Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Summary Report of the Seventh Annual NASA/Contractors Conference on Quality and Productivity: "Total Quality Leadership"

More than 750 NASA, government, contractor, and academic representatives attended the Seventh Annual NASA/Contractors Conference on Quality and Productivity on October 12-13, 1990, in Grenelefe, Florida. The panel presentations and keynote speeches revolving around the theme of 'Total Quality Leadership" provided a solid base of understanding of the importance, benefits, and principles of total quality management. The implementation of these strategies is critical if we are to effectively pursue our mission of continuous quality improvement and reliability in our products, processes, and services. The annual NASA/contractors conferences serve as catalysts for achieving success in this mission.

Source record↗

Parametric Analysis of Surveillance Quality and Level and Quality of Intent Information and Their Impact on Conflict Detection Performance

A loss-of-separation (LOS) is said to occur when two aircraft are spatially too close to one another. A LOS is the fundamental unsafe event to be avoided in air traffic management and conflict detection (CD) is the function that attempts to predict these LOS events. In general, the effectiveness of conflict detection relates to the overall safety and performance of an air traffic management concept. An abstract, parametric analysis was conducted to investigate the impact of surveillance quality, level of intent information, and quality of intent information on conflict detection performance. The data collected in this analysis can be used to estimate the conflict detection performance under alternative future scenarios or alternative allocations of the conflict detection function, based on the quality of the surveillance and intent information under those conditions.Alternatively, this data could also be used to estimate the surveillance and intent information quality required to achieve some desired CD performance as part of the design of a new separation assurance system.

Guerreiro, Nelson M.↗

Oklahoma Health and Air Quality: Mapping Air Quality Using NASA Earth Observations to Investigate Recent Increases in Ozone Concentrations

Tropospheric ozone (O3) is formed by anthropogenic pollutants interacting with sunlight and is considered harmful to human health in high concentrations. In the summer of 2018, the Oklahoma Department of Environmental Quality (DEQ) measured unexpected spikes in O3 in Seiling, Oklahoma, with concentrations exceeding those measured in bustling Oklahoma City and Tulsa. The DEQ tracks air quality using ground monitors and does not utilize Earth observation data in its monitoring or analysis. This project used remotely sensed data to investigate these2018 air quality anomalies, identifying possible causes. We analyzed atmospheric data from Terra and Aqua Moderate Resolution Imaging Spectroradiometer (MODIS), and Sentinel-5P Tropospheric Ozone Monitoring Instrument (TROPOMI) in conjunction with ground-based measurements of tropospheric ozone (O3), nitrogen dioxide (NO2), methane (CH4), carbon monoxide (CO), formaldehyde (HCHO) and aerosol optical depth (AOD). We compared Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) model simulations and Earth observation visualizations to pinpoint ozone spike causes. We also generated models to identify contributing factors to variations in ground ozone concentrations in our study area. The results point to a variety of ozone spike causes, primarily from outside of the state, and support the placement of additionalNO2, O3, and CO monitors to the southeast of Seiling. These analyses can help guide the placement of future monitors in the ground monitoring network and inform air quality regulations in Oklahoma.

Carolina Rosales↗

Competency in Quality: Defining the Scope and Nature of Quality Competencies for Radiation Oncology Residency Programs

Quality and safety in radiation treatment have garnered increasing attention in recent years. With the introduction of the CanMEDS 2015 Physician Competency Framework, incorporation of patient safety and quality improvement will be required across all seven established physician roles for radiation oncology residents. An appreciation for the competency areas relevant to radiation oncologists (ROs) in the quality and safety domain is thus needed to inform training in this area.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ultra-high quality factors in superconducting niobium cavities in ambient magnetic fields up to 190 mG

Ambient magnetic field, if trapped in the penetration depth, leads to the residual resistance and therefore sets the limit for the achievable quality factors in superconducting niobium resonators for particle accelerators. Here, we show that a complete expulsion of the magnetic flux can be performed and leads to: (1) record quality factors Q > 2 × 10{sup 11} up to accelerating gradient of 22 MV/m; (2) Q ∼ 3 × 10{sup 10} at 2 K and 16 MV/m in up to 190 mG magnetic fields. This is achieved by large thermal gradients at the normal/superconducting phase front during the cooldown. Our findings open up a way to ultra-high quality factors at low temperatures and show an alternative to the sophisticated magnetic shielding implemented in modern superconducting accelerators.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Model-Based Framework for Air Quality Indices and Population Risk Evaluation, with an Application to the Analysis of Scottish Air Quality Data

Summary The paper is devoted to the development of a statistical framework for air quality assessment at the country level and for the evaluation of the ambient population exposure and risk with respect to airborne pollutants. The framework is based on a multivariate space–time model and on aggregated indices defined at different levels of aggregation in space and time. The indices are evaluated, uncertainty included, by considering both the model outputs and the information on the population spatial distribution. The framework is applied to the analysis of air quality data for Scotland for 2009 referring to European and Scottish air quality legislation.

Unbalanced networks↗

A quality assurance framework for the fully automated and objective evaluation of image quality in cone-beam computed tomography

Purpose: Thousands of cone-beam computed tomography (CBCT) scanners for vascular, maxillofacial, neurological, and body imaging are in clinical use today, but there is no consensus on uniform acceptance and constancy testing for image quality (IQ) and dose yet. The authors developed a quality assurance (QA) framework for fully automated and time-efficient performance evaluation of these systems. In addition, the dependence of objective Fourier-based IQ metrics on direction and position in 3D volumes was investigated for CBCT. Methods: The authors designed a dedicated QA phantom 10 cm in length consisting of five compartments, each with a diameter of 10 cm, and an optional extension ring 16 cm in diameter. A homogeneous section of water-equivalent material allows measuring CT value accuracy, image noise and uniformity, and multidimensional global and local noise power spectra (NPS). For the quantitative determination of 3D high-contrast spatial resolution, the modulation transfer function (MTF) of centrally and peripherally positioned aluminum spheres was computed from edge profiles. Additional in-plane and axial resolution patterns were used to assess resolution qualitatively. The characterization of low-contrast detectability as well as CT value linearity and artifact behavior was tested by utilizing sections with soft-tissue-equivalent and metallic inserts. For an automated QA procedure, a phantom detection algorithm was implemented. All tests used in the dedicated QA program were initially verified in simulation studies and experimentally confirmed on a clinical dental CBCT system. Results: The automated IQ evaluation of volume data sets of the dental CBCT system was achieved with the proposed phantom requiring only one scan for the determination of all desired parameters. Typically, less than 5 min were needed for phantom set-up, scanning, and data analysis. Quantitative evaluation of system performance over time by comparison to previous examinations was also verified. The maximum percentage interscan variation of repeated measurements was less than 4% and 1.7% on average for all investigated quality criteria. The NPS-based image noise differed by less than 5% from the conventional standard deviation approach and spatially selective 10% MTF values were well comparable to subjective results obtained with 3D resolution pattern. Determining only transverse spatial resolution and global noise behavior in the central field of measurement turned out to be insufficient. Conclusions: The proposed framework transfers QA routines employed in conventional CT in an advanced version to CBCT for fully automated and time-efficient evaluation of technical equipment. With the modular phantom design, a routine as well as an expert version for assessing IQ is provided. The QA program can be used for arbitrary CT units to evaluate 3D imaging characteristics automatically.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality control for quantitative multicenter whole-body PET/MR studies: A NEMA image quality phantom study with three current PET/MR systems

Purpose: Integrated positron emission tomography/magnetic resonance (PET/MR) systems derive the PET attenuation correction (AC) from dedicated MR sequences. While MR-AC performs reasonably well in clinical patient imaging, it may fail for phantom-based quality control (QC). The authors assess the applicability of different protocols for PET QC in multicenter PET/MR imaging. Methods: The National Electrical Manufacturers Association NU 2 2007 image quality phantom was imaged on three combined PET/MR systems: a Philips Ingenuity TF PET/MR, a Siemens Biograph mMR, and a GE SIGNA PET/MR (prototype) system. The phantom was filled according to the EANM FDG-PET/CT guideline 1.0 and scanned for 5 min over 1 bed. Two MR-AC imaging protocols were tested: standard clinical procedures and a dedicated protocol for phantom tests. Depending on the system, the dedicated phantom protocol employs a two-class (water and air) segmentation of the MR data or a CT-based template. Differences in attenuation- and SUV recovery coefficients (RC) are reported. PET/CT-based simulations were performed to simulate the various artifacts seen in the AC maps (μ-map) and their impact on the accuracy of phantom-based QC. Results: Clinical MR-AC protocols caused substantial errors and artifacts in the AC maps, resulting in underestimations of the reconstructed PET activity of up to 27%, depending on the PET/MR system. Using dedicated phantom MR-AC protocols, PET bias was reduced to −8%. Mean and max SUV RC met EARL multicenter PET performance specifications for most contrast objects, but only when using the dedicated phantom protocol. Simulations confirmed the bias in experimental data to be caused by incorrect AC maps resulting from the use of clinical MR-AC protocols. Conclusions: Phantom-based quality control of PET/MR systems in a multicenter, multivendor setting may be performed with sufficient accuracy, but only when dedicated phantom acquisition and processing protocols are used for attenuation correction.

60 APPLIED LIFE SCIENCES↗

EERE Quality Control Workshop Final Report: Proceedings from the EERE Quality Control Workshop, in support of the DOE Clean Energy Manufacturing Initiative; Golden, Colorado, December 9-10, 2013

The U.S. Department of Energy Office of Energy Efficiency & Renewable Energy (EERE) has recognized the cross-cutting, pre-competitive and enabling nature of quality control for a wide range of clean energy technologies. As such, the Fuel Cell Technologies Office, Solar Energy Technologies Office, Vehicle Technologies Office, Building Technologies Office, and Advanced Manufacturing Office decided to explore needs and potential cross-office synergies in this area by holding the EERE Quality Control Workshop, in support of the DOE Clean Energy Manufacturing Initiative. This report summarizes the purpose and scope of the workshop; reviews the current status and state-of-the-art for in-line quality control; summarizes the results from three breakout sessions; and presents conclusions and recommendations.

14 SOLAR ENERGY↗

Challenging problems of quality assurance and quality control (QA/QC) of meteorological time series data

Abstract Representativeness and quality of collected meteorological data impact accuracy and precision of climate, hydrological, and biogeochemical analyses and predictions. We developed a comprehensive Quality Assurance (QA) and Quality Control (QC) statistical framework, consisting of three major phases: Phase I—Preliminary data exploration, i.e., processing of raw datasets, with the challenging problems of time formatting and combining datasets of different lengths and different time intervals; Phase II—QA of the datasets, including detecting and flagging of duplicates, outliers, and extreme data; and Phase III—the development of time series of a desired frequency, imputation of missing values, visualization and a final statistical summary. The paper includes two use cases based on the time series data collected at the Billy Barr meteorological station (East River Watershed, Colorado), and the Barro Colorado Island (BCI, Panama) meteorological station. The developed statistical framework is suitable for both real-time and post-data-collection QA/QC analysis of meteorological datasets.

54 ENVIRONMENTAL SCIENCES↗

Making Quality HPGe Gamma Ray Spectrum Measurements for Uranium: The Role of FRAM for Analysis, Quality Control and Enrichment Measurements, and Opportunities for Improved Quantification Documentation

Enrichment measurements are used in uranium safeguards verification and accountancy as both an attribute signature and in the interpretation of other nondestructive assay information, such as active interrogation for mass. Accurate and reliable assessments require quality information. The practices used to collect the raw data are therefore the crucial first step in managing the overall quality and uncertainty of the enrichment determination. This report discusses several topics associated with gamma-ray spectrum measurements of uranium using HPGe detectors. First a discussion of good data acquisition practices including physical setup, detector types and configurations, detector shielding and filtering, spectrum stabilization, and data acquisition protocols. Next is a discussion of analysis options to obtain isotopic composition and/or enrichment centered on the FRAM gamma ray isotopic analysis software. The report discusses the results of the development of a FRAM parameter file to perform classical Enrichment Meter Principle (EMP) analysis. Possible analysis and data acquisition issues (random summing, x-ray fluorescence peaks, peak interferences, shielding) that can affect FRAM analyses are also discussed. There is also a brief discussion of FRAM measurements in the field. Under the topic of uncertainty propagation and quantification in FRAM, uncertainty propagation verification methods and gaps in available uncertainty quantification data for uranium is covered. Suggestions are made for areas where ORNL can contribute to closing the identified uncertainty quantification gaps, and also to contributing nuclear data quality spectra to the research community.

61 RADIATION PROTECTION AND DOSIMETRY↗

The effect of variety and maturity on the quality of freeze-dried carrots. The effect of microwave blanching on the nutritional and textural quality of freeze-dried spinach

Using carrots, the quality of freeze-dried products was studied to determine the optimum varieties and maturation stages for quality attributes such as appearance, flavor, texture, and nutritive value. The quality of freeze-dried carrots is discussed in terms of Gardner color, alcohol insoluble solids, viscosity, and core/cortex ratio. Also, microwave blanching of freeze-dried spinach was studied to determine vitamin interrelationships, anatomical changes, and oxidative deteriorations in terms of preprocessing microwave treatments. Statistical methods were employed in the gathering of data and interpretation of results in both studies.

Source record↗

The Eighth Annual NASA/Contractors Conference and 1991 National Symposium on Quality and Productivity: Extending the boundaries of total quality management

The Eighth Annual NASA/Contractors Conference and 1991 National Symposium on Quality and Productivity provided a forum to exchange knowledge and experiences in these areas of continuous improvement. The more than 1,100 attendees from government, industry, academia, community groups, and the international arena had a chance to learn about methods, tools, and strategies for excellence and to discuss continuous improvement strategies, successes, and failures. This event, linked via satellite to concurrent conferences hosted by the NASA Goddard Space Flight Center in Greenbelt, Maryland, and Martin Marietta Astronautics Group in Denver, Colorado, also explored extending the boundaries of Total Quality Management to include partnerships for quality within communities and encouraged examination, evaluation, and change to incorporate the principles of continuous improvement.

Templeton, Geoffrey B.↗

Medical imaging using ionizing radiation: Optimization of dose and image quality in fluoroscopy

The 2012 Summer School of the American Association of Physicists in Medicine (AAPM) focused on optimization of the use of ionizing radiation in medical imaging. Day 2 of the Summer School was devoted to fluoroscopy and interventional radiology and featured seven lectures. These lectures have been distilled into a single review paper covering equipment specification and siting, equipment acceptance testing and quality control, fluoroscope configuration, radiation effects, dose estimation and measurement, and principles of flat panel computed tomography. This review focuses on modern fluoroscopic equipment and is comprised in large part of information not found in textbooks on the subject. While this review does discuss technical aspects of modern fluoroscopic equipment, it focuses mainly on the clinical use and support of such equipment, from initial installation through estimation of patient dose and management of radiation effects. This review will be of interest to those learning about fluoroscopy, to those wishing to update their knowledge of modern fluoroscopic equipment, to those wishing to deepen their knowledge of particular topics, such as flat panel computed tomography, and to those who support fluoroscopic equipment in the clinic.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the determination of reference levels for quality assurance of flattening filter free photon beams in radiation therapy

Purpose: New definitions for some dosimetric parameters for use in quality assurance of flattening filter free (FFF) beams generated by medical linear accelerators have been suggested. The present study aims to validate these suggestions and to propose possible reference levels. Methods: The main characteristics of FFF photon beams were described in terms of: field size, penumbra, unflatness, slope, and peak-position parameters. Data were collected for 6 and 10 MV-FFF beams from three different Varian TrueBeam Linacs. Measurements were performed with a 2D-array (Starcheck system from PTW-Freiburg) and with the portal dosimetry method GLAaS utilizing the build-in portal imager of TrueBeam. Data were also compared to ion chamber measurements. A cross check validation has been performed on a FFF beam of 6 MV generated by a Varian Clinac-iX upgraded to FFF capability. Results : All the parameters suggested to characterize the FFF beams resulted easily measurable and little variation was observed among different Linacs. Referring to two reference field sizes of 10 × 10 and 20 × 20 cm{sup 2}, at SDD = 100 cm and d = dmax, from the portal dosimetry data, the following results (averaging X and Y profiles) were obtained. Field size: 9.95 ± 0.02 and 19.98 ± 0.03 cm for 6 MV-FFF (9.94 ± 0.02 and 19.98 ± 0.03 cm for 10 MV-FFF). Penumbra: 2.7 ± 0.3 and 2.9 ± 0.3 mm for 6 MV-FFF (3.1 ± 0.2 and 3.3 ± 0.3 for 10 MV-FFF). Unflatness: 1.11 ± 0.01 and 1.25 ± 0.01 for 6 MV-FFF (1.21 ± 0.01 and 1.50 ± 0.01 for 10 MV-FFF). Slope: 0.320 ± 0.020%/mm and 0.43 ± 0.015%/mm for 6 MV-FFF (0.657 ± 0.023%/mm and 0.795 ± 0.017%/mm for 10 MV-FFF). Peak Position −0.2 ± 0.2 and −0.4 ± 0.2 mm for 6 MV-FFF (−0.3 ± 0.2 and 0.7 ± 0.3 mm for 10 MV-FFF). Results would depend upon measurement depth. With thresholds set to at least 95% confidence level from the measured data and to account for possible variations between detectors and methods and experimental settings, a tolerance set of: 1 mm for field size and penumbra, 0.04 for unflatness, 0.1%/mm for slope, and 1 mm for peak position could be proposed from our data. Conclusions : The parameters proposed for the characterization and routine control of stability of profiles of FFF beams appear to be a viable solution with a strong similarity to the conventional parameters used for flattened beams. The results from three different TrueBeams and the cross-validation against a Clinac-iX suggested the possible generalization of the methods and the possibility to use common tolerances for the parameters. The data showed also the reproducibility of beam characteristics among different systems (of the same vendor) and the resulting parameter values could therefore be possibly generalized.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

FedFleet 2024: Fleet Data Quality - Understanding and Improving Your Agency's FAST Fleet Data Quality Metric? [Slides]

This presentation presents an overview of how the team supporting the Federal Automotive Statistical Tool (FAST) project for DOE and GSA view and assess the quality of fleet data submissions from federal agencies. It also discusses ways in which agencies can improve the quality of their fleet data and of their fleet data submissions. FAST is a web-based information system sponsored by GSA's Office of Government-wide Policy and DOE's Federal Energy Management Program to collect information about the US federal government's fleet of motor vehicles; FAST is developed, maintained, and supported by DOE's Idaho National Laboratory (INL).

99 GENERAL AND MISCELLANEOUS↗