Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Pump probe spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Coherent Anti-Stokes Raman Scattering (CARS) as a Probe for Supersonic Hydrogen-Fuel/Air Mixing

The dual-pump coherent anti-Stokes Raman spectroscopy (CARS) method was used to measure temperature and the absolute mole fractions of N2, O2 and H2 in a supersonic non-reacting fuel-air mixing experiment. Experiments were conducted in NASA Langley Research Center s Direct Connect Supersonic Combustion Test Facility. Under normal operation of this facility, hydrogen and air burn to increase the enthalpy of the test gas and O2 is added to simulate air. This gas is expanded through a Mach 2 nozzle and into a combustor model where fuel is then injected, mixes and burns. In the present experiment the O2 of the test gas is replaced by N2. The lack of oxidizer inhibited combustion of the injected H2 fuel jet allowing the fuel/air mixing process to be studied. CARS measurements were performed 427 mm downstream of the nozzle exit and 260 mm downstream of the fuel injector. Maps were obtained of the mean temperature, as well as the N2, O2 and H2 mean mole fraction fields. A map of mean H2O vapor mole fraction was also inferred from these measurements. Correlations between different measured parameters and their fluctuations are presented. The CARS measurements are compared with a preliminary computational prediction of the flow.

Danehy, P. M.

Multiplet lines in seeded stimulated Mn 𝐾⁢𝛼 1 x-ray emission

We report the successful resolution of the multiplet structure of 𝐾⁢𝛼 1 x-ray emission in manganese (Mn) complexes through seeded stimulated x-ray emission spectroscopy (seeded S-XES). Using a femtosecond pump pulse above the Mn 𝐾 edge to generate simultaneous 1⁢𝑠 core holes, and a second-color tunable seed pulse to initiate the stimulated emission process, we were able to enhance individual lines within the 𝐾⁢𝛼 1 emission. This approach allows to resolve the fine multiplet features that are obscured by lifetime broadening in conventional (spontaneous) Mn 𝐾⁢𝛼 XES. The work builds on our previous observation that S-XES from Mn(II) and Mn(VII) complexes pumped at high intensities can exhibit stimulated emission without sacrificing the chemical sensitivity to oxidation states. Furthermore, this technique opens the door to controlled high-resolution electronic structure spectroscopy in transition-metal complexes beyond the core-hole lifetime, with potential applications in catalysis, inorganic chemistry, and materials science.

Chemical Physics & Physical Chemistry

On ultrafast x-ray scattering methods for magnetism

With the introduction of x-ray free electron laser sources around the world, new scientific approaches for visualizing matter at fundamental length and time-scales have become possible. As it relates to magnetism and ‘magnetic-type’ systems, advanced methods are being developed for studying ultrafast magnetic responses on the time-scales at which they occur. We describe three capabilities which have the potential to seed new directions in this area and present original results from each: pump-probe x-ray scattering with low energy excitation, x-ray photon fluctuation spectroscopy, and ultrafast diffuse x-ray scattering. By combining these experimental techniques with advanced modeling together with machine learning, we describe how the combination of these domains allows for a new understanding in the field of magnetism. Finally, we give an outlook for future areas of investigation and the newly developed instruments which will take us there.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Molecular velocimetry using stimulated Raman spectroscopy

Molecular flow velocity of N2 was measured in a supersonic wind tunnel using inverse Raman spectroscopy. This technique employs the large Doppler shift exhibited by the molecules when the pump and probe laser beams are counter-propagating (backward scattering). A retrometer system is employed to yield a vibration-free optical configuration which has the additional advantage of obtaining both the forward and backward scattered spectra simultaneously. The linebreadths and their relative Doppler shift can be used to determine the static pressure, translational temperature, and molecular flow velocity. A demonstration of the concept was performed in a supersonic wind tunnel and included: (1) measurements over the Mach number range 2.50 to 4.63; (2) static pressure measurements (at Mach 2.50) corresponding to a Reynolds number per foot range of 1 to 5 x 10 to the 6th power; and (3) measurements behind the shock wave of a flat plate model.

Exton, R. J.

Direct Observation of the ππ* to nπ* Transition in 2-Thiouracil via Time-Resolved NEXAFS Spectroscopy

The photophysics of nucleobases has been the subject of both theoretical and experimental studies over the past decades due to the challenges posed by resolving the steps of their radiationless relaxation dynamics, which cannot be described in the framework of the Born–Oppenheimer approximation (BOA). In this context, the ultrafast dynamics of 2-thiouracil has been investigated with a time-resolved NEXAFS study at the Free Electron Laser FLASH. Near Edge X-ray Absorption Fine Structure spectroscopy (NEXAFS) can be used to observe electronic transitions in ultrafast molecular relaxation. We performed time-resolved UV-pump/X-ray probe absorption measurements at the sulfur 2s (L1) and 2p (L2/3) edges. We are able to identify absorption features corresponding to the S2 (ππ*) and S1 (nπ*) electronic states. We observe a delay of 102 ± 11 fs in the population of the nπ* state with respect to the initial optical excitation and interpret the delay as the time scale for the S2 → S1 internal conversion. We furthermore identify oscillations in the absorption signal that match a similar observation in our previous X-ray photoelectron spectroscopy study on the same molecule.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Raman Doppler velocimetry - A unified approach for measuring molecular flow velocity, temperature, and pressure

Molecular flow velocity (one component), translational temperature, and static pressure of N2 are measured in a supersonic wind tunnel using inverse Raman spectroscopy. For velocity, the technique employs the large Doppler shift exhibited by the molecules when the pump and probe laser beams are counterpropagating (backward scattering). A retrometer system is employed to yield an optical configuration insensitive to mechanical vibration, which has the additional advantage of simultaneously obtaining both the forward and backward scattered spectra. The forward and backward line breadths and their relative Doppler shift can be used to determine the static pressure, translational temperature, and molecular flow velocity. A demonstration of the technique was performed in a continuous airflow supersonic wind tunnel in which data were obtained under the following conditions: (1) free-stream operation at five set Mach number levels over the 2.50-4.63 range; (2) free-stream operation over a range of Reynolds number (at a fixed Mach number) to vary systematically the static pressure; and (3) operation in the flow field of a simple aerodynamic model to assess beam steering effects in traversing the attached shock layer.

Exton, R. J.

Atomic Force Microscope Mediated Chromatography

The atomic force microscope (AFM) is used to inject a sample, provide shear-driven liquid flow over a functionalized substrate, and detect separated components. This is demonstrated using lipophilic dyes and normal phase chromatography. A significant reduction in both size and separation time scales is achieved with a 25-micron-length column scale, and one-second separation times. The approach has general applications to trace chemical and microfluidic analysis. The AFM is now a common tool for ultra-microscopy and nanotechnology. It has also been demonstrated to provide a number of microfluidic functions necessary for miniaturized chromatography. These include injection of sub-femtoliter samples, fluidic switching, and sheardriven pumping. The AFM probe tip can be used to selectively remove surface layers for subsequent microchemical analysis using infrared and tip-enhanced Raman spectroscopy. With its ability to image individual atoms, the AFM is a remarkably sensitive detector that can be used to detect separated components. These diverse functional components of microfluidic manipulation have been combined in this work to demonstrate AFM mediated chromatography. AFM mediated chromatography uses channel-less, shear-driven pumping. This is demonstrated with a thin, aluminum oxide substrate and a non-polar solvent system to separate a mixture of lipophilic dyes. In conventional chromatographic terms, this is analogous to thin-layer chromatography using normal phase alumina substrate with sheardriven pumping provided by the AFM tip-cantilever mechanism. The AFM detection of separated components is accomplished by exploiting the variation in the localized friction of the separated components. The AFM tip-cantilever provides the mechanism for producing shear-induced flows and rapid pumping. Shear-driven chromatography (SDC) is a relatively new concept that overcomes the speed and miniaturization limitations of conventional liquid chromatography. SDC is based on a sliding plate system, consisting of two flat surfaces, one of which has a recessed channel. A fluid flow is produced by axially sliding one plate past another, where the fluid has mechanical shear forces imposed at each point along the channel length. The shear-induced flow rates are very reproducible, and do not have pressure or voltage gradient limitations. SDC opens up a new range of enhanced separation kinetics by permitting the sample confinement with submicron dimensions. Small, highly confined liquid is advantageous for chromatographic separation because the separation rate is known to scale according to the square of the confined sample diameter. In addition, because shear-driven flows are not limited by fluid velocity, shear-driven liquid chromatography may provide up to 100,000 plate efficiency.

Anderson, Mark S.

Double resonance spectroscopy of multiple-photon excited molecules

Multiple infrared photon absorption is a quite general process which molecules can undergo when placed in a high flux of infrared energy, such as the focussed beam of a CO2 laser. In order to understand how this process works, one must be able to follow the evolution of the molecules through their internal states, populated by photon absorption. Double-resonance spectroscopy is the method of a choice for getting at this information. A system pumped by CO2 laser radiation can be examined with a tunable laser probe beam, such as that from a lead-salt diode laser. From such an experiment, one can directly observe Rabi modulation of the absorption lines, determine elementary state-to-state relaxation pathways, and locate higher excited vibrational states. Systems currently under investigation include SF6 and vinyl chloride. In suitable cases, the probe beam can be a tunable visible or UV source, such as a dye laser. Fluorescence spectroscopy can then be used to monitor the transient absorptions produced by multiple-photon excitation. Among the systems which can be examined are biacetyl and glyoxal.

Steinfeld, J. I.

Characterization of devices, circuits, and high-temperature superconductor transmission lines by electro-optic testing

The development of a capability for testing transmission lines, devices, and circuits using the optically-based technique of electro-optics sampling was the goal of this project. Electro-optic network analysis of a high-speed device was demonstrated. The project involved research on all of the facets necessary in order to realize this result, including the discovery of the optimum electronic pulse source, development of an adequate test fixture, improvement of the electro-optic probe tip, and identification of a device which responded at high frequency but did not oscillate in the test fixture. In addition, during the process of investigating patterned high-critical-temperature superconductors, several non-contacting techniques for the determination of the transport properties of high T(sub c) films were developed and implemented. These are a transient, optical pump-probe, time-resolved reflectivity experiment, an impulsive-stimulated Raman scattering experiment, and a terahertz-beam coherent-spectroscopy experiment. The latter technique has enabled us to measure both the complex refractive index of an MgO substrate used for high-T(sub c) films and the complex conductivity of a YBa2Cu3O(7-x) sample. This information was acquired across an extremely wide frequency range: from the microwave to the submillimeter-wave regime. The experiments on the YBCO were conducted without patterning of, or contact to, the thin film. Thus, the need for the more difficult transmission-line experiments was eliminated. Progress in all of these areas was made and is documented in a number of papers. These papers may be found in the section listing the abstracts of the publications that were issued during the course of the research.

Whitaker, John F.

Proposal for the measuring molecular velocity vector with single-pulse coherent Raman spectroscopy

Methods for simultaneous measurements of more than one flow velocity component using coherent Raman spectroscopy are proposed. It is demonstrated that using a kilowatt broad-band probe pulse (3-30 GHz) along with a megawatt narrow-band pump pulse (approximately 100 MHz), coherent Raman signal resulting from a single laser pulse is sufficient to produce a high-resolution Raman spectrum for a velocity measurement.

She, C. Y.

All hard X-ray transient grating spectroscopy

Optical-domain transient grating (TG) spectroscopy is the ideal tool to investigate transport phenomena in gases, liquids and solids, but it is limited to typically micron-size grating periods. Extreme-Ultraviolet TG has represented a major leap forward to access the mesoscopic scales. Hard X-ray TGs open access in principle to the nanoscale. Hard X-ray TGs were recently generated using the Talbot effect and probed by optical pulses, but these hinder exploiting the advantages of the nanoscale gratings. Here, we present an all-X-ray TG study, in which few-femtosecond hard X-ray pulses are used both for excitation and probing. Our experiment was performed on an amorphous film of an FeGd alloy and on a thin silicon single crystal. The results show a manifestation of the TG induced by the X-ray pump and probe pulses in the form of Talbot carpets, as well as temporal evolution of the grating in crystalline silicon showing coherent optical phonons. Ultrafast all-X-ray TG spectroscopy has the potential to study fundamental excitations with femtosecond time resolution and nanometer spatial sensitivity.

Ferrari, Eugenio [Deutsches Elektronen-Synchrotron

Time-dependent phenomena in correlated materials

Understanding time-dependent processes and light-matter interaction in strongly correlated materials, and the interplay between electronic, orbital, vibrational, and spin degrees of freedom, is a cornerstone of condensed matter. These mechanisms can be proven by measuring the response of the systems to time-dependent perturbations. The corresponding time scales are dictated by the way light couples to the different excitations, and how these excitations exchange energy and momentum. Our research advances our understanding of these processes, and the interpretation of different equilibrium and time-resolved spectroscopies. Our project encompasses two main themes: (i) developing and refining computational techniques to study non-equilibrium spectroscopies including non-perturbative effects and (ii) applications to non-equilibrium phenomena. We have developed a new computational approach that works directly in the time domain: by including all the degrees of freedom involved in the scattering process (e.g. electrons, photons, neutrons), we solve the time dependent problem: a faithful numerical simulation of the experiment. By measuring the energy and momentum of the outgoing particles, we can extract information about the energy and momentum absorbed by the system. Prior to our work, people attempting to model and calculate non-equilibrium spectral functions relied on a description of the scattering cross section based on a formulation in the frequency domain, a treatment that is extremely cumbersome and complex. Our technique works in and out of equilibrium and can reproduce spectra by several spectroscopic techniques, such as time-resolved photoemission, neutron scattering, Raman, X-ray spectroscopies (RIXS, Auger, XAS, XMCD), and, by not relying on analytical approximations, yields results that reveal novel overlooked transient mechanisms. These tools provide sorely needed intuition for understanding the phenomenology of strongly correlated materials and will help experimentalists in identifying signatures of relevant excitations in pump-probe experiments, such as those conducted in DOE supported facilities.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Anisotropic Thermal Transport in Quasi-2D Ruddlesden-Popper Hybrid Perovskite Superlattices

Two-dimensional hybrid metal-halide perovskites (2D-MHPs) have emerged as important solution-processed semiconductors with favorable optical and electronic properties for diverse applications in photovoltaics, optoelectronics, and spintronics. The quasi-2D layered structures, featuring large acoustic impedance mismatches between the organic and inorganic sublattices, are expected to result in distinct and anisotropic thermal transport properties along the cross-plane and in-plane directions. Here, we introduce transducer-free vibrational-pump-visible-probe (VPVP) approaches that enable accurate quantification of anisotropic thermal transport properties in various archetypical single-crystalline 2D-MHPs. Specifically, using VPVP spectroscopy and VPVP microscopy, we measure the anisotropic thermal diffusivities of 2D-MHPs with systematically varied Pb-I octahedral layer thicknesses, as well as organic spacer types and lengths, revealing how these structural parameters alter the cross-plane and in-plane thermal transport properties in distinct ways. While diffuse interface scattering plays an important role in dictating cross-plane thermal transport, in-plane thermal transport is primarily determined by phonon transport within interconnected inorganic layers. Density functional theory incorporating four-phonon scatterings provides further insight into the low thermal conductivity and modest thermal conduction anisotropy in 2D-MHPs. Our work demonstrates a new all-optical and noncontact method, which requires minimal sample preparation and allows direct visualization of cross-plane and in-plane thermal transport, potentially compatible with sample environments. The demonstrated VPVP approaches can advance understanding of thermal transport in 2D-MHPs as well as wide-ranging hybrid and polymeric semiconductors beyond 2D-MHPs.

36 MATERIALS SCIENCE

Measuring Temperature By Laser-Induced-Grating Spectroscopy

Temperature computed from speed of laser-induced counter-propagating acoustic waves. Interference between intersecting pumping laser beams gives rise to spatially periodic heating, which in turn, creates oscillating diffraction grating probed by another laser beam. Oscillations in diffracted probe-laser intensity correspond to oscillations of counter-propagating acoustic waves generated by spatially periodic heating.

VanderWal, Randall L.

Laser-Induced Enhancement of Acoustic Mode Quality Factor Revealed by Correlated Single-Particle Optical and Electron Microscopy

Acoustic modes in plasmonic nanostructures provide fundamental insights into their optomechanical behavior at the nanoscale, enabling emerging applications in plasmon-enhanced optomechanics, ultrasensitive sensing, and nanoscale energy transduction. Here we explore the modulation of acoustic phonon dynamics in lithographically fabricated gold nanodisks via laser-induced photothermal annealing. Using a correlated approach that utilizes both single-particle transient extinction spectroscopy and advanced electron microscopy, we directly link nanoscale structural transformations to changes in mechanical properties as probed through the coherence of the excited acoustic modes. Specifically, ultrafast pump–probe microscopy reveals an enhancement in the acoustic mode quality factor of annealed gold nanodisks, indicative of reduced damping and improved vibrational coherence. Structural characterization via scanning electron microscopy and electron backscatter diffraction confirms that photoinduced annealing results in smoother surface morphology and overall enhanced crystallinity. The improved crystalline order reduces defect and crystal boundary scattering, which we suggest as the reason underlying the lower quality factor before annealing. Furthermore, these findings demonstrate that targeted structural engineering at the nanoscale offers a powerful strategy for optimizing the optomechanical performance of plasmonic nanostructures, with broad implications for the design of next-generation nanophotonic and optomechanical systems.

Annealing (metallurgy)

Nanoscale ultrafast lattice modulation with a free-electron laser

Ultrafast optical laser-based techniques have enabled the probing of atomistic processes at their intrinsic temporal scales with femto- and attosecond resolution. However, the long wavelengths of optical lasers have prevented their interrogation and manipulation with nanoscale spatial specificity. Advances in hard X-ray free-electron lasers have enabled progress in developing X-ray transient-grating spectroscopy, a technique that aims to coherently control elementary excitations with nanoscale X-ray standing waves. Thus far, the realization of this technique at the nanoscale has been a challenge. Here we demonstrate X-ray transient-grating spectroscopy with spatial periods of the order of 10 nm via the subfemtosecond synchronization of two hard X-ray pump pulses at a precisely controlled crossing angle. This creates a thermal grating and preferentially excites coherent longitudinal acoustic phonon modes with the transient-grating wavevector. On probing with a third, variably delayed, X-ray pulse with the same photon energy, time-and-wavevector-resolved measurements of the modulation of the induced scattering intensity provide evidence of ballistic thermal transport at nanometre scales. Finally, these results highlight the potential of X-ray transient gratings as a powerful platform for studying nanoscale transport in condensed matter and the coherent control of nanoscale dynamics.

nonlinear optics

Bridging Structural and Chemical Insights: Integrating In Situ Electron Microscopy and X-ray Spectroscopy for Catalysis Research

Environmental transmission electron microscopy probes the local structure, composition, and chemistry of materials under gas environments, while ambient-pressure X-ray photoelectron spectroscopy provides ensemble chemical and electronic structure information in gaseous conditions. Both techniques utilize similar differential pumping schemes to mitigate electron scattering by the gas phase, allowing for unique opportunities to correlate gas–surface interactions across comparable pressure ranges. Their integration has advanced the understanding of various catalytic reactions, including the water–gas-shift reaction, CO oxidation, and surface passivation dynamics. In conclusion, this Mini-Review discusses their methodological advancements, challenges, and potential for further integration with other in situ techniques to address complex catalytic phenomena and guide catalyst design.

36 MATERIALS SCIENCE

Thermoreflectance Detection of Point Defects Resulting from Focused Ion Beam Milling

Focused ion beam (FIB) milling is a commonly used tool for nanoscale material processing, such as for transmission electron microscopy (TEM) sample preparation, or the creation of fiducial markers prior to other processes and measurements. During milling, a high energy ion beam is used to remove material via sputtering. The expelled target material may return to the sample surface however, affecting subsequent measurements. Beam spreading or irradiation due to neutral gallium may also irradiate a larger area than intended. Extensive research has explored the effects of FIB milling on the prepared TEM sample, but few have looked at the effects of milling on the properties of the sample surrounding the milled region. We use multiple pump-probe laser-based techniques (time domain thermoreflectance and steady-state thermoreflectance) to measure the spatial extent of FIB-induced surface/subsurface changes on a series of silicon wafers milled at multiple currents and doses. We supplement these measurements with high-resolution scanning transmission electron microscopy, energy dispersive X-ray spectroscopy, stylus profilometry, and time-of-flight secondary ion mass spectroscopy. We find a sample surface affected by the FIB up to 1 mm from where milling occurred, with a notable dependence on the ion beam current. We also note remarkably high sensitivity to surface defects using the thermoreflectance metrologies, including detection where other measurements failed.

defects