almost one order of magnitude higher than that of pure iron, ~6 times of RAFM, and 2–4 times of CNA steels. The difference in nanoparticles and grain/lath boundaries are primarily responsible for the different deuterium retention, while other trapping sites (e.g., vacancy clusters, dislocations, etc.) are present. Deuterium retention increases with increasing sink strength of the studied materials, although they are not linear correlated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Back to functional hydrides: Effects of neutron-irradiated microstructure on hydrogen retention in yttrium hydride

Functional hydrides are promising candidates for advanced nuclear reactors, particularly in portable or transportable applications, due to their high hydrogen-retention capabilities, enabling efficient neutron moderation, and compact reactor design. However, hydrogen mobility in hydrides at elevated irradiation temperatures poses significant technological challenges, necessitating a comprehensive understanding of their irradiation behavior. Furthermore, this study investigated the microstructural and chemical stability of neutron-irradiated yttrium hydrides to assess their hydrogen-retention capacity. A targeted literature review was also conducted to contextualize neutron-irradiation effects on functional hydrides with regards to structural stability and hydrogen retention. Experimental characterizations revealed that, at high temperatures, irradiated hydrides retained their phase stability, which was likely enhanced by irradiation-induced microstructure evolution. Notably, an amorphous yttrium and oxygen -rich surface layer was present at the free surface of the hydride. Its thickness decreased while a continuous crystalline Y-O-rich layer was formed with increasing neutron damage. Additionally, the number density of dislocation loops and cavities generally increased as a function of neutron dose. First-principles calculations of hydrogen behavior within yttrium vacancy clusters in yttrium hydrides demonstrated vacancy-size-dependent hydrogen stability and configuration, highlighting the role of vacancy geometry in regulating hydrogen retention. Thus, the presence of irradiation-induced dislocation loops and cavities were hypothesized to improve hydrogen retention. Collectively, these findings advance the understanding of hydride behavior under neutron irradiation as well as their technological readiness for portable or transportable nuclear reactors.

Defect clusters↗

High-resolution simulation of free-surface flow and tracer retention over streambeds with ripples

This study presents a novel high-resolution simulation of free-surface flow and tracer retention over a streambed with ripples based on varying ripple morphologies, surface hydraulics and the transport of a tracer pulse from surface water to surface dead zone. For the simulations, the computational fluid dynamics (CFD) model OpenFOAM was used to solve the three-dimensional Navier-Stokes equations in combination with an implemented transport equation. Pressure gradients at the streambed were used to account for hyporheic exchange, assuming water flow from high pressure zones to low pressure zones. Flow velocities, ripple sizes and spacing showed to significantly affect these pressure gradients, but also the transport of a passive tracer at the streambed, which was not investigated so far. Due to the velocity field, large parts of the tracer mass were transported alongside the main stream above the ripples. Tracer mass reaching the space between the ripples was temporarily retained due to low velocities and recirculations. It was shown that the retention is depending on the ripple size and space between the ripples as well as on the flow velocity. Decreasing ripple sizes and higher flow velocities lead to a smaller tracer retention. Furthermore we showed that the ripple length to height ratio controls the generation of recirculation zones which affect the residence time of the tracer significantly. Ripple spacing leads to temporarily higher tracer concentration at the streambed, but smaller tracer retention. We conclude that the impact of the streambed morphology on the hydraulics in combination with tracer retention should be addressed for a comprehensive understanding of compound movement, exchange and transformation within the hyporheic zone.

54 ENVIRONMENTAL SCIENCES↗