Engineering PapersSearch

SEARCH · Engineering Papers

Results for “RESIDUAL GAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The influence of gas velocity on surface heat pumping for the orifice pulse tube refrigerator

The basic pulse tube refrigerator produces cooling by a mechanism known as surface heat pumping. Cyclical compression and expansion of a gas within an enclosed tube produces large temperature gradients. The purpose of the tube is to act as 'nodal regenerator'. Heat is stored at node positions along the tube wall and is transported between nodes by moving gas parcels. This process gives rise to refrigeration, with hot temperatures at the closed end and cold temperatures at the open end. Unfortunately, much of the available refrigeration is not realized because the closed end of the basic pulse tube restricts gas movement - gas at the extreme temperatures does not come in contact with the heat exchangers. The orifice pulse tube overcomes this limitation by using a valve and surge volume assembly at the warm, closed end. This allows for a residual gas velocity to remain present during the heat transfer process, thereby permitting more gas to exchange heat at the heat exchangers. This paper describes the pulse tube as a nodal regenerator and the effect residual gas velocity has on the heat transfer mechanism of the orifice pulse tube.

Lee, J. M.

Single layer graphene protective layer on GaAs photocathodes for spin-polarized electron source

GaAs-based photocathodes are the primary choice for polarized electron sources, commonly used in polarized electron microscopes and polarized positron sources. GaAs photocathodes are typically activated with cesium and oxygen, which are highly reactive and require an ultra-high vacuum (⁠~ 10 -11 Torr or lower) to operate reliably, resulting in substantial operational difficulties. A short exposure to a mediocre vacuum results in an instantaneous loss of cathode quantum efficiency (QE) due to the chemical reaction of the active layer with residual gas molecules or back-bombardment ions during operation. Covering the GaAs cathode with a 2D material, such as monolayer graphene, could provide protection against such damage due to the inhibition of chemical reactions with residual gas molecules. In this paper, we have incorporated a method known as intercalation to pass the active material underneath the graphene and activate the superlattice GaAs/GaAsP (SL-GaAs) photocathode. X-ray photoelectron spectroscopy, low-energy electron microscopy, and Mott scattering measurements were performed to evaluate the formation of the photocathode under graphene, as well as its spectral response and electron spin polarization. Our results demonstrate that the successful activation of the SL-GaAs photocathode with a graphene protection layer is achieved with a moderate QE. Furthermore, we found that the electron spin polarization of the cathode with a surface protection layer is higher than the conventional cathode without a protection layer.

2D materials

Mass Flux of ZnSe by Physical Vapor Transport

Mass fluxes of ZnSe by physical vapor transport (PVT) were measured in the temperature range of 1050 to 1160 C using an in-situ dynamic technique. The starting materials were either baked out or distilled under vacuum to obtain near-congruently subliming compositions. Using an optical absorption technique Zn and Se, were found to be the dominant vapor species. Partial pressures of Zn and Se, over the starting materials at temperatures between 960 and 1140 C were obtained by measuring the optical densities of the vapor phase at the wavelengths of 2138, 3405, 3508, 3613, and 3792 A. The amount and composition of the residual gas inside the experimental ampoules were measured after the run using a total pressure gauge. For the first time, the experimentally determined partial pressures of Zn and Se, and the amount and composition of the residual gas were used in a one-dimensional diffusion limited analysis of the mass transport rates for a PVT system. Reasonable agreement between the experimental and theoretical results was observed.

Sha, Yi-Gao

Design of Ionization Profile Monitors at the Integrable Optics Test Accelerator Facility at Fermilab

The Integrable Optics Test Accelerator (IOTA) at Fermilab is transitioning from an electron beam facility to a proton beam facility for studies in nonlinear accelerator optics and space-charge dominated proton beams. This project involves the commissioning and fabrication of Ionization Profile Monitors (IPMs) to enable beam profile measurements at IOTA. In general, IPMs work on principle of residual gas ionization by the beam to generate beam profile. This work focuses on a mechanical design that leverages a controlled injection of noble gases, primarily Argon, as the ultra-high vacuum of the IOTA ring provides insufficient residual gas for ionization. Efforts to understand vacuum integration to ensure compatibility with the storage ring environment, the integration of real-time data acquisition systems and the commissioning of the IPMs will be discussed. This project provides a versatile diagnostic tool, supporting IOTA’s role as a testbed for larger-scale accelerator facilities and contributing to the broader understanding of beam physics in high-intensity, high-space-charge regimes.

Mwaniki, M. W. [IIT, Chicago] (ORCID:0000000169057

Investigation of Lunar Regolith Reduction via Hydrogen Plasma in Different Plasma Environments

The team at NASA KSC explored the use of hydrogen plasma as a reducing agent for Lunar regolith simulant in order to prove the viability of oxygen extraction from oxides. The focus of this work was to investigate the hydrogen ion production of different plasma power sources. An optimization trade study was completed by maximizing the production of the hydrogen ion and comparing the amount produced to the energy consumed. Hydrogen ion production was determined via residual gas analysis and a rough calibration using injected water. The hydrogen ions reduce the oxides present in the Lunar regolith, forming an OH molecule, which can further react with the hydrogen environment to form water vapor. This water vapor can then be measured through a residual gas analysis. Through this study, it was found that a direct current (DC) glow discharge operating at approximately 1 torr in a hydrogen environment produced the largest amount of reduced regolith when compared with a nanosecond pulsed system and alternating current (AC) source. Radiofrequency devices beyond AC were not studied in this work. Although the DC source performed the best here, limitations in design and experiment setup/scalability may lead to the selection of an alternative plasma power source in the future.

Kenneth Engeling

Physical vapor transport of mercurous chloride under a nonlinear thermal profile

Our study investigates numerically the flow field characteristics during the growth of mercurous chloride (Hg2Cl2) crystals in a rectangular ampoule under terrestrial and microgravity conditions for a nonlinear thermal gradient. With a residual gas lighter than the nutrient, the solutal Grashof number is dominant. We observe that in tilted configurations, when solutal convection is dominant, the maximum transport rate occurs at approximately 40 percent. For the vertical configurations, we were able to obtain solutions only for the cases either below the critical Rayleigh numbers or the stabilized configurations. The total mass flux decreases exponentially with an increase of pressure of residual gas, but it increases following a power law with the temperature difference driving the transport. The nonlinear thermal gradient appears to destabilize the flow field when thermal convection is dominant for both vertical top-heated and bottom-heated configurations. However, when the solutal Grashof number is dominant, the density gradient resulting from the solutal gradient appears to stabilize the flow for the bottom-heated configuration. The flow field for the top-heated configuration is destabilized for high Grashof numbers. The microgravity environment provides a means for lowering convection. For gravity levels of 10(exp -3) g(0) or less, the Stefan wind drives the flow, and no recirculating cell is predicted.

Mennetrier, Christophe

Operando XPS in reactive plasmas: The importance of the wall reactions

In this article, advancements in differential pumping and electron optics over the past few decades have enabled x-ray photoelectron spectroscopy (XPS) measurements at (near-)ambient pressures, bridging the pressure gap for characterizing realistic sample chemistries. Recently, we have demonstrated the capabilities of an ambient pressure XPS setup for in situ plasma environment measurements, allowing plasma-surface interactions to be studied in operando rather than using the traditional before-and-after analysis approach. This new “plasma-XPS” technique facilitates the identification of reaction intermediates critical for understanding plasma-assisted surface processes relevant to semiconductor nanomanufacturing, such as physical vapor deposition, etching, atomic layer deposition, and many other plasma applications. In this paper, we apply the plasma-XPS approach to monitor real-time surface chemical changes on a model Ag(111) single crystal exposed to oxidizing and reducing plasmas. We correlate surface-sensitive data with concurrent gas-phase XPS measurements and residual gas mass-spectrum analysis of species generated during plasma exposure, highlighting the significant role of plasma-induced chamber wall reactions. Ultimately, we demonstrate that plasma-XPS provides comprehensive insights into both surface and gas-phase chemistry, establishing it as a versatile and dynamic characterization tool with broad applications in microelectronics research. Finally, we outline potential enhancements and future metrology directions to advance plasma-XPS investigations further.

36 MATERIALS SCIENCE

Effect of NO on DME-Methanol HCCI Experimental Observations

Methanol is an attractive fuel for the maritime sector due to its wide availability. Its direct use as a fuel, however, is accompanied by challenges such as high latent heat of vaporization and low cetane number. A potential solution to overcome the ignition properties of methanol could be through on-board generation of dimethyl ether (DME) via catalytic dehydration of methanol. The resulting mixture from dehydration can be mixed in with the intake air to generate a homogenous charge compression ignition (HCCI) preburn for subsequent direct injection (DI) and successful ignition methanol at diesel–like timescales. However, if the preburn species are treated separately from the complete methanol MCCI approach the preburn heat release rate (HRR) phasing and behavior do not replicate the preburn behavior of the complete approach. Thus, the presence of the main methanol mixing controlled compression ignition (MCCI) combustion event influences the DME/methanol preburn kinetics. Specifically, it was found that trapped residual temperature alone was insufficient alone to be responsible for the observed differences, and that trace species concentrations of NO in the trapped residual gas also influenced DME/methanol kinetics increasing low temperature heat release (LTHR) magnitude and advancing high temperature heat release (HTHR) phasing. NO is not present in HCCI combustion of neat DME or DME/methanol blends nor is elevated gas temperature in the trapped residuals; both of which result in failure to accurately predict the HCCI combustion of DME/methanol blends when coupled with subsequent DI methanol MCCI. This work experimentally explores the effect of trapped residual temperature and NO on DME and DME/methanol HCCI combustion.

Jatana, Gurneesh [ORNL] (ORCID:0000000288903225)

Feasibility of fusion plasma burn control via real-time, sub-divertor neutral gas isotopic and compositional analysis

The ability to provide fusion burn control without requiring physical access through the first wall and fuel breeding blankets, would be vital for any future, magnetically confined fusion power reactor. A multi-sensor, fusion fuel cycle exhaust, neutral gas analysis system on JET, capable of delivering real time data, and accessing only the sub-divertor region, provides an excellent example of such capability. Optimized for and operated during the deuterium–tritium experimental campaigns 2 and 3 (DTE2, DTE3), it is proving valuable for planning to explore fusion reactor burn control in ITER with a comparable diagnostic system called the Diagnostic Residual Gas Analyzer (DRGA). This paper aims to show feasibility of developing model-based controllers for ITER and next generation, reactor-relevant devices, by building both on the empirical experience in JET-DTE2, and on the already emerging experience on developing such models specifically for ITER. The paper begins with a specific use-case from JET-DTE2, pertaining to the observed sensitivity of the fusion neutron yield on the concentration of isotopic helium-3 ( 3 He), with data from one of the high-performance DT shots exhibited with emphasis on the 3 He measurement via the sub-divertor. Then, a first model is developed and then explored with simulations that aim to discover how well the controllers in the model react to either insufficient levels of 3 He or excessive levels of 3 He. The simulations then explore potential impact from a delay in the measurement (or the response) that would be comparable to the ∼1 s, conductance limited response for the ITER DRGA system, currently in its final design. The simulations show that control is feasible, and that its effectiveness is not significantly impacted by such delay.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Hydrogen Analysis by Gas Chromatography–Mass Spectrometry

The detection of hydrogen in complex gas mixtures is essential for many applications. Conventional approaches such as gas chromatography (GC) with thermal conductivity detection (TCD) and residual gas analyzers (RGAs) face significant limitations: TCD exhibits poor response when helium is used as a carrier gas, whereas RGAs lack chromatographic separation, preventing reliable quantification of hydrogen because of interference from other species. Traditional GC methods rely on dual-column configurations with packed or molecular-sieve porous layer open tubular (PLOT) columns to separate hydrogen from O2, N2, CO, CO2, CH4, and other hydrocarbons, increasing system complexity and limiting compatibility with mass spectrometry (MS) detection. In this work, we developed and validated a robust GC–MS method capable of directly detecting and quantifying hydrogen using electron ionization (EI) without dopants, reagent gases, or ion–molecule reaction schemes. By integrating a modified EI source and a cryogenically cooled single capillary column configuration, we achieved baseline separation of hydrogen from all major permanent gases and hydrocarbons in a refinery gas mixture using helium as the carrier gas. The method demonstrated excellent linearity, high sensitivity, and exceptional reproducibility. Adjustable sample-loop volumes and split ratios enabled optimization of peak shape and signal-to-noise performance for trace-level and percent-level hydrogen concentrations. Beyond hydrogen quantitation, the method provides simultaneous compositional profiling of other gases in a mixture in a single run, making it valuable for a wide range of tasks.

Lobodin, Vlad [ORNL]

Discourse for slide presentation: An overview of chemical detection systems

A brief overview of some of the analytical techniques currently used in monitoring and analyzing permanent gases and selected volatile organic compound in air are presented. Some of the analytical considerations in developing a specific method are discussed. Four broad groups of hardware are discussed: compound class specific personal monitors, gas chromatographic systems, infrared spectroscopic systems, and mass spectrometric residual gas analyzer systems. Three types of detectors are also discussed: catalytic sensor based systems, photoionization detectors, and wet or dry chemical reagent systems. Under gas chromatograph based systems five detector systems used in combination with a GC are covered: thermal conductivity detectors, photoionization detectors, Fourier transform infrared spectrophotometric systems, quadrapole mass spectrometric systems, and a relatively recent development, a surface acoustic wave vapor detector.

Peters, Randy Alan

Impact-induced devolatilization and hydrogen isotopic fractionation of serpentine: Implications for planetary accretion

Impact-induced devolatilization of porous serpentine was investigated using two independent experimental methods, the gas recovery and the solid recovery method, each yielding nearly identical results. For shock pressures near incipient devolatilization, the hydrogen isotopic composition of the evolved H2O is very close to that of the starting material. For shock pressures at which up to 12 percent impact-induced devolatilization occurs, the bulk evolved gas is significantly lower in deuterium than the starting material. There is also significant reduction of H2O to H2 in gases recovered at these higher shock pressures, probably caused by reaction of evolved H2O with the metal gas recovery fixture. Gaseous H2O-H2 isotopic fractionation suggests high temperature isotopic equilibrium between the gaseous species, indicating initiation of devolatilization at sites of greater than average energy deposition. Bulk gas-residual solid isotopic fractionations indicate nonequilibrium, kinetic control of gas-solid isotopic ratios. Impact-induced hydrogen isotopic fractionation of hydrous silicates during accretion can strongly affect the long-term planetary isotopic ratios of planetary bodies, leaving the interiors enriched in deuterium. Depending on the model used for extrapolation of the isotopic fractionation to devolatilization fractions greater than those investigated experimentally can result from this process.

Tyburczy, James A.

Polycrystalline silicon on tungsten substrates

Thin films of electron-beam-vaporized silicon were deposited on fine-grained tungsten substrates under a pressure of about 1 x 10 to the -10th torr. Mass spectra from a quadrupole residual-gas analyzer were used to determine the partial pressure of 13 residual gases during each processing step. During separate silicon depositions, the atomically clean substrates were maintained at various temperatures between 400 and 780 C, and deposition rates were between 20 and 630 A min. Surface contamination and interdiffusion were monitored by in situ Auger electron spectrometry before and after cleaning, deposition, and annealing. Auger depth profiling, X-ray analysis, and SEM in the topographic and channeling modes were utilized to characterize the samples with respect to silicon-metal interface, interdiffusion, silicide formation, and grain size of silicon. The onset of silicide formation was found to occur at approximately 625 C. Above this temperature tungsten silicides were formed at a rate faster than the silicon deposition. Fine-grain silicon films were obtained at lower temperatures.

Bevolo, A. J.

Efficient solar cells by space processing

Thin films of electron beam evaporated silicon were deposited on molybdenum, tantalum, tungsten and molybdenum disilicide under ultrahigh vacuum conditions. Mass spectra from a quadrapole residual gas analyzer were used to determine the partial pressure of 13 residual gases during each processing step. Surface contamination and interdiffusion were monitored by in situ Auger electron spectrometry. The presence of phosphorus in the silicon was responsible for attaining elevated temperatures with silicide formations. Heteroepitaxial silicon growth was sensitive to the presence of oxygen during deposition, the rate and length of deposition as well as the substrate orientation.

Schmidt, F. A.