Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RAMAN SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Surface-Enhanced Raman Spectroscopy (SERS) for Venus Atmospheric Characterization and Trace Organics Identification

The chemical composition of Venus’ clouds has attracted considerable attention since the first atmospheric probes entered the planet in the early 1980s. We know from these early studies that cloud aerosols consist of micron and submicron droplets of sulfuric acid (~85%) and water (~15%), but outstanding questions still exist regarding their trace chemical composition, especially the identity of the unknown UV absorber(s) and the possible presence of organic material (Spacek & Benner, 2021). Veritas and DaVinci will launch at the end of the decade to advance our understanding of Venus’ surface and atmosphere, however these missions are not designed to sample and analyze cloud aerosols at trace levels. Raman spectroscopy is an ideal candidate for characterizing aerosols and has a track record in studies of Earth’s atmosphere. Raman provides broad chemical screening of organic and inorganic molecules within seconds, and Raman instrumentation can be miniaturized to meet the stringent size, weight, and power (SWaP) constraints of an atmospheric probe while retaining sensitivity and specificity that allow spectral fingerprinting of compounds and functional groups. Raman alone is insufficient to characterize trace constituents however, as limits of detection are typically in the 10s to 100s of ppm at best for planetary Raman spectrometers. Surface-Enhanced Raman Spectroscopy (SERS), a method that utilizes nanoscale materials interacting with a sample to enhance weak Raman signals by orders of magnitude when probed by a laser, has the potential to drastically improve the sensitivity of a Raman instrument while adding little-to-no SWaP nor complexity to a scientific payload. We aim to de-risk SERS technology for rapid infusion in future planetary science missions by developing custom SERS substrates tailored towards Venus atmospheric exploration. We have developed SERS substrates consisting of nanotextured silver films and tested them on potential Venus-relevant organic compounds, with preliminary results indicating sub-ppm sensitivity. Additionally, we have planned tests to investigate durability, longevity, and other key characteristics that impact SERS substrate performance to prepare SERS technology for flight.

Venus↗

Measuring molecular flows with high-resolution stimulated Raman spectroscopy

It is proposed to use high-resolution stimulated Raman spectroscopy to directly measure high-speed molecular flow velocities in wind tunnels and in combustive chambers. A feasibility study indicates that flow speeds from Mach 0.04 up may be measured with the proposed method using available laser systems. It is pointed out that the success of the proposed technique will make it possible to measure all interesting flow parameters, i.e., species concentration, temperature, and velocity, in a time of less than 1 microsecond at a repetition rate of 10,000/s using a single experimental arrangement.

She, C. Y.↗

Investigations of coherent anti-Stokes Raman spectroscopy /CARS/ for practical combustion diagnostics

Coherent anti-Stokes Raman spectroscopy (CARS) is a coherent wave-mixing process in which the signal emerges as a laser-like beam in a precise direction. The spectroscopic technique is appropriate to spatially and temporally resolved measurements of temperature and major species concentrations in combustion. It has been generated from all of the dominant constituents in air-fed, hydrogen, and hydrocarbon fueled combustion, and found applicable to practical combustion systems. High pressure effects on CARS spectra have also been examined.

Eckbreth, A. C.↗

Diagnostics of silane and germane radio frequency plasmas by coherent anti-Stokes Raman spectroscopy

In situ plasma diagnostics using coherent anti-Stokes Raman spectroscopy have shown different dissociation characteristics for GeH4 and SiH4 in radio frequency (rf) plasma-enhanced chemical vapor deposition of amorphous silicon germanium alloy (a-SiGe:H) thin films. The GeH4 dissociation rate in rf plasmas is a factor of about 3 larger than that of SiH4. Plasma diagnostics have revealed that the hydrogen dilution of the SiH4 and GeH4 mixed plasma plays a critical role in suppressing the gas phase polymerization and enhancing the GeH4 dissociation.

Perry, Joseph W.↗

The Local Electronic Structure of Supercritical CO 2 from X-ray Raman Spectroscopy and Atomistic-Scale Modeling

Supercritical CO 2 is encountered in several technical and natural systems related to biology, geophysics, and engineering. While the structure of gaseous CO 2 has been studied extensively, the properties of supercritical CO 2 , particularly close to the critical point, are not well-known. Here, in this work, we combine X-ray Raman spectroscopy, molecular dynamics simulations, and first-principles density functional theory (DFT) calculations to characterize the local electronic structure of supercritical CO 2 at conditions around the critical point. The X-ray Raman oxygen K-edge spectra manifest systematic trends associated with the phase change of CO 2 and the intermolecular distance. Extensive first-principles DFT calculations rationalize these observations on the basis of the 4sσ Rydberg state hybridization. X-ray Raman spectroscopy is found to be a sensitive tool for characterizing electronic properties of CO 2 under challenging experimental conditions and is demonstrated to be a unique probe for studying the electronic structure of supercritical fluids.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a Nuclear Fuel Dissolution Monitor Based on Raman Spectroscopy

The processing of spent nuclear fuel and other nuclear materials is a critical component of nuclear material management with implications for global security. The first step of fuel processing is dissolution, with several charges of fuel sequentially added to a batch of solvent. The incomplete dissolution of a charge precludes the addition of the next charge. As the dissolution takes place in a heated, highly corrosive and radiological vessel, direct monitoring of the process is not possible. We discuss the use of Raman spectroscopy to indirectly monitor dissolution through an analysis of the gaseous emissions from the dissolver. Challenges associated with the implementation of Raman spectroscopy include the composition and physical characteristics of the offgas stream and the impact of operating conditions. Nonetheless, we observed that NO2 concentrations serve as a reliable indicator of process activity and correlate to the amount of fuel material that remains undissolved. These results demonstrate the promise of the method for monitoring nuclear material dissolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of PuO 2 With Visible and UV Raman Spectroscopy: Discrimination Between the Bulk, Surface, and an Intermediate Disordered Layer

Raman spectroscopy is an ideal tool in the characterization of materials including PuO 2 . The wavelength-dependent absorptivity of the material defines the light penetration depth and the relative Raman scattering contribution from the bulk and the surface. Here, the surface contribution to the total Raman scattering was investigated for PuO 2 calcined at various temperatures and recorded with laser wavelengths of 355, 325, and 244 nm. These experiments provided the first glimpse of the wavelength-dependent disappearance and emergence of new phonons and electronic bands from the PuO 2 surface layers. The first indication of the wavelength transition in the Raman spectra was the loss of the 2LO2 (overtone, ~1155 cm -1 ) band and the weakening intensity of the Г 1 → Γ 5 electronic band (~2135 cm -1 ) with the 355-nm excitation laser. The Γ 5 electronic band was barely visible with the 244-nm excitation. The electronic band located at ~1050 cm -1 , corresponding to the Г 1 → Γ 4 electronic transition was observed to dramatically increase in intensity while the Г 1 → Γ 3 electronic band (2640 cm -1 ) sharpened as the UV wavelength was increased in energy from the near- to deep-UV (355–325–244 nm). The FWHM of the T 2g band was found to vary with calcination temperature (450°C and 900°C) with the 325-nm laser and the 244-nm laser. The T 2g band attributes, the strong emergence of the Г 1 → Γ 4 electronic band, and the disappearance of the 2LO2 overtone acquired with the 244-nm excitation for the different calcination temperatures suggest a shallow penetration depth.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On-line Measurement of Hydrogen Gas using Raman Spectroscopy for Process Gas Systems

Advanced reprocessing schemes such as the Zircex process are important for continued development of the nuclear fuel cycle. The hydrochlorination reaction of the Zircex process flow sheet for metallic fuels has a known off-gas stream of H 2 (g) and HCl. The flow sheet can be simplified through HCl recycling, which requires detection and quantification of any residual H 2 (g) for safety and purity. In this work, commercially available Raman spectroscopy was applied for low-level, on-line detection of H 2 (g) in process gas streams, and parameters were adjusted to optimize the H 2 (g) Raman signal. Increasing the number of scans and exposure time in the spectrometer increased the signal-to-noise ratio of the H 2 (g) Raman signal, while the gas flow rate was optimized at 2.3 L/min. The limit of detection for H 2 (g) was estimated to be 2,100 ppm H 2 (g) in an N 2 (g) background. This scoping study for the application of Raman spectroscopy for on-line measurements of H 2 (g) shows that H 2 (g) can be detected at low levels (approximately 5% of the lower explosive limit (LEL)) in flowing gas streams.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Polarized tip-enhanced Raman spectroscopy at liquid He temperature in ultrahigh vacuum using an off-axis parabolic mirror

Tip-enhanced Raman spectroscopy (TERS) combines inelastic light scattering well below the diffraction limit down to the nanometer range and scanning probe microscopy and, possibly, spectroscopy. In this way, topographic and spectroscopic as well as single- and two-particle information may simultaneously be collected. While single molecules can now be studied successfully, bulk solids are still not meaningfully accessible. It is the purpose of the work presented here to outline approaches toward this objective. We describe a home-built, liquid helium cooled, ultrahigh vacuum TERS. The setup is based on a scanning tunneling microscope and, as an innovation, an off-axis parabolic mirror having a high numerical aperture of ~0.85 and a large working distance. The system is equipped with a fast load-lock chamber, a chamber for the in situ preparation of tips, substrates, and samples, and a TERS chamber. Base pressure and temperature in the TERS chamber were ~3 × 10 –11 mbar and 15 K, respectively. Polarization dependent tip-enhanced Raman spectra of the vibration modes of carbon nanotubes were successfully acquired at cryogenic temperature. The new features described here including very low pressure and temperature and the external access to the light polarizations, thus the selection rules, may pave the way toward the investigation of bulk and surface materials.

47 OTHER INSTRUMENTATION↗

The crystal orientation of THF clathrates in nano-confinement by in situ polarized Raman spectroscopy

Gas hydrates form at high pressure and low temperatures in marine sediments and permafrost regions of the earth. Despite forming in nanoporous structures, gas hydrates have been extensively studied only in bulk. Understanding nucleation and growth of gas hydrates in nonporous confinement can help create ways for storage and utilization as a future energy source. Herein, we introduce a new method for studying crystal orientation/tilt during tetrahydrofuran (THF) hydrate crystallization under the influence of nano-confinement using polarized Raman spectroscopy. Uniform cylindrical nanometer size pores of anodic aluminum oxide (AAO) are used as a model nano-confinement, and hydrate experiments are performed in a glass microsystem for control of the flash hydrate nucleation kinetics and analysis via in situ polarized Raman spectroscopy. The average THF hydrate crystal tilt of 56 ± 1° and 30.5 ± 0.5° were observed for the 20 nm and 40 nm diameter pores, respectively. Crystal tilt observed in 20 and 40-nanometer-size pores was proportional to the pore diameter, resulting in lower tilt relative to the axis of the confinement at larger diameter pores. Finally, the results indicate that the hydrates nucleation and growth mechanism can depend on the nanoconfinement size. A 1.6 ± 0.01 °C to 1.8 ± 0.01 °C depression in melting point compared to the bulk is predicted using the Gibbs–Thomson equation as a direct effect of nucleation in confinement on the hydrate properties.

25 ENERGY STORAGE↗

Raman spectroscopy of neutron irradiated silicon carbide

The effects of neutron irradiation on microstructural evolution and the resultant changes in physical and mechanical properties are of critical importance for the development of silicon carbide (SiC) materials for nuclear applications. This study neutron-irradiated βSiC under a wide range of conditions at temperatures between 235 and 750°C and neutron doses of 0.01–11.8 displacements per atom, and then evaluated the effects on the SiC structure using Raman spectroscopy. The SiC optical phonon lines were shifted to lower wavenumbers by irradiation. Correlations were found among the wavenumber of the longitudinal optical phonon line, irradiation-induced swelling, and irradiation temperature. The peak shift also correlated indirectly with decreasing thermal conductivity of irradiated SiC. The irradiation-induced peak shift is explained by combinations of lattice strain, reduction of the elastic modulus, and other factors including decreasing coherent domain size. These findings bridge irradiation-induced microstructural changes and property changes and illustrate how Raman spectroscopy is a useful tool for nondestructively assessing irradiated SiC materials for nuclear applications.

Koyanagi, T.↗

Investigating Surface Mineralogy, Alteration Processes, and Biomarkers on Mars Using Laser Raman Spectroscopy

Despite a wealth of information from past and ongoing missions to Mars, the capability to determine the mineralogy of surface materials and to connect mineralogy with lithologic characteristics that are diagnostic of the environment in which those materials formed remains inadequate. The 2003 Mars Exploration Rovers (MER) will carry a Mini-TES and a Mossbauer spectrometer, which will provide some detailed mineralogy information. For general characterization of minerals and/or biogenic phases (reduced carbon, PAHs, etc) on the surface of Mars, we have been developing a miniaturized laser Raman spectrometer for in situ analyses -- the Mars Microbeam Raman Spectrometer, MMRS. We are also developing strategies to use Raman spectroscopy as a stand-alone technique and to be used synergistically with other in situ analysis methods in future planetary missions. Through studies of Martian meteorites and terrestrial analogs, we are gaining experience of what compositional and structural information can be obtained on key mineral groups using in-situ Raman measurements. We are developing methods for determining mineral proportions in rocks or soils and identifying rock types from sets of closely spaced, rapidly acquired spectra. We are studying how weathering and alteration affect the Raman and luminescence features of minerals and rocks, and we are investigating the Raman characteristics of biogenic organisms and their remains. These studies form the scientific basis for in-situ planetary Raman spectroscopy, and they are being done in parallel with instrument development towards a flight version of the MMRS.

Alian Wang↗

Stochastic equilibrium Raman spectroscopy (STERS)

In this manuscript, we propose a new method for cavity- and surface-enhanced Raman spectroscopy (SERS) with improved temporal resolution in the measurement of stochastic Raman spectral fluctuations. Our approach combines Fourier spectroscopy and photon correlation to decouple the integration time from the temporal resolution. Using statistical optics Monte Carlo simulations, we establish the relationship between time resolution and Raman signal strength, revealing that typical Raman spectral fluctuations, commensurate with molecular conformational dynamics, can theoretically be resolved on micro- to millisecond timescales. The method can further extract average single-molecule dynamics from small sub-ensembles, thereby potentially mitigating challenges in achieving strictly single-molecule isolation on SERS substrates.

Cobb-Bruno, Colburn [University of California, Ber↗

Morphologically-Directed Raman Spectroscopy as an Analytical Method for Subvisible Particle Characterization in Therapeutic Protein Product Quality

Abstract Subvisible particles (SVPs) are a critical quality attribute of injectable therapeutic proteins (TPs) that needs to be controlled due to potential risks associated with drug product quality. The current compendial methods routinely used to analyze SVPs for lot release provide information on particle size and count. However, chemical identification of individual particles is also important to address root-cause analysis. Herein, we introduce Morphologically-Directed Raman Spectroscopy (MDRS) for SVP characterization of TPs. The following particles were used for method development: (1) polystyrene microspheres, a traditional standard used in industry; (2) photolithographic (SU-8); and (3) ethylene tetrafluoroethylene (ETFE) particles, candidate reference materials developed by NIST. In our study, MDRS rendered high-resolution images for the ETFE particles (> 90%) ranging from 19 to 100 μm in size, covering most of SVP range, and generated comparable morphology data to flow imaging microscopy. Our method was applied to characterize particles formed in stressed TPs and was able to chemically identify individual particles using Raman spectroscopy. MDRS was able to compare morphology and transparency properties of proteinaceous particles with reference materials. The data suggests MDRS may complement the current TPs SVP analysis system and product quality characterization workflow throughout development and commercial lifecycle.

Science & Technology - Other Topics↗

CO2 hydrate crystal thickening, morphology, and Raman spectroscopy in a microfluidic device

Gas hydrates are a solid, crystalline form of water that often form at low temperatures and high pressures. Carbon dioxide (CO2) hydrates may form during carbon dioxide capture and storage (CCS) processes. These solid compounds may form in CO2 pipelines, potentially leading to a full blockage and process shutdown for plug removal. On the other hand, formation of CO2 hydrates may be desired for CO2 capture and separation. In either case, understanding the growth behavior and nature of the hydrates is vital to managing these CCS processes. Using a high-pressure, transparent microfluidic reactor, the crystalline film thickening of CO2 hydrates was observed and measured through visual microscopy and Raman spectroscopy. The impact of subcooling, pressure, and CO2 flow rate was investigated, and only CO2 flow rate was found to have a significant impact on the overall thickness of the film. Visual observations and Raman spectroscopy measurements confirmed that two distinct hydrate layers formed during thickening, one which was more porous than the other. The capillary-like channels in the porous layer indicated a mechanism for mass transfer of water through the hydrate layer. A model was developed based on this observation, and it was fit to the thickening data in order to obtain mass transfer coefficients. Results of this study can be applied to CO2 hydrate formation in pipelines and near porous media used for CO2 capture.

Wadsworth, Lindsey [Colorado School of Mines, Gold↗

Investigations of coherent anti-Stokes Raman spectroscopy /CARS/ for combustion diagnostics

Investigations of coherent anti-Stokes Raman spectroscopy (CARS) in a variety of flames are presented. Thermometry has received the primary emphasis in these studies, but species spectral and sensitivity studies will also be described. CARS is generated by mixing a 10 pps, frequency-doubled neodymium 'pump' laser with a spectrally broadband, laser-pumped, Stokes-shifted dye laser. This approach obviates the requirement to frequency scan the dye laser and generates the entire CARS spectrum with each pulse permitting, in principle, instantaneous measurements of medium properties. CARS spectra of N2, CO, O2, H2O, CO2 and CH4 in flames will be presented. In general these spectra exhibit very good agreement with computer synthesized spectra and permit measurements of temperature and species concentration. To illustrate the applicability of CARS to practical combustion diagnostics, CARS signatures from N2 have been employed to map the temperature field throughout a small, luminous, highly sooting propane diffusion flame

Eckbreth, A. C.↗

Measuring Hydroxylammonium, Nitrate, and Nitrite Concentration with Raman Spectroscopy for 238 Pu Supply Program

Optical spectroscopy has great potential to improve the timeliness of important analytical measurements for the 238 Pu Supply Program by enabling real-time analysis of process solutions within radiochemical hot cells. Hydroxylammonium (H 3 NOH + ]), nitrate (NO 3 - ), and nitrite (NO 2 - ) are three important molecular species present in multiple aqueous streams throughout the program’s flow sheet. The concentration of each species normally goes uncharacterized during processing. However, rapid quantification may benefit the program because uncertainties in kinetic redox expressions describing hydroxylammonium (HA) and nitrite reactions with Np and Pu leads to uncertainty in process model predictions for solvent extraction runs. HA concentration is normally quantified using ion chromatography, a technique that requires diluted grab samples taken out of the hot cell and analyzed off-line. Here we evaluate Raman spectroscopy for determining the concentration of H 3 NOH + , NO 3 - , and NO 2 - in benchtop tests to determine limits of detection. We also consider the possibility of using Raman spectroscopy in both glove box and hot cell environments for rapid analysis and pinpoint additional development opportunities needed to make this application successful.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗