Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION SOURCES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Real-time Object Bounding in LiDAR Data With Computer Vision

The Multimodal Measurement System is a roadside radiation measurement testbed used to detect radiation sources in passing vehicles. It works by combining sensor signals from various modalities to produce a thorough scan of the source. A LiDAR sensor is used to measure the dimensions of the vehicle and provide a velocity estimate. However, the current LiDAR setup uses propriety software for which the source code is unavailable and cannot be updated to improve performance. Therefore, it is imperative to the accuracy of the analysis to create a custom vehicle detection that can return the dimensions and velocity of passing vehicles in real time. This new custom detection is written in C++ using the PointCloud Library, which keeps it lightweight. It also utilizes Docker and the Robot Operating System, which allows the versatility of running both on a small computer or the Lawrence Livermore National Laboratory cluster while utilizing different models of LiDAR sensors. The custom detection outperforms the current detection model, which increases the accuracy of radiation source detection.

97 MATHEMATICS AND COMPUTING↗

Methods for aligning a spectrometer

An example method for aligning a spectrometer is described herein. The spectrometer includes a radiation source, a crystal analyzer, and a detector that are all positioned on an instrument plane. The method includes rotating the crystal analyzer about an axis that is within the instrument plane and perpendicular to a rotation plane such that (i) a reciprocal lattice vector of the crystal analyzer is within the instrument plane or (ii) a component of the reciprocal lattice vector within the rotation plane is perpendicular to the instrument plane. An origin of the reciprocal lattice vector is located on the axis. The method further includes tilting the crystal analyzer or translating the detector such that the reciprocal lattice vector bisects a line segment that is bounded by the detector and the radiation source. Example spectrometers related to the example method are also disclosed.

Mortensen, Devon R.↗

Apparatuses and methods for optical code-delay reflectometry (OcoDR)

Apparatuses and methods for optical code-delay reflectometry (OCoDR) are disclosed. An apparatus includes a modulator, a receiver, and control circuitry. The modulator is configured to receive incident electromagnetic (EM) radiation at a substantially fixed frequency generated by one or more EM radiation sources. The incident EM radiation includes continuous-wave EM radiation. The modulator is configured to impart a sequence onto an amplitude, a phase, or both of the incident EM radiation to generate modulated EM radiation. The modulated EM radiation includes continuous-wave EM radiation. The receiver is configured to receive reference EM radiation. The receiver is also configured to receive reflected EM radiation from an optical system responsive to the modulated EM radiation and generate interfered EM radiation responsive to the reference EM radiation and the reflected EM radiation. The receiver is further configured to generate a continuous interferogram responsive to the interfered EM radiation.

Seeley, Ryan↗

Multifaceted radiation detection and classification system

A system identifying a source of radiation is provided. The system includes a radiation source detector and a radiation source identifier. The radiation source detector receives measurements of radiation; for one or more sources, generates a detection metric indicating whether that source is present in the measurements; and evaluates the detection metrics to detect whether a source is present in the measurements. When the presence of a source in the measurements is detected, the radiation source identifier for one or more sources, generates an identification metric indicating whether that source is present in the measurements; generates a null-hypothesis metric indicating whether no source is present in the measurements; evaluates the one or more identification metrics and the null-hypothesis metric to identify the source, if any, that is present in the measurements.

Labov, Simon E.↗

Multifaceted radiation detection and classification system

A system identifying a source of radiation is provided. The system includes a radiation source detector and a radiation source identifier. The radiation source detector receives measurements of radiation; for one or more sources, generates a detection metric indicating whether that source is present in the measurements; and evaluates the detection metrics to detect whether a source is present in the measurements. When the presence of a source in the measurements is detected, the radiation source identifier for one or more sources, generates an identification metric indicating whether that source is present in the measurements; generates a null-hypothesis metric indicating whether no source is present in the measurements; evaluates the one or more identification metrics and the null-hypothesis metric to identify the source, if any, that is present in the measurements.

Labov, Simon E.↗

RadSim: Particle Transport Wrapper

RadSim is being developed to provide the capability to simulate radiation source emissions, interpolate results from radiation transport tools into a common format to prepare incident flux, and model radiation detector response. This software package includes wrapper API code which is utilized in the development of the second (transport) task of the RadSim project. This software package only contains tools to interface RadSim with radiation transport tools (GEANT4 and MCNP) and does not include any part of the transport source code itself. The users will need prior access to the transport tools (GEANT4 and MCNP), and can use this software package to interface with the transport tool of their choice. This software package takes the geometry file for a radiation transport problem and converts it into an input deck for the transport tools (GEANT4 and MCNP). Additionally, it also contains filters that convert the output of the transport tools to a common flux format.

Cheung, Hoi Sing↗

Thermionic microwave gun for terahertz and synchrotron light sources

Conventional thermionic microwave and radiofrequency (RF) guns can offer high average beam current, which is important for synchrotron light and terahertz (THz) radiation source facilities, as well as for industrial applications. For example, the Advanced Photon Source at Argonne National Laboratory is a national synchrotron radiation light source research facility that utilizes thermionic RF guns. Yet, these existing thermionic guns are bulky, difficult to handle and install, easily detuned, very sensitive to thermal expansion, and are due for a major upgrade and replacement. Here, we present the design of a new, more stable and reliable gun with optimized electromagnetic performance, improved thermal engineering and a more robust cathode mounting technique, which is a critical step to improve the performance of existing and future light sources, industrial accelerators, and electron beam-driven terahertz sources. We will also present a fabricated gun prototype and show results of high-power and beam tests.

47 OTHER INSTRUMENTATION↗

Systems, method and computer-accessible medium for providing balanced asymmetric interferometry for vibrationally isolated optical scanning probe(s)

An exemplary apparatus can provide radiation to a sample(s), which can include, for example, a radiation source arrangement configured to provide radiation, a beam splitter configured to split the radiation into (i) a first radiation, and (ii) a second radiation. An optical element can also be provided which, in operation, can, e.g., (a) receive the first radiation and the second radiation, (b) reflect the first radiation as a reference radiation, (c) provide the second radiation as illumination for the sample(s), (d) receive a resultant radiation from the sample(s) that can be based on the illumination from the second radiation, and (e) provide the reference radiation and the resultant radiation to be detected and used for interferometric imaging or spectroscopy.

McLeod, Alexander Swinton↗

RadSim: Math, Utility & RTK

This package includes three parts, (1) gov.llnl.math, (2)gov.llnl.utility and (3)gov.llnl.rtk, which are utilized in the development of Radiation Detector Simulator (RadSim) project. RadSim is being developed to provide the capability to: (1) simulate radiation source emissions, (2) interpolate results from radiation transport tools into a common format to prepare incident flux, and (3) model radiation detector response to rapidly produce synthetic radiation measurement templates. RadSim is targeted for open-source release, which will enable researchers and industry partners to model gamma-ray detectors response to simulated flux from the transport tool of their choice. The techniques and implementation will be entirely transparent, which will allow for improvements and boutique modifications by future researchers beyond the lifespan of this specific project. The first tool of the package, gov.llnl.math, includes classes and functions to define and perform basic math operations. Some of the example features available in the package include defining statistical distributions and performing algebra and matrix operations, all of which are already accessible on publicly available software packages such as MATLAB and ROOT. The second package gov.llnl.utility includes tools commonly used to enable optimization and readability of various data structures such as Java lists and external xml files. Lastly, the gov.llnl.rtk package includes classes and functions to implement methods commonly used in radiation physics, such as data structures to represent and characterize photon spectra and tools to apply well-defined and published methods to calibrate a given spectra.

Cheung, Hoi Sing↗

RadSim: ENSDF, Xray and N42

This package includes three parts, (1) gov.bnl.nndc.ensdf, (2) gov.nist.xray and (3) gov.nist.physics.n42, which are utilized in the development of Radiation Detector Simulator (RadSim) project. RadSim is being developed to provide the capability to: (1) simulate radiation source emissions, (2) interpolate results from radiation transport tools into a common format to prepare incident flux, and (3) model radiation detector response to rapidly produce synthetic radiation measurement templates. RadSim is targeted for open-source release, which will enable researchers and industry partners to model gamma-ray detectors response to simulated flux from the transport tool of their choice. The first tool of the package, gov.bnl.nndc.ensdf, includes functionality to parse and split publicly available decay records in ENSDF format, and pull the relevant information from ENSDF libraries. The second tool, gov.nist.xray, provides Xray information using the public NIST database. Lastly, gov.nist.physics.n42, is a tool used to convert an N42 xml file into a Java object that can be interfaced within a Java program.

Hangal, DnaushA↗

Broadband impedance modeling and single bunch instabilities estimations of the advanced light source upgrade project

We report the Advanced Light Source Upgrade (ALS-U) is a 4th generation diffraction-limited soft x-ray radiation source, consisting of a new accumulator ring (AR) and a new storage ring (SR). In both rings coupling-impedance driven instabilities need careful evaluation to ensure meeting the machine’s high-performance goals. This paper presents the workflow followed in building the impedance models and the beam-stability analysis based on those models. We follow the commonly accepted approach of separating the resistive-wall and the geometric parts of the impedance; the former is obtained by analytical formulas, the latter by numerical electro-magnetic codes (primarily CST Studio software) with perfectly-conducting boundary conditions. Impedance budgets are established and pseudo-Green functions calculated to be used in beam dynamics studies. We also present various ways to cross-check simulation results for reliable impedance modeling. Finally, the crucial single-bunch instability current thresholds for various operation modes are determined and discussed.

07 ISOTOPE AND RADIATION SOURCES↗

Memory and CPU efficient coherent mode decomposition of partially coherent synchrotron radiation with subtraction of common quadratic phase terms

Application examples of a memory and CPU efficient coherent mode decomposition (CMD) method for wave-optics based simulation of the partially coherent undulator radiation propagation through a hard X-ray beamline in a 3rd generation synchrotron radiation source are presented. The high efficiency of the method is achieved thanks to the analytical treatment of the common quadratic phase terms that are developed in the phase of cross-spectral density (CSD) of partially coherent radiation at a distance from source. This treatment allows for a considerable, several orders of magnitude, reduction of the 4D CSD mesh density (and the memory occupied by the CSD) required for ensuring sufficient accuracies of wavefront propagation simulations with the modes produced by the CMD at a beamline entrance. This method, implemented in the “Synchrotron Radiation Workshop” open-source software, dramatically increases the feasibility of the CMD of 4D CSD for producing 2D coherent modes for a large variety of applications at storage rings and other types of radiation sources.

36 MATERIALS SCIENCE↗

Evaluation of simulated HPGe detector efficiencies in OpenMC compared to MCNP

In late 2023, the open-source radiation transport code OpenMC introduced a pulse-height tally (PHT) feature, enabling users to track the total energy deposited by individual photons in OpenMC cells. This function represents an important improvement of the OpenMC code because it allows users to simulate the response function of a gamma detector without relying on closed-source alternatives. Despite this, limited work has been published evaluating OpenMC as a radiation transport code for simulating gamma spectroscopy experiments. This study attempts to demonstrate the usefulness of OpenMC in this space by directly comparing its PHT output to MCNP (a trusted industry-standard Monte Carlo code). In the first half of this study, a radiation transport experiment is described in which a detector with a complex internal geometry is exposed to various gamma-emitting isotopes ( 133 Ba, 137 Cs, and 60 Co) over a range of distances. The setup of this experiment was modeled in MCNP with sufficient detail to capture the efficiency characteristics of a high purity germanium (HPGe) detector for the primary gammas of each isotope. After good agreement between the MCNP model and experiment was achieved, an identical model was produced in OpenMC to allow direct comparison between the full energy peak (FEP) values produced in OpenMC and MCNP. The results show strong agreement between OpenMC and MCNP across the full range of tested energies, with each model’s FEP values typically within 2% of each other and most FEP areas within 4% of experimental data. Worse agreement was seen between the Monte Carlo codes and experiment below 300 keV (an expected result). For the 662 keV line of 137 Cs, both codes were found in poor agreement with experiment and each other over the full range of distances tested (possibly indicating an error with the 137 Cs experimental data). Ignoring the anomalous results of the 662 keV line, all other data show good qualitative and quantitative agreement between MCNP and OpenMC. This result demonstrates the accuracy of OpenMC’s PHT feature for spectroscopic applications in which detector efficiency is a primary concern.

07 - ISOTOPES AND RADIATION SOURCES↗

AXIOM Unfold 0.7.0, Users Manual

The AXIOM-Unfold application is a computational code for performing spectral unfolds along with uncertainty quantification of the photon spectrum. While this code was principally designed for spectral unfolds on the Saturn source, it is also relevant to other radiation sources such as Pithon. This code is a component of the AXIOM project which was undertaken in order to measure the time-resolved spectrum of the Saturn source; to support this, the AXIOM-Unfold code is able to process time-dependent dose measurements in order to obtain a time-resolved spectrum. This manual contains a full description of the algorithms used by the method. The code features are fully documented along with several worked examples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

User’s Manual for RESRAD-BUILD Code V.4: Vol. 1 – Methodology and Models Used in RESRAD-BUILD Code

The RESRAD-BUILD computer code models radionuclide release and transport in indoor environments and performs pathway analyses to evaluate the potential radiological dose and risk incurred by an individual who works or lives in a building contaminated with radioactive material or housing radioactively contaminated furniture or equipment. The code provides four geometries to characterize a radiation source: point, line, area, and volume, in which radionuclides are homogeneously distributed. Radionuclides contained in a source are considered to be released to the indoor air due to various processes including erosion (mechanically or weathering), diffusion (for tritium and radon in a volume source), or emanation (radon in a point, line, or area source). The release can proceed through different time phases with different rates. In RESRAD-BUILD Version 4.0, a dynamic ventilation model is implemented to simulate the fate and transport of source material particles and radionuclides after their releases. This dynamic ventilation model considers (1) air exchange between rooms in the building and between the rooms and the outdoor environment, (2) deposition from air to floor, (3) resuspension from the floor to the air, and (4) periodical vacuuming that reduces the floor deposition. The fate and transport modeling provides estimates of radionuclide concentrations in the source, in the air, and on the floor at different times, which are then integrated over the exposure duration for the calculation of radiation doses and cancer risks. A single run of the RESRAD-BUILD code can model a building with up to 9 rooms, 10 sources, and 10 receptors. The potential radiation dose and cancer risk incurred by each receptor are calculated for seven exposure pathways: (1) external radiation directly from the sources (accounting for shielding), (2) external radiation from radioactive particles deposited on the floors, (3) external radiation from airborne radionuclides, (4) inhalation of airborne radionuclides, (5) inhalation of radon and radon progenies, (6) inadvertent ingestion of radioactive particles directly from the source, and (7) ingestion of radioactive particles deposited on the floors. Various exposure scenarios can be modeled with RESRAD-BUILD, including but are not limited to, office worker, renovation worker, decontamination worker, building visitor, and resident. Both deterministic and probabilistic analyses can be performed to obtain results in both text reports and graphic displays.

61 RADIATION PROTECTION AND DOSIMETRY↗

Performance evaluation of the USGS velocity model for the San Francisco Bay Area

In this study, we evaluated the performance of the United States Geological Survey velocity model developed for the San Francisco Bay Area (SFBA), version 21.1. The evaluation was performed through high-resolution three-dimensional physics-based ground motion simulations of seven small-magnitude earthquakes (ranging from magnitude 3.8 to 4.4) that occurred on the eastern side of the San Francisco Bay. The simulations were performed in the frequency range from 0 to 5 Hz with a minimum shear-wave velocity of 250 m/s, which allowed the capture of wave propagation effects of the near-surface soft materials that characterize local basins. Based on the direct comparison of Fourier amplitude spectra between recorded and simulated ground motions for more than 250 stations, we found that the velocity model generally performs well in the frequency range of 0.2–5 Hz. The median value of the Fourier amplitude residuals was found to be near zero for all seven earthquakes. The slight over-prediction of 0.2 log-natural units at frequencies above 3 Hz in our simulations was attributed to the potentially inaccurate representation of the source radiation pattern by a double-couple point source model, and simple representation of shallow small-scale underground structural complexity in the velocity model. Maps of spectral amplitude differences between the simulated and recorded data were used to identify areas responsible for systematic ground motion over-predictions or under-predictions. For example, while some sub-domains over soft sediments show over-prediction patterns, the block east of the Hayward fault is prone to exhibit patterns of under-prediction. These maps can be used to guide future refinements of the SFBA velocity model. Since our simulation methodology allows for the decoupling of the source and wave propagation effects, the ground motion data generated by our simulations can also be used to quantify the epistemic uncertainty due to the velocity model, in empirically based ground motion estimates for the SFBA.

58 GEOSCIENCES↗

Detection of Anomalies in Gamma Background Radiation Data with K-Means and Self-Organizing Map Clustering Algorithms (Consortium on Nuclear Security Technologies (CONNECT) Q1 Report)

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. The measurement data is a 2D matrix, where one dimension is gamma ray energy, and the other dimension is the number of measurements or total time. In principle, gamma radiation sources can be detected and identified from the measured data by their unique spectral lines. Detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. The objective of this work is to explore unsupervised machine learning (ML) algorithms for detection and identification of weak nuisances and anomalies events in the presence of highly fluctuating background. The challenge is that spectral lines of isotopes are difficult to observe in one-second measurements. Averaging over the entire measurement campaign data set reveals spectral lines of most common background isotopes. Spectral lines of orphan sources, which might appear only in a few measurements during the campaign, will be washed out if averaging is performed over the entire measurement data set. The approach we have explored consists of extracting one-second measurements containing weak spectral features through data clustering. Averaging one-second spectra in a cluster should reveal the presence of anomaly sources. We created two ML models using K-means clustering and Neural Network Self-organizing Map (SOM). Performance of these ML models was benchmarked using search data. One data set contained 137 Cs source, and another dataset contained 131 I source.

61 RADIATION PROTECTION AND DOSIMETRY↗