Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RECOILS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Search for MeV electron recoils from dark matter in EXO-200

We present a search for electron-recoil signatures from the charged-current absorption of fermionic dark matter using the EXO-200 detector. We report an average electron-recoil background rate of 6.8×10 4 ⁢cts ⁢kg −1 yr −1 keV −1 above 4 MeV and find no statistically significant excess over our background projection. Using a total 136 Xe exposure of 234.1 kg yr, we exclude new parameter space for the charged-current absorption cross section for dark matter masses between 𝑚𝜒=2.6–11.6 MeV with a minimum of 6×10 −51 cm 2 at 8.3 MeV at the 90% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron capture-induced nuclear recoils as background for CE$v$⁢NS measurements at reactors

Nuclear reactors represent a promising neutrino source for CE⁢v⁢NS (coherent-elastic neutrino-nucleus scattering) searches. However, reactor sites also come with high ambient neutron flux. Neutron capture-induced nuclear recoils can create a spectrum that strongly overlaps the CEv⁢NS signal for recoils ≲100 eV for nuclear reactor measurements in silicon or germanium detectors. This background can be particularly critical for low-power research reactors providing a moderate neutrino flux. Here, in this work we quantify the impact of this background and show that, for a measurement 10 m from a 1 MW reactor, the effective thermal neutron flux should be kept below ~7 × 10 –4 ⁢n/cm 2 s so that the CE⁢v⁢NS events can be measured at least at a 5⁢σ level with germanium detectors in 100 kg yr exposure time. This flux corresponds to 60% of the sea-level flux but needs to be achieved in a nominally high-flux (reactor) environment. Improved detector resolution can help the measurements, but the thermal flux is the key parameter for the sensitivity of the experiment. For silicon detectors, the constraint is even stronger and thermal neutron fluxes must be near an order of magnitude lower. This constraint highlights the need of an effective thermal neutron mitigation strategy for future low threshold CEv⁢NS searches. In particular, the neutron capture-induced background can be efficiently reduced by active veto systems tagging the deexcitation gamma following the capture.

79 ASTRONOMY AND ASTROPHYSICS↗

Anharmonic effects in nuclear recoils from sub-GeV dark matter

Direct detection experiments are looking for nuclear recoils from scattering of sub-GeV dark matter (DM) in crystals, and have thresholds as low as ∼ 10 eV or DM masses of ∼ 100 MeV . Future experiments are aiming for even lower thresholds. At such low energies, the free nuclear recoil prescription breaks down, and the relevant final states are phonons in the crystal. Scattering rates into single as well as multiple phonons have already been computed for a harmonic crystal. However, crystals typically exhibit some anharmonicity, which can significantly impact scattering rates in certain kinematic regimes. In this work, we estimate the impact of anharmonic effects on scattering rates for DM in the mass range ∼ 1 – 10 MeV , where the details of multiphonon production are most important. Using a simple model of a nucleus in a bound potential, we find that anharmonicity can modify the scattering rates by up to two orders of magnitude for DM masses of O ( MeV ) . However, such effects are primarily present at high energies where the rates are suppressed, and thus only relevant for very large DM cross sections. We show that anharmonic effects are negligible for masses larger than ∼ 10 MeV . Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Search for the Migdal effect in liquid xenon with keV-level nuclear recoils

The Migdal effect predicts that a nuclear recoil interaction can be accompanied by atomic ionization, allowing many dark matter direct detection experiments to gain sensitivity to sub-GeV masses. We report the first direct search for the Migdal effect for M- and L-shell electrons in liquid xenon using nuclear recoils produced by tagged neutron scatters. Despite an observed background rate lower than that of expected signals in the region of interest, we do not observe a signal consistent with predictions. We discuss possible explanations, including inaccurate predictions for either the Migdal rate or the signal response in liquid xenon. We comment on the implications for direct dark matter searches and future Migdal characterization efforts. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Daily modulation of low-energy nuclear recoils from sub-GeV dark matter

At sufficiently low nuclear recoil energy, the scattering of dark matter (DM) in crystals gives rise to single phonon and multiphonon excitations. In anisotropic crystals, the scattering rate into phonons modulates over each sidereal day as the crystal rotates with respect to the DM wind. This gives a potential avenue for directional detection of DM. The daily modulation for single phonons has previously been calculated. Here we calculate the daily modulation for multiphonon excitations from DM in the mass range 1 MeV–1 GeV. We generalize previous multiphonon calculations, which made an isotropic approximation, and implement results in the DarkELF package. We find daily modulation rates up to 1%–10% for an Al 2 O 3 target and DM mass below 30 MeV, depending on the recoil energies probed. We obtain similar results for SiC, while modulation in Si, GaAs, and SiO 2 is negligible. Published by the American Physical Society 2025

Stratman, Connor↗

Impact of Clustering on the Li 8 β Decay and Recoil Form Factors

We place unprecedented constraints on recoil corrections in the β decay of 8 Li, by identifying a strong correlation between them and the 8 Li ground state quadrupole moment in large-scale ab initio calculations. The results are essential for improving the sensitivity of high-precision experiments that probe the weak interaction theory and test physics beyond the standard model. In addition, our calculations predict a 2 + state of the α + α system that is energetically accessible to β decay but has not been observed in the experimental 8 Be energy spectrum, and has an important effect on the recoil corrections and β decay for the A = 8 systems. Furthermore, this state and an associated 0 + state are notoriously difficult to model due to their cluster structure and collective correlations, but become feasible for calculations in the ab initio symmetry-adapted no-core shell-model framework.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

β -Nuclear-Recoil Correlation from $^6$$\mathrm{He}$ Decay in a Laser Trap

Here, we report the first precise measurement of a β-recoil correlation from a radioactive noble gas ( 6 He) confined via a magneto-optical trap. The measurement is motivated by the search for exotic tensor-type contributions to the charged weak current. Interpreted as tensor currents with right-handed neutrinos, the measurements yield |C T /C A | 2 ≤ 0.022 (90% confidence limit, C.L.). On the other hand, for left-handed neutrinos the limits are 0.007 < C T /C A < 0.111 (90% C.L.). The sensitivity of the present measurement is mainly limited by experimental uncertainties in determining the time response properties and the distance between the atom cloud and the microchannel plate used for recoil ion detection.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Recoil Calibration at Sub-keV Energies in LUX and Its Impact on Dark Matter Search Sensitivity

Dual-phase xenon time projection chamber (TPC) detectors offer heightened sensitivities for dark matter detection across a spectrum of particle masses. To broaden their capability to low-mass dark matter interactions, we investigated the light and charge responses of liquid xenon (LXe) to sub-keV nuclear recoils. Using neutron events from a pulsed Adelphi Deuterium-Deuterium neutron generator, an in situ calibration was conducted on the LUX detector. We demonstrate direct measurements of light and charge yields down to 0.45 keV and 0.27 keV, respectively, both approaching single quanta production, the physical limit of LXe detectors. Furthermore, these results hold significant implications for the future of dual-phase xenon TPCs in detecting low-mass dark matter via nuclear recoils.

Dark matter detectors↗

A search for new physics in low-energy electron recoils from the first LZ exposure

Searches for new physics signatures in low-energy electron recoils using a fiducial LXe mass of 5.5±0.2 t tonnes over a period of 60±1 live days. The following evidences of recoiling electrons from interactions with; - Solar axions - Axion-like particles - Hidden photons - Solar neutrino magnetic moment - Solar neutrino millicharge are investigated in the study. Data reported here are from Science Run 1, which ran from 23 Dec 2021 to 11 May 2022 under stable detector conditions. Single-scatter (SS) reconstruction and analysis cuts are applied to data, and the region of interest (ROI) is defined as follows; - in the range of 3–80 phd for S1c. - in the range of uncorrected S2 greater than 600 phd and S2c less than 10^{5} phd for S2c.

Source record↗

A Primer on Nuclear "Recoil" Data

For many years the ENDF-6 format has existed to contain evaluated nuclear data. One primary driver for the format and the data is neutron transport calculations. Evaluated data can be processed by a code like NJOY into either continuous energy form (ACE format) for Monte Carlo codes like MCNP or into multi-group form (NDI tables) for deterministic codes like Partisn. The reaction cross sections are found in the MF 3 section of the ENDF-6 format. If the reaction produces one or more neutrons as outputs, then secondary neutron data must also be given in MF 4,5 or 6 sections of the format. Energy and angular distributions for the output neutrons must be given in one of several available formats. The most general formats are found in MF 6. MF 4 is for angular distributions, MF 5 is for Energy distributions, and MF 6 contains both. In recent years, more interest has developed in the other output particles (i.e., the “recoil” particles) from neutron induced reactions. This has been driven by interest in charged particle transport and in more specialized partial kermas. ( A separate total neutron kerma has been available for a long time.) Partial kermas are a breakdown of the Kinetic Energy Released into the MAterial by output particle or by neutron reaction. The sum of the partial kermas should be equal to the total kerma on a group-wise basis. The ENDF-6 format is general enough for these new data requirements. Ideally, evaluated data would exist for every output particle (including the secondary neutrons) from every neutron-induced reaction. In the MF 6 format section, data for multi-particle outputs may be entered using the LAW =1 option. This option explicitly allows energy and angular output distributions for each particle produced in the reaction. Such information should preserve the balance between partial kermas and the total kerma at the groupwise level as well as the individual particle averaged energies. For simpler 2-body reactions, LAW = 2 is available. This allows the evaluation to specify only enough data to specify the 2-body reaction fully. Such a simplification does not exist for 3 (or more) body breakups. A simplified form of LAW 2, i.e., LAW 3, also exists to generate approximate recoil output distributions in the absence of full data. However, evaluated data does not generally exist at this fine granularity for reactions involving more than 2 output particles ( e.g., the 3-body break-up reaction). When the multi-body detailed output distribution data is not available, LAW=6 may be employed in NJOY. LAW 6 produces approximate output distributions for all the particles produced in the reaction. Just like in the 2-body case, the smaller particles will generally carry off more energy. At any particular energy, the balance between the sum of the partial kermas and the total kerma will not necessarily be preserved. However, the average energy of each output particle from a reaction is preserved.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spin-Density Matrix Elements in K∗(892) Photoproduction with Recoiling Λ at GlueX

We report on the measurement of spin-density matrix elements for the K∗(892) → K+π0 photoproduction process with a recoiling Λ hyperon. The measurement used high-statistics GlueX data from photoproduction off a proton target at photon energies between 8.2 and 8.8 GeV, in a kinematic regime dominated by t-channel exchange processes. GlueX is a fixed-target experiment with a linearly polarized photon beam and a nearly 4π hermetic detector, allowing extraction of the full spin observ- ables from both the K+π0 and Λ → π−p systems. The GlueX data show clear evidence of the K∗(892) resonance in the K+π0 mass spectrum, along with additional structures at higher masses that may correspond to K∗0 or K∗2 resonances. The precise measurement of the spin-density matrix elements of the K∗(892) could serve as a standard candle for con- tinuing studies of higher-mass excited K∗ states. In addition, t-channel K∗ photoproduction differs from previous measurements of non-strange vector meson photoproduction, as it is free from Pomeron exchange and is virtually unexplored in this energy regime. Furthermore, the unprece- dented data collected by GlueX allow for investigations of correlations between the Λ polarization and the spin-density matrix elements of K∗ production, paving the way for future partial-wave analyses with full spin information involving the recoil hyperon.

Li, Hao [College of William and Mary, Williamsburg↗

Extremely Low Energy Nuclear Recoil Calibrations for Dark Matter Direct Detection (Final Technical Report)

This project developed and demonstrated a new calibration approach for low-energy nuclear recoils in solid-state detectors based on neutron capture. Precise calibration in the sub-keV regime is a critical challenge across the HEP portfolio. Existing measurements show deviations and inconsistencies across methods. Neutron capture provides a complementary approach producing discrete recoils via γ cascades.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutrino Transport with Monte Carlo Method. I. Toward Fully Consistent Implementation of Nucleon Recoils in Core-collapse Supernova Simulations

The small energy exchange via nucleon recoils in neutrino–nucleon scattering is now supposed to be one of the important factors for successful explosions of core-collapse supernovae (CCSNe), as they can change neutrino spectra through accumulation of a large number of scatterings. In deterministic methods employed for neutrino transport in CCSN simulations, we normally cannot afford to deploy a large enough number of energy bins needed to resolve this small energy exchange, and subgrid techniques are employed one way or another. In this paper, we study quantitatively with the Monte Carlo (MC) method how well such a treatment performs. We first investigate the effects of nucleon recoils on the neutrino spectra and confirm that the average energy is reduced by ~15% for heavy-lepton neutrinos and much smaller amounts for other types of neutrinos in a typical postbounce situation. It is also observed that the nucleon scattering dominates the electron scattering in the thermalization of neutrino spectra in all flavors. We then study possible artifacts that the coarse energy grid may produce in the deterministic methods. In order to mimic the latter calculation, we redistribute MC particles in each energy bin after a certain interval in a couple of ways and study how the results are affected, depending on the energy resolution. We also discuss the possible implications of our results for the deterministic methods.

79 ASTRONOMY AND ASTROPHYSICS↗

Relationship between early diastolic intraventricular pressure gradients, an index of elastic recoil, and improvements in systolic and diastolic function

BACKGROUND: Early diastolic intraventricular pressure gradients (IVPGs) have been proposed to relate to left ventricular (LV) elastic recoil and early ventricular "suction." Animal studies have demonstrated relationships between IVPGs and systolic and diastolic indices during acute ischemia. However, data on the effects of improvements in LV function in humans and the relationship to IVPGs are lacking. METHODS AND RESULTS: Eight patients undergoing CABG and/or infarct exclusion surgery had a triple-sensor high-fidelity catheter placed across the mitral valve intraoperatively for simultaneous recording of left atrial (LA), basal LV, and apical LV pressures. Hemodynamic data obtained before bypass were compared with those with similar LA pressures and heart rates obtained after bypass. From each LV waveform, the time constant of LV relaxation (tau), +dP/dt(max), and -dP/dt(max) were determined. Transesophageal echocardiography was used to determined end-diastolic (EDV) and end-systolic (ESV) volumes and ejection fractions (EF). At similar LA pressures and heart rates, IVPG increased after bypass (before bypass 1.64+/-0.79 mm Hg; after bypass 2.67+/-1.25 mm Hg; P<0.01). Significant improvements were observed in ESV, as well as in apical and basal +dP/dt(max), -dP/dt(max), and tau (each P<0.05). Overall, IVPGs correlated inversely with both ESV (IVPG=-0.027[ESV]+3.46, r=-0.64) and EDV (IVPG=-0.027[EDV]+4.30, r=-0.70). Improvements in IVPGs correlated with improvements in apical tau (Deltatau =5.93[DeltaIVPG]+4.76, r=0.91) and basal tau (Deltatau =2.41[DeltaIVPG]+5.13, r=-0.67). Relative changes in IVPGs correlated with changes in ESV (DeltaESV=-0.97[%DeltaIVPG]+23.34, r=-0.79), EDV (DeltaEDV=-1.16[%DeltaIVPG]+34.92, r=-0.84), and EF (DeltaEF=0.38[%DeltaIVPG]-8.39, r=0.85). CONCLUSIONS: Improvements in LV function also increase IVPGs. These changes in IVPGs, suggestive of increases in LV suction and elastic recoil, correlate directly with improvements in LV relaxation and ESV.

Non-NASA Center↗

Temperature Dependence and Recoil-free Fraction Effects in Olivines Across the Mg-Fe Solid Solution

Olivine and pyroxene are the major ferromagnesian minerals in most meteorite types and in mafic igneous rocks that are dominant at the surface of the Earth. It is probable that they are the major mineralogical components at the surface of any planetary body that has undergone differentiation processes. In situ mineralogical studies of the rocks and soils on Mars suggest that olivine is a widespread mineral on that planet s surface (particularly at the Gusev site) and that it has been relatively unaffected by alteration. Thus an understanding of the characteristics of Mossbauer spectra of olivine is of great importance in interpreting MER results. However, variable temperature Mossbauer spectra of olivine, which are needed to quantify recoil-free fraction effects and to understand the temperature dependence of olivine spectra, are lacking in the literature. Thus, we present here a study of the temperature dependence and recoil-free fraction of a series of synthetic olivines.

Sklute, E. C.↗

The Final Merger of Massive Black Holes: Recoils, Gravitational Waves, and Electromagnetic Signatures

The final merger of two massive black holes produces a powerful burst of gravitational radiation, emitting more energy than all the stars in the observable universe combined. The resulting gravitational waveforms will be easily detectable by the space-based LISA out to redshifts z > 10, revealing the masses and spins ofthe black holes to high precision. If the merging black holes have unequal masses, or asymmetric spins, the final black hole that forms can recoil with a velocity exceeding 1000 km/s. And, when the black holes merge in the presence of gas and magnetic fields, various types of electromagnetic signals may also be produced. For more than 30 years, scientists have tried to compute black hole mergers using the methods of numerical relativity. The resulting computer codes have been plagued by instabilities, causing them to crash well before the black holes in the binary could complete even a single orbit. Within the past few years, however, this situation has changed dramatically, with a series of remarkable breakthroughs. This talk will focus on new results that are revealing the dynamics and waveforms of binary black hole mergers, recoil velocities, and the possibility of accompanying electromagnetic outbursts.

Centrella, Joan↗

The Final Merger of Massive Black Holes: Recoils, Gravitational Waves, and Electromagnetic Signatures

The final merger of two massive black holes produces a powerful burst of gravitational radiation, emitting more energy than all the stars in the observable universe combined. The resulting gravitational waveforms will be easily detectable by the space-based LISA out to redshifts z greater than 10, revealing the masses and spins of the black holes to high precision. If the merging black holes have unequal masses, or asymmetric spins, the final black hole that forms can recoil with a velocity exceeding 1000 km/s. And, when the black holes merge in the presence of gas and magnetic fields, various types of electromagnetic signals may also be produced. For more than 30 years, scientists have tried to compute black hole mergers using the methods of numerical relativity. The resulting computer codes have been plagued by instabilities, causing them to crash well before the black holes in the binary could complete even a single orbit. Within the past few years, however, this situation has changed dramatically, with a series of remarkable breakthroughs. This talk will focus on new results that are revealing the dynamics and waveforms of binary black hole mergers, recoil velocities, and the possibility of accompanying electromagnetic outbursts.

Centrella, Joan M.↗

Nuclear Microprobe using Elastic Recoil Detection (ERD) for Hydrogen Profiling in High Temperature Protonic Conductors

The interaction between hydrogen and various high temperature protonic conductors (HTPC) has not been clearly understood due to poor densification and unreacted secondary phases. the melt-processing technique is used in producing fully dense simple SrCe(0.9)Y (0.10) O(3-delta) and complex Sr3Ca(1+x)Nb(2+x)O(9-delta) perovskites that can not be achieved by solid-state sintering. the possibilities of ion beam analysis have been investigated to quantify hydrogen distribution in HTPC perovskites subjected to water heat treatment. Nuclear microprobe technique is based on the interactions of a focused ion beam of MeV light ions (H-1, H-2, He-3, He-4,.) with the sample to be analyzed to determine local elemental concentrations at the cubic micrometer scale, the elastic recoil detection analysis technique (ERDA) has been carried out using He-4(+) microbeams and detecting the resulting recoil protons. Mappings of longitudinal sections of water treated SrCeO3 and Sr(Ca(1/3)Nb(2/3))O3 perovskites have been achieved, the water treatment strongly alters the surface of simple SrCe(0.9)Y(0.10)O(3-delta) perovskite. From Rutherford Back Scattering measurements (RBS), both Ce depletion and surface re-deposition is evidenced. the ERDA investigations on water treated Sr3Ca(1+x)Nb(2+x)O(9-delta) perovskite did not exhibit any spatial difference for the hydrogen incorporation from the surface to the centre. the amount of hydrogen incorporation for Sr3Ca(1+x)Nb(2+x)O(9-delta) was low and required further development of two less conventional techniques, ERDA in forward geometry and forward elastic diffusion H-1(p,p) H-1 with coincidence detection.

Berger, Pascal↗