Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REFERENCE PRIOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

MRT 7365: Power flow physics and key physics phenomena

The Z accelerator at Sandia National Laboratories conducts z-pinch experiments at 26 MA in support of DOE missions in stockpile stewardship, dynamic materials, fusion, and other basic sciences. Increasing the current delivered to the z-pinch would extend our reach in each of these disciplines. To achieve increases in current and accelerator efficiency, a fraction of Z’s shots are set aside for research into transmission-line power flow. These shots, with supporting simulations and theory, are incorporated into this Advanced Diagnostics milestone report. The efficiency of Z is reduced as some portion of the total current is shunted across the transmission-line gaps prior to the load. This is referred to as “current loss”. Electrode plasmas have long been implicated in this process, so the bulk of dedicated power-flow experiments are designed to measure the plasma environment. The experimental analyses are enhanced by simulations conducted using realistic hardware and Z voltage pulses. In the same way that diagnostics are continually being improved for sensitivity and resolution, the modeling capability is continually being improved to provide faster and more realistic simulations. The specifics of the experimental hardware, diagnostics, simulations, and algorithm developments are provided in this report. The combined analysis of simulation and data confirms that electrode plasmas have the most detrimental impact on current delivery. Experiments over the last three years have tested the theoretical current-loss mechanisms of enhanced ion current, plasma gap closure, and Hall-related current. These mechanisms are not mutually exclusive and may be coincident in the final feed as well as in upstream transmission lines. The final-feed geometries tested here, however, observe lower-density plasmas without dominant ion currents which is consistent with a Hall-related current. The picture of plasma formation and transport formed from experiment and simulation is informing hardware designs being fielded on Z now and being proposed for the Next-Generation Pulsed Power (NGPP) facility. In this picture, the strong magnetic fields that heat the electrodes above particle emission thresholds also confine the charged particles near the surface. Some portion of the plasmas thus formed is transported into the transmission-line gap under the force of the electric field, with aid from plasma instabilities. The gap plasmas are then transported towards the load by a cross-field drift, where they accumulate and contribute to a likely Hall-related cross-gap current. The achievements in experimental execution, model validation, and physical analysis presented in this report set the stage for continued progress in power flow and load diagnostics on Z. The planned shot schedule for Z and Mykonos will provide data for extrapolation to higher current to ensure the predicted performance and efficiency of a NGPP facility.

43 PARTICLE ACCELERATORS↗

Seven Years of Imaging the Global Heliosphere with IBEX

The Interstellar Boundary Explorer ( IBEX ) has now operated in space for 7 years and returned nearly continuous observations that have led to scientific discoveries and reshaped our entire understanding of the outer heliosphere and its interaction with the local interstellar medium. Here we extend prior work, adding the 2014–2015 data for the first time, and examine, validate, initially analyze, and provide a complete 7-year set of Energetic Neutral Atom (ENA) observations from ∼0.1 to 6 keV. The data, maps, and documentation provided here represent the 10th major release of IBEX data and include improvements to various prior corrections to provide the citable reference for the current version of IBEX data. We are now able to study time variations in the outer heliosphere and interstellar interaction over more than half a solar cycle. We find that the Ribbon has evolved differently than the globally distributed flux (GDF), with a leveling off and partial recovery of ENAs from the GDF, owing to solar wind output flattening and recovery. The Ribbon has now also lost its latitudinal ordering, which reflects the breakdown of solar minimum solar wind conditions and exhibits a greater time delay than for the surrounding GDF. Together, the IBEX observations strongly support a secondary ENA source for the Ribbon, and we suggest that this be adopted as the nominal explanation of the Ribbon going forward.

79 ASTRONOMY AND ASTROPHYSICS↗

Ozonesonde Quality Assurance: JOSIE-SHADOZ (2017) and SHALLOTS (2018)

Ozonesonde data constitute a mainstay of satellite calibration and are used for climatologies and analysis of trends, especially in the lower stratosphere where satellites are most uncertain. The electrochemical-concentration cell (ECC) ozonesonde has been deployed at ~100 stations worldwide since the 1960s, with changes over time in manufacture and procedures, including details of the cell chemical solution and data processing. As a consequence, there are biases among different stations and discontinuities in profile timeseries from individual site records. Since 1996 the Jülich [Germany] Ozone Sonde Intercomparison Experiment (JOSIE) has periodically tested ozonesondes in a simulation chamber designated the World Calibration Centre for Ozonesondes by WMO. In October- November 2017 a JOSIE campaign evaluated the sondes and procedures used in SHADOZ (Southern Hemisphere Additional Ozonesondes), a 14-station tropical and subtropical network. A distinctive feature of the 2017 JOSIE was that the tests were conducted by operators from eight SHADOZ stations; Nairobi, Natal, Irene, Costa Rica, Paramaribo, Reunion, Hanoi, Kuala Lumpur. Experimental protocols and preliminary results for the SHADOZ sonde configurations, which represent most of those in use today, are described. SHADOZ stations that follow WMO-recommended protocols record total ozone within 3% of the JOSIE reference instrument. Instrument biases noted in prior JOSIE and field tests like BESOS (2004) were noted in JOSIE-2017, with maximum effect in the stratosphere. In June 2018 we organized a series of dual launches during the OWLETS II campaign in the Maryland and Chesapeake Bay area (SHALLOTS = SHADOZ-OWLETS ParaLLel Ozonesonde Test Study). Instrument and solution types were varied as in JOSIE-2017 and three radiosonde-ozonesonde variants were tested. An example of a parallel sampling in SHALLOTS, from a Greenbelt EnSCI-iMet sonde combination flown with the Wallops SPCLMS package, is illustrated in the Figure. The result was a range of biases but in general the instrument combination (EnSCI-iMet) deployed at 11 SHADOZ stations recorded ~5-10% less ozone in the stratosphere than the SPC ECC sonde flown with a Vaisala or LMS system. These 2017 and 2018 results and prior JOSIEs demonstrate that regular testing is essential to maintain best practices in ozonesonde operations and to ensure high-quality data for the ozone assessment communities.

Quality assurance↗

Joint model of motion and anatomy for PET image reconstruction

Anatomy-based positron emission tomography (PET) image enhancement techniques have been shown to have the potential for improving PET image quality. However, these techniques assume an accurate alignment between the anatomical and the functional images, which is not always valid when imaging the chest due to respiratory motion. In this article, we present a joint model of both motion and anatomical information by integrating a motion-incorporated PET imaging system model with an anatomy-based maximum a posteriori image reconstruction algorithm. The mismatched anatomical information due to motion can thus be effectively utilized through this joint model. A computer simulation and a phantom study were conducted to assess the efficacy of the joint model, whereby motion and anatomical information were either modeled separately or combined. The reconstructed images in each case were compared to corresponding reference images obtained using a quadratic image prior based maximum a posteriori reconstruction algorithm for quantitative accuracy. Results of these studies indicated that while modeling anatomical information or motion alone improved the PET image quantitation accuracy, a larger improvement in accuracy was achieved when using the joint model. In the computer simulation study and using similar image noise levels, the improvement in quantitation accuracy compared to the reference images was 5.3% and 19.8% when using anatomical or motion information alone, respectively, and 35.5% when using the joint model. In the phantom study, these results were 5.6%, 5.8%, and 19.8%, respectively. These results suggest that motion compensation is important in order to effectively utilize anatomical information in chest imaging using PET. The joint motion-anatomy model presented in this paper provides a promising solution to this problem.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comment on “STM study of the (111) and (100) surfaces of PdAg, Surf. Sci. 417 (1998) 292–300" and references therein

Investigation of isolated, single atoms on the surfaces of alloys is of great interest in the field of heterogeneous catalysis. Prior studies by Nieuwenhuys, etal. [Surf. Sci. 417 (1998) 292–300 and references therein] showed that annealing the (111) surface of a PdAg bulk alloy yielded a surface with ~5% Pd, predominantly in the form of single atoms, rendering it an ideal model for investigating the reactivity of single Pd atoms. Herein, new evidence is reported that establishes the bulk composition of the PdAg(111) alloy studied previously is 67 % Ag and 33 % Pd, whereas it was reported to be 33 % Ag and 67 % Pd in the prior studies. Furthermore, the bulk composition of a crystal derived from the same PdAg alloy boule used previously was determined using energy-dispersive X-ray spectroscopy (EDS)—a bulk sensitive technique. Surface-sensitive measurements, including X-ray photoelectron spectroscopy, were also performed and are in good agreement with the prior studies by Nieuwenhuys, etal.

36 MATERIALS SCIENCE↗

HostSub_GP: Precise Galaxy Background Subtraction in Transient Long-slit Spectroscopy with Gaussian Processes

We present a novel host galaxy subtraction technique in long-slit spectroscopy for extragalactic transients. Unlike classic methods which generally estimate the background using simple interpolation of local galaxy flux in the 2D spectrum, our approach leverages multi-band archival images of the host galaxies to model the background emission from the galaxy in the 2D spectrum. Such imaging encodes the wavelength-dependent galaxy profile along the slit, and is readily accessible through wide-field imaging surveys. We construct a smooth prior for the 2D galaxy profile with a Gaussian process (GP) based on these reference images, and use another GP to model the correlated deviations from the prior in the observed spectrum. This enables accurate inference of the galaxy flux blended with the transient. On synthetic long-slit data of a spiral galaxy extracted from a Multi Unit Spectroscopic Explorer hyper-spectral cube, the GP method remains robust as long as the host galaxy is spatially resolved and consistently outperforms classic methods. We apply the method to archival Keck spectra of two real transients, SN 2019eix and AT 2019qiz, to further demonstrate how the method uniquely recovers weak spectral features amid strong galaxy contamination, enabling refined constraints on the properties of both transients. We have released the software implementation, HostSub_GP, a scalable toolkit that leverages JAX, with an MIT license.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of normalized metal artifact reduction (NMAR) in kVCT using MVCT prior images for radiotherapy treatment planning

Purpose: To evaluate the metal artifacts in kilovoltage computed tomography (kVCT) images that are corrected using a normalized metal artifact reduction (NMAR) method with megavoltage CT (MVCT) prior images.Methods: Tissue characterization phantoms containing bilateral steel inserts are used in all experiments. Two MVCT images, one without any metal artifact corrections and the other corrected using a modified iterative maximum likelihood polychromatic algorithm for CT (IMPACT) are translated to pseudo-kVCT images. These are then used as prior images without tissue classification in an NMAR technique for correcting the experimental kVCT image. The IMPACT method in MVCT included an additional model for the pair/triplet production process and the energy dependent response of the MVCT detectors. An experimental kVCT image, without the metal inserts and reconstructed using the filtered back projection (FBP) method, is artificially patched with the known steel inserts to get a reference image. The regular NMAR image containing the steel inserts that uses tissue classified kVCT prior and the NMAR images reconstructed using MVCT priors are compared with the reference image for metal artifact reduction. The Eclipse treatment planning system is used to calculate radiotherapy dose distributions on the corrected images and on the reference image using the Anisotropic Analytical Algorithm with 6 MV parallel opposed 5 × 10 cm{sup 2} fields passing through the bilateral steel inserts, and the results are compared. Gafchromic film is used to measure the actual dose delivered in a plane perpendicular to the beams at the isocenter.Results: The streaking and shading in the NMAR image using tissue classifications are significantly reduced. However, the structures, including metal, are deformed. Some uniform regions appear to have eroded from one side. There is a large variation of attenuation values inside the metal inserts. Similar results are seen in commercially corrected image. Use of MVCT prior images without tissue classification in NMAR significantly reduces these problems. The radiation dose calculated on the reference image is close to the dose measured using the film. Compared to the reference image, the calculated dose difference in the conventional NMAR image, the corrected images using uncorrected MVCT image, and IMPACT corrected MVCT image as priors is ∼15.5%, ∼5%, and ∼2.7%, respectively, at the isocenter.Conclusions: The deformation and erosion of the structures present in regular NMAR corrected images can be largely reduced by using MVCT priors without tissue segmentation. The attenuation value of metal being incorrect, large dose differences relative to the true value can result when using the conventional NMAR image. This difference can be significantly reduced if MVCT images are used as priors. Reduced tissue deformation, better tissue visualization, and correct information about the electron density of the tissues and metals in the artifact corrected images could help delineate the structures better, as well as calculate radiation dose more correctly, thus enhancing the quality of the radiotherapy treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A fast, accurate, and automatic 2D-3D image registration for image-guided cranial radiosurgery

The authors developed a fast and accurate two-dimensional (2D)-three-dimensional (3D) image registration method to perform precise initial patient setup and frequent detection and correction for patient movement during image-guided cranial radiosurgery treatment. In this method, an approximate geometric relationship is first established to decompose a 3D rigid transformation in the 3D patient coordinate into in-plane transformations and out-of-plane rotations in two orthogonal 2D projections. Digitally reconstructed radiographs are generated offline from a preoperative computed tomography volume prior to treatment and used as the reference for patient position. A multiphase framework is designed to register the digitally reconstructed radiographs with the x-ray images periodically acquired during patient setup and treatment. The registration in each projection is performed independently; the results in the two projections are then combined and converted to a 3D rigid transformation by 2D-3D geometric backprojection. The in-plane transformation and the out-of-plane rotation are estimated using different search methods, including multiresolution matching, steepest descent minimization, and one-dimensional search. Two similarity measures, optimized pattern intensity and sum of squared difference, are applied at different registration phases to optimize accuracy and computation speed. Various experiments on an anthropomorphic head-and-neck phantom showed that, using fiducial registration as a gold standard, the registration errors were 0.33{+-}0.16 mm (s.d.) in overall translation and 0.29 deg. {+-}0.11 deg. (s.d.) in overall rotation. The total targeting errors were 0.34{+-}0.16 mm (s.d.), 0.40{+-}0.2 mm (s.d.), and 0.51{+-}0.26 mm (s.d.) for the targets at the distances of 2, 6, and 10 cm from the rotation center, respectively. The computation time was less than 3 s on a computer with an Intel Pentium 3.0 GHz dual processor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evolution of the electrothermal instability from thick rod z pinches subject to dynamically and statically applied axial magnetic field

LDRD Project 229427 aimed to determine how electrothermal instability (ETI) driven heating on a z-pinch rod pulsed with intense current evolves under mixed magnetic field (azimuthal + axial) conditions, which is pertinent to pulsed-power-driven magnetically-insulated transmission lines and physics targets. Experiments focused on diagnosing ETI-driven heating from deliberately-machined and well-characterized micron-scale surface defects (referred to as engineered defects or ED). Prior to the start of this project, understanding of how unmagnetized (B z =0) ED evolve had been obtained—simulations largely reproduce the experimentally observed high temperature spots which develop at the poles of bare/uncoated ED. Project 229427 extended the Mykonos Facility ED experimental platform to include axial field. In the first class of experiments, axial field was provided “dynamically” via a helical return can (HRC). In this case, B z and B θ rise at the same rate. Generally, the HRC generated magnetic field at a fixed polarization angle Φ B =arctan(B z /B θ )=15° on the rod's surface. In the second class of experiments, axial field was provided “statically” via a slow-rising (millisecond) external Helmholtz coil pair. In this case, B z was effectively constant/static throughout the 100 ns rise of the Mykonos current. For either case, a primary goal was to determine whether ETI provides a helical seed perturbation for the subsequent growth of the helical magneto Rayleigh-Taylor modes observed in MagLIF (static B z ) and dynamic screw pinch (DSP, dynamic B z ) experiments. When dynamic field was applied using an HRC, emissions from individual ED aligned toward Φ B , while emissions from ED within pairs elongated and preferentially merged along Φ B . These data strongly support that for a randomized defect distribution, heating from nearby current-density perturbations will favorably merge about Φ B to generate an extended seed perturbation that aligns toward the surface-field polarization, and this may impact the orientation of subsequent MRT growth on imploding liners. The results from the static field experiments were largely inconclusive, as any ETI heating rotation, if present, was obscured/overwhelmed by local/random heating from ED rim imperfections.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-Sensor Optimal Motion Planning for Radiological Contamination Surveys by Using Prediction-Difference Maps

Distributed and networked mobile sensor platforms using unmanned aerial and/or ground vehicles to survey areas of interest offer a safer and more efficient method for radiological contamination mapping; however, most applications rely on uniformly sweeping of the area in a raster-type motion without utilizing the information available in a dynamic sense. We have developed a fully autonomous optimal motion planning procedure for networks with two or more mobile sensors. The procedure utilizes well-established concepts of Gaussian processes in combination with control laws based on centroidal Voronoi tessellations to achieve optimal next-iteration sensor movements. A new method of informing optimal motion planning is proposed, whereby the absolute difference between the prior and current full-map prediction, referred to as the prediction-difference map, is used as the spatial density function within each Voronoi cell, providing immediate and iterative feedback for dynamic use of available information. The Gaussian process regression model used to estimate the contamination in unvisited locations also provides prediction uncertainties, and can be used as a quantitative metric to assess the confidence in the calculated contamination map; these estimates and prediction uncertainties are unavailable for standard uniform survey routines as they can only produce maps in the vicinity of observed locations. We present through simulation the achievable performance gains from using this new method by directly comparing to a uniform survey method. Results show that using the prediction-difference maps to inform motion planning procedures offers a faster rate of producing an accurate and convergent map relative to a uniform survey route.

47 OTHER INSTRUMENTATION↗

Method For Model-Reference Adaptive Control

Relatively simple method of model-reference adaptive control (MRAC) developed from two prior classes of MRAC techniques: signal-synthesis method and parameter-adaption method. Incorporated into unified theory, which yields more general adaptation scheme.

Seraji, Homayoun↗

The early Earth Observing System reference handbook: Earth Science and Applications Division missions, 1990-1997

Prior to the launch of the Earth Observing System (EOS) series, NASA will launch and operate a wide variety of new earth science satellites and instruments, as well as undertake several efforts collecting and using the data from existing and planned satellites from other agencies and nations. These initiatives will augment the knowledge base gained from ongoing Earth Science and Applications Division (ESAD) programs. This volume describes three sets of ESAD activities -- ongoing exploitation of operational satellite data, research missions with upcoming launches between now and the first launch of EOS, and candidate earth probes.

Source record↗

Viability of Small Dimension Crew Quarters for Surface Habitation

During early planning for the Artemis program’s sustained phase of lunar activity, NASA planners have been held to work towards a NASA reference lunar lander concept. With this activity taking place prior to the awarding of a lander contract, NASA planners cannot assume which of several potential landers will be available. This has limited habitation team engineers to a 12-metric ton mass limit for the reference concept of the lunar Surface Habitat. Consequently, minimal approaches have been applied to many habitat systems and it is important to determine acceptable volume for crew quarters. A number of both NASA and non-NASA surface habitat concepts have proposed relatively small crew quarters due to this constraint. Consequently, there is a need to collect objective test data to confirm or refute the validity of small crew quarters. NASA-STD-3001 is looked to for guidance in its many standards but offers little to no help. While prior versions called for private habitation, the current version – Revision B – calls for “individual privacy” to “accommodate social retreat.” Proposed Revision C modifications change the language slightly to “accommodate sleep and social retreat.” This is not enough guidance to determine the size of a crew quarters or even its capabilities. Unfortunately, only a small number of US spacecraft have included crew quarters, primarily the International Space Station and the Skylab Space Station. The space shuttle orbiter sometimes flew a set of private bunks that some might consider a crew quarters. All of these are dramatically smaller than US standards for minimum jail cells. The first opportunity for NASA to test a small crew quarters in a surface habitat application has been created through the Exploration Atmospheres test series, which is evaluating human performance under reduced cabin pressures. The test is converting the 20-Foot Vacuum Chamber at Johnson Space Center into a habitat, with the lower level outfitted as an EVA test area and the upper two levels for human habitation. The test will place eight people (six test subjects and two technicians) inside the chamber for eleven days. All eight will sleep in private quarters during the test. Volume limitations in the chamber forced extremely small crew quarters, measuring approximately 2 meters in length, 0.85 meters in height, and 0.9 meters in width. The test cabin pressure of 8.2 psi and elevated oxygen also introduces significant material limitations, limiting outfitting options. Nonetheless, the crew quarters design requirements were to accommodate visual separation, auditory separation, olfactory separation, tactile separation, air flow control, lighting control, single person personal computing, physical work surface access, sleep accommodations, non-sleep rest/relaxation, meditation, stretching, two-person meetings, snacking, changing clothes, viewing appearance, video communication, and audio communication. This paper will detail the acceptability of the crew quarters as measured in the October 2021 Exploration Atmosphere test. Based on this data, the viability of the type of crew quarters used in the 20 Foot Chamber will be assessed. Design recommendations for a 30-60-day Surface Habitat crew quarters will be provided, along with recommendations for future testing.

Crew Quarters↗

Patient geometry-driven information retrieval for IMRT treatment plan quality control

Purpose: Intensity modulated radiation therapy (IMRT) treatment plan quality depends on the planner's level of experience and the amount of time the planner invests in developing the plan. Planners often unwittingly accept plans when further sparing of the organs at risk (OARs) is possible. The authors propose a method of IMRT treatment plan quality control that helps planners to evaluate the doses of the OARs upon completion of a new plan. Methods: It is achieved by comparing the geometric configurations of the OARs and targets of a new patient with those of prior patients, whose plans are maintained in a database. They introduce the concept of a shape relationship descriptor and, specifically, the overlap volume histogram (OVH) to describe the spatial configuration of an OAR with respect to a target. The OVH provides a way to infer the likely DVHs of the OARs by comparing the relative spatial configurations between patients. A database of prior patients is built to serve as an external reference. At the conclusion of a new plan, planners search through the database and identify related patients by comparing the OAR-target geometric relationships of the new patient with those of prior patients. The treatment plans of these related patients are retrieved from the database and guide planners in determining whether lower doses delivered to the OARs in the new plan are feasible. Results: Preliminary evaluation is promising. In this evaluation, they applied the analysis to the parotid DVHs of 32 prior head-and-neck patients, whose plans are maintained in a database. Each parotid was queried against the other 63 parotids to determine whether a lower dose was possible. The 17 parotids that promised the greatest reduction in D{sub 50} (DVH dose at 50% volume) were flagged. These 17 parotids came from 13 patients. The method also indicated that the doses of the other nine parotids of the 13 patients could not be reduced, so they were included in the replanning process as controls. Replanning with an effort to reduce D{sub 50} was conducted on these 26 parotids. After replanning, the average reductions for D{sub 50} of the 17 flagged parotids and nine unflagged parotids were 6.6 and 1.9 Gy, respectively. These results demonstrate that the quality control method has accurately identified not only the parotids that require dose reductions but also those for which dose reductions are marginal. Originally, 11 of out the 17 flagged parotids did not meet the Radiation Therapy Oncology Group sparing goal of V(30 Gy)<50%. Replanning reduced them to three. Additionally, PTV coverage and OAR sparing of the original plans were compared to those of the replans by using pairwise Wilcoxon p test. The statistical comparisons show that replanning compromised neither PTV coverage nor OAR sparing. Conclusions: This method provides an effective quality control mechanism for evaluating the DVHs of the OARs. Adoption of such a method will advance the quality of current IMRT planning, providing better treatment plan consistency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A radio optical reference frame. II - Additional radio and optical source positions in the Northern Hemisphere

VLBI observations from 12 sessions have been made of a total of 103 sources north of -2 deg declination. These data give the first extension to the radio/optical reference frame catalog already defined by the data in the NASA Crustal Dynamics Project database prior to July 1988. The new observations add 53 new sources to the radio reference frame catalog, improve the positions of 29 from the previous version, and show another seven sources to be unsuitable reference frame objects. Observations of 14 calibration sources tie the new positions to the existing catalog. The formal mean errors for the radio positions of the additional sources are about 0.8 mas in each coordinate. Optical positions for eight sources have been measured in the FK5 system, bringing the total number of sources in the catalog with accurate positions for their optical counterparts to 36. The new optical positions have an accuracy of about 50 mas.

Russell, J. L.↗

Estimating Transmitted-Signal Phase Variations for Uplink Array Antennas

A method of estimating phase drifts of microwave signals distributed to, and transmitted by, antennas in an array involves the use of the signals themselves as phase references. The method was conceived as part of the solution of the problem of maintaining precise phase calibration required for proper operation of an array of Deep Space Network (DSN) antennas on Earth used for communicating with distant spacecraft at frequencies between 7 and 8 GHz. The method could also be applied to purely terrestrial phased-array radar and other radio antenna array systems. In the DSN application, the electrical lengths (effective signal-propagation path lengths) of the various branches of the system for distributing the transmitted signals to the antennas are not precisely known, and they vary with time. The variations are attributable mostly to thermal expansion and contraction of fiber-optic and electrical signal cables and to a variety of causes associated with aging of signal-handling components. The variations are large enough to introduce large phase drifts at the signal frequency. It is necessary to measure and correct for these phase drifts in order to maintain phase calibration of the antennas. A prior method of measuring phase drifts involves the use of reference-frequency signals separate from the transmitted signals. A major impediment to accurate measurement of phase drifts over time by the prior method is the fact that although DSN reference-frequency sources separate from the transmitting signal sources are stable and accurate enough for most DSN purposes, they are not stable enough for use in maintaining phase calibrations, as required, to within a few degrees over times as long as days or possibly even weeks. By eliminating reliance on the reference-frequency subsystem, the present method overcomes this impediment. In a DSN array to which the present method applies (see figure), the microwave signals to be transmitted are generated by exciters in a signal-processing center, then distributed to the antennas via optical fibers. At each antenna, the signals are used to drive a microwave power-amplifier train, the output of which is coupled to the antenna for transmission. A small fraction of the power-amplifier-train output is sent back to the signal-processing center along another optical fiber that is part of the same fiber-optic cable used to distribute the transmitted signal to the antenna. In the signal-processing center, the signal thus returned from each antenna is detected and its phase is compared with the phase of the signal sampled directly from the corresponding exciter. It is known, from other measurements, that the signal-propagation path length from the power-amplifier-train output port to the phase center of each antenna is sufficiently stable and, hence, that sampling the signal at the power-amplifier-train output port suffices for the purpose of characterizing the phase drift of the transmitted signal at the phase center of the antenna

Paal, Leslie↗

Estimating crustal deformations from a combination of baseline measurements and geophysical models

Three possible estimation algorithms are presented for the monitoring of crustal deformations from a combination of repeated baseline measurements and prior deformation information. Attention is given to best linear minimum bias estimation, best linear estimation, and Bayesian estimation. The application of the deformation estimators to the maintenance of a conventional terrestrial reference system is considered. It is shown that if no prior deformation model is available, the free adjustment is the preferred algorithm. In the presence of prior information, however, it is better to use a somewhat incorrect model than to ignore it altogether. The best estimation model of the ones tested is the best linear estimation.

Bock, Y.↗

Defect suppression in wet-treated etched-and-regrown nonpolar m-plane GaN vertical Schottky diodes: A deep-level optical spectroscopy analysis

In this work, steady-state photocapacitance (SSPC) was conducted on nonpolar m-plane GaN n-type Schottky diodes to evaluate the defects induced by inductively coupled plasma (ICP) dry etching in etched-and-regrown unipolar structures. An ~10× increase in the near-midgap Ec – 1.9 eV level compared to an as-grown material was observed. Defect levels associated with regrowth without an etch were also investigated. The defects in the regrown structure (without an etch) are highly spatially localized to the regrowth interface. Subsequently, by depth profiling an etched-and-regrown sample, we show that the intensities of the defect-related SSPC features associated with dry etching depend strongly on the depth away from the regrowth interface, which is also reported previously. A photoelectrochemical etching (PEC) method and a wet AZ400K treatment are also introduced to reduce the etch-induced deep levels. A significant reduction in the density of deep levels is observed in the sample that was treated with PEC etching after dry etching and prior to regrowth. An ~2× reduction in the density of Ec – 1.9 eV level compared to a reference etched-and-regrown structure was observed upon the application of PEC etching treatment prior to the regrowth. The PEC etching method is promising for reducing defects in selective-area doping for vertical power switching structures with complex geometries.

36 MATERIALS SCIENCE↗