Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RAYLEIGH SCATTERING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Scattering in the atmosphere of Venus. III - Line profiles and phase curves for Rayleigh scattering

Spectral line profiles, curves of growth, and curves for the equivalent width of a line as a function of Venus phase angle have been computed for a Rayleigh scattering cloud and compared with those for a cloud of isotropic scatterers. The results are very similar for the two kinds of scattering, with the exception of the curves of equivalent width as a function of Venus phase angle. These latter curves exhibit the 'inverse phase effect' and rule out a scale height of the clouds much less than half the scale height of the gas. The optical depth of the clouds is approximately 100.

Young, L. D. G.↗

Development of a Rayleigh scattering system for temperature measurements in combustor flows

A dual line laser induced Rayleigh scattering system has been developed to be used in high temperature gas flows such as in combustors, and preliminary tests have been performed in a hot air jet. The qualification measurements included the collection and analysis of Rayleigh signal for time-resolved gas temperature over the two lines of a copper-vapor laser. The dual line signal collection technique is a feature to be used in detecting and discriminating the surface scattered laser light in the Rayleigh signal. Optical fibers are used to transmit the laser beam to the optical probe bench and to carry the collected signal from the bench to the housing of the signal sensors. Incident laser intensity at the probe volume is measured for both lines at each pulse of the laser. This information is used to normalize the signal. Good agreement has been obtained between the two line Rayleigh scattering and thermocouple results in the particle free co-flowing air jet.

Otugen, M. V.↗

100-kHz Interferometric Rayleigh Scattering Flow Diagnostics at 266 nm

Interferometric Rayleigh scattering (IRS) is a laser-based technique capable of spatially and temporally resolved measurement of gas velocity and temperature in unseeded gaseous flows. In the present embodiment of the technique, IRS is performed at 266 nm for the first time. IRS at 266 nm is potentially much less susceptible to interferences from particles and other stray light sources. A pulse-burst laser and high-speed camera provided image rates of 100 kHz, allowing simultaneous space- and time-resolved measurement in high speed flow at multiple points along a line. The use of 266 nm excitation and detection is compared with prior work that used 532 nm. New experimental interferogram modelling and fitting techniques for single and multi-velocity-component IRS were demonstrated in a study of the spatial and temporal variation of the flow along a line through a supersonic jet. Single component velocity and temperature measurements using 266 nm were successfully made and compared with prior 532 nm results. Two-component velocity measurements at 266 nm, using the reflected image method, were compared to single-component measurements.

Andrew D Cutler↗

Multi-Point Interferometric Rayleigh Scattering using Dual-Pass Light Recirculation

This paper describes for the first time an interferometric Rayleigh scattering system using dual-pass light recirculation (IRS-LR) capable of simultaneously measuring at multiple points two orthogonal components of flow velocity in combustion flows using single shot laser probing. An additional optical path containing the interferometer input mirror, a quarter-wave plate, a polarization dependent beam combiner, and a high reflectivity mirror partially recirculates the light that is rejected by the interferometer. Temporally- and spatially-resolved acquisitions of Rayleigh spectra in a large-scale combustion-heated supersonic axi-symmetric jet were performed to demonstrate the technique. Recirculating of Rayleigh scattered light increases the number of photons analyzed by the system up to a factor of 1.8 compared with previous configurations. This is equivalent to performing measurements with less laser energy or performing measurements with the previous system in gas flows at higher temperatures.

Bivolaru, Daniel↗

Rayleigh Scattering Diagnostic for Simultaneous Measurements of Dynamic Density and Velocity

A flow diagnostic technique based on the molecular Rayleigh scattering of laser light is used to obtain dynamic density and velocity data in turbulent flows. The technique is based on analyzing the Rayleigh scattered light with a Fabry-Perot interferometer and recording information about the interference pattern with a multiple anode photomultiplier tube (PMT). An artificial neural network is used to process the signals from the PMT to recover the velocity time history, which is then used to calculate the velocity power spectrum. The technique is illustrated using simulated data. The results of an experiment to measure the velocity power spectrum in a low speed (100 rn/sec) flow are also presented.

Seasholtz, Richard G.↗

Demonstration of Frequency-Scanning Burst-mode Filtered Rayleigh Scattering for Multi-Parameter Gas-Phase Measurements

Filtered Rayleigh scattering (FRS) is a diagnostic technique used for measurements of macroscopic properties of a gas. The FRS signal is passed through a narrow bandwidth molecular filter, commonly gaseous iodine, to measure the broadening and Doppler-shift of the scattering light from the molecules of the gas flow. However, in single-frequency, intensity-based approaches, the effects of pressure, temperature, and velocity can be difficult to deconvolve. To overcome this challenge, frequency-scanning FRS has been used to quasi-spectrally resolve the signal. In this work, a frequency-scanned, burst-mode laser was used to perform scanning FRS in an underexpanded jet to measure temperature, pressure, and radial velocity at measurement rates up to 1 kHz which is ~100,000 times faster than prior implementations of scanning FRS.

filtered Rayleigh scattering↗

Effect of Electronic Shot Noise on Dynamic Measurements using Optical Techniques: Examples from Rayleigh Scattering and Unsteady PSP

Electronic shot noise is an unavoidable reality in all optical techniques that depend on measuring light intensity. For steady-state, time-averaged measurements the impact of shot noise can be easily reduced by increasing the exposure time, or by averaging over multiple-exposures. That is not the case for unsteady measurements, where time histories of light intensity variations need to be created either by high-speed photography (unsteady PSP) or via photoelectron counting (spectrally resolved Rayleigh scattering) over short time durations using a photo-multiplier tube (PMT) and photon counting electronics. Electronic shot noise introduces a fixed amount of random error, which can overwhelm the light intensity variation caused by turbulent fluctuations. Spectrum computed from such time series shows a fixed noise floor that is independent of the number of data points in the time series. For a fixed optical system, where the collected power of the luminescent light (uPSP), or the scattered light (Rayleigh) is fixed, one needs to resort to special techniques to obtain enough signal-to noise ratio (SNR). For the uPSP application it is shown that averaging of the adjacent pixels improves SNR; although this may lead to a sacrifice of spatial resolution. A second means is to increase the exposure time, which leads to a lowering of the frequency range. For the Rayleigh application, improvements of SNR can be achieved via two different cross-correlation based approaches. The first involves measuring the light intensity using two PMTs using short, contiguous gates; thereby, creating two time-series of data. The second one involves collecting one long time-series of data using one set of measurement device, followed by an odd-even splitting into two time series. When the two time-series are cross-correlated, and a power spectrum is calculated, a significant reduction in the shot noise floor can be achieved. Examples from measurements of density and velocity fluctuations spectra from two different Rayleigh setup are presented to demonstrate the process.

uPSP↗

Progress in Interferometric Rayleigh Scattering to Measure Fluctuations Spectra of Velocity and Temperature in High Speed Flows

A new, spectrally-resolved, Rayleigh scattering setup at NASA Ames is further developed to measure fluctuations in velocity and temperature. Using a combination of a continuous-wave laser, a stabilized Fabry-Perot interferometer (FPI), an EMCCD camera, and a photo-multiplier tube, the setup was demonstrated to provide fairly accurate measurements of time-averaged velocity, temperature, density and spectrum of density fluctuations in a high-speed free jet (Panda & White, 2018). This paper describes further progress in fast measurement of the Rayleigh-Brillouin spectrum via a 16-anode linear-array of photo-multiplier tube and a multi-channel, photo-electron counter. Rayleigh scattered light from a 0.4mm long probe volume was directly imaged through the FPI and was imaged on the linear array. Synchronous photo-electron counting over a series of short, contiguous gates provided time-evolution of the fringes at a 10 kHz sampling rate. Sample spectra collected from a Mach 0.98 jet show spectral content floating on high noise-floor. Efforts to collect longer time series of data and different schemes of extracting velocity and temperature information are now in progress.

Panda, J.↗

Rayleigh Scattering Diagnostic for Dynamic Measurement of Velocity Fluctuations in High Speed Jets

A flow diagnostic technique based on the molecular Rayleigh scattering of laser light is used to obtain dynamic density and velocity data in a high speed flow. The technique is based on analyzing the Rayleigh scattered light with a Fabry-Perot interferometer used in the static, imaging mode. An analysis is presented that established a lower bound for measurement uncertainty of about 20 m/sec for individual velocity measurements obtained in a 100 microsecond time interval. Software and hardware interfaces were developed to allow computer control of all aspects of the experiment and data acquisition. The signals from three photomultiplier tubes were simultaneously recorded using photon counting at a 10 kHz sampling rate and 10 second recording periods. Density and velocity data, including distribution functions and power spectra, taken in a Mach 0.8 free jet, are presented.

Seasholtz, Richard G.↗

Development of a Rayleigh Scattering Diagnostic for Time-Resolved Gas Flow Velocity, Temperature, and Density Measurements in Aerodynamic Test Facilities

A molecular Rayleigh scattering technique is developed to measure time-resolved gas velocity, temperature, and density in unseeded turbulent flows at sampling rates up to 32 kHz. A high power continuous-wave laser beam is focused at a point in an air flow field and Rayleigh scattered light is collected and fiber-optically transmitted to the spectral analysis and detection equipment. The spectrum of the light, which contains information about the temperature and velocity of the flow, is analyzed using a Fabry-Perot interferometer. Photomultiplier tubes operated in the photon counting mode allow high frequency sampling of the circular interference pattern to provide time-resolved flow property measurements. An acoustically driven nozzle flow is studied to validate velocity fluctuation measurements, and an asymmetric oscillating counterflow with unequal enthalpies is studied to validate the measurement of temperature fluctuations. Velocity fluctuations are compared with constant temperature anemometry measurements and temperature fluctuations are compared with constant current anemometry measurements at the same locations. Time-series and power spectra of the temperature and velocity measurements are presented. A numerical simulation of the light scattering and detection process was developed and compared with experimental data for future use as an experiment design tool.

Mielke, Amy F.↗

Absolute Rayleigh scattering cross sections of gases and freons of stratospheric interest in the visible and ultraviolet regions

The laboratory measurements of absolute Rayleigh scattering cross sections as a function wavelength are reported for gas molecules He, Ne, Ar, N2, H2, O2, CO2, CH4 and for vapors of most commonly used freons CCl2F2, CBrF3, CF4, and CHClf2. These cross sections are determined from the measurements of photon scattering at an angle of 54 deg 44 min which yield the absolute values independent of the value of normal depolarization ratios. The present results show that in the spectral range 6943-3638A deg, the values of the Rayleigh scattering cross section can be extrapolated from one wavelength to the other using 1/lambda (4) law without knowing the values of the polarizabilities. However, such an extrapolation can not be done in the region of shorter wavelengths.

SHARDANAND↗

Using Computational Flow Imaging to Optimize Filtered Rayleigh Scattering Measurements of an Isolator Shock Train

Filtered Rayleigh scattering (FRS) is a laser diagnostic where the intensity of elastically scattered light is measured after it passes through a molecular absorption filter. The filter removes background interference that overwhelms the relatively weak scattering from the gas molecules. However, with a filter, the measured light intensity depends on many of the scattering gas properties, including pressure, density, temperature, and velocity. In this work, CFD simulations of an isolator shock train flow field are input into a physics-based model to predict the values of FRS intensity measurements in a proposed experiment. The goal is to evaluate if a simplistic FRS setup (that utilizes one camera, laser, and absorption filter) can be used to accurately quantify number density despite the fact that the scattered light intensity also depends on other gas properties. It is found that the experimental setup can be optimized such that a linear relationship describes the number density with an average prediction error of 2%. The vast majority of the flow exhibits prediction errors of less than 3%, but small regions of the flow reach up to 11% error. A sensitivity analysis shows that the prediction error increases with the central wavelength of the incident laser light and decreases with the angle between the camera and laser propagation directions. The optimal experimental parameters are chosen based on a compromise between the prediction error, spatial resolution, and the amount of unfiltered light. In the future, the proposed FRS setup will be implemented to acquire new and valuable information on an isolator shock train, a flow field that has been traditionally studied using wall static pressure measurements and path-integrated visualization techniques, such as schlieren and shadowgraphy.

Hunt, Robin L.↗

Rayleigh scattering measurements in supersonic facilities

Using a narrow-band, pulsed, ArF excimer laser and a single-intensified CCD camera, planar laser Rayleigh scattering measurements were performed to obtain quantitative density measurements both in the free stream and in a model flow field. These measurements were conducted in the 15-inch, Mach 6 high temperature facility at NASA Langley Research Center. This facility is capable of achieving stagnation temperatures up to 700 K (800 F) over a range of stagnation pressures from 0.35 to 2.07 MPa (50 to 300 psia). The high temperature capability of this facility eliminates the clustering effect observed in earlier Mach 6 studies, and allows quantitative density measurements in the free stream over a range of stagnation pressures from 0.35 to 1.75 MPa (50 to 250 psia). Model flow field measurements were obtained on 38.1 mm diameter cylinder. Measurement locations include the free stream, the region behind the bow shock in front of the model, and the region behind the model including the wake. The densities deduced from the Rayleigh scattering measurements in the model flow field are compared with CFD computations. Measurement uncertainties and the detection limit are discussed.

Shirinzadeh, B.↗

Velocity and Temperature Measurement in Supersonic Free Jets Using Spectrally Resolved Rayleigh Scattering

The flow fields of unheated, supersonic free jets from convergent and convergent-divergent nozzles operating at M = 0.99, 1.4, and 1.6 were measured using spectrally resolved Rayleigh scattering technique. The axial component of velocity and temperature data as well as density data obtained from a previous experiment are presented in a systematic way with the goal of producing a database useful for validating computational fluid dynamics codes. The Rayleigh scattering process from air molecules provides a fundamental means of measuring flow properties in a non-intrusive, particle free manner. In the spectrally resolved application, laser light scattered by the air molecules is collected and analyzed using a Fabry-Perot interferometer (FPI). The difference between the incident laser frequency and the peak of the Rayleigh spectrum provides a measure of gas velocity. The temperature is measured from the spectral broadening caused by the random thermal motion and density is measured from the total light intensity. The present point measurement technique uses a CW laser, a scanning FPI and photon counting electronics. The 1 mm long probe volume is moved from point to point to survey the flow fields. Additional arrangements were made to remove particles from the main as well as the entrained flow and to isolate FPI from the high sound and vibration levels produced by the supersonic jets. In general, velocity is measured within +/- 10 m/s accuracy and temperature within +/- 10 K accuracy.

Panda, J.↗

Advancements in Burst-Mode Filtered Rayleigh Scattering for High-Speed Gas-Phase Multi-Parameter Measurements

Filtered Rayleigh scattering (FRS) can be used for velocity, density, temperature, and/or pressure measurements over a wide range of non-reacting flow conditions as well as more limited reacting flow conditions. However, the application of FRS to gas-phase measurements in large-scale test facilities can be limited due to low signal levels, strong background interferences, or the requirement for multiple cameras and/or molecular filters to spectrally resolve the signal. This work focuses on the spectral characteristics and wavelength-agility of burst-mode lasers for use in FRS systems. These advancements could improve measurement capability and data quality in applications with high levels of stray background scattering as well as where increased temporal resolution is desirable, such as high-speed flows.

filtered Rayleigh scattering↗

Direct-View Multi-Point Two-Component Interferometric Rayleigh Scattering Velocimeter

This paper describes an instantaneous velocity measurement system based on the Doppler shift of elastically scattered laser light from gas molecules (Rayleigh scattering) relative to an incident laser. The system uses a pulsed laser as the light source, direct-viewing optics to collect the scattered light, an interferometer to analyze spectrally the scattered light mixed with the incident laser light, and a CCD camera to capture the resulting interferogram. The system is capable of simultaneous, spatially (approximately 0.2 mm(exp 3)) and temporally (approximately 40 ns) resolved, multiple point measurements of two orthogonal components of flow velocity in the presence of background scattered light, acoustic noise and vibrations, and flow particulates. Measurements in a large-scale axi-symmetric Mach 1.6 H2-air combustion-heated jet running at a flow sensible enthalpy specific to Mach 5.5 hypersonic flight are performed to demonstrate the technique. The measurements are compared with CFD calculations using a finite-volume discretization of the Favre-averaged Navier-Stokes equations (VULCAN code).

Bivolaru, Daniel↗

The Mariner 5 ultraviolet photometer experiment - Analysis of Rayleigh-scattered and 1304-A radiation from Venus

Airglow measurements of the disk of Venus, made by the ultraviolet photometer on Mariner 5 on October 19, 1967, are analyzed to determine the sources of the observed emission. Rayleigh-scattering models for a semi-infinite atmosphere are used to determine the scale height and single-scattering albedo of the scatterer and to determine the 1304-A emission rate. It is found that (1) the scale height of the Rayleigh-scattered radiation is about 4.5 km, (2) the single-scattering albedo near 2000 A is about 0.8, and (3) 500 R of 1304-A radiation is detected at solar zenith angles between 90 and 95 deg.

Anderson, D. E., Jr.↗

Volumetric imaging of supersonic boundary layers using filtered Rayleigh scattering background suppression

We demonstrate the use of Filtererd Rayleigh Scattering and a 3D reconstruction technique to interrogate the highly three dimensional flow field inside of a supersonic inlet model. A 3 inch by 3 inch by 2.5 inch volume is reconstructed yielding 3D visualizations of the crossing shock waves and of the boundary layer. In this paper we discuss the details of the techniques used, and present the reconstructured 3D images.

Forkey, Joseph N.↗