Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Bridging Power System Protection Gaps with Data-driven Approaches

Protection is a critical function in power systems to avoid equipment damage, maintain personnel safety, and support system reliability. However, current protective relay technology cannot adequately protect equipment and personnel from effects of some events; these deficiencies are termed protection gaps. In this research, a data-driven approach is proposed to complement traditional protection technology and distinguish fault conditions from transients caused by normal operations. A convolutional neural network (CNN) based fault detection approach is implemented to achieve data translation invariance of the time-series input data. As a result, the data-driven method can accurately detect system faults despite variation and noise in the input data. In addition, using the CNN–based method avoids the complicated manual feature extraction procedure required by many traditional data-driven methods. The effectiveness of the proposed approach is tested on four kinds of protection gaps: high impedance faults, transformer/generator inter-turn faults, distribution system PV circuit faults, and the mis-operation situations of Zone 3 line protection relays operating under system stress. Finally, a transfer learning method is also proposed to address the common issue of data-driven methods for which real-world training data are scarce. Extensive study results demonstrate that the proposed approach can accurately bridge power system protection gaps.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Environmental Protection Coating System for Refractory Metal Alloys (EPCS for RMAs)

As part of ARPA-E’s Ultra High Temperature Impervious Materials Advancing Turbine Efficiency (UITIMATE) program, this project aims to develop an environmental protection coating system (EPCS) for refractory metal alloys (RMAs) – which will provide radical improvement in long term protection for ultra-high temperature refractory metal components in harsh gas-turbine environments. The drive for higher fuel efficiency and higher core power of gas turbines used in electric power generation and in aircraft propulsion requires higher peak operation temperatures. The temperature capability of state-of-the-art materials cannot meet the new requirements. Refractory metal alloys have desirable capabilities for achieving the required peak temperatures, but most of them are subject to oxidation in the gas turbine environment. Thus, there is a strong need to develop novel environmental protective coatings that enable the refractory metals to operate in an ultra-high temperature engine environment. This project is composed of four major technical innovations that can provide a potentially transformational solution in providing environmental protection for refractory metal alloys over a wide range of temperature. 1) Multi-layer self-healing environmental barrier coating (EBC) that provides protection against combustion gas environment. 2) Oxidation resistant diffusion barrier (DB) on the alloy surface to enhance coating stability. 3) Synergistic integration of the multi-layer self-healing EBC with the diffusion barrier to extend coating life. 4) Guidance of physics-based modeling to accelerate coating development and optimization. Our team has successfully developed a multi-layer self-healing environmental protection coating system (EPCS) that can provide oxidation protection for commercially available molybdenum based refractory metal alloys over a wide temperature range of up to 1600 °C for fuel-efficient gas turbine applications. The team also developed a multi-layer high temperature coating design tool to accelerate coating development and optimization based on physics-based modeling. The team also engaged RTX business unite, notable Pratt and Whitney, for future commercialization of this technology. The successful completion of this Phase I effort led to the selection of performing Phase II of the program. In Phase II, the team plans to apply the EPCS in the protection of a newly discovered molybdenum-based metal alloy which has the potential of superior high temperature properties to the commercial products. Th coating will be evaluated under test conditions and environment that mimic gas turbine operation.

36 MATERIALS SCIENCE↗

DOE 10658 Project Sensitivity-Driven Wide Area Protection (SWAP) Coordination Tools for IBRs

Utilities have seen a rapid increase in solar, wind, and battery energy storage systems that interconnect to their electric system through inverters. Inverter-Based Resources (IBRs) have fault current characteristics that are unlike the fault current response of traditional rotating-machine-based generators, which is well-known and repeatable. IBR’s non-traditional fault current behavior is due to the IBR control scheme, which is configured to provide a clean AC output but also protects the inverter’s sensitive power electronics devices from damage from conditions such as overcurrent. This results in a low fault current magnitude, low or no negative sequence current injection, the variability of sequence component currents, the variability of voltage with respect to current angles, and the lack of inertia. The control scheme also results in a fault current response that can vary between manufacturers and between models of the same manufacturer. High penetration of IBRs can adversely affect the protection schemes applied in areas with high penetration of IBRs. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems. This is mainly because the existing protection elements and practices have been designed based on the fault current response of conventional rotating machines. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. Instead of focusing on one issue, this report looks broadly at all the challenges that system protection has experienced with high penetration of IBRs. Based on the IBR response from various utilities during real fault events and gathering perspectives from different utility SMEs via questionnaire, the report summarizes the gathered data and internal experiences.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Polymorphic Membrane Protein G Has a Neutral Effect and the Plasmid Glycoprotein 3 an Antagonistic Effect on the Ability of the Major Outer Membrane Protein to Elicit Protective Immune Responses against a Chlamydia muridarum Respiratory Challenge

Chlamydia trachomatis is the most common bacterial sexually transmitted pathogen. The number of chlamydial infections continuous to increase and there is an urgent need for a safe and efficacious vaccine. To assess the ability of the Chlamydia muridarum polymorphic membrane protein G (PmpG) and the plasmid glycoprotein 3 (Pgp3) as single antigens, and in combination with the major outer-membrane protein (MOMP) to induce protection, BALB/c mice were immunized utilizing CpG-1826 and Montanide ISA 720 VG as adjuvants. Following vaccination with MOMP, significant humoral and cell-mediated immune responses were observed, while immunization with PmpG, or Pgp3, elicited weaker immune responses. Weaker immune responses were induced with MOMP+Pgp3 compared with MOMP alone. Following the intranasal challenge with C. muridarum, mice vaccinated with MOMP showed robust protection against body-weight loss, inflammatory responses in the lungs and number of Chlamydia recovered from the lungs. PmpG and Pgp3 elicited weaker protective responses. Mice immunized with MOMP+PmpG, were no better protected than animals vaccinated with MOMP only, while Pgp3 antagonized the protection elicited by MOMP. In conclusion, PmpG and Pgp3 elicited limited protective immune responses in mice against a respiratory challenge with C. muridarum and failed to enhance the protection induced by MOMP alone. The virulence of Pgp3 may result from its antagonistic effect on the immune protection induced by MOMP.

60 APPLIED LIFE SCIENCES↗

Evaluation of Cross-Protection of African Swine Fever Vaccine ASFV-G-ΔI177L Between ASFV Biotypes

Background/Objectives: Vaccine development for the prevention of ASF has been very challenging due to the extensive genetic and largely unknown antigenic diversity. Inactivated vaccines, using different inactivation methods and a variety of adjuvants, have been consistently inefficacious. Historically, animals recovering from an infection with an attenuated virus became protected from the development of a clinical disease caused by an antigenically related strain. Therefore, immunization of susceptible animals with attenuathe ted virus strains has become a common method of vaccination with the first two commercially available vaccines based on recombinant live-attenuated viruses (LAVs). An important limitation is that the efficacy of the LAV is restricted to those strains that are antigenically related and, in most cases, only provide protection against homologous strains. Due to the unknown antigenic heterogeneity among all ASFV field isolates, the development of broad-spectrum vaccines is a challenge. Besides the anecdotal data, there is not a large amount of information describing patterns of cross-protection between different ASFV strains. Methods: We evaluated the cross-protection induced by the ASFV live-attenuated vaccine ASFV-G-ΔI177L against different biotypes of ASFV and compared their genomic sequences to determine potential genetic mutations that could cause the lack of cross-protection. Results: Results presented here demonstrate different patterns of protection when ASFV-G-ΔI177L vaccinated pigs were challenged with six different ASFV field isolates belonging to different biotypes. Conclusions: The presence of cross-protection cannot be predicted solely by the classical methodology for genotyping-based B646L ORF only. Biotyping, considering the entire virus proteome, appears to be a more promising prediction tool, although additional gathering of experimental data will be necessary to fully validate it; until then, the presence of cross-protection needs to be confirmed in efficacy trials challenging vaccinated animals.

Immunology↗

New data-driven approach to bridging power system protection gaps with deep learning

Protection is a critical function in power systems to avoid equipment damage, maintain personnel safety, and support system reliability. However, current protective relay technology cannot adequately protect equipment and personnel from effects of some events; these deficiencies are termed protection gaps. In this paper, a data-driven approach is proposed to complement traditional protection technology and distinguish fault conditions from transients caused by normal operations. A combined convolutional neural network and long short-term memory (CNN-LSTM) network is implemented to achieve data translation invariance and capture the temporal correlation of the time-series input data. As a result, the data-driven method can accurately detect system faults despite variation and noise in the input data. In addition, using the CNN-LSTM--based method avoids the complicated, manual feature extraction procedure required by many traditional data-driven methods. The effectiveness of the proposed approach is tested on two kinds of protection gaps: high-impedance faults and transformer inter-turn faults. Lastly, a transfer learning method is also proposed to address the common issue of data-driven methods for which real-world training data are scarce. Extensive study results demonstrate that the proposed approach can accurately bridge power system protection gaps.

42 ENGINEERING↗

Design of Zone-Based Hierarchical Protection System for 100% Renewable Microgrids

Design of a reliable and secure protection system for a 100% renewable microgrid with only inverter-based resources (IBRs), is quite challenging. Most of the existing protection schemes in the state-of-the-art are suitable for microgrids with mixed-type of distributed energy resources (DERs) that covers both rotating machine-based DERs as well as IBR-based DERs, where the fault current level is moderately high. Due to drastic reduction in fault current level based on mode of operation and the variation of the low fault current level based on the operating level of the IBRs, the existing protection schemes face critical challenges, in case of a 100% renewable microgrid. This article proposes a zone-based hierarchical protection scheme that partitions a microgrid into various zones-of-protection and assigns speed-based hierarchical protection schemes in order to address the fundamental challenges of such microgrids. The performance of the proposed scheme is evaluated using time-domain simulation study on a microgrid test system. The results corroborates that the proposed hierarchical zone-based protection scheme exhibits enhanced reliability, security and dependability while tested with various fault cases (fault types, locations, and impedances), and non-fault cases during both grid-tied and islanded mode.

grid-forming inverter↗

Doubling protected land area may be inefficient at preserving the extent of undeveloped land and could cause substantial regional shifts in land use

Abstract Projection of land use and land‐cover change is highly uncertain yet drives critical estimates of carbon emissions, climate change, and food and bioenergy production. We use new, spatially explicit land availability data in conjunction with a model sensitivity analysis to estimate the effects of additional land protection on land use and land cover. The land availability data include protected land and agricultural suitability and is incorporated into the Moirai land data system for initializing the Global Change Analysis Model. Overall, decreasing land availability is relatively inefficient at preserving undeveloped land while having considerable regional land‐use impacts. Current amounts of protected area have little effect on land and crop production estimates, but including the spatial distribution of unsuitable (i.e., unavailable) land dramatically shifts bioenergy production from high northern latitudes to the rest of the world, compared with uniform availability. This highlights the importance of spatial heterogeneity in understanding and managing land change. Approximately doubling the current protected area to emulate a 30% protected area target may avoid land conversion by 2050 of less than half the newly protected extent while reducing bioenergy feedstock land by 10.4% and cropland and grazed pasture by over 3%. Regional bioenergy land may be reduced (increased) by up to 46% (36%), cropland reduced by up to 61%, pasture reduced by up to 100%, and harvested forest reduced by up to 35%. Only a few regions show notable gains in some undeveloped land types of up to 36%. Half of the regions can reach the target using only unsuitable land, which would minimize impacts on agriculture but may not meet conservation goals. Rather than focusing on an area target, a more robust approach may be to carefully select newly protected land to meet well‐defined conservation goals while minimizing impacts to agriculture.

54 ENVIRONMENTAL SCIENCES↗

Utility Experience with Inverter Based Resource Impacts on Transmission Protection

High penetration of inverter-based resources (IBR) can adversely affect the transmission protection schemes in the area. With the proliferation of IBRs, utilities are finding out that conventional protection schemes are not adequately equipped to protect the electric systems because the existing system has been designed based on the fault current response of conventional rotating-machine-based generators. In several cases, the available literature does not provide any clear solution for the issues when the protection scheme does not operate properly near IBRs. This report identifies various protection challenges due to IBRs that industry is facing, from the utility perspective. It includes a broad review of all challenges that system protection has experienced so far with high penetration of IBRs. Key issues have been identified based on a survey of different utility protection engineers. Finally, fault event recordings are shown to demonstrate some actual cases of mis-operations of relays near IBRs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design of Zone-Based Hierarchical Protection System for 100% Renewable Microgrids: Preprint

Design of a reliable and secure protection system for a 100% renewable microgrid with only inverter-based resources (IBRs), is quite challenging. Most of the existing protection schemes in the state-of-the-art are suitable for microgrids with mixed-type of distributed energy resources (DERs) that covers both rotating machine-based DERs as well as IBR-based DERs, where the fault current level is moderately high. Due to drastic reduction in fault current level based on mode of operation and the variation of the low fault current level based on the operating level of the IBRs, the existing protection schemes face critical challenges, in case of a 100% renewable microgrid. This article proposes a zone-based hierarchical protection scheme that partitions a microgrid into various zones-of-protection and assigns speed-based hierarchical protection schemes in order to address the fundamental challenges of such microgrids. The performance of the proposed scheme is evaluated using time-domain simulation study on a microgrid test system. The results corroborates that the proposed hierarchical zone-based protection scheme exhibits enhanced reliability, security and dependability while tested with various fault cases (fault types, locations, and impedances), and non-fault cases during both grid-tied and islanded mode.

grid-forming inverter↗

Persistence of bacterial-mediated anti-rotifer protection in preliminary outdoor cultivation trial for Microchloropsis salina

Outdoor algal cultivation systems are susceptible to a wide variety of deleterious species. In previously published studies, we observed protection using microbial consortia at laboratory scale cultures; Microchloropsis salina in the presence of microbial consortia were protected from grazing from the marine rotifer, Brachionus plicatilis. Our objective for the present work was to determine if this protection conferred by microbial consortia in controlled laboratory experiments would persist in an open, outdoor multi-liter cultivation system. We found that algal protection did persist as evidenced by the presence of fewer motile rotifers and decreased rotifer-associated egg counts for the consortia-treated outdoor cultures. Due to the low temperature and light conditions that reduced growth of the algae outdoors, we performed an indoor laboratory assay which also confirmed the persistence of algal protection. Lastly, the lower numbers of motile rotifers and fewer rotifer-associated eggs in the consortia-treated algal cultures suggests a possible protective mechanism by the consortia through interfering with the rotifer lifecycle or reproduction. Finally, these initial results support the possibility that low cost, prophylactic treatments with microbial consortia can protect algae from deleterious species in outdoor cultivation systems.

59 BASIC BIOLOGICAL SCIENCES↗

Background Information on the Protection Requirements in IEEE Std 1547-2018

As the DER penetration level has risen significantly in recent times, parameter settings and configuration of installed DERs are having direct impact on local electric distribution utilities as well as bulk power systems during normal and abnormal grid conditions. On the other hand, all grid-connected DERs in the United States of America must conform to the interconnection requirements prescribed in the IEEE Std 1547-2018. Because of these reasons, it is crucial to understand the expected DER performance during abnormal grid conditions considering the requirements of the IEEE Std 1547-2018. The aim of this document is twofold: (1) to summarize requirements in IEEE Std 1547-2018 having direct implications in distribution network protection, and (2) to provide the reader with knowledge and information that will be required for users to apply the requirements specified. Since the focus of this document is on distribution network protection in the presence of DERs, it is assumed that the readers have basic understanding of distribution network protection as well as working principles of DERs. This document starts with a brief introduction on protection systems for distribution network followed by a discussion on the impact of DER on the protection systems. Current practices to provide network protection in the presence of DER is briefly discussed. The document then explores the DER performance requirements in IEEE Std. 1547-2018; especially on those related to distribution network protection. Section 6.1 in IEEE Std. 1547-2018 provides an overview of capabilities and control requirements for DER under abnormal operating conditions. This section also introduces abnormal operating performance categories I, II, III. The DER response to various types of faults and grid conditions such as short-circuit faults and open phase conditions are discussed in section 6.2 in the standard while requirements for coordination with the Area EPS reclosing scheme are provided in section 6.3. Section 6.4 in the IEEE Std 1547-2018 specifies requirements for mandatory voltage tripping and ride-through requirements during low and high voltage disturbances and section 6.5 specifies similar requirements for low and high frequency disturbances. IEEE Std. 1547 requires that the conformance of the DERs to IEEE Std 1547-2018 requirements should be verified in accordance with IEEE Std. 1547. 1. There are several parameters and settings of DERs that need to be properly selected for reliable operation during abnormal grid condition while applying the requirements of IEEE Std 1547-2018. Key decisions for proper selections of parameter and settings are: 1. Determination of required DER abnormal operating performance category, 2. Determination of DER response (shall trip) to abnormal voltages and 3. Determination of DER response (shall trip) to abnormal frequency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Systems of Radiological Protection for Ionizing and Non-Ionizing Radiation

This paper summarizes the presentations and panel discussion held at Plenary Session 1 of the 16th IRPA International Congress/69th Health Physics Society Annual Meeting, in Orlando, FL, in July 2024. Plenary Session 1 discussed the basics of the systems of radiological protection (RP) for ionizing radiation (IR) and non-ionizing radiation (NIR) and included five presentations and a panel discussion. Rodney Croft, Chair of the International Commission on Non-Ionizing Radiation Protection (ICNIRP), delivered the first presentation. Croft introduced the System of RP for NIR and provided an overview of ICNIRP’s coverage and current areas of work. Werner Rühm, Chair of the International Commission on Radiological Protection (ICRP), delivered the second presentation. He gave an overview of the System of RP for IR and covered the key principles of justification, optimization, and dose limitation, including the current plans of ICRP toward the envisaged revision of the System of RP. The third speaker, Sigurður Magnús Magnússon, from the International Radiation Protection Association (IRPA), provided the perspective of the RP professionals on the development of the Systems of RP for IR and NIR. Emilie van Deventer, from the World Health Organization (WHO), presented WHO’s views of both Systems of RP and discussed the relevant current activities of WHO with regard to IR and NIR. Kathryn Higley, President of the National Council on Radiation Protection and Measurements (NCRP), delivered the final presentation. Higley outlined the history of NCRP, the differences between ICRP and NCRP, and discussed the role of the NCRP in the System of RP, including NCRP’s role to analyze mechanisms of interaction of NIR with biological systems, including humans. The session concluded with a fruitful panel discussion, where the audience had the opportunity to ask the five invited speakers questions.

61 RADIATION PROTECTION AND DOSIMETRY↗

National variability in Americans’ COVID-19 protective behaviors: Implications for vaccine roll-out

Protective behaviors such as mask wearing and physical distancing are critical to slow the spread of COVID-19, even in the context of vaccine scale-up. Understanding the variation in self-reported COVID-19 protective behaviors is critical to developing public health messaging. The purpose of the study is to provide nationally representative estimates of five self-reported COVID-19 protective behaviors and correlates of such behaviors. In this cross-sectional survey study of US adults, surveys were administered via internet and telephone. Adults were surveyed from April 30-May 4, 2020, a time of peaking COVID-19 incidence within the US. Participants were recruited from the probability-based AmeriSpeak® national panel. Brief surveys were completed by 994 adults, with 73.0% of respondents reported mask wearing, 82.7% reported physical distancing, 75.1% reported crowd avoidance, 89.8% reported increased hand-washing, and 7.7% reported having prior COVID-19 testing. Multivariate analysis (p critical value .05) indicates that women were more likely to report protective behaviors than men, as were those over age 60. Respondents who self-identified as having low incomes, histories of criminal justice involvement, and Republican Party affiliation, were less likely to report four protective behaviors, though Republicans and individuals with criminal justice histories were more likely to report having received COVID-19 testing. The majority of Americans engaged in COVID-19 protective behaviors, with low-income Americans, those with histories of criminal justice involvement, and self-identified Republicans less likely to engage in these preventive behaviors. Culturally competent public health messaging and interventions might focus on these latter groups to prevent future infections. These findings will remain highly relevant even with vaccines widely available, given the complementarities between vaccines and protective behaviors, as well as the many challenges in delivering vaccines.

60 APPLIED LIFE SCIENCES↗

A Risk-Informed Performance-Based Methodology to Manage Fire Protection Systems in Nuclear Facilities

Fire protection systems (FPSs) and features are installed in U.S. Department of Energy (DOE) Hazard Category 1, 2, or 3 nuclear facilities to protect property (maximum possible fire loss thresholds), life, and nuclear safety (i.e., structures, systems, and components). These FPSs and features are designed and maintained in accordance with the prescriptive guidance provided in applicable building codes and National Fire Protection Association codes and standards. Management, operations, and maintenance activities of FPSs involve significant effort. A DOE facility’s documented safety analysis or other safety basis document could also rely on FPSs to provide either a safety significant or safety class function to mitigate fire hazards and minimize radiological consequences. In some cases, the designation of safety significant or safety class may be determined to provide a layer of defense-in-depth to minimize nuclear safety risks independent of the fire risk. DOE standards allow the use of performance-based design alternatives developed by the fire industry but do not consider the defense-in-depth layers of protection provided in DOE facilities to prevent or mitigate the risks associated with unintended release of radioactive materials into the environment. Pacific Northwest National Laboratory developed a decision-making methodology tailored for DOE non-reactor nuclear facilities to manage FPSs and features by integrating nuclear safety risk insights into a performance-based analysis. This risk-informed, performance-based (RIPB) methodology can be used to provide the technical basis for classifying an FPS as safety class and safety significant, tailoring administrative controls (e.g., technical safety requirements), and ranking the importance of FPSs to prioritize maintenance, upgrades, and replacement activities. The RIPB methodology is a graded approach to inform DOE facility owners and Fire Protection Program managers of the most risk-significant FPSs and equipment, and those systems would be cost-beneficial to relax rigor if there is a need to re-design the FPS coverage or deviate from DOE and National Fire Protection Association standards for those systems that would be less significant. This paper describes the framework used to develop the RIPB methodology and the outcome of implementing this methodology in a use-case nuclear facility. This paper also discusses the impact to DOE policies and standards and the safety margins and defense-in-depth measures credited in nuclear safety assessments in a facility’s documented safety analysis and the benefits of implementing an RIPB methodology in lieu of a prescriptive method to comply with fire protection requirements.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effect of GPS Manipulation to Traditional and Next Generation Relay Protection (Final Report)

This project’s objective is to test the effect of GPS timing variations on relay protection algorithms to determine vulnerabilities and the associated hazards to the electric grid. This will focus on time domain protection which utilizes traveling waves measured on the transmission lines to detect the fault within a tower span. This requires the use of GPS to sync the two substations and can be vulnerable to GPS manipulation. However, the effects of GPS manipulation are not a commonly known risk. Therefore, this LDRD will address the risks of GPS manipulation for on a new protective relay technology that has the potential to change protective relaying. For time domain protection a GPS resilient architecture was implemented and tested for time domain protective relays through a direct serial fiber connection between the two relays. This allows for one relay to be the master and provide synchronization outside of timestamp for traveling wave protection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cathodic Protection Modeling for Hanford Underground Double-Shell Tank Farms

Hanford stores millions of gallons of radioactive and chemically hazardous waste from the production of weapon materials in tank farms consisting of underground carbon-steel storage tanks surrounded by reinforced concrete. Six of these Hanford tank farms use double-shell storage tanks (DSTs). The DST farms were constructed from 1968 to 1986 with a planned 40–50 year design life, so some are already operating beyond their initial life expectancy. Ultrasonic testing (UT) has indicated significant thinning on the bottom of the secondary (outer) liner of these tanks, believed to arise from groundwater intrusion driving concrete side corrosion. There is no direct access to the steel/concrete interface between the tank and the concrete pad, making it difficult to apply a chemical-based mitigation strategy or to conduct repairs, but cathodic protection (CP) is a possible method to inhibit further concrete-side corrosion. Hanford already uses CP to protect below grade steel piping within the tank farms and connected to the tanks, but this system was not designed to protect the tank bottoms. CP design must account for the structures surrounding the DSTs, including the steel reinforcing bars (rebar) within the concrete pad and vault, various process lines, and the existing CP system. In this study, finite element analysis (FEA) modeling was carried out to simulate CP protection of 1) a single tank and CP anode to develop options for modeling the rebar and to compare to a simpler circuit model and 2) the entire Hanford AN tank farm as a representative example consisting of seven tanks, associated piping, and both existing and new CP anodes. Both circuit and FEA models predict that significant protective current could be delivered to the bottoms of the tanks with the addition of tank-protection anodes below the depth of the tanks. Simulations with only the existing pipe-protection anodes active confirmed that only a very small current to the tank bottoms is predicted under present conditions. Multiple simplified representations of the dome and wall rebar were tested to reduce the computational complexity of the tank-farm simulations, resulting in modeling the rebar as edge elements with a prescribed effective circumference that matches the real rebar surface area. The geometry of the rebar is also simplified into horizontal hoops around the tank walls and radial rebar over the dome with increased effective circumference to retain the target surface area. This simplification was found to greatly reduce the complexity and solution time of the models without large changes in current distributions, especially to the tank bottom. A range of values were tested for model parameters such as soil and concrete resistivities and polarization resistance to investigate their impact on the current and electric potential distributions. Depending on the parameters used, FEA simulations predict some risk of overprotection, particularly on the piping system; since overprotection can also lead to surface damage associated with hydrogen gas generation at the interface (e.g. hydrogen embrittlement or damage to coatings), this needs to be considered when refining the design of the new CP system. Comparison between the FEA models and the circuit model representation demonstrated that the circuit model could not match the predicted FEA current distribution, even when using the exact same surface areas. This discrepancy appeared to be at least partly attributable to the impact of the relative positions of the tank components and anodes to each other and to the ground surface. The FEA model accounts for the relative positions since it solves the governing equations in three dimensions, but the circuit model cannot account for the positioning. In particular, the circuit model underpredicts the current to the tank bottom and overpredicts the current to the dome compared to FEA for the baseline geometry. The FEA models omitted the electrically isolated rebar in the bottom concrete slab. However, a circuit based stray current model estimated that only 2.1% of the total current through the slab would stray into the rebar, corresponding to ~0.21 A for a target current density of 2 mA/ft2 to the tank bottom. The estimated corrosion driven by this amount of stray current is predicted to yield a lifetime of >400 years for the minimum rebar diameter, assuming an acceptable cross-section area loss of 10%.

d'Entremont, Anna [Savannah River National Laborat↗

Protection layers for metal anodes

A protection layer is formed on a highly-reactive substantially-pure metal anode to a thickness of between 1 nm and 200 nm, inclusive, using atomic layer deposition (ALD). The ALD protection layer allows the conduction of ions of the metal of the anode therethrough but suppresses electron transport therethrough. The ALD protection layer may also be effective to inhibit passage of air and/or water therethrough. The ALD protection layer can allow more relaxed purity requirements for subsequent battery assembly, electrolyte specifications, and/or cathode gas purity. Fabrication methods for the protection layers, protected metal anodes, and systems and devices incorporating such protected metal anodes are also disclosed herein.

Kozen, Alexander C.↗