Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RECTUM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

TU-AB-201-05: Automatic Adaptive Per-Operative Re-Planning for HDR Prostate Brachytherapy - a Simulation Study On Errors in Needle Positioning

Purpose: To develop adaptive planning with feedback for MRI-guided focal HDR prostate brachytherapy with a single divergent needle robotic implant device. After each needle insertion, the dwell positions for that needle are calculated and the positioning of remaining needles and dosimetry are both updated based on MR imaging. Methods: Errors in needle positioning may occur due to inaccurate needle insertion (caused by e.g. the needle’s bending) and unpredictable changes in patient anatomy. Consequently, the dose plan quality might dramatically decrease compared to the preplan. In this study, a procedure was developed to re-optimize, after each needle insertion, the remaining needle angulations, source positions and dwell times in order to obtain an optimal coverage (D95% PTV>19 Gy) without exceeding the constraints of the organs at risk (OAR) (D10% urethra<21 Gy, D1cc bladder<12 Gy and D1cc rectum<12 Gy). Complete HDR procedures with 6 needle insertions were simulated for a patient MR-image set with PTV, prostate, urethra, bladder and rectum delineated. Random angulation errors, modeled by a Gaussian distribution (standard deviation of 3 mm at the needle’s tip), were generated for each needle insertion. We compared the final dose parameters for the situations (I) without re-optimization and (II) with the automatic feedback. Results: The computation time of replanning was below 100 seconds on a current desk computer. For the patient tested, a clinically acceptable dose plan was achieved while applying the automatic feedback (median(range) in Gy, D95% PTV: 19.9(19.3–20.3), D10% urethra: 13.4(11.9–18.0), D1cc rectum: 11.0(10.7–11.6), D1cc bladder: 4.9(3.6–6.8)). This was not the case without re-optimization (median(range) in Gy, D95% PTV: 19.4(14.9–21.3), D10% urethra: 12.6(11.0–15.7), D1cc rectum: 10.9(8.9–14.1), D1cc bladder: 4.8(4.4–5.2)). Conclusion: An automatic guidance strategy for HDR prostate brachytherapy was developed to compensate errors in needle positioning and improve the dose distribution. Without re-optimization, target coverage and OAR constraints may not be achieved. M. Borot de Battisti is funded by Philips Medical Systems Nederland B.V.; M. Moerland is principal investigator on a contract funded by Philips Medical Systems Nederland B.V.; G. Hautvast and D. Binnekamp are full-time employees of Philips Medical Systems Nederland B.V.

60 APPLIED LIFE SCIENCES↗

SU-F-J-27: Segmentation of Prostate CBCT Images with Implanted Calypso Transponders Using Double Haar Wavelet Transform

Purpose: Segmentation of prostate CBCT images is an essential step towards real-time adaptive radiotherapy. It is challenging For Calypso patients, as more artifacts are generated by the beacon transponders. We herein propose a novel wavelet-based segmentation algorithm for rectum, bladder, and prostate of CBCT images with implanted Calypso transponders. Methods: Five hypofractionated prostate patients with daily CBCT were studied. Each patient had 3 Calypso transponder beacons implanted, and the patients were setup and treated with Calypso tracking system. Two sets of CBCT images from each patient were studied. The structures (i.e. rectum, bladder, and prostate) were contoured by a trained expert, and these served as ground truth. For a given CBCT, the moving window-based Double Haar transformation is applied first to obtain the wavelet coefficients. Based on a user defined point in the object of interest, a cluster algorithm based adaptive thresholding is applied to the low frequency components of the wavelet coefficients, and a Lee filter theory based adaptive thresholding is applied to the high frequency components. For the next step, the wavelet reconstruction is applied to the thresholded wavelet coefficients. A binary/segmented image of the object of interest is therefore obtained. DICE, sensitivity, inclusiveness and ΔV were used to evaluate the segmentation result. Results: Considering all patients, the bladder has the DICE, sensitivity, inclusiveness, and ΔV ranges of [0.81–0.95], [0.76–0.99], [0.83–0.94], [0.02–0.21]. For prostate, the ranges are [0.77–0.93], [0.84–0.97], [0.68–0.92], [0.1–0.46]. For rectum, the ranges are [0.72–0.93], [0.57–0.99], [0.73–0.98], [0.03–0.42]. Conclusion: The proposed algorithm appeared effective segmenting prostate CBCT images with the present of the Calypso artifacts. However, it is not robust in two scenarios: 1) rectum with significant amount of gas; 2) prostate with very low contrast. Model based algorithm might improve the segmentation in these two scenarios.

60 APPLIED LIFE SCIENCES↗

SU-F-T-26: A Study of the Consistency of Brachytherapy Treatments for Vaginal Cuff

Purpose: To evaluate to treatment consistency over the total number of fractions when treatment what HDR brachytherapy using the ML cylinders. At the same time the dosimetric impact on the critical organs is monitored over the total number of fractions. Methods: A retrospective analysis of 10 patients treated with Cylinder applicators, from 2015–2016 were considered for this study. The CT scans of these patients, taken before each treatment were separately imported in to the treatment planning system and paired with the initial CT scan after completing the contouring. Two sets of CT images were fused together with respective to the applicator, using landmark registration. The doses of each plan were imported as well and a cumulative dosimetric analysis was made for bladder, bowels, and rectum and PTV. Results: No contour of any of the OAR was exactly similar when CT images were fused on each other. The PTV volumes vary from fraction to fraction. There was always a difference between the doses received by the OARs between treatments. The maximum dose varied between 5% and 30% in rectum and bladder. The minimum dose varied between 5% and 8% in rectum and bladder. The average dose varied between 15% and 20% in rectum and bladder. Deviation in placement were noticed between fractions. Conclusion: The variation in volumes of OARs and isodoses near the OARs, indicate that the estimated doses to OARs on the planning system may not be the same dose delivered to the patient in all the fractions. There are no major differences between the prescribed dose and the delivered dose over the total number of fractions. In some cases the critical organs will benefit if the consecutive plans will made after the CT scans will be registered with the initial scan and then planned.

60 APPLIED LIFE SCIENCES↗

SU-F-T-31: Shape and Isodose Distributions in Co60 HDR Brachytherapy for Different Utero-Vaginal Time Ratios

Purpose: To optimize the dose in bladder and rectum and show the different shapes of the isodose volumes in Co60-HDR brachytherapy, considering different utero and vaginal sources dwell ratio times (TU:TV). Methods: Besides Ir192-HDR, new Co60-HDR sources are being incorporated. We considered different TU:TV times and computed the dosis in bladder, rectum and at the reference points of the Manchester system. Also, we calculated the isodose volume and shape in each case. We used a EZAG-BEBIG Co0.A86 model with TPS HDRplus3.0.4. and LCT42-7, LCT42-2(R,L) applicators. A reference dose RA= 1.00 Gy was given to the A-right point. We considered the TU:TV dwell time ratios 1:0.25, 1:0.33, 1:0.5, 1:1, 1:2, 1:3, and 1:4. Given TU:TV, the stop time at each dwell position is fixed for each applicator. Results: Increasing TU:TV systematically results in a decreasing of the dose in bladder and rectum, e.g. 9% and 27% reduction were found in 1:0.25 with respect to 1:1, while 12% and 34% increase were found in 1:4 with respect to 1:1. Also, the isodose volume parameters height (h), width (w), thickness (t) and volume (hwt) increased from the 1:0.25 case to the 1:4 value: hwt is 25% lower and 31% higher than the 1:1 reference volume in these cases. Also w decreased for higher TU:TV and may compromise the tumoral volume coverage, decreasing 17% in the 1:0.25 case compared to the 1:1 case. The shape of the isodose volume was obtained for the different TU:TV considered. Conclusion: We obtained the shape of isodose volumes for different TU:TV values in gynecological Co60-HDR. We studied the dose reduction in bladder and rectum for different TU:TV ratios. The volume parameters and hwt are strongly dependent on this ratio. This information is useful for a quantitative check of the TPS and as a starting point towards optimization.

60 APPLIED LIFE SCIENCES↗

SU-F-T-36: Dosimetric Comparison of Point Based Vs. Target Based Prescription for Intracavitary Brachytherapy in Cancer of the Cervix

Purpose: Improved patient imaging used for planning the treatment of cervical cancer with Tandem and Ovoid (T&O) Intracavitary high-dose-rate brachytherapy (HDR) now allows for 3D delineation of target volumes and organs-at-risk. However, historical data relies on the conventional point A-based planning technique. A comparative dosimetric study was performed by generating both target-based (TBP) and point-based (PBP) plans for ten clinical patients. Methods: Treatment plans created using Elekta Oncentra v. 4.3 for ten consecutive cervical cancer patients were analyzed. All patients were treated with HDR using the Utrecht T&O applicator. Both CT and MRI imaging modalities were utilized to delineate clinical target volume (CTV) and organs-at-risk (rectum, sigmoid, bladder, and small bowel). Point A (left and right), vaginal mucosa, and ICRU rectum and bladder points were defined on CT. Two plans were generated for each patient using two prescription methods (PBP and TBP). 7Gy was prescribed to each point A for each PBP plan and to the target D90% for each TBP plan. Target V90%, V100%, and V200% were evaluated. In addition, D0.1cc and D2cc were analyzed for each organ-at-risk. Differences were assessed for statistical significance (p<0.05) by use of Student’s t-test. Results: Target coverage was comparable for both planning methods, with each method providing adequate target coverage. TBP showed lower absolute dose to the target volume than PBP (D90% = 7.0Gy vs. 7.4Gy, p=0.028), (V200% = 10.9cc vs. 12.8cc, p=0.014), (ALeft = 6.4Gy vs. 7Gy, p=0.009), and (ARight = 6.4Gy vs. 7Gy, p=0.013). TBP also showed a statistically significant reduction in bladder, rectum, small bowel, and sigmoid doses compared to PBP. There was no statistically significant difference in vaginal mucosa or ICRU-defined rectum and bladder dose. Conclusion: Target based prescription resulted in substantially lower dose to delineated organs-at-risk compared to point based prescription, while maintaining similar target coverage.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP2-10: Feasibility of Newly Designed Applicator for High Dose Rate Brachytherapy Treatment of Patients with Vaginal Vault Recurrence

Purpose: To compare the dose of an in-house 3D-printed gynecology applicator (TMHGA) for vaginal vault recurrence of corpus cancer patients after operation for high dose rate brachytherapy treatment with commercially available applicators. Methods: A newly designed applicator is made from 3D-printing methods using ABSM30i. The isodose of the applicator is compared with Elekta multi-channel (MC) applicator and titanium Rotterdam applicator with coupling central tube and vaginal cylinder (RC). Three plans are created using three applicators in a CT set of water phantom. The applicators are anchored using the applicator library and implant library in the Elekta Oncentra treatment planning system (ver.4.5). The rectum is mimicked by creating a 2cm diameter cylinder, with a distance 1mm posteriorly away from the high risk CTV (HR-CTV). Similarly, the bladder is replicated by a 6cm diameter cylinder with distance 1mm anteriorly from the HR-CTV. Three plans are all normalized 1.5cm superior, 0.5cm anterior and 0.5cm posterior of the applicator surface. By fixing D90 of HR-CTV to 6Gy, the D2cc of rectum and bladder of three plans are compared. Results: The D2cc of the bladder for using TMHGA is lower than MC and RC by 14.0% and 11.9% respectively. While the D2cc of the rectum for using TMHGA is lower than MC and RC by 18.9% and 12.4% respectively. The total treatment time of TMHGA plan is shorter than MC and RC by 11.2% and 12.9%. Conclusion: The applicator created via 3D printing delivers a lower dose to the bladder and the rectum while keeping the same coverage to HR-CTV as other commercially available applicators. Additionally, the new applicator resulted in a reduction of treatment time, which is always welcome.

60 APPLIED LIFE SCIENCES↗

Spatiotemporal filtering of MR-temperature artifacts arising from bowel motion during transurethral MR-HIFU

Purpose: Transurethral MR-HIFU is a minimally invasive image-guided treatment for localized prostate cancer that enables precise targeting of tissue within the gland. The treatment is performed within a clinical MRI to obtain real-time MR thermometry used as an active feedback to control the spatial heating pattern in the prostate and to monitor for potential damage to surrounding tissues. This requires that the MR thermometry measurements are an accurate representation of the true tissue temperature. The proton resonance frequency shift thermometry method used is sensitive to tissue motion and changes in the local magnetic susceptibility that can be caused by the motion of air bubbles in the rectum, which can impact the performance of transurethral MR-HIFU in these regions of the gland. Methods: A method is proposed for filtering of temperature artifacts based on the temporal variance of the temperature, using empirical and dynamic positional knowledge of the ultrasonic heating beam, and an estimation of the measurement noise. A two-step correction strategy is introduced which eliminates artifact-detected temperature variations while keeping the noise level low through spatial averaging. Results: The filter has been evaluated by postprocessing data from five human transurethral ultrasound treatments. The two-step correction process led to reduced final temperature standard deviation in the prostate and rectum areas where the artifact was located, without negatively affecting areas distal to the artifact. The performance of the filter was also found to be consistent across all six of the data sets evaluated. The evaluation of the detection criterion parameter M determined that a value of M = 3 achieves a conservative filter with minimal loss of spatial resolution during the process. Conclusions: The filter was able to remove most artifacts due to the presence of moving air bubbles in the rectum during transurethral MR-HIFU. A quantitative estimation of the filter capabilities shows a systematic improvement in the standard deviation of the corrected temperature maps in the rectum zone as well as in the entire acquired slice.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of atlas-based auto-segmentation software in prostate cancer patients

The performance and limitations of an atlas-based auto-segmentation software package (ABAS; Elekta Inc.) was evaluated using male pelvic anatomy as the area of interest. Contours from 10 prostate patients were selected to create atlases in ABAS. The contoured regions of interest were created manually to align with published guidelines and included the prostate, bladder, rectum, femoral heads and external patient contour. Twenty-four clinically treated prostate patients were auto-contoured using a randomised selection of two, four, six, eight or ten atlases. The concordance between the manually drawn and computer-generated contours were evaluated statistically using Pearson's product–moment correlation coefficient (r) and clinically in a validated qualitative evaluation. In the latter evaluation, six radiation therapists classified the degree of agreement for each structure using seven clinically appropriate categories. The ABAS software generated clinically acceptable contours for the bladder, rectum, femoral heads and external patient contour. For these structures, ABAS-generated volumes were highly correlated with ‘as treated’ volumes, manually drawn; for four atlases, for example, bladder r = 0.988 (P < 0.001), rectum r = 0.739 (P < 0.001) and left femoral head r = 0.560 (P < 0.001). Poorest results were seen for the prostate (r = 0.401, P < 0.05) (four atlases); however this was attributed to the comparison prostate volume being contoured on magnetic resonance imaging (MRI) rather than computed tomography (CT) data. For all structures, increasing the number of atlases did not consistently improve accuracy. ABAS-generated contours are clinically useful for a range of structures in the male pelvis. Clinically appropriate volumes were created, but editing of some contours was inevitably required. The ideal number of atlases to improve generated automatic contours is yet to be determined.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Multi-institutional Clinical Trial of Rectal Dose Reduction via Injected Polyethylene-Glycol Hydrogel During Intensity Modulated Radiation Therapy for Prostate Cancer: Analysis of Dosimetric Outcomes

Purpose: To characterize the effect of a prostate-rectum spacer on dose to rectum during external beam radiation therapy for prostate cancer and to assess for factors correlated with rectal dose reduction. Methods and Materials: Fifty-two patients at 4 institutions were enrolled into a prospective pilot clinical trial. Patients underwent baseline scans and then were injected with perirectal spacing hydrogel and rescanned. Intensity modulated radiation therapy plans were created on both scans for comparison. The objectives were to establish rates of creation of ≥7.5 mm of prostate-rectal separation, and decrease in rectal V70 of ≥25%. Multiple regression analysis was performed to evaluate the associations between preinjection and postinjection changes in rectal V70 and changes in plan conformity, rectal volume, bladder volume, bladder V70, planning target volume (PTV), and postinjection midgland separation, gel volume, gel thickness, length of PTV/gel contact, and gel left-to-right symmetry. Results: Hydrogel resulted in ≥7.5-mm prostate-rectal separation in 95.8% of patients; 95.7% had decreased rectal V70 of ≥25%, with a mean reduction of 8.0 Gy. There were no significant differences in preinjection and postinjection prostate, PTV, rectal, and bladder volumes. Plan conformities were significantly different before versus after injection (P=.02); plans with worse conformity indexes after injection compared with before injection (n=13) still had improvements in rectal V70. In multiple regression analysis, greater postinjection reduction in V70 was associated with decreased relative postinjection plan conformity (P=.01). Reductions in V70 did not significantly vary by institution, despite significant interinstitutional variations in plan conformity. There were no significant relationships between reduction in V70 and the other characteristics analyzed. Conclusions: Injection of hydrogel into the prostate-rectal interface resulted in dose reductions to rectum for >90% of patients treated. Rectal sparing was statistically significant across a range of 10 to 75 Gy and was demonstrated within the presence of significant interinstitutional variability in plan conformity, target definitions, and injection results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intrafraction Prostate Translations and Rotations During Hypofractionated Robotic Radiation Surgery: Dosimetric Impact of Correction Strategies and Margins

Purpose: To investigate the dosimetric impact of intrafraction prostate motion and the effect of robot correction strategies for hypofractionated CyberKnife treatments with a simultaneously integrated boost. Methods and Materials: A total of 548 real-time prostate motion tracks from 17 patients were available for dosimetric simulations of CyberKnife treatments, in which various correction strategies were included. Fixed time intervals between imaging/correction (15, 60, 180, and 360 seconds) were simulated, as well as adaptive timing (ie, the time interval reduced from 60 to 15 seconds in case prostate motion exceeded 3 mm or 2° in consecutive images). The simulated extent of robot corrections was also varied: no corrections, translational corrections only, and translational corrections combined with rotational corrections up to 5°, 10°, and perfect rotational correction. The correction strategies were evaluated for treatment plans with a 0-mm or 3-mm margin around the clinical target volume (CTV). We recorded CTV coverage (V{sub 100%}) and dose-volume parameters of the peripheral zone (boost), rectum, bladder, and urethra. Results: Planned dose parameters were increasingly preserved with larger extents of robot corrections. A time interval between corrections of 60 to 180 seconds provided optimal preservation of CTV coverage. To achieve 98% CTV coverage in 98% of the treatments, translational and rotational corrections up to 10° were required for the 0-mm margin plans, whereas translational and rotational corrections up to 5° were required for the 3-mm margin plans. Rectum and bladder were spared considerably better in the 0-mm margin plans. Adaptive timing did not improve delivered dose. Conclusions: Intrafraction prostate motion substantially affected the delivered dose but was compensated for effectively by robot corrections using a time interval of 60 to 180 seconds. A 0-mm margin required larger extents of additional rotational corrections than a 3-mm margin but resulted in lower doses to rectum and bladder.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of On-Board kV Cone Beam Computed Tomography–Based Dose Calculation With Deformable Image Registration Using Hounsfield Unit Modifications

Purpose: The purpose of this study was to estimate the accuracy of the dose calculation of On-Board Imager (Varian, Palo Alto, CA) cone beam computed tomography (CBCT) with deformable image registration (DIR), using the multilevel-threshold (MLT) algorithm and histogram matching (HM) algorithm in pelvic radiation therapy. Methods and Materials: One pelvis phantom and 10 patients with prostate cancer treated with intensity modulated radiation therapy were studied. To minimize the effect of organ deformation and different Hounsfield unit values between planning CT (PCT) and CBCT, we modified CBCT (mCBCT) with DIR by using the MLT (mCBCT{sub MLT}) and HM (mCBCT{sub HM}) algorithms. To evaluate the accuracy of the dose calculation, we compared dose differences in dosimetric parameters (mean dose [D{sub mean}], minimum dose [D{sub min}], and maximum dose [D{sub max}]) for planning target volume, rectum, and bladder between PCT (reference) and CBCTs or mCBCTs. Furthermore, we investigated the effect of organ deformation compared with DIR and rigid registration (RR). We determined whether dose differences between PCT and mCBCTs were significantly lower than in CBCT by using Student t test. Results: For patients, the average dose differences in all dosimetric parameters of CBCT with DIR were smaller than those of CBCT with RR (eg, rectum; 0.54% for DIR vs 1.24% for RR). For the mCBCTs with DIR, the average dose differences in all dosimetric parameters were less than 1.0%. Conclusions: We evaluated the accuracy of the dose calculation in CBCT, mCBCT{sub MLT}, and mCBCT{sub HM} with DIR for 10 patients. The results showed that dose differences in D{sub mean}, D{sub min}, and D{sub max} in mCBCTs were within 1%, which were significantly better than those in CBCT, especially for the rectum (P<.05). Our results indicate that the mCBCT{sub MLT} and mCBCT{sub HM} can be useful for improving the dose calculation for adaptive radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-volume and radiobiological dependence on the calculation grid size in prostate VMAT planning

This study evaluated the effects of dose-volume and radiobiological dependence on the calculation grid size in prostate volumetric-modulated arc therapy (VMAT) planning. Ten patients with prostate cancer were selected for this retrospective treatment planning study. Prostate VMAT plans were created for the patients using the 6 MV photon beam produced by a Varian TrueBEAM linac with the calculation grid size equal to 1, 2, 2.5, 3, 4, and 5 mm. Dose-volume histograms (DVHs) of targets and organs at risk were generated for different grid sizes. We calculated the radiobiological parameters of the tumor control probability (TCP) of clinical target volume (CTV) and planning target volume (PTV), and the normal tissue complication probability (NTCP) of organs at risk (rectal wall, rectum, bladder wall, bladder, left femur, and right femur). The homogeneity, conformity, and gradient indexes of CTV and PTV were calculated for different grid sizes. The TCP of PTV was found decreasing with a rate of 0.06%/mm when the calculation grid size increased from 1 to 5 mm. On the other hand, both NTCPs of rectal wall and rectum were found decreasing with rates of 0.03%/mm and 0.05%/mm, respectively, with an increase of grid size. The homogeneity index of PTV increased with a rate of 0.57/mm of the calculation grid size, whereas the conformity index of PTV decreased with a rate of 0.0075/mm. The gradient index of PTV was found increasing with a rate equal to 0.05/mm. In prostate VMAT planning, variations of dose-volume and radiobiological parameters with calculation grid size on PTV, rectal wall, and rectum were more significant than those of CTV and other organs at risk such as bladder wall, bladder, and femurs. Results in this study are important in the treatment planning quality assurance when the calculation grid size is varied to compromise a shorter dose computing time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment and management of interfractional variations in daily diagnostic-quality-CT guided prostate-bed irradiation after prostatectomy

Purpose: To quantify interfractional anatomic variations and limitations of the current practice of image-guided radiation therapy (IGRT) for prostate-bed patients and to study dosimetric benefits of an online adaptive replanning scheme that addresses the interfractional variations. Methods: Contours for the targets and organs at risk (OARs) from daily diagnostic-quality CTs acquired with in-room CT (CTVision, Siemens) were generated by populating the planning contours using an autosegmentation tool based on deformable registration (ABAS, Elekta) with manual editing for ten prostate-bed patients treated with postoperative daily CT-guided IMRT. Dice similarity coefficient (DSC) obtained by maximizing the overlap of contours for a structure between the daily and plan contours was used to quantify the organ deformation between the plan and daily CTs. Three interfractional-variation-correction schemes, the current standard practice of IGRT repositioning, a previously developed online adaptive RT (ART), and the full reoptimization, were applied to these daily CTs and a number of dose-volume quantities for the targets and organs at risk were compared for their effectiveness to account for the interfractional variations. Results: Large interfractional organ deformations in prostate-bed irradiation were seen. The mean DSCs for CTV, rectum, and bladder were 86.6 ± 5.1% (range from 61% to 97%), 77.3% ± 7.4% (range from 55% to 90%), and 75.4% ± 11.2% (range from 46% to 96%), respectively. The fractional and cumulative dose-volume quantities for CTV and PTV: V100 (volume received at least 100% prescription dose), and rectum and bladder: V{sub 45Gy} and V{sub 60Gy} (volume received at least 45 or 60 Gy), were compared for the repositioning, adaptive, reoptimization, and original plans. The fractional and cumulative dosimetric results were nearly the same. The average cumulative CTV V100 were 88.0%, 98.4%, 99.2%, and 99.3% for the IGRT, ART, reoptimization, and original plans, respectively. The corresponding rectal V{sub 45Gy} (V{sub 60Gy}) were 58.7% (27.3%), 48.1% (20.7%), 43.8% (16.1%), and 44.9% (16.8%). The results for bladder were comparable among three schemes. Paired two-tailed Wilcoxon signed-rank tests were performed and it was found that ART and reoptimization provide better target coverage and better OAR sparing, especially rectum sparing. Conclusions: The interfractional organ motions and deformations during prostate-bed irradiation are significant. The online adaptive replanning scheme is capable of effectively addressing the large organ deformation, resulting in cumulative doses equivalent to those originally planned.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-27: Appropriateness Criteria for Deformable Image Registration and Dose Propagation

Purpose: Several commercial software packages have been recently released that allow the user to apply deformable registration algorithms (DRA) for image fusion and dose propagation. Although the idea of anatomically tracking the daily patient dose in the context of adaptive radiotherapy or merely adding the dose from prior treatment to the current one is very intuitive, the accuracy and applicability of such algorithms needs to be investigated as it remains somewhat subjective. In our study, we used true anatomical data where we introduced changes in the density, volume and location of segmented structures to test the DRA for its sensitivity and accuracy. Methods: The CT scan of a prostate patient was selected for this study. The CT images were first segmented to define structure such as the PTV, bladder, rectum, intestines and pelvic bone anatomy. To perform our study, we introduced anatomical changes in the reference patient image set in three different ways: (i) we kept the segmented volumes constant and changed the density of rectum and bladder in increments of 5% (ii) we changed the volume of rectum and bladder in increments of 5% and (iii) we kept the segmented volumes constant but changed their location by moving their COM in increments of 3mm. Using the Velocity software, we evaluated the accuracy of the DRA for each incremental change in all three scenarios. Results: The DRA performs reasonably well when the differential density difference against the background is more than 5%. For the volume change study, the DRA results became unreliable for relative volume changes greater than 10%. Finally for the location study, the DRA performance was acceptable for shifts below 9mm. Conclusion: Site specific and patient specific QA for DRA is an important step to evaluate such algorithms prior to their use for dose propagation.

60 APPLIED LIFE SCIENCES↗

SU-E-J-62: Estimating Plausible Treatment Course Dose Distributions by Accounting for Registration Uncertainty and Organ Motion

Purpose: Dose accumulation following deformable image registration (DIR) is challenging. In this study, we used a statistical sampling approach, which takes into account both DIR uncertainties and patient-specific organ motion, to study the distribution of possible true dose distributions. Methods: The study included ten patients (six CT scans/patient) treated with radiotherapy for prostate cancer. For each patient, the planned dose was re-calculated on the repeated geometries, following rigid registration based on fiducial markers. The dose re-calculated on the first CT served as our snapshot dose distribution (D1) and the average of the first five repeat scans as our treatment course reference dose distribution (Dref). Patient-specific motion and DIR-uncertainties, at each voxel in CT1, were assessed using a previously developed DIR performance measure, the distance discordance metric (DDM). To sample the distribution of possible true, predicted dose distributions (Dpred), we resampled D1 by perturbing the location of each voxel with the corresponding DDM. The three dose distribution approaches are compared for the rectum and the bladder. Results: The bladder generalized equivalent uniform dose (gEUD) from the averaged Dpred was closer to the gEUDref than to the gEUD1 (difference: 0.6 vs. 1.0 Gy). For both structures, the gEUDpred was higher than the gEUDref, and significantly higher (p≤0.05) for the rectum (average: 50.8 Gy vs. 48.0 Gy). Conclusion: We have shown that the bladder gEUD values resulting from our DIR-uncertainty inclusive dose sampling approach, Dpred, were closer to the gEUD from Dref than the gEUD values from D1. For the rectum, gEUDpred overestimated gEUDref. Theoretically however, gEUDpred values, sampled from DDM uncertainties are more representative of dose uncertainties.

60 APPLIED LIFE SCIENCES↗

SU-E-T-125: Dosimetric Comparison of Intensity Modulated Radiation Therapy Using Robotic Versus Traditional Linac Platform in Prostate Cancer

Purpose: Recent development of an MLC for robotic external beam radiotherapy has the potential of new clinical application in conventionally fractionated radiation therapy. This study offers a dosimetric comparison of IMRT plans using Cyberknife with MLC versus conventional linac plans. Methods: Ten prostate cancer patients treated on a traditional linac with IMRT to 7920cGy at 180cGy/fraction were randomly selected. GTVs were defined as prostate plus proximal seminal vesicles. PTVs were defined as GTV+8mm in all directions except 5mm posteriorly. Conventional IMRT planning was performed on Philips Pinnacle and delivered on a standard linac with CBCT and 10mm collimator leaf width. For each case a Cyberknife plan was created using Accuray Multiplan with same CT data set, contours, and dose constraints. All dosimetric data was transferred to third party software for independent computation of contour volumes and DVH. Delivery efficiency was evaluated using total MU, treatment time, number of beams, and number of segments. Results: Evaluation criteria including percent target coverage, homogeneity index, and conformity index were found to be comparable. All dose constraints from QUANTEC were found to be statistically similar except rectum V50Gy and bladder V65Gy. Average rectum V50Gy was lower for robotic IMRT (30.07%±6.57) versus traditional (34.73%±3.62, p=0.0130). Average bladder V65Gy was lower for robotic (17.87%±12.74) versus traditional (21.03%±11.93, p=0.0405). Linac plans utilized 9 coplanar beams, 48.9±3.8 segments, and 19381±2399MU. Robotic plans utilized 38.4±9.0 non-coplanar beams, 85.5±21.0 segments and 42554.71±16381.54 MU. The average treatment was 15.02±0.60 minutes for traditional versus 20.90±2.51 for robotic. Conclusion: The robotic IMRT plans were comparable to the traditional IMRT plans in meeting the target volume dose objectives. Critical structure dose constraints were largely comparable although statistically significant differences were found in favor of the robotic platform in terms of rectum V50Gy and bladder V65Gy at a cost of 25% longer treatment time.

60 APPLIED LIFE SCIENCES↗

SU-E-T-620: Dosimetric Compliance Study for a New Prostate Protocol of Combined High Dose Rate Brachytherapy and Stereotactic Body Radiotherapy

Purpose: To investigate the adherence of treatment plans of prostate cancer patients with the dosimetric compliance criteria of the new in house phase I trial of high dose rate (HDR) brachytherapy combined with stereotactic body radiotherapy (SBRT) for intermediate risk prostate cancer patients. Methods: Ten prostate cancer patients were treated using this trial. They received one fraction of HDR to 15Gy, followed by external beam(EB) boost of 3.2Gy(Level 1, five patients) or 3.94Gy(level 2, five patients) per fraction for 10 or 7 fractions, respectively, both equivalent to EB treatments of 113.5Gy in 2Gy fractions. The EB plans were either IMRT or VMAT plans. DVH analysis was performed to verify the adherence of treatment plans to the dosimetric criteria of the trial. Results: For Level 1 patients, target coverage were adequate, with CTV V32Gy(%) of 99.0±1.0 (mean ± 1 standard deviation), and PTV V31Gy(%) of 99.6±0.3. PTV V32.9Gy(%) is 1.4±3.1 and PTVmax is 32.9±0.2Gy. Rectum, bladder and femoral heads sparing were well within protocol criteria. For Level 2 patients, CTV V27.6Gy(%) is 98.7±1.8; PTV V26.7Gy(%) is 99.0±1.4. PTV V28.4Gy(%) is 1.3±1.4, with three patients having minor deviation from protocol. Again critical structures were spared compliant to the protocol. The analysis of HDR plans show similar results, with adequate dose coverage to the prostate and sparing of critical structures including urethra and rectum. V100(%) and V90(%) of prostate are 96.0±1.1 and 98.9±0.5. Urethra D10(%) is 113.1±2.9. Rectum V80(cc) is 1.4±0.5. Hotspot in prostate is substantially higher than what the protocol specifies. But the criteria for hotspot are only guidelines, serving to lower the dose to urethra . Conclusion: This new high biological equivalent dose prostate trial has been carried out successfully for ten patients. Based on dosimetric analysis, all HDR and external plans were compliant to the protocol criteria, with only minor deviations.

60 APPLIED LIFE SCIENCES↗

SU-F-BRD-11: Prediction of Dosimetric Endpoints From Patient Geometry Using Neural Nets

Purpose: The previously-published overlap volume histogram (OVH) technique lends itself naturally to prediction of the dose received by a given volume of tissue (e.g. D90) in intensity-modulated radiotherapy (IMRT) treatment plans. Here we extend the OVH technique using artificial neural networks in order to predict the volume of tissue receiving a given dose (e.g. V90) in both prostate IMRT and conventional breast radiotherapy. Methods: Twenty-nine prostate treatment plans and forty-three breast treatment plans were analyzed. The spatial relationships between the prostate and rectum and between the breast and ipsilateral lung were characterized using OVHs. The OVH is a cumulative histogram representing the fractional volume of the risk organ overlapped by a series of isotropic expansions of the planning target volume (PTV). Seven cases were identified as outliers and replanned. OVH points were used as inputs to a one hidden layer feed forward artificial neural network with quality parameters of the corresponding plan, such as the rectum V50, as targets. A 3-fold cross-validation was used to estimate the prediction error. Results: The root mean square (RMS) error between the predicted rectum V50s and the planned values was 2.3, which was 35% of the standard deviation of V50 for the twenty-nine plans. The RMS error of prediction of V20 of the ipsilateral lung in breast cases was 3.9, which was 90% of the standard deviation of the V20 values in the breast plan database. Conclusion: This study demonstrates that artificial neural nets can be used to extend the OVH technique to predict dosimetric endpoints taking the form of a volume receiving a given dose, rather than the minimum dose received by a given volume. Prediction of ipsilateral lung dose in breast radiotherapy using the OVH technique remains a work in progress.

60 APPLIED LIFE SCIENCES↗