Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Pulsed laser operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Solid-state Laser Development for the in Situ Spectroscopic Europa Explorer Instrument

The in Situ Spectroscopic Europa Explorer (iSEE) instrument is an ultra-compact laser-enabled Raman spectrometer instrument that meets the top-level science requirements for multiple future planetary in situ missions to explore the surface and atmospheric chemistry of planetary bodies across the Solar System. Enceladus, Europa, the Moon, Mars, and Venus are some of the primary targets for future NASA missions to search for extraterrestrial life and potentially habitable environments beyond Earth, further our understanding of the timing and formation of the Solar System and identify potentially viable economic resources such as water and/or valuable metal assets. We report on the advancement and space flight qualification of a compact, robust, solid-state laser operating at 515 nm that serves as the excitation source for the iSEE investigation. The iSEE instrument is being developed under a NASA Maturation of Instruments for Solar System Exploration (MatISSE) program. The iSEE laser is a diode pumped 1030 nm Yb:YAG microchip laser with a second harmonic generator to achieve an output wavelength of 515 nm and coupled to a multi-mode fiber for delivery to the Raman spectrometer probe. The fundamental 1030 nm laser operates at a pulse repetition frequency (PRF) of 1-10 kHz with pulse energy of 95 μJ and ~800 ps pulse width. A 15 mm long Type II KTP crystal is used for second harmonic generation from 1030 nm to 515 nm. The residual fundamental 1030 nm is separated from the 515 nm beam using a pair of dichroic filters. A focusing lens couples the 515 nm beam to the optical fiber to produce an output laser pulse energy of 20 μJ. A custom vacuum fiber feedthrough assembly was designed with two 105 μm core fibers, and two 200 μm core fibers. One fiber is needed for coupling the laser to the iSEE instrument, and the additionally fibers provide redundancy and design flexibility. The laser enclosure is pressurized with >1 atm of clean dry air. The laser has been designed to minimize the size, weight, and power (SWaP) for a lander instrument with minimal resources. The laser will go through environmental testing including vibration and thermal vacuum testing for space flight qualification. Here we discuss the design, trade studies, performance, and environmental qualificationtesting of the iSEE laser.

Solid state laser, Raman spectrometer, visible las

Unseeded Scalar Velocity Measurements for Propulsion Flows

Unseeded molecular tagging methods based on single-photon processes that produce long tag lines (>50 mm) have been recently developed and demonstrated by the Combustion Laser Diagnostics Group (Mechanical Engineering Department) at Vanderbilt University [1,2]. In Ozone Tagging Velocimetry (OTV) a line of ozone (O3) is produced by a single photon from a pulsed narrowband argon fluoride (ArF) excimer laser operating at - 193 nm. After a known time delay, t, the position of the displaced (convected in the flow field) O3 tag line is revealed by photodissociation of O3 and subsequent fluorescence of O2, caused by a pulsed laser sheet from a krypton fluoride (KrF) excimer laser operating at - 248 nm. Intensified CCD camera images of the fluorescence are taken from the initial and final tag line locations thus providing unobtrusive means of establishing a velocity profile in the interrogated flow field. The O3 lines are "written" and subsequently "read" by the following reactions:

Pitz, Robert W.

Performance of the Dragonfly Mass Spectrometer (DraMS) Programmable UV Laser Source Engineering Test Unit (ETU)

NASA’s Dragonfly mission will sample surface materials from multiple sites on Saturn’s largest moon, Titan, in exploration of its potential for prebiotic chemistry. We report on the performance of our short-pulsed UV laser transmitter, developed for the Dragonfly’s on-board Mass Spectrometer (DraMS). Our engineering test unit (ETU) has completed flight qualification and demonstrated its operational science requirements, such that the final flight unit build can begin. The Titan Hydrocarbon Analysis Nanosecond Optical Source (THANOS) ETU laser produces 266 nm laser pulses at programmable energy levels in order to create high resolution laser desorption mass spectrometry (LDMS) measurements. The laser operates in short bursts of 1-50 pulses, each at < 2 ns pulse width, at a 100 Hz repetition rate. Creating a sealed Titanium unit, capable of operation on the extreme environment of Titan’s surface was a major engineering challenge. The laser successfully demonstrated its ability to meet all operational requirements in terms of pulse energy, beam pointing on target and repeatability even after extensive environmental testing.

Matthew W Mullin

Performance of the Dragonfly Mass Spectrometer (DraMS) Programmable UV Laser Source Engineering Test Unit (ETU)

NASA’s Dragonfly mission will sample surface materials from multiple sites on Saturn’s largest moon, Titan, in exploration of its potential for prebiotic chemistry. We report on the performance of our short-pulsed UV laser transmitter, developed for the Dragonfly’s on-board Mass Spectrometer (DraMS). Our engineering test unit (ETU) has completed flight qualification and demonstrated its operational science requirements, such that the final flight unit build can begin. The Titan Hydrocarbon Analysis Nanosecond Optical Source (THANOS) ETU laser produces 266 nm laser pulses at programmable energy levels in order to create high resolution laser desorption mass spectrometry (LDMS) measurements. The laser operates in short bursts of 1-50 pulses, each at < 2 ns pulse width, at a 100 Hz repetition rate. Creating a sealed Titanium unit, capable of operation on the extreme environment of Titan’s surface was a major engineering challenge. The laser successfully demonstrated its ability to meet all operational requirements in terms of pulse energy, beam pointing on target and repeatability even after extensive environmental testing.

Matthew Mullin

Versatile system for ion energy measurements generated by pulsed laser ionization: Insights into electron-ion dynamics

Ion energy distributions generated by pulsed laser interactions with materials are essential for applications ranging from materials science to oncology. Ion energy characterization is particularly important for an emerging mass spectrometry technique called virtual-slit cycloidal mass spectrometry (VS-CMS). The ion energy distribution influences the design and performance of VS-CMS instruments, as well as the efficacy of laser-driven ionization methods in various fields. Several established techniques, including the retarding potential method, time-of-flight (TOF) analysis, and electrostatic energy analyzers, have been employed to measure ion energy distributions. The wide range of ion energies reported highlights the strong dependence of ion energy on laser parameters, target materials, and experimental conditions, as well as the necessity of making independent measurements of the ion energy distribution for specific laser systems and materials. This paper presents the design and characterization of a simple TOF-based apparatus for measuring ion energy distributions from pulsed laser ionization without external fields. This approach minimizes perturbation of electron-ion dynamics and enables simultaneous energy measurements at multiple spatial positions. Here, the apparatus was tested using a nanosecond pulsed Nd:YAG laser operating at 1064 nm, 532 nm, and 266 nm on solid copper sheets at various laser fluences. Simultaneous measurements at different distances provide new insights into ion-electron interactions post-ionization and demonstrate the influence of laser wavelength and fluence on ion energy distributions.

Ion energy

Airborne visible laser optical communication experiment.

A series of optical communication experiments between a high altitude aircraft at 18.3 km (60,000 ft) and a ground station are planned by NASA in the summer of 1972. The basic concept is that an optical tracker and transmitter will be located in each terminal. The aircraft transceiver consists of a 5-mW HeNe laser transmitter with a 30-megabit modulator. The ground station beacon is an argon laser operating at 488 nm. A separate pulsed laser radar is used for initial acquisition. The objective of the experiment is to obtain engineering data on the precision tracking and communication system performance at both terminals. Atmospheric effects on the system performance are of prime importance.

Randall, J. L.

Airborne Visible Laser Optical Communications (AVLOC) experiment

A series of optical communication experiments between a high altitude aircraft at 18.3 km (60,000 ft) and a ground station were conducted by NASA from summer 1972 through winter 1973. The basic system was an optical tracker and transmitter located in each terminal. The aircraft transceiver consisted of a 5-mW HeNe laser transmitter with a 30-megabit modulator. The ground station beacon was an argon laser operating at 488 nm. A separate pulsed laser radar was used for initial acquisition. The objective of the experiment was to obtain engineering data on the precision tracking and communication system performance at both terminals. Atmospheric effects on the system performance was also an experiment objective. The system description, engineering analysis, testing, and flight results are discussed.

Source record

Two-photon laser-induced fluorescence detection of OH

The TP-LIF OH sensor is based on the principle that a molecule having multiple energy states, all of which are bonding, can be pumped into the highest state with the resulting fluorescence being blue-shifted relative to all pumping wavelengths. In this way, one can successfully discriminate against virtually all noise sources in the system using long wavelength blocking filters in conjunction with solar-blind photomultiplier tubes. Thus, these systems tend to be signal limited rather than signal-to-noise limited as is true of the SP-LIF technique as well as other conventional analytical methods. The trick to achieving the above sampling scheme, with high efficiency, is in the use of high photon fluxes of short time duration. Obviously, the latter type of light source is fulfilled nicely by available pulsed lasers. From an operational point of view, however, this laser source needs to be tunable. The latter characteristic permits extremely high selectivity for the detection of a diatomic or simple polyatomic molecule by taking advantage of the high-resolution spectroscopic features of these type species.

Davis, D. D.

A method of atmospheric density measurements during space shuttle entry using ultraviolet-laser Rayleigh scattering

An analytical study and its experimental verification are described which show the performance capabilities and the hardware requirements of a method for measuring atmospheric density along the Space Shuttle flightpath during entry. Using onboard instrumentation, the technique relies on Rayleigh scattering of light from a pulsed ArF excimer laser operating at a wavelength of 193 nm. The method is shown to be capable of providing density measurements with an uncertainty of less than 1 percent and with a spatial resolution along the flightpath of 1 km, over an altitude range from 50 to 90 km. Experimental verification of the signal linearity and the expected signal-to-noise ratios is demonstrated in a simulation facility at conditions that duplicate the signal levels of the flight environment.

Mckenzie, Robert L.

Synthesis, characterization and evaluation of CO-oxidation catalysts for high repetition rate CO2 TEA lasers

An extremely active class of noble metal catalysts supported on titania was developed and fabricated at Hughes for the recombination of oxygen (O2) and carbon monoxide (CO) in closed-cycle CO2 TEA lasers. The incipient wetness technique was used to impregnate titania and alumina pellets with precious metals including platinum and palladium. In particular, the addition of cerium (used as an oxygen storage promoter) produced an extremely active Pt/Ce/TiO2 catalyst. By comparison, the complementary Pt/Ce/ gamma-Al2O3 catalyst was considerably less active. In general, chloride-free catalyst precursors proved critical in obtaining an active catalyst while also providing uniform metal distributions throughout the support structure. Detailed characterization of the Pt/Ce/TiO2 catalyst demonstrated uniform dendritic crystal growth of the metals throughout the support. Electron spectroscopy for Chemical Analysis (ESCA) analysis was used to characterize the oxidation states of Pt, Ce and Ti. The performance of the catalysts was evaluated with an integral flow reactor system incorporating real time analysis of O2 and CO. With this system, the transient and steady-state behavior of the catalysts were evaluated. The kinetic evaluation was complemented by tests in a compact, closed-cycle Hughes CO2 TEA laser operating at a pulse repetition rate of 100 Hz with a catalyst temperature of 75 to 95 C. The Pt/Ce/TiO2 catalyst was compatible with a C(13)O(16)2 gas fill.

Moser, Thomas P.

The effect of H2O and pretreatment on the activity of a Pt/SnO2 catalyst

CO oxidation catalysts with high activity at 25 C to 100 C are important for long-life, closed-cycle operation of pulsed CO2 lasers. A reductive pretreatment with either CO or H2 has been shown to significantly enhance the activity of a commercially available platinum on tin (IV) oxide (Pt/SnO2) catalyst relative to an oxidative or inert pretreatment or no pretreatment. Pretreatment at temperatures of 175 C and above causes an initial dip in the observed CO2 yield before the steady-state yield is attained. This dip has been found to be caused by dehydration of the catalyst during pretreatment and is readily eliminated by humidifying the catalyst or the reaction gas mixture. It is hypothesized that the effect of humidification is to increase the concentration of OH groups on the catalyst surface which play a role in the reaction mechanism.

Vannorman, John D.

Stereo viewing 3-component, planar PIV utilizing fuzzy inference

An all electronic 3-D Digital Particle Image Velocimetry (DPIV) system has been developed for use in high velocity (supersonic) flows. Two high resolution CCD cameras mounted in a stereo viewing configuration are used to determine the out-of-plane velocity component from the difference of the in-plane velocity measurements. Double exposure image frames are acquired and Fuzzy inference techniques are used to maximize the validity of the velocity estimates obtained from the auto-correlation analysis. The CCD cameras are tilted relative to their respective lens axes to satisfy Scheimpflug's condition. Tilting the camera film plane ensures that the entire image plane is in focus. Perspective distortion still results, but can be corrected by proper calibration of the optical system. A calibration fixture is used to determine the experimental setup parameters and to assess the accuracy to which the z-plane displacements can be estimated. The details of the calibration fixture and procedure are discussed in the text. A pair of pulsed Nd:YAG lasers operating at 532 nm are used to illuminate the seeded flow from a convergent nozzle operated in an underexpanded condition. The light sheet was oriented perpendicular to the nozzle flow, yielding planar cross-sections of the 3-component velocity field at several axial stations. The key features of the supersonic jet are readily observed in the cross-plane vector plots.

Wernet, Mark P.

Development of Laser, Detector, and Receiver Systems for an Atmospheric CO2 Lidar Profiling System

A ground-based Differential Absorption Lidar (DIAL) is being developed with the capability to measure range-resolved and column amounts of atmospheric CO2. This system is also capable of providing high-resolution aerosol profiles and cloud distributions. It is being developed as part of the NASA Earth Science Technology Office s Instrument Incubator Program. This three year program involves the design, development, evaluation, and fielding of a ground-based CO2 profiling system. At the end of a three-year development this instrument is expected to be capable of making measurements in the lower troposphere and boundary layer where the sources and sinks of CO2 are located. It will be a valuable tool in the validation of NASA Orbiting Carbon Observatory (OCO) measurements of column CO2 and suitable for deployment in the North American Carbon Program (NACP) regional intensive field campaigns. The system can also be used as a test-bed for the evaluation of lidar technologies for space-application. This DIAL system leverages 2-micron laser technology developed under a number of NASA programs to develop new solid-state laser technology that provides high pulse energy, tunable, wavelength-stabilized, and double-pulsed lasers that are operable over pre-selected temperature insensitive strong CO2 absorption lines suitable for profiling of lower tropospheric CO2. It also incorporates new high quantum efficiency, high gain, and relatively low noise phototransistors, and a new receiver/signal processor system to achieve high precision DIAL measurements.

Ismail, Syed

Development and Evaluation of a High Sensitivity DIAL System for Profiling Atmospheric CO2

A ground-based 2-micron Differential Absorption Lidar (DIAL) CO2 profiling system for atmospheric boundary layer studies and validation of space-based CO2 sensors is being developed and tested at NASA Langley Research Center as part of the NASA Instrument Incubator Program. To capture the variability of CO2 in the lower troposphere a precision of 1-2 ppm of CO2 (less than 0.5%) with 0.5 to 1 km vertical resolution from near surface to free troposphere (4-5 km) is one of the goals of this program. In addition, a 1% (3 ppm) absolute accuracy with a 1 km resolution over 0.5 km to free troposphere (4-5 km) is also a goal of the program. This DIAL system leverages 2-micron laser technology developed under NASA's Laser Risk Reduction Program (LRRP) and other NASA programs to develop new solid-state laser technology that provides high pulse energy, tunable, wavelength-stabilized, and double-pulsed lasers that are operable over pre-selected temperature insensitive strong CO2 absorption lines suitable for profiling of lower tropospheric CO2. It also incorporates new high quantum efficiency, high gain, and relatively low noise phototransistors, and a new receiver/signal processor system to achieve high precision DIAL measurements. This presentation describes the capabilities of this system for atmospheric CO2 and aerosol profiling. Examples of atmospheric measurements in the lidar and DIAL mode will be presented.

Ismail, Syed

High Spectral Resolution Lidar Measurements Using an I2 Absorption Filter

The University of Wisconsin high spectral resolution lidar (HSRL) measures optical properties of the atmosphere by separating the Doppler-broadened molecular backscatter return from the unbroadened aerosol return. The HSRL was modified to use an I2 absorption cell The modified HSRL transmitter uses a continuously pumped, Q-switched, injection seeded, frequency doubled Nd:YAG laser operating at a 4 kHz pulse repetition rate. This laser is tunable over a 124 GHz frequency range by temperature tuning the seed laser under computer control.

Eloranta, E. W.

Large mode radius resonators

Resonator configurations permitting operation with large mode radius while maintaining good transverse mode discrimination are considered. Stable resonators incorporating an intracavity telescope and unstable resonator geometries utilizing an output coupler with a Gaussian reflectivity profile are shown to enable large radius single mode laser operation. Results of heterodyne studies of pulsed CO2 lasers with large (11mm e sup-2 radius) fundamental mode sizes are presented demonstrating minimal frequency sweeping in accordance with the theory of laser-induced medium perturbations.

Harris, Michael R.

Cavity-Dumped Communication Laser Design

Cavity-dumped lasers have significant advantages over more conventional Q-switched lasers for high-rate operation with pulse position modulation communications, including the ability to emit laser pulses at 1- to 10-megahertz rates, with pulse widths of 0.5 to 5 nanoseconds. A major advantage of cavity dumping is the potential to vary the cavity output percentage from pulse to pulse, maintaining the remainder of the energy in reserve for the next pulse. This article presents the results of a simplified cavity-dumped laser model, establishing the requirements for cavity efficiency and projecting the ultimate laser efficiency attainable in normal operation. In addition, a method of reducing or eliminating laser dead time is suggested that could significantly enhance communication capacity. The design of a laboratory demonstration laser is presented with estimates of required cavity efficiency and demonstration potential.

Roberts, W. T.

Exploratory laser experiments

Experiments are described which were undertaken to explore the application of various dye laser methods for generating laser pulses which could be tuned over H2O absorption lines in the visible and near infrared. Specific topics discussed include: operation of a long pulse dye laser with a tunable, narrow band output at high energies near the 5915 A water vapor absorption bands; assembly and operation of a short duration dye laser near the 5915 A water vapor absorption bands; construction of a dye laser to be pumped to operate in the red and near infrared; and preliminary studies of the beam divergence of the output of the a laser-pumped system. Results are summarized.

Source record