Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION LENGTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

A Measurement of $\nu_e$ Appearance and $\nu_\mu$ Disappearance Neutrino Oscillations with the NOvA Experiment

NOvA is a two-detector, neutrino oscillation experiment on an 810 km baseline in the NuMI beam at Fermilab. NuMI is an off-axis, narrow-band beam centered near 1.8 GeV and is configurable to send a high-purity $\nu_\mu$ or $\bar{\nu}_\mu$ neutrino flux which passes through the NOvA far detector, sensitive to $\nu_\mu$ and $\bar{\nu}_\mu$ disappearance and $\nu_e$ and $\bar{\nu}_e$ appearance. The NOvA near and far detectors are functionally identical, liquid scintillator trackers. They are finely segmented relative to the radiation length in the detectors allowing for the detailed reconstruction of electromagnetic shower necessary to identify $\nu_e$ CC events. Through a joint analysis of the appearance and disappearance oscillation channels using neutrino and anti-neutrino data, NOvA constrains the allowed parameter space in $\delta_{CP}$, the neutrino mass hierarchy, $\sin^2\theta_{23}$, and $\Delta m^2_{32}$. We observe 58 and 18 appearance candidates on an expected backgr ound of 15.06 and 5.32 events in neutrino and anti-neutrino mode, respectively. This observation gives a $1.77\sigma$ preference for the normal mass hierarchy and $1.7\sigma$ preference for $\theta_{23} > \pi/4$. NOvA will maintain its position as a long-baseline oscillation experiment with leading sensitivity for several more years in which time analysis will further disambiguate the fundamental neutrino parameters that determine oscillation behavior.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The energy spectrum of primary cosmic ray electrons from 2 GeV to 200 GeV.

Use of a balloon-borne counter telescope with a gas Cerenkov counter to measure the energy of primary cosmic ray electrons between 2 and 200 GeV. Electrons are identified by the characteristic electron-photon shower which they produce in a 15 radiation length deep stack of high-Z material interleaved with scintillation counters. Calibrations with monoenergetic electrons up to 14 GeV and monoenergetic protons up to 28 GeV from accelerators are used to develop criteria to statistically separate electrons from proton-induced events. The results from six balloon flights (total exposure time 63 hours) are combined to obtain the electron energy spectrum. Up to about 30 GeV, the spectrum measured in this experiment can be directly checked with calibrations and agrees well with results from other experiments. Above this energy, the flux reported in the present work is somewhat higher than the determinations reported by most other authors. An apparent flattening of the energy spectrum above 50 GeV is not regarded as significant. There is no evidence for a steepening of the spectrum at energies below 200 GeV.

Fanselow, J. L.↗

Electron showers of high primary energy in lead.

The development of electron cascade showers in a lead-scintillator sandwich of 8 plastic scintillators in about 20 radiation lengths of lead has been investigated. This detector, which was used for cosmic-ray studies, has been calibrated with electrons with energies from 2 to 15 GeV at SLAC. Measured shower profiles are presented, and expressions are given which allow an extrapolation of the measured data up to energies around 1000 GeV. The results are compared with analytical shower theories and Monte Carlo calculations.

Mueller, D.↗

Hodoscope Measurements of the Spectrum of Cosmic Electrons Between 10 Gev and 100 Gev

In an attempt to reduce divergences among independent measurements of the electron spectrum above 10 GeV, electrons were detected with the aid of a large hodoscope which incorporates 8 trays of Geiger tubes and 10 scintillation counters into a calorimeter containing 33 radiation lengths of lead. This instrument was thoroughly calibrated up to 9 GeV with an electron synchrotron and was flown twice at a depth of 5 g/sq cm for a total of 30 hours at ceiling. Electron showers at 10 GeV are completely contained within the calorimeter where their ionization is sampled twelve times, and where hodoscope trays provide information on the geometrical distribution of shower particles. Electrons appeared in a histogram of number of events vs. a X2 measure of goodness of fit to electron shower curves as a clearly resolved peak standing well above the nuclear background. The initial ionization and the lateral spread of shower particles are consistent with those of calibration electrons. In contrast, the behavior of the nuclear continuum associated with minimum ionizing incident particles is different from that of calibration electrons but similar to that of nuclear events associated with incident helium nuclei. The differential electron spectrum from 10 to 100 GeV was obtained.

Meegan, C. A.↗

Electron calibration on a high-energy cosmic ray detector.

The response of the GSFC High Energy Cosmic Ray Detector has been studied using electrons in the energy range from 5.4 to 18 GeV. A semiempirical analytic form has been developed to determine the starting points and the energies of electron-induced cascade showers. The energy resolution thus obtained has a full width at half maximum of 17%, and the starting point can be determined to within 0.1 to 0.2 radiation length. The results of this response calibration provide a basis on which cosmic ray electrons can be reliably identified and analyzed in the presence of a large proton background.

Crannell, C. J.↗

Gamma ray pulsars

Recent data from the high energy gamma ray experiment have revealed the existence of four pulsars emitting photons above 35 MeV. An attempt is made to explain the gamma ray emission from these pulsars in terms of an electron-photon cascade that develops in the magnetosphere of the pulsar. Although there is very little material above the surface of the pulsar, the very intense magnetic fields correspond to many radiation lengths which cause electrons to emit photons via magnetic bremsstrahlung and these photons to pair produce. The cascade develops until the mean photon energy drops below the pair production threshold which happens to be in the gamma ray range; at this stage the photons break out from the source.

Oegelman, H.↗

Gamma ray pulsars

Data from the SAS-2 high-energy gamma-ray experiment reveal the existence of four pulsars emitting photons above 35 MeV. An attempt is made to explain the gamma-ray emission from these pulsars in terms of an electron-photon cascade that develops in the magnetosphere of the pulsar. Although there is very little material above the surface of the pulsar, the very intense magnetic fields (10 to the 12th power gauss) correspond to many radiation lengths which cause electrons to emit photons by magnetic bremsstrahlung and which cause these photons to pair-produce. The cascade develops until the mean photon energy drops below the pair-production threshold which is in the gamma-ray range; at this stage, the photons break out from the source.

Oegelman, H.↗

Measurements of the reaction e/+/e/-/ yielding gamma-gamma at center-of-mass energies in the range 6.2-7.4 GeV

The cross section for the pair-annihilation reaction e(+)e(-) yields gamma-gamma were measured at center-of-mass energies in the range 6.2-7.4 GeV and at production angles close to 90 deg. The experimental apparatus consisted of two identical spectrometers which were set to view the luminous region at SPEAR-II from opposite directions at an azimuthal angle of 45 deg. In each spectrometer there was a NaI(TI) crystal 20 radiation lengths thick and 30 in. in diameter to measure the gamma-ray energies. Annihilation events were detected by an electronic trigger which required only the observation in coincidence of more than 0.2 GeV in each NaI(TI) crystal within + or - 15 nsec of the crossing beams. The observed rates of pair-annihilation events were found to be in agreement with those expected from quantum electrodynamics (QED) at all the center-of-mass energies used.

Hilger, E.↗

Observation of cosmic ray positrons from 5 to 25 GeV

The positron data gathered in conjunction with electron data published elsewhere is reported. The basic recognition scheme was to look for low mass positive particles that cause a cascade in a 7 radiation length shower counter. The mass criteria is imposed by selecting particles that were accompanied by Cherenkov light but whose rigidity was below the proton Cherenkov threshold. Thus the proton Cherenkov threshold represents an upper limit to the range of the experiment.

Golden, R. L.↗

Modular, thermal bus-to-radiator integral heat exchanger design for Space Station Freedom

The baseline concept is introduced for the 'integral heat exchanger' (IHX) which is the interface of the two-phase thermal bus with the heat-rejecting radiator panels. A direct bus-to-radiator heat-pipe integral connection replaces the present interface hardware to reduce the weight and complexity of the heat-exchange mechanism. The IHX is presented in detail and compared to the baseline system assuming certain values for heat rejection, mass per unit width, condenser capacity, contact conductance, and assembly mass. The spreadsheet comparison can be used to examine a variety of parameters such as radiator length and configuration. The IHX is shown to permit the reduction of panel size and system mass in response to better conductance and packaging efficiency. The IHX is found to be a suitable heat-rejection system for the Space Station Freedom because it uses present technology and eliminates the interface mechanisms.

Chambliss, Joe↗

Observations of cosmic-ray electrons and positrons using an imaging calorimeter

A ballon-borne magnet spectrometer system was flown for 5.5 hr at an altitude of more than 117,00 feet from Prince Albert, Saskatchewan (Canada), on 1989 September 5, when the Newark neutron monitor rate was 2952. The instrument was a modified version of the one used to observe antiprotons in 1979. The most significant modification was the addition of an imaging calorimeter, 7.33 radiation lengths thick. Inclusion of the calorimeter has significantly improved the ability to distinguish electrons and positrons from the other constituents of the cosmic rays. The absolute electron flux has been determined in the energy interval 1.3-26 GeV. The electron spectrum at the top of the atmosphere was found to be J(sub e-) = 177E(exp -(3.15+/-0.13)) electrons/ sq m/(sr s GeV) in the energy range 4.0-26 GeV. Below 4 GeV, the spectrum showed flattening, which is consistent with the effect of solar modulation. The e(+)/(e(+)+e(-)) ratio was found to be (0.11 +/- 0.03) in the energy range 5.2-13 GeV.

Golden, R. L.↗

Ozone, Tropospheric

In the early part of the 20th century, ground-based and balloon-borne measurements discovered that most of atmosphere's ozone is located in the stratosphere with highest concentrations located between 15 and 30 km (9,3 and 18.6 miles). For a long time, it was believed that tropospheric ozone originated from the stratosphere and that most of it was destroyed by contact with the earth's surface. Ozone, O3, was known to be produced by the photo-dissociation of molecular oxygen, O2, a process that can only occur at wavelengths shorter than 242 nm. Because such short-wave-length radiation is present only in the stratosphere, no tropospheric ozone production is possible by this mechanism. In the 1940s, however, it became obvious that production of ozone was also taking place in the troposphere. The overall reaction mechanism was eventually identified by Arie Haagen-Smit of the California Institute of Technology, in highly polluted southern California. The copious emissions from the numerous cars driven there as a result of the mass migration to Los Angeles after World War 2 created the new unpleasant phenomenon of photochemical smog, the primary component of which is ozone. These high levels of ozone were injuring vegetable crops, causing women's nylons to run, and generating increasing respiratory and eye-irritation problems for the populace. Our knowledge of tropospheric ozone increased dramatically in the early 1950s as monitoring stations and search centers were established throughout southern California to see what could be done to combat this threat to human health and the environment.

Fishman, Jack↗

Studies of Avalanche Photodiodes (APDS) as Readout Devices for Scintillating Fibers for High Energy Gamma-Ray Astronomy Telescopes

New gamma ray and charged particle telescope designs based on scintillating fiber arrays could provide low cost, high resolution, lightweight, very large area and multi radiation length instrumentation for planned NASA space exploration. The scintillating fibers low visible light output requires readout sensors with single photon detection sensitivity and low noise. The sensitivity of silicon Avalanche Photodiodes (APDS) matches well the spectral output of the scintillating fibers. Moreover, APDs have demonstrated single photon capability. The global aim of our work is to make available to NASA a novel optical detector concept to be used as scintillating fiber readouts and meeting the requirements of the new generations of space-borne gamma ray telescopes. We proposed to evaluate the feasibility of using RMD's small area APDs ((mu)APD) as scintillating fiber readouts and to study possible alternative (mu)APD array configurations for space borne readout scintillating fiber systems, requiring several hundred thousand to one million channels. The evaluation has been conducted in accordance with the task description and technical specifications detailed in the NASA solicitation "Studies of Avalanche Photodiodes (APD as readout devices for scintillating fibers for High Energy Gamma-Ray Astronomy Telescopes" (#8-W-7-ES-13672NAIS) posted on October 23, 1997. The feasibility study we propose builds on recent developments of silicon APD arrays and light concentrators advances at RMD, Inc. and on more than 5 years of expertise in scintillating fiber detectors. In a previous program we carried out the initial research to develop a high resolution, small pixel, solid-state, silicon APD array which exhibited very high sensitivity in the UV-VIS spectrum. This (mu)APD array is operated in Geiger mode and results in high gain (greater than 10(exp 8)), extremely low noise, single photon detection capability, low quiescent power (less than 10 (mu)W/pixel for 30 micrometers sensitive area diameter) and output in the 1-5 volt range. If successful, this feasibility study will make possible the development of a scintillating fiber detector with unsurpassed sensitivity, extremely low power usage, a crucial factor of merit for space based sensors and telescopes.

Vasile, Stefan↗

An Imaging Calorimeter for Access-Concept Study

A mission concept study to define the "Advanced Cosmic-ray Composition Experiment for Space Station (ACCESS)" was sponsored by the National Aeronautics and Space Administration (NASA). The ACCESS instrument complement contains a transition radiation detector and an ionization calorimeter to measure tile spectrum of protons, helium, and heavier nuclei up to approximately 10(exp 15) eV to search for the limit of S/N shock wave acceleration, or evidence for other explanations of the spectra. Several calorimeter configurations have been studied, including the "baseline" totally active bismuth germanate instrument and sampling calorimeters utilizing various detectors. The Imaging Calorimeter for ACCESS (ICA) concept comprises a carbon target and a calorimeter using a high atomic number absorber sampled approximately each radiation length (rl) by thin scintillating fiber (SCIFI) detectors. The main features and options of the ICA instrument configuration are described in this paper. Since direct calibration is not possible over most of the energy range, the best approach must be decided from simulations of calorimeter performance extrapolated from CERN calibrations at 0.375 TeV. This paper presents results from the ICA simulations study.

Parnell, T. A.↗

Advanced Thin Ionization Calorimeter (ATIC) Update

The Advanced Thin Ionization Calorimeter (ATIC) experiment is designed to measure the composition and energy spectra of Z = 1 to 28 cosmic rays over the energy range of approximately 10 GeV - 100 TeV. ATIC is comprised of an eight-layer, 18 radiation length deep Bismuth Germanate (BGO) calorimeter, downstream of a 0.75 nuclear interaction length graphite target and an approximately 1 sq m finely segmented silicon charge detector. Interleaved with the graphite layers are three scintillator strip hodoscopes for pre-triggering and tracking. ATIC flew for the first time on a Long Duration Balloon (LDB) launched from McMurdo, Antarctica in January 2001. During its 16-day flight ATIC collected more than 30 million science events, along with housekeeping, calibration, and rate data. This presentation will describe the ATIC data processing, including calibration and efficiency corrections, and show results from analysis of this dataset. The next launch is planned for December 2002.

Ahn, H. S.↗

Beam Tests of the Balloon-Borne ATIC Experiment

The Advanced Thin Ionization Calorimeter (ATIC) balloon-borne experiment is designed to perform cosmic-ray elemental spectra measurement from 50 GeV to 100 TeV for nuclei from hydrogen to iron. These measurements are expected to provide crucial hints about some of the most fundamental questions in astroparticle physics today. ATTIC'S design centers on an 18 radiation length (X(sub Omnicron)) deep bismuth germanate (BGO) calorimeter, preceded by a 0.75 lambda(sub int) graphite target. In September 1999 the ATIC detector was exposed to high-energy beams at CERN's SPS accelerator, within the framework of the development program for the Advanced Cosmic-ray Composition Experiment for the Space Station (ACCESS). In December 2000 - January 2001, ATIC flew on the first of a series of long duration balloon (LDB) flights from McMurdo Station, Antarctica. We present here results from the 1999 beam-tests, including energy resolutions for electrons and protons at several beam energies from 100 GeV to 375 GeV, as well as signal linearity and collection efficiency estimates. We show how these results compare with expectations based on simulations, and their expected impacts on mission performance.

Ganel, O.↗

Deconvolution of Energy Spectra in the ATIC Experiment

The Advanced Thin Ionization Calorimeter (ATIC) balloon-borne experiment is designed to perform cosmic- ray elemental spectra measurements from below 100 GeV up to tens TeV for nuclei from hydrogen to iron. The instrument is composed of a silicon matrix detector followed by a carbon target, interleaved with scintillator tracking layers, and a segmented BGO calorimeter composed of 320 individual crystals totalling 18 radiation lengths, used to determine the particle energy. The technique for deconvolution of the energy spectra measured in the thin calorimeter is based on detailed simulations of the response of the ATIC instrument to different cosmic ray nuclei over a wide energy range. The method of deconvolution is described and energy spectrum of carbon obtained by this technique is presented.

Batkov, K. E.↗

Temperature Effects in the ATIC BGO Calorimeter

The Advanced Thin Ionization Calorimeter (ATIC) Balloon Experiment contains a segmented calorimeter composed of 320 individual BGO crystals (18 radiation lengths deep) to determine the particle energy. Like all inorganic scintillation crystals the light output of BGO depends not only on the energy deposited by particles but also on the temperature of the crystal. ATIC had successful flights in 2000/2001 and 2002/2003 from McMurdo, Antarctica. The temperature of balloon instruments varies during their flights at altitude due to sun angle variations and differences in albedo from the ground and is monitored and recorded. In order to determine the temperature sensitivity of the ATIC calorimeter it was temperature cycled in the thermal vacuum chamber at the CSBF in Palestine, TX. The temperature dependence is derived from the pulse height response to cosmic ray muons at various temperatures.

Isbert, J.↗