Hydraulic Fractures Are Pressure Relief Valves
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Although oxygen is a chemically stable element, it is not shock sensitive, will not decompose, and is not flammable. Oxygen use therefore carries a risk that should never be overlooked, because oxygen is a strong oxidizer that vigorously supports combustion. Safety is of primary concern in oxygen service. To promote safety in oxygen systems, the flammability of materials used in them should be analyzed. At the NASA White Sands Test Facility (WSTF), we have performed configurational tests of components specifically engineered for oxygen service. These tests follow a detailed WSTF oxygen hazards analysis. The stated objective of the tests was to provide performance test data for customer use as part of a qualification plan for a particular component in a particular configuration, and under worst-case conditions. In this document - the 'Guide for Oxygen Component Qualification Tests' - we outline recommended test systems, and cleaning, handling, and test procedures that address worst-case conditions. It should be noted that test results apply specifically to: manual valves, remotely operated valves, check valves, relief valves, filters, regulators, flexible hoses, and intensifiers. Component systems are not covered.
NASA's Space Environment Simulation Laboratory's (SESL) Chamber A, located at the Johnson Space Center in Houston Texas has recently implemented major enhancements of its cryogenic and vacuum systems. The new liquid nitrogen (LN2) thermo-siphon system was successfully commissioned in August of 2012. Chamber A, which has 20 K helium cryo-panels (or shrouds ) which are shielded by 80 K nitrogen shrouds, is capable of simulating a deep space environment necessary to perform ground testing of NASA s James Webb Space Telescope (JWST). Chamber A s previous system used forced flow LN2 cooling with centrifugal pumps, requiring 200,000 liters of LN2 to cool-down and consuming 180,000 liters per day of LN2 in steady operation. The LN2 system did not have the reliability required to meet the long duration test of the JWST, and the cost estimate provided in the initial approach to NASA-JSC by the sub-contractor for refurbishment of the system to meet the reliability goals was prohibitive. At NASA-JSC's request, the JLab Cryogenics Group provided alternative options in 2007, including a thermo-siphon, or natural flow system. This system, eliminated the need for pumps and used one tenth of the original control valves, relief valves, and burst disks. After the thermo-siphon approach was selected, JLab provided technical assistance in the process design, mechanical design, component specification development and commissioning oversight, while the installation and commissioning operations of the system was overseen by the Jacobs Technology/ESC group at JSC. The preliminary commissioning data indicate lower shroud temperatures, 70,000 liters to cool-down and less than 90,000 liters per day consumed in steady operation. All of the performance capabilities have exceeded the design goals. This paper will outline the comparison between the original system and the predicted results of the selected design option, and the commissioning results of thermo-siphon system.
NASA s Space Environment Simulation Laboratory s (SESL) Chamber A, located at the Johnson Space Center in Houston Texas has recently implemented major enhancements of its cryogenic and vacuum systems. The new liquid nitrogen (LN) thermo-siphon system was successfully commissioned in August of 2012. Chamber A, which has 20 K helium cryo-panels (or shrouds ) which are shielded by 80 K nitrogen shrouds, is capable of simulating a deep space environment necessary to perform ground testing of NASA s James Webb Space Telescope (JWST). Chamber A s previous system used forced flow LN cooling with centrifugal pumps, requiring 220,000 liters of LN to cool-down and consuming 180,000 liters per day of LN in steady operation. The LN system did not have the reliability required to meet the long duration test of the JWST, and the cost estimate provided in the initial approach to NASA-JSC by the subcontractor for refurbishment of the system to meet the reliability goals was prohibitive. At NASA-JSC s request, the JLab Cryogenics Group provided alternative options in 2007, including a thermo-siphon, or natural flow system. This system, eliminated the need for pumps and used one tenth of the original control valves, relief valves, and burst disks. After the thermo-siphon approach was selected, JLab provided technical assistance in the process design, mechanical design, component specification development and commissioning oversight, while the installation and commissioning operations of the system was overseen by the Jacobs Technology/ESC group at JSC. The preliminary commissioning data indicate lower shroud temperatures, 68,000 liters to cool-down and less than 91,000 liters per day consumed in steady operation. All of the performance capabilities have exceeded the design goals. This paper will outline the comparison between the original system and the predicted results of the selected design option, and the commissioning results of thermo-siphon system.
In many industrial applications, pressure relief valves (PRV) perform the critical function of safely releasing pressure before potentially damaging build-ups occur. Conventional relief valves, however, have proven unstable, leading to premature wear and devasting consequences. A high-performance pressure relief valve, the PRV95, now being manufactured my Marotta Scientific Controls, Inc., of Montville, NJ, provides the answer to premature wear and instability. Using an improved valve design developed under a NASA Small Business Innovation Research Program (SBIR) contract from John C. Stennis Space Center (SSC), Marotta's PRV95 pressure relief valve provides stability over the entire operational range, from fully closed to fully open. The valve employs upstream control for valve positioning, that makes the valve more stable and affords excellent repeatability with minimal lag time. 'It opens and closes softly, and does not oscillate or generate hard impacts; oscillation can result in a hard impact pressure release, which can lead to an explosion in the presence of oxygen,' says Bill St. Cyr, Chief of Test Technology Branch at Stennis Space Center. Marotta's PRV95 design is also unique in its ability to maintain a seal near the set point of the relief limit. Typically, relief valves seal tightly up to 90% of set point and then reseat when pressure is reduced to 85% of set point. The PRV95 technology maintains seal integrity until 98% of set point and will reseat a 95-97% of set point. This allows the operator to protect his system while not exceeding its limits.
The Barrow Hydrogen Fill System is intended for use by the authorized Sandia National Laboratories personnel and its contractors who are involved in research relating to the deployment of weather balloons for the Department of Energy's Atmospheric Radiation Measurement Program (ARM) https://www.arm.gov/ and The National Weather Service (NWS) https://www.weather.gov/. Hydrogen is supplied from a hydrogen generation shelter and outdoor storage tank. The balloons are filled and released by a remote balloon launcher (RBL) commercially available from Vaisala. The RBL was designed to be used with helium or hydrogen and has be recently inspected by Vaisala for hydrogen operation. This system is composed of a pressure regulator, ball valves, pressure relief valves, tubing, hose. All pressurized components are "off the shelf items and have a minimum pressure rating of 300 psi and are assembled using "Best Practices" and trained pressure component installers. Non pressurized components are comprised of industry recommended components and are assembled using "Best Practices" techniques.
A proposed device would remove bubbles of gas from a stream of liquid (typically water), accumulate the gas, and periodically release the gas, in bulk, back into the stream. The device is intended for use in a flow system (1) in which there is a requirement to supply bubble-free water to a downstream subsystem and (2) that includes a sensor and valves, just upstream of the subsystem, for sensing bubbles and diverting the flow from the subsystem until the water stream is again free of bubbles. By coalescing the gas bubbles and then periodically releasing the accumulated gas, the proposed device would not contribute to net removal of gas from the liquid stream; nevertheless, it would afford an advantage by reducing the frequency with which the diverter valves would have to be activated. The device (see figure) would include an upper and a lower porous membrane made of a hydrophilic material. Both membranes would cover openings in a tube leading to an outlet. These membranes would allow water, but not gas bubbles, to pass through to the interior of the tube. Inside the tube, between the two membranes, there would be a flow restrictor that would play a role described below. Below both membranes there would be a relief valve. Water, possibly containing bubbles, would enter from the top and would pass through either the lower membrane or both membranes, depending how much gas had been accumulated thus far. When the volume of accumulated gas was sufficient to push the top surface of the liquid below the lower porous membrane, water could no longer flow through either membrane toward the outlet. This blockage would cause an increase in back pressure that would cause the relief valve to open. The opening of the relief valve would allow both the water and the bulk-accumulated gas to pass through to the outlet. Once the gas had been pushed out, water would once again flow through both membranes at a much lower pressure drop. The flow restrictor would maintain enough pressure drop to keep the relief valve open until gas had been cleared from both hydrophilic membranes.
Using an improved valve design developed under an SBIR contract with Stennis Space Center, Marotta Scientific's PRV95 provides stability over the entire operational range, from fully closed to fully open. The valve employs a concept known as upstream control for valve positioning, making it more dependable with excellent repeatability and minimal lag time. The PRV95 design is unique in its ability to maintain a seal near the set point of the relief limit. Typically, relief valves seal tightly up to 90 percent set point and then reseat when pressure is reduced to 85 percent of set point. This new technology maintains seal integrity until 98 percent of set point and will reseat at 95 to 97 percent of set point. This allows the operator to protect a system without exceeding its limits.
Loss-of-Coolant Accident (LOCA) in Boiling Water Reactor (BWR) especially on Fukushima Nuclear Accident will be discussed in this paper. The Tohoku earthquake triggered the shutdown of nuclear power reactors at Fukushima Nuclear Power station. Though shutdown process has been completely performed, cooling process, at much smaller level than in normal operation, is needed to remove decay heat from the reactor core until the reactor reach cold-shutdown condition. If LOCA happen at this condition, it will cause the increase of reactor fuel and other core temperatures and can lead to reactor core meltdown and exposure of radioactive material to the environment such as in the Fukushima Dai Ichi nuclear accident case. In this study numerical simulation has been performed to calculate pressure composition, water level and temperature distribution on reactor during this accident. There are two coolant regulating system that operational on reactor unit 1 at this accident, Isolation Condensers (IC) system and Safety Relief Valves (SRV) system. Average mass flow of steam to the IC system in this event is 10 kg/s and could keep reactor core from uncovered about 3,2 hours and fully uncovered in 4,7 hours later. There are two coolant regulating system at operational on reactor unit 2, Reactor Core Isolation Condenser (RCIC) System and Safety Relief Valves (SRV). Average mass flow of coolant that correspond this event is 20 kg/s and could keep reactor core from uncovered about 73 hours and fully uncovered in 75 hours later. There are three coolant regulating system at operational on reactor unit 3, Reactor Core Isolation Condenser (RCIC) system, High Pressure Coolant Injection (HPCI) system and Safety Relief Valves (SRV). Average mass flow of water that correspond this event is 15 kg/s and could keep reactor core from uncovered about 37 hours and fully uncovered in 40 hours later.
Dominant phenomena are identified and characterized for the loss-of-forced-convection (LOFC) scenario, the depressurized loss-of-forced-convection (DLOFC) scenario, and the moisture ingress scenario with relief valves available scenario. These scenarios are considered for the modular high temperature gas-cooled reactor (MHTGR) baseline design—with both a prismatic core and a pebble-bed core. The objectives of this effort, described in the above paragraph, were achieved by following a methodology identified by the U.S. Nuclear Regulatory Commission (NRC) and recommended in their Regulatory Guide 1.203. The methodology employed is described. For the above scenarios, baseline phenomena identification and ranking tables (PIRTs) generated by a NRC-sponsored effort in 2008 for the LOFC and DLOFC scenarios and a baseline PIRT generated by a Department of Energy-sponsored effort in 2011 by their Next Generation Nuclear Plant (NGNP) Moisture Ingress Assessment Committee were used to identify the dominant phenomena and existing levels-of-knowledge. Ten dominant phenomena (with only medium or low levels-of-knowledge) were identified for the LOFC and DLOFC scenarios including: (1) Inlet plenum stratification and plumes, (2) core coolant flow distribution, (3) radiant heat transfer from the top of the core to the upper vessel head, (4) reactor cavity air circulation and heat transfer, (5) reactor cavity cooling system behavior, (6) decay heat distributions, (7) core effective thermal conductivity, (8) molecular diffusion in air ingress DLOFC, (9) duct exchange flow, (10) phenomena that affect cavity gas composition for air-ingress. Five dominant phenomena, with high levels of knowledge, were identified for the moisture-ingress scenario with relief valves available including: (1) flow through break, (2) moisture level in the primary, (3) transport to moisture monitor, (4) moisture monitor instrument response, and (5) heat removal by shutdown cooling system. These phenomena are discussed and characterized. A listing of experiments—both completed and ongoing—is given with a view toward including data useful for further more detailed examination of the dominant phenomena listed in the previous paragraph. Note that only data for the LOFC and DLOFC scenarios are listed—since the moisture ingress scenario with relief valves available –have been identified as having adequate levels-of-knowledge by the PIRT committee. Finally, a preliminary computational fluid dynamics (CFD) calculation of inlet plenum stratification and plumes is described. Techniques employed for this calculation are typical for preliminary scoping calculations performed to validate numeric tools.
Ontario Power Generation Nuclear (OPGN) has a 4 x 880 MWe CANDU nuclear station at its Darlington Nuclear Div. located in Bowmanville. The station operates a Tritium Removal Facility (TRF) to reduce and maintain low tritium levels in the Moderator and Heat Transport heavy water systems of Ontario's CANDU fleet by extracting, concentrating, immobilizing and storing as a metal tritide. Minimizing tritium releases to the environment is of paramount importance to ensure that dose to the public is as low as reasonably achievable (ALARA) and to maintain credibility with the Public. Tritium is removed from the Cryogenic Distillation System to the Tritium Immobilization System (TIS) glove box via a transfer line that is protected by a rupture disc and relief valve. An overpressure event in 2003 had caused the rupture disc to blow, resulting in the release of a significant quantity of elemental tritium into the relief valve discharge line, which ties into the contaminated exhaust system. As a result of a few similar events occurring over a number of years of TRF operation, the released elemental tritium would have been converted to tritium oxide in the presence of a stagnant moist air environment in the stainless steel discharge line. A significant amount of tritium oxide hold-up in the discharge line was anticipated. To minimize any further releases to the environment, a Bubbler System was designed to remove and recover the tritium from the discharge line. This paper summarizes the results of several Bubbler recovery runs that were made over a period of a month. Approximately 3500 Ci of tritium oxide and 230 Ci of elemental tritium were removed and collected. The tritium contained in the water produced from the Bubbler system was later safely recovered in the station's downgraded D{sub 2}O clean-up and recovery system. (authors)
The Department of Energy (DOE) National Energy Technology Laboratory (NETL) and other critical stakeholders (e.g., U.S. Environmental Protection Agency (USEPA), state regulators, and industry) seek to more accurately characterize and quantify methane emissions from compressors and gathering lines within the Gathering and Boosting (G&B) segment of the natural gas system network. These efforts will reduce uncertainties in emissions estimates in USEPA’s current Green House Gas Inventory (GHGI) under their Greenhouse Gas Reporting Program (GHGRP). For this study, four G&B stations in the Gulf Coast Area were visited four times over the course of one year. Components were classified according to equipment and component type and emissions from select components were measured using multiple measurement technologies. The following major equipment types were considered: i) compressors, ii) separators, iii) dehydrators, iv) coalescers, v) slug catchers, vi) yard piping, vii) tanks, and viii) gathering lines. Individual components on each equipment type were further divided into the following main categories: i) connectors, ii) valves, iii) pressure relief valves (PRV), iv) meters, v) gauges, vi) regulators, vii) pneumatic device vents, and viii) compressor vents (e.g., distance piece vents [DPVs] and rod packing vents [RPVs]). Components were screened for the presence of leaks and venting emissions with an optical gas imaging (OGI) camera, and methane emission rates were measured using a microdilution high volume sampler. Downwind emissions were measured using an Open Path Fourier Transform Infrared (OP-FTIR) Spectrometer. Data were evaluated to assess correlation with site, equipment, time, and operational variables. Key findings and recommendations from the study include: A) Different counting methodologies can result in vastly different component counts, thus influencing total emissions calculations using Subpart W population EFs. A standard methodology should be adopted for classifying and counting components in order to minimize inconsistencies across studies and instruct stakeholders responsible for GHGI reporting. B) Results support current component subcategories listed in USEPA Subpart W, including the subdivision of connectors (flanged and “other”) and pneumatic device vents (intermittent, continuous low bleed, and continuous high bleed). C) Emission rates vary across sites and a relationship between higher emissions and compressor age was observed for some components. D) Component emission rates varied between field campaigns. The type of components contributing to overall measured emissions also varied among field campaigns. However, the emission rate variability was larger between different components (of the same category) than the variability in one component over the four field campaigns. Therefore, when calculating emission factors, it is not necessary to take repeat measurements to capture component variability. E) Measuring the emission rate of a sample for an extended period of time is not necessary to capture the average component emission rate. F) For reporting purposes, excluding liquid lines from site-wide screening may have a negligible effect on component-related emissions. However, from a site management perspective, malfunctioning components were not uncommon on liquid lines and contributed substantially to fugitive emissions at some sites. G) Population EFs, whether including or excluding liquid lines, were a conservative estimate of fugitive emissions. Leaker EFs consistently underestimated emissions at the field sites. Measurements at more sites, particularity sites in other areas of the country, need to be completed before determining the accuracy of EFs.
I.Nomenclaturemtypical_mission=internal mass of propellant lost over the course of a mission with Qtypicalmmission_goal=mass of propellant loss over the course of a mission with Qgoaltmission=theoretical mission durationQtypical=internal leakage rate found in commercially available valvesQgoal=internal leakage rate design goalρH2_STP=density of hydrogen at standard temperature and pressure.1NASA AST, Liquid Propulsion Valve Engineer.Valves, Actuators, and Ducts Design and Development Branch (ER14)2NASA AST, Liquid Propulsion Valve Engineer.Valves, Actuators, and Ducts Design and Development Branch (ER14)3NASA AST, Liquid Propulsion Valve Engineer (Retired).Valves, Actuators, and Ducts Design and Development Branch (ER14)4JSEG ESSCA, Engineering Specialist.Valves Actuators and Ducts Design and Development Branch (ER14)5NASA AST, Liquid Propulsion Valve Engineer.Valves, Actuators, and Ducts Design and Development Branch (ER14)6JSEG ESSCA, Valve Design and Development Engineer.Valves Actuators and Ducts Design and Development Branch (ER14) II.IntroductionCurrent aerospace cryogenic valves present challenges to potential long duration missions that utilize cryogenic propellants. Small interplanetary and long-life communication satellites typically utilize hypergolic propellants that operate at higher temperatures, making it easier to achieve very low internal leakage rates. Larger vehicles for long duration missions will likely need to utilize cryogenic-based chemical and nuclear systems to achieve mission requirements. Some early propulsion concepts are projected to require valves with a nominal size ranging from 3” to 10”.Currently available cryogenic aerospace valves typically have internal leakage rates which can range from 100 to 300 SCIM for 3” valves, or upwards of 2,000 SCIM for 10” valves. With just a few of these valves in a system, internal leakage could account for multiple tons of propellant loss over the course of a potential Mars mission, as shown in Figure 1.Figure 1 - Potential Propellant Loss Over the Course of a Long Duration MissionMost internal leakage rates can be attributed to inherent imperfections and misalignments, which result in imperfect contact between sealing surfaces, as shown in Figure 2.Figure 2 - Imperfections and Misalignments Between Sealing Surfaces The ER14 Branch at Marshall Space Flight Center (MSFC) has created a self-aligning seat and poppet design (shown in Figure 3) that allows a valve to be more tolerant of imperfect contacts. This design utilizes a metallic poppet head with five degrees of freedom that allows the poppet toself-align with the seat, reducing the need for tight tolerances.Figure 3 - Self-Aligning Seat and Poppet DesignIII.Test Valve DescriptionA series of development tasks have been conducted to study potential improvements to internal leakage rates. These tasks include 3 test valves (shown in Figure 4) to demonstrate the potential application to various configurations and sizes:A 3” isolation valve for liquid flows (similar to a fill and drain valve)A 3” relief valve for low temperature gas flows.An 8” pre-valve (similar to the engine isolation valve needed on a Nuclear Thermal Propulsion (NTP) engine).Figure 4 - Low Leakage Development Test ValvesThese valves have been developed and are currently being tested at liquid nitrogen (LN2) temperatures, and are anticipated to undergo testing at liquid hydrogen (LH2) temperatures in late 2022
A MELCOR 1.8.5 model of the Peach Bottom Unit 2 or 3 has been updated for MELCOR 1.8.6. Primarily, this update involved modification of the lower head modeling. Three additional updates were also performed. First, a finer nodalization of the containment wet well was employed. Second, the pressure differential used by the logic controlling the safety relief valve actuation was modified. Finally, an additional stochastic failure mechanism for the safety relief valves was added. Simulation results from models with and without the modifications were compared. All the analysis was performed by comparing key figures of merit from simulations of a long-term station blackout scenario. This report describes the model changes and the results of the comparisons.
A system for recovering and recycling gases is disclosed. The system is comprised of inlet and outlet flow lines, controllers, an inflatable enclosure, and inflatable rib stiffeners which are inflatable by the gas to be stored. The system does not present gas at an undesirable back pressure to the gas source. A filtering relief valve is employed which prevents environmental airborne contamination from flowing back into the system when the relief valve is closing. The system is for storing and re-using helium.
The Atmospheric Revitalization Pressure Control Subsystem (ARPCS) provides oxygen partial pressure and total pressure control for the habitable atmosphere of the Shuttle for either a one atmosphere environment or an emergency 8 PSIA mode. It consists of a Supply Panel, Control Panel, Cabin Pressure Relief Valves and Electronic Controllers. The panels control and monitor the oxygen and nitrogen supplies. The cabin pressure relief valves protect the habitable environment from overpressurization. Electronic controllers provide proper mixing of the two gases. This paper describes the ARPCS, addresses the changes in hardware that have occurred since the inception of the program; the performance of this subsystem during STS-1 and STS-2; and discusses future operation modes.
Data sets from simulation runs include 144 wave cases that were run based on the WEC-Sim model (https://mhkdr.openei.org/submissions/483). The 144 wave cases represent waves with the following wave height and wave period ranges: - Significant Wave Height: 0.25 - 4.0m in 0.25m increments - Wave Period: 5 - 13 sec in 1 sec increments Each run was simulated using a Pierson-Moskowitz irregular wave spectrum with a 200 second ramp time and a total simulation time of 2,200 seconds. Summary data set includes a spreadsheet and image files with matrices that are associated with data from simulation runs. All matrices cover the same significant wave height and wave periods from the sim runs, in the same increments. The following matrices are included: - Mechanical Power Input: Absorbed power calculated using linear input velocity at PTO (power take-off) multiplied by winch tension. - Mechanical Power Output: The hydraulic power calculated at the pump output prior to the pressure relief valve dump. - Feed Pressure: Average pressure at RO (reverse osmosis) input prior to pre-filters - RO Power Input: The hydraulic power calculated at the RO system inlet, accounts for flow loss due to pressure relief valve - Water Production: Average clean water flow at RO output
A passive vaporizing heat sink has been developed as a relatively lightweight, compact alternative to related prior heat sinks based, variously, on evaporation of sprayed liquids or on sublimation of solids. This heat sink is designed for short-term dissipation of a large amount of heat and was originally intended for use in regulating the temperature of spacecraft equipment during launch or re-entry. It could also be useful in a terrestrial setting in which there is a requirement for a lightweight, compact means of short-term cooling. This heat sink includes a hermetic package closed with a pressure-relief valve and containing an expendable and rechargeable coolant liquid (e.g., water) and a conductive carbon-fiber wick. The vapor of the liquid escapes when the temperature exceeds the boiling point corresponding to the vapor pressure determined by the setting of the pressure-relief valve. The great advantage of this heat sink over a melting-paraffin or similar phase-change heat sink of equal capacity is that by virtue of the =10x greater latent heat of vaporization, a coolant-liquid volume equal to =1/10 of the paraffin volume can suffice.