Radiobiology for eye plaque brachytherapy and evaluation of implant duration and radionuclide choice using an objective function

Purpose: Clinical optimization of Collaborative Ocular Melanoma Study (COMS) eye plaque brachytherapy is currently limited to tumor coverage, consensus prescription dosage, and dose calculations to ocular structures. The biologically effective dose (BED) of temporary brachytherapy treatments is a function of both chosen radionuclide R and implant duration T. This study endeavored to evaluate BED delivered to the tumor volume and surrounding ocular structures as a function of plaque position P, prescription dose, R, and T. Methods: Plaque-heterogeneity-corrected dose distributions were generated with MCNP5 for the range of currently available COMS plaques loaded with sources using three available low-energy radionuclides. These physical dose distributions were imported into the PINNACLE{sup 3} treatment planning system using the TG-43 hybrid technique and used to generate dose volume histograms for a T = 7 day implant within a reference eye geometry including the ciliary body, cornea, eyelid, foveola, lacrimal gland, lens, optic disc, optic nerve, retina, and tumor at eight standard treatment positions. The equation of Dale and Jones was employed to create biologically effective dose volume histograms (BEDVHs), allowing for BED volumetric analysis of all ROIs. Isobiologically effective prescription doses were calculated for T = 5 days down to 0.01 days, with BEDVHs subsequently generated for all ROIs using correspondingly reduced prescription doses. Objective functions were created to evaluate the BEDVHs as a function of R and T. These objective functions are mathematically accessible and sufficiently general to be applied to temporary or permanent brachytherapy implants for a variety of disease sites. Results: Reducing T from 7 to 0.01 days for a 10 mm plaque produced an average BED benefit of 26%, 20%, and 17% for {sup 103}Pd, {sup 125}I, and {sup 131}Cs, respectively, for all P; 16 and 22 mm plaque results were more position-dependent. {sup 103}Pd produced a 16%-35% BED benefit over {sup 125}I, whereas {sup 131}Cs produced a 3%-7% BED detriment, independent of P, T, and plaque size. Additionally, corresponding organ at risk physical doses were lowest using {sup 103}Pd in all circumstances. Conclusions: The results suggest that shorter implant durations may correlate with more favorable outcomes compared to 7 day implants when treating small or medium intraocular lesions. The data also indicate that implant duration may be safely reduced if the prescription physical dose is likewise diminished and that {sup 103}Pd offers a substantial radiobiological benefit over {sup 125}I and {sup 131}Cs irrespective of plaque position, implant duration, and tumor size.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-385: 4D Radiobiology

Purpose: The linear-quadratic model is the most prevalent model for planning dose fractionation in radiation therapy in the low dose per fraction regimens. However for high-dose fractions, used in SRS/SBRT/HDR treatments the LQ model does not yield accurate predictions, due to neglecting the reduction in the number of sublethal lesions as a result of their conversion to lethal lesions with subsequent irradiation. Proper accounting for this reduction in the number of sublethally damaged lesions leads to the dependence of the survival fraction on the temporal structure of the dose. The main objective of this work is to show that the functional dependence of the dose rate on time in each voxel is an important additional factor that can significantly influence the TCP. Methods: Two SBRT lung plans have been used to calculate the TCPs for the same patient. One plan is a 3D conformal plan and the other is an IMRT plan. Both plans are normalized so that 99.5% of PTV volume receives the same prescription dose of 50 Gy in 5 fractions. The dose rate in each individual voxel is calculated as a function of treatment time and subsequently used in the calculation of TCP. Results: The calculated TCPs show that shorter delivery times lead to greater TCP, despite all delivery times being short compared to the repair half-time for sublethal lesions. Furthermore, calculated TCP(IMRT) =0.308 for the IMRT plan is smaller than TCP(3D) =0.425 for 3D conformal, even though it shows greater tumor hot spots and equal PTV coverage. The calculated TCPs are considerably lower compared to those based on the LQ model for which TCP=1 for both plans. Conclusion: The functional dependence of the voxel-by-voxel dose rate on time may be an important factor in predicting the treatment outcome and cannot be neglected in radiobiological modeling.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP3-02: Determination of Geometry-Specific Backscatter Factors for Radiobiology Studies

Purpose: Radiation biology research relies on an accurate radiation dose delivered to the biological target. Large field irradiations in a cabinet irradiator may use the AAPM TG-61 protocol. This relies on an air-kerma measurement and conversion to absorbed dose to water (Dw) on the surface of a water phantom using provided backscatter factors. Cell or small animal studies differ significantly from this reference geometry. This study aims to determine the impact of the lack of full scatter conditions in four representative geometries that may be used in radiobiology studies. Methods: MCNP6 was used to model the Dw on the surface of a full scatter phantom in a validated orthovoltage x-ray reference beam. Dw in a cylindrical mouse, 100 mm Petri dish, 6-well and 96-well cell culture dishes was simulated and compared to this full scatter geometry. A reference dose rate was measured using the TG-61 protocol in a cabinet irradiator. This nominal dose rate was used to irradiate TLDs in each phantom to a given dose. Doses were obtained based on TLDs calibrated in a NIST-traceable beam. Results: Compared to the full scattering conditions, the simulated dose to water in the representative geometries were found to be underestimated by 12-26%. The discrepancy was smallest with the cylindrical mouse geometry, which most closely approximates adequate lateral- and backscatter. TLDs irradiated in the mouse and petri dish phantoms using the TG-61 determined dose rate showed similarly lower values of Dw. When corrected for this discrepancy, they agreed with the predicted Dw within 5%. Conclusion: Using the TG-61 in-air protocol and given backscatter factors to determine a reference dose rate in a biological irradiator may not be appropriate given the difference in scattering conditions between irradiation and calibration. Without accounting for this, the dose rate is overestimated and is dependent on irradiation geometry.

60 APPLIED LIFE SCIENCES↗

A fast Monte Carlo cell-by-cell simulation for radiobiological effects in targeted radionuclide therapy using pre-calculated single-particle track standard DNA damage data

Introduction: We developed a new method that drastically speeds up radiobiological Monte Carlo radiation-track-structure (MC-RTS) calculations on a cell-by-cell basis. Methods: The technique is based on random sampling and superposition of single-particle track (SPT) standard DNA damage (SDD) files from a “pre-calculated” data library, constructed using the RTS code TOPAS-nBio, with “time stamps” manually added to incorporate dose-rate effects. This time-stamped SDD file can then be input into MEDRAS, a mechanistic kinetic model that calculates various radiation-induced biological endpoints, such as DNA double-strand breaks (DSBs), misrepairs and chromosomal aberrations, and cell death. As a benchmark validation of the approach, we calculated the predicted energy-dependent DSB yield and the ratio of direct-to-total DNA damage, both of which agreed with published in vitro experimental data. We subsequently applied the method to perform a superfast cell-by-cell simulation of an experimental in vitro system consisting of neuroendocrine tumor cells uniformly incubated with 177 Lu. Results and discussion: The results for residual DSBs, both at 24 and 48 h post-irradiation, are in line with the published literature values. Our work serves as a proof-of-concept demonstration of the feasibility of a cost-effective “in silico clonogenic cell survival assay” for the computational design and development of radiopharmaceuticals and novel radiotherapy treatments more generally.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A very thin havar film vacuum window for heavy ions to perform radiobiology studies at the BNL Tandem

Heavy ion beams from the BNL Tandem Van de Graaff accelerators will be made available for radiobiology studies on cell cultures. Beam energy losses need to be minimized both in the vacuum window and in the air in order to achieve the ranges required for the cells to be studied. This is particularly challenging for ions heavier than iron. The design is presented of a 0.4-inch diameter Havar film window that will satisfy these requirements. Films as thin as 80 microinches were successfully pressure tested. The final thickness to be used may be slightly larger to help in achieving pin hole free windows. We discuss design considerations and present pressure and vacuum test results as well as tests with heavy ion beams.

36 MATERIALS SCIENCE↗

Surgical wound fluids from patients treated with intraoperative radiotherapy induce radiobiological response in breast cancer cells

Breast cancer is the most common cancer occurring in women. The standard of breast cancer treatment is based on breast-conserving surgery with administration of adjuvant whole breast radiotherapy. Research shows that in-breast relapse is most likely to occur in the tumour bed, i.e. around the scar. Intraoperative radiotherapy (IORT), in which radiation is delivered to the tumour bed, reduces the risk of local recurrence not only through direct cell killing, but also through modification of local microenvironment. Additionally IORT modifies the composition and biological activity of surgical wound fluid. Since many researchers show that radiation damage is mediated through factors secreted to the environment by irradiated cells, we hypothesized that this radiation-induced bystander effect is partly responsible for the change observed in surgical wound fluids. We collected conditioned medium from irradiated breast cancer cells (CM) and surgical wound fluids from patients who underwent IORT (RT-WF) and from patients after breast-conserving surgery alone (WF). We incubated two breast cancer cell lines (MCF-7 and MDA-MB-468) with WF, RT-WF, CM or WF + CM and measured radiobiological response of cells. We measured the level of double-strand breaks, induction of apoptosis and the changes in expression of genes related to DNA damage repair. We observed that stimulation with RT-WF and with WF + CM-induced double-strand breaks and increased expression of DNA damage repair-related genes, which was not observed after stimulation with WF. These results suggest that IOERT induces secretion of bystander factors mediating the genotoxic effect of ionizing radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lessons to be learned from a contentious challenge to mainstream radiobiological science (the linear no-threshold theory of genetic mutations)

There are both statistically valid and invalid reasons why scientists with differing default hypotheses can disagree in high-profile situations. Examples can be found in recent correspondence in this journal, which may offer lessons for resolving challenges to mainstream science, particularly when adherents of a minority view attempt to elevate the status of outlier studies and/or claim that self-interest explains the acceptance of the dominant theory. Edward J. Calabrese and I have been debating the historical origins of the linear no-threshold theory (LNT) of carcinogenesis and its use in the regulation of ionizing radiation. Professor Calabrese, a supporter of hormesis, has charged a committee of scientists with misconduct in their preparation of a 1956 report on the genetic effects of atomic radiation. Specifically he argues that the report mischaracterized the LNT research record and suppressed calculations of some committee members. After reviewing the available scientific literature, I found that the contemporaneous evidence overwhelmingly favored a (genetics) LNT and that no calculations were suppressed. Calabrese's claims about the scientific record do not hold up primarily because of lack of attention to statistical analysis. Ironically, outlier studies were more likely to favor supra-linearity, not sub-linearity. Finally, the claim of investigator bias, which underlies Calabrese's accusations about key studies, is based on misreading of text. Attention to ethics charges, early on, may help seed a counter narrative explaining the community's adoption of a default hypothesis and may help focus attention on valid evidence and any real weaknesses in the dominant paradigm. - Highlights: • Edward J Calabrese has made a contentious challenge to mainstream radiobiological science. • Such challenges should not be neglected, lest they enter the political arena without review. • Key genetic studies from the 1940s, challenged by Calabrese, were found consistent and unbiased. • A 1956 genetics report did not hide estimates and does not need investigation for misconduct. • The scientific record was strong for a no-threshold, linear genetic response to radiation.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Radiobiologic Parameters and Local Effect Model Predictions for Head-and-Neck Squamous Cell Carcinomas Exposed to High Linear Energy Transfer Ions

Purpose: To establish the radiobiologic parameters of head-and-neck squamous cell carcinomas (HNSCC) in response to ion irradiation with various linear energy transfer (LET) values and to evaluate the relevance of the local effect model (LEM) in HNSCC. Methods and Materials: Cell survival curves were established in radiosensitive SCC61 and radioresistant SQ20B cell lines irradiated with [33.6 and 184 keV/n] carbon, [302 keV/n] argon, and X-rays. The results of ion experiments were confronted to LEM predictions. Results: The relative biologic efficiency ranged from 1.5 to 4.2 for SCC61 and 2.1 to 2.8 for SQ20B cells. Fixing an arbitrary D{sub 0} parameter, which characterized survival to X-ray at high doses (>10 Gy), gave unsatisfying LEM predictions for both cell lines. For D{sub 0} = 10 Gy, the error on survival fraction at 2 Gy amounted to a factor of 10 for [184 keV/n] carbon in SCC61 cells. We showed that the slope (s{sub max}) of the survival curve at high doses was much more reliable than D{sub 0}. Fitting s{sub max} to 2.5 Gy{sup -1} gave better predictions for both cell lines. Nevertheless, LEM could not predict the responses to fast and slow ions with the same accuracy. Conclusions: The LEM could predict the main trends of these experimental data with correct orders of magnitude while s{sub max} was optimized. Thus the efficiency of carbon ions cannot be simply extracted from the clinical response of a patient to X-rays. LEM should help to optimize planning for hadrontherapy if a set of experimental data is available for high-LET radiations in various types of tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sensitivity Analysis of Parameters in Linear-Quadratic Radiobiologic Modeling

Purpose: Radiobiologic modeling is increasingly used to estimate the effects of altered treatment plans, especially for dose escalation. The present article shows how much the linear-quadratic (LQ) (calculated biologically equivalent dose [BED] varies when individual parameters of the LQ formula are varied by {+-}20% and by 1%. Methods: Equivalent total doses (EQD2 = normalized total doses (NTD) in 2-Gy fractions for tumor control, acute mucosal reactions, and late complications were calculated using the linear- quadratic formula with overall time: BED = nd (1 + d/ [{alpha}/{beta}]) - log{sub e}2 (T - Tk) / {alpha}Tp, where BED is BED = total dose x relative effectiveness (RE = nd (1 + d/ [{alpha}/{beta}]). Each of the five biologic parameters in turn was altered by {+-}10%, and the altered EQD2s tabulated; the difference was finally divided by 20. EQD2 or NTD is obtained by dividing BED by the RE for 2-Gy fractions, using the appropriate {alpha}/{beta} ratio. Results: Variations in tumor and acute mucosal EQD ranged from 0.1% to 0.45% per 1% change in each parameter for conventional schedules, the largest variation being caused by overall time. Variations in 'late' EQD were 0.4% to 0.6% per 1% change in the only biologic parameter, the {alpha}/{beta} ratio. For stereotactic body radiotherapy schedules, variations were larger, up to 0.6 to 0.9 for tumor and 1.6% to 1.9% for late, per 1% change in parameter. Conclusions: Robustness occurs similar to that of equivalent uniform dose (EUD), for the same reasons. Total dose, dose per fraction, and dose-rate cause their major effects, as well known.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Radiobiological Analysis of Multicenter Data for Postoperative Keloid Radiotherapy

Purpose: To identify factors significantly affecting recurrence rates after postoperative external beam radiotherapy (XRT) of keloids, and to delineate any radiation dose response and effects of radiation dose per fraction. Methods and Materials: A comprehensive literature review was performed to compile a database of 2,515 resected keloids (36.9% earlobe). Postoperative XRT was 45- to 100-kV X-rays in 27.0% or 120- to 250-kV X-rays in 11.1%, Co-60 in 1.9%, Sr-90 in 4.7%, 1.5- to 9-MeV electrons in 26.5%, and no XRT in 28.8%. In the 1,791 irradiated patients, the median radiation parameters were as follows: total dose, 15 Gy (range, 6-30 Gy); dose per fraction, 5.0 Gy (range, 2-15 Gy); fractions, 3 (range, 1-10); and time, 7 days (range, 0-33 days). Results: Multivariate stepwise logistic regression correlated decreased keloid recurrence with earlobe location (p = 1.98E-10; odds ratio, 0.34), biologically effective dose (p = 1.01E-27), and treatment with electron beam or Co-60 vs. other techniques (p = 0.0014; odds ratio, 0.72). Different radiobiological models calculated values of {alpha}/{beta} = 1.12 to 2.86 (mean, 2.08) and time (repopulation) correction factors for biologically effective dose from 0.98 to 2.13 Gy per day (mean, 1.34) starting 10 days after surgery. Different models (with {alpha}/{beta} = 2.08) predicted that doses needed for 90% and 95% control with 3 fractions of postoperative electron beam were 16.0 to 16.2 Gy and 18.3 to 19.2 Gy, respectively, in less than 10 days for earlobe keloids and 21.5 to 22.2 Gy and 23.4 to 24.8 Gy, respectively, in less than 10 days for other sites. Conclusions: Postoperative keloid radiotherapy requires moderately high doses and optimal technique to be effective. The relatively low {alpha}/{beta} ratio indicates that radiotherapy with a limited number of fractions and high doses per fraction is the best strategy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Revising the Radiobiological Model of Synchronous Chemotherapy in Head-and-Neck Cancer: A New Analysis Examining Reduced Weighting of Accelerated Repopulation

Purpose: Previous studies of synchronous chemoradiation therapy have modeled the additional effect of chemotherapy as additional radiation therapy biologically effective dose (BED). Recent trials of accelerated versus conventional fractionation chemoradiation have cast doubt on such modeling. The purpose of this study was to identify alternative models. Methods and Materials: Nine trials of platinum-based chemoradiation were identified. In radiation therapy-alone arms, the radiation therapy BED for tumor was calculated using standard parameters. In chemoradiation arms, 3 methods were used to calculate tumor BED (tBED): additional BED, addition of 9.3 Gy BED for tumor to the radiation therapy BED; zero repopulation, BED with no correction for repopulation; variable t{sub p} (the average doubling time during accelerated repopulation), values of t{sub p} 3-10 were used to examine a partial suppression of repopulation. The correlations between the calculated percentage change in tBED for each method and observed percentage change in local control were assessed using the Pearson product moment correlation. Results: Significant correlations were obtained for all 3 methods but were stronger with zero repopulation (P=.0002) and variable t{sub p} (t{sub p} = 10) (P=.0005) than additional BED (P=.02). Conclusions: Radiobiological models using modified parameters for accelerated repopulation seem to correlate strongly with outcome in chemoradiation studies. The variable t{sub p} method shows strong correlation for outcome in local control and is potentially a more suitable model in the chemoradiation setting. However, a lack of trials with an overall treatment time of more than 46 days inhibits further differentiation of the optimal model.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pneumonia After Bacterial or Viral Infection Preceded or Followed by Radiation Exposure: A Reanalysis of Older Radiobiologic Data and Implications for Low-Dose Radiation Therapy for Coronavirus Disease 2019 Pneumonia

Currently, there are about 15 ongoing clinical studies on low dose radiation therapy for Coronavirus Disease 2019 pneumonia. One of the underlying assumptions is that irradiation of 0.5 to 1.5 Gy is effective at ameliorating viral pneumonia. We aimed to reanalyze all available experimental radiobiologic data to assess evidence for such amelioration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric and Radiobiologic Comparison of 3D Conformal Versus Intensity Modulated Planning Techniques for Prostate Bed Radiotherapy

Adjuvant radiotherapy for locally advanced prostate cancer improves biochemical and clinical disease-free survival. While comparisons in intact prostate cancer show a benefit for intensity modulated radiation therapy (IMRT) over 3D conformal planning, this has not been studied for post-prostatectomy radiotherapy (RT). This study compares normal tissue and target dosimetry and radiobiological modeling of IMRT vs. 3D conformal planning in the postoperative setting. 3D conformal plans were designed for 15 patients who had been treated with IMRT planning for salvage post-prostatectomy RT. The same computed tomography (CT) and target/normal structure contours, as well as prescription dose, was used for both IMRT and 3D plans. Normal tissue complication probabilities (NTCPs) were calculated based on the dose given to the bladder and rectum by both plans. Dose-volume histogram and NTCP data were compared by paired t-test. Bladder and rectal sparing were improved with IMRT planning compared to 3D conformal planning. The volume of the bladder receiving at least 75% (V75) and 50% (V50) of the dose was significantly reduced by 28% and 17%, respectively (p = 0.002 and 0.037). Rectal dose was similarly reduced, V75 by 33% and V50 by 17% (p = 0.001 and 0.004). While there was no difference in the volume of rectum receiving at least 65 Gy (V65), IMRT planning significant reduced the volume receiving 40 Gy or more (V40, p = 0.009). Bladder V40 and V65 were not significantly different between planning modalities. Despite these dosimetric differences, there was no significant difference in the NTCP for either bladder or rectal injury. IMRT planning reduces the volume of bladder and rectum receiving high doses during post-prostatectomy RT. Because of relatively low doses given to the bladder and rectum, there was no statistically significant improvement in NTCP between the 3D conformal and IMRT plans.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparative dosimetric and radiobiological assessment among a nonstandard RapidArc, standard RapidArc, classical intensity-modulated radiotherapy, and 3D brachytherapy for the treatment of the vaginal vault in patients affected by gynecologic cancer

To evaluate a nonstandard RapidArc (RA) modality as alternative to high-dose-rate brachytherapy (HDR-BRT) or IMRT treatments of the vaginal vault in patients with gynecological cancer (GC). Nonstandard (with vaginal applicator) and standard (without vaginal applicator) RapidArc plans for 27 women with GC were developed to compare with HDR-BRT and IMRT. Dosimetric and radiobiological comparison were performed by means of dose-volume histogram and equivalent uniform dose (EUD) for planning target volume (PTV) and organs at risk (OARs). In addition, the integral dose and the overall treatment times were evaluated. RA, as well as IMRT, results in a high uniform dose on PTV compared with HDR-BRT. However, the average of EUD for HDR-BRT was significantly higher than those with RA and IMRT. With respect to the OARs, standard RA was equivalent of IMRT but inferior to HDR-BRT. Furthermore, nonstandard RA was comparable with IMRT for bladder and sigmoid and better than HDR-BRT for the rectum because of a significant reduction of d{sub 2cc}, d{sub 1cc}, and d{sub max} (p < 0.01). Integral doses were always higher than HDR-BRT, although the values were very low. Delivery times were about the same and more than double for HDR-BRT compared with IMRT and RA, respectively. In conclusion, the boost of dose on vaginal vault in patients affected by GC delivered by a nonstandard RA technique was a reasonable alternative to the conventional HDR-BRT because of a reduction of delivery time and rectal dose at substantial comparable doses for the bladder and sigmoid. However HDR-BRT provides better performance in terms of PTV coverage as evidenced by a greater EUD.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric and radiobiological comparison of volumetric modulated arc therapy, high-dose rate brachytherapy, and low-dose rate permanent seeds implant for localized prostate cancer

To investigate the dosimetric and radiobiological differences among volumetric modulated arc therapy (VMAT), high-dose rate (HDR) brachytherapy, and low-dose rate (LDR) permanent seeds implant for localized prostate cancer. A total of 10 patients with localized prostate cancer were selected for this study. VMAT, HDR brachytherapy, and LDR permanent seeds implant plans were created for each patient. For VMAT, planning target volume (PTV) was defined as the clinical target volume plus a margin of 5 mm. Rectum, bladder, urethra, and femoral heads were considered as organs at risk. A 78 Gy in 39 fractions were prescribed for PTV. For HDR and LDR plans, the dose prescription was D{sub 90} of 34 Gy in 8.5 Gy per fraction, and 145 Gy to clinical target volume, respectively. The dose and dose volume parameters were evaluated for target, organs at risk, and normal tissue. Physical dose was converted to dose based on 2-Gy fractions (equivalent dose in 2 Gy per fraction, EQD{sub 2}) for comparison of 3 techniques. HDR and LDR significantly reduced the dose to rectum and bladder compared with VMAT. The D{sub mean} (EQD{sub 2}) of rectum decreased 22.36 Gy in HDR and 17.01 Gy in LDR from 30.24 Gy in VMAT, respectively. The D{sub mean} (EQD{sub 2}) of bladder decreased 6.91 Gy in HDR and 2.53 Gy in LDR from 13.46 Gy in VMAT. For the femoral heads and normal tissue, the mean doses were also significantly reduced in both HDR and LDR compared with VMAT. For the urethra, the mean dose (EQD{sub 2}) was 80.26, 70.23, and 104.91 Gy in VMAT, HDR, and LDR brachytherapy, respectively. For localized prostate cancer, both HDR and LDR brachytherapy were clearly superior in the sparing of rectum, bladder, femoral heads, and normal tissue compared with VMAT. HDR provided the advantage in sparing of urethra compared with VMAT and LDR.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiobiological study by using laser-driven proton beams

Particle acceleration driven by high-intensity laser systems is widely attracting interest as a potential alternative to conventional ion acceleration, including ion accelerator applications to tumor therapy. Recent works have shown that a high intensity laser pulse can produce single proton bunches of a high current and a short pulse duration. This unique feature of laser-ion acceleration can lead to progress in the development of novel ion sources. However, there has been no experimental study of the biological effects of laser-driven ion beams. We describe in this report the first demonstrated irradiation effect of laser-accelerated protons on human lung cancer cells. In-vitro A549 cells are irradiated with a proton dose of 20 Gy, resulting in a distinct formation of gamma-H2AX foci as an indicator of DNA double-strand breaks. This is a pioneering result that points to future investigations of the radiobiological effects of laser-driven ion beams. The laser-driven ion beam is apotential excitation source for time-resolved determination of hydroxyl (OH) radical yield, which will explore relationship between the fundamental chemical reactions of radiation effects and consequent biological processes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗