Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Prospective Studies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Study of magnetic reconnection at low- β using laser-powered capacitor coils

Magnetic reconnection is a ubiquitous fundamental process in space and astrophysical plasmas that rapidly converts magnetic energy into some combination of flow energy, thermal energy, and non-thermal energetic particles. Over the past decade, a new experimental platform has been developed to study magnetic reconnection using strong coil currents powered by high-power lasers at low plasma beta, typical conditions under which reconnection is energetically important in space and astrophysics. KJ-class lasers were used to drive parallel currents to reconnect MG-level magnetic fields in a quasi-axisymmetric geometry, similar to the magnetic reconnection experiment or MRX, and thus this platform is named micro-MRX. This presentation summarizes two major findings from micro-MRX: direct measurement of accelerated electrons and observation of ion acoustic waves during anti-parallel reconnection. The angular dependence of the measured electron energy spectrum and the resulting accelerated energies, supported by particle-in-cell simulations, indicate that direct acceleration by the out-of-plane reconnection electric field is at work. Furthermore, a sudden onset of ion acoustic bursts has been measured by collective Thomson scattering in the exhaust of magnetic reconnection, followed by electron acoustic bursts with electron heating and bulk acceleration. These results demonstrate that the micro-MRX platform offers a novel and unique approach to study magnetic reconnection in the laboratory in addition to the capabilities provided by traditional magnetized plasma experiments such as MRX and the upcoming Facility for Laboratory Reconnection experiments (FLARE). Future prospects to study other particle acceleration mechanisms and ion acoustic waves from magnetic reconnection are also discussed.

79 ASTRONOMY AND ASTROPHYSICS

Retrospective studies of operating problems in air transport

An epidemiological model for the study of human errors in aviation is presented. In this approach, retrospective data are used as the basis for formulation of hypotheses as to system factors which may have contributed to such errors. Prospective experimental studies of aviation operations are also required in order to prove or disprove the hypotheses, and to evaluate the effectiveness of intervention techniques designed to solve operational problems in the aviation system.

Billings, C. E.

Multidisciplinary geoscientific experiments in central Europe

The author has identified the following significant results. Studies were carried out in the fields of geology-pedology, coastal dynamics, geodesy-cartography, geography, and data processing. In geology-pedology, a comparison of ERTS image studies with extensive ground data led to a better understanding of the relationship between vegetation, soil, bedrock, and other geologic features. Findings in linear tectonics gave better insight in orogeny and ore deposit development for prospecting. Coastal studies proved the value of ERTS images for the updating of nautical charts, as well as small scale topographic maps. A plotter for large scale high speed image generation from CCT was developed.

Bannert, D.

Lead and uranium group abundances in cosmic rays

The importance of Lead and Uranium group abundances in cosmic rays is discussed in understanding their evolution and propagation. The electronic detectors can provide good charge resolution but poor data statistics. The plastic detectors can provide somewhat better statistics but charge resolution deteriorates. The extraterrestrial crystals can provide good statistics but with poor charge resolution. Recent studies of extraterrestrial crystals regarding their calibration to accelerated uranium ion beam and track etch kinetics are discussed. It is hoped that a charge resolution of two charge units can be achieved provided an additional parameter is taken into account. The prospects to study abundances of Lead group, Uranium group and superheavy element in extraterrestrial crystals are discussed, and usefulness of these studies in the light of studies with electronic and plastic detectors is assessed.

Yadav, J. S.

Ocular Vestibular Evoked Myogenic Potentials Using Head Striker Stimulation

Introduction: Over the last two decades, several studies have been published on the impact of long-duration (i.e., 22 days or longer) spaceflight on the central nervous system (CNS). In consideration of the health and performance of crewmembers in flight and post-flight, we are conducting a controlled prospective longitudinal study to investigate the effects of spaceflight on the extent, longevity and neural bases of sensorimotor, cognitive, and neural changes. Multiple studies have demonstrated the effects of spaceflight on the vestibular system. One of the supporting tests conducted in this protocol is the Vestibular Evoked Myogenic Potential (VEMP) test that provides a unilateral measure of otolith (saccule and utricle) function. A different approach was taken for ocular VEMP (oVEMP) testing using a head striker system (Wackym et al. 2012). The oVEMP is generally considered to be a measure of utricle function. The the otolithic input to the inferior oblique muscle is predominately from the utricular macula. Thus, quantitatively, oVEMP tests utricular function. Another practical extension of these relationships is that the oVEMP reflects the superior vestibular nerve function. Methods: Ground testing was administered on 16 control subjects and for 8 subjects over four repeated sessions spanning 70 days. The oVEMP was elicitied via a hand held striker by a vibrotactile pulse presented at the rate of 1 Hz for 24 seconds on the side of the head as subjects lay supine on a gurney. Subjects were directed to gaze approximately 25 degrees above straight ahead in semi-darkness. For the oVEMP electromyograms will be recorded with active bipolar electrodes (Delsys Inc., Boston, MA) on the infra-orbital ridge 1 cm below the eyelid with a reference electrode on the below the knee cap. The EMG potentials were amplified; band-pass filtered using a BagnoliTM Desktop EMG System (Delsys Inc., Boston, MA, USA). This EMG signal is sampled at 10 kHz and the data stimulus onset to 100 MS was averaged over 24 trial repetitions for the vibrotactile VEMP. The typical oVEMP EMG response is an excitatory potential with first peak occurring at 11-12 ms and second peak at 18 ms. This requires a total recording time of approximately 29 seconds per trial which includes 5 seconds of no vibrotactile stimulation at the beginning of the protocol. The primary dependent measures consist of the latency and peak-to-peak amplitude from the EMG signals, which will be normalized to EMG levels at the beginning of the protocol. Data were collected for 3 repeated trials with striker stimulation on both the left and right side of the head Results: The oVEMP p1 range was observed at 3-14 ms and n1 at 7-19 ms. The striker system provided a consistent and rapid method for oVEMP testing. Discussion: Crew testing is in progress to determine changes in results between pre and post flight.

De Dios, Y. E.

Potential errors in using one anemometer to characterize the wind power over an entire rotor disk

Wind data collected at four levels on a 90-m tower in a prospective wind farm area are used to evaluate how well the 10-m wind speed data with and without intermittent vertical profile measurements compare with the 90-m tower data. If a standard, or even predictable, wind speed profile existed, there would be no need for a large, expensive tower. This cost differential becomes even more significant if several towers are needed to study a prospective wind farm.

Simon, R. L.

Goal-directed ultrasound in the detection of long-bone fractures

BACKGROUND: New portable ultrasound (US) systems are capable of detecting fractures in the remote setting. However, the accuracy of ultrasound by physicians with minimal ultrasound training is unknown. METHODS: After one hour of standardized training, physicians with minimal US experience clinically evaluated patients presenting with pain and trauma to the upper arm or leg. The investigators then performed a long-bone US evaluation, recording their impression of fracture presence or absence. Results of the examination were compared with routine plain or computer aided radiography (CT). RESULTS: 58 patients were examined. The sensitivity and specificity of US were 92.9% and 83.3%, and of the physical examination were 78.6% and 90.0%, respectively. US provided improved sensitivity with less specificity compared with physical examination in the detection of fractures in long bones. CONCLUSION: Ultrasound scans by minimally trained clinicians may be used to rule out a long-bone fracture in patients with a medium to low probability of fracture.

Validation Studies

Breakthrough Propulsion Study: Assessing Interstellar Flight Challenges and Prospects

Progress toward developing an evaluation process for interstellar propulsion and power options is described. The goal is to contrast the challenges, mission choices, and emerging prospects for propulsion and power, to identify which prospects might be more advantageous and under what circumstances, and to identify which technology details might have greater impacts. Unlike prior studies, the infrastructure expenses and prospects for breakthrough advances are included. This first year's focus is on determining the key questions to enable the analysis. Accordingly, a work breakdown structure to organize the information and associated list of variables is offered. A flow diagram of the basic analysis is presented, as well as more detailed methods to convert the performance measures of disparate propulsion methods into common measures of energy, mass, time, and power. Other methods for equitable comparisons include evaluating the prospects under the same assumptions of payload, mission trajectory, and available energy. Missions are divided into three eras of readiness (precursors, era of infrastructure, and era of breakthroughs) as a first step before proceeding to include comparisons of technology advancement rates. Final evaluation "figures of merit" are offered. Preliminary lists of mission architectures and propulsion prospects are provided.

Marc G. Millis

Contrast and harmonic imaging improves accuracy and efficiency of novice readers for dobutamine stress echocardiography

BACKGROUND: Newer contrast agents as well as tissue harmonic imaging enhance left ventricular (LV) endocardial border delineation, and therefore, improve LV wall-motion analysis. Interpretation of dobutamine stress echocardiography is observer-dependent and requires experience. This study was performed to evaluate whether these new imaging modalities would improve endocardial visualization and enhance accuracy and efficiency of the inexperienced reader interpreting dobutamine stress echocardiography. METHODS AND RESULTS: Twenty-nine consecutive patients with known or suspected coronary artery disease underwent dobutamine stress echocardiography. Both fundamental (2.5 MHZ) and harmonic (1.7 and 3.5 MHZ) mode images were obtained in four standard views at rest and at peak stress during a standard dobutamine infusion stress protocol. Following the noncontrast images, Optison was administered intravenously in bolus (0.5-3.0 ml), and fundamental and harmonic images were obtained. The dobutamine echocardiography studies were reviewed by one experienced and one inexperienced echocardiographer. LV segments were graded for image quality and function. Time for interpretation also was recorded. Contrast with harmonic imaging improved the diagnostic concordance of the novice reader to the expert reader by 7.1%, 7.5%, and 12.6% (P < 0.001) as compared with harmonic imaging, fundamental imaging, and fundamental imaging with contrast, respectively. For the novice reader, reading time was reduced by 47%, 55%, and 58% (P < 0.005) as compared with the time needed for fundamental, fundamental contrast, and harmonic modes, respectively. With harmonic imaging, the image quality score was 4.6% higher (P < 0.001) than for fundamental imaging. Image quality scores were not significantly different for noncontrast and contrast images. CONCLUSION: Harmonic imaging with contrast significantly improves the accuracy and efficiency of the novice dobutamine stress echocardiography reader. The use of harmonic imaging reduces the frequency of nondiagnostic wall segments.

Non-NASA Center

The effect of simulated weightlessness on hypobaric decompression sickness

BACKGROUND: A discrepancy exists between the incidence of ground-based decompression sickness (DCS) during simulated extravehicular activity (EVA) at hypobaric space suit pressure (20-40%) and crewmember reports during actual EVA (zero reports). This could be due to the effect of gravity during ground-based DCS studies. HYPOTHESIS: At EVA suit pressures of 29.6 kPa (4.3 psia), there is no difference in the incidence of hypobaric DCS between a control group and group exposed to simulated weightlessness (supine body position). METHODS: Male subjects were exposed to a hypobaric pressure of 29.6 kPa (4.3 psi) for up to 4 h. The control group (n = 26) pre-oxygenated for 60 min (first 10 min exercising) before hypobaric exposure and walking around in the altitude chamber. The test group (n = 39) remained supine for a 3 h prior to and during the 60-min pre-oxygenation (also including exercise) and at hypobaric pressure. DCS symptoms and venous gas emboli (VGE) at hypobaric pressure were registered. RESULTS: DCS occurred in 42% in the control and in 44% in simulated weightlessness group (n.s.). The mean time for DCS to develop was 112 min (SD +/- 61) and 123 min (+/- 67), respectively. VGE occurred in 81% of the control group subjects and in 51% of the simulated weightlessness subjects (p = 0.02), while severe VGE occurred in 58% and 33%, respectively (p = 0.08). VGE started after 113 min (+/- 43) in the control and after 76 min (+/- 64) in the simulated weightlessness group. CONCLUSIONS: No difference in incidence of DCS was shown between control and simulated weightlessness conditions. VGE occurred more frequently during the control condition with bubble-releasing arm and leg movements.

NASA Discipline Environmental Health

The value of assessing pulmonary venous flow velocity for predicting severity of mitral regurgitation: A quantitative assessment integrating left ventricular function

Although alteration in pulmonary venous flow has been reported to relate to mitral regurgitant severity, it is also known to vary with left ventricular (LV) systolic and diastolic dysfunction. There are few data relating pulmonary venous flow to quantitative indexes of mitral regurgitation (MR). The object of this study was to assess quantitatively the accuracy of pulmonary venous flow for predicting MR severity by using transesophageal echocardiographic measurement in patients with variable LV dysfunction. This study consisted of 73 patients undergoing heart surgery with mild to severe MR. Regurgitant orifice area (ROA), regurgitant stroke volume (RSV), and regurgitant fraction (RF) were obtained by quantitative transesophageal echocardiography and proximal isovelocity surface area. Both left and right upper pulmonary venous flow velocities were recorded and their patterns classified by the ratio of systolic to diastolic velocity: normal (>/=1), blunted (<1), and systolic reversal (<0). Twenty-three percent of patients had discordant patterns between the left and right veins. When the most abnormal patterns either in the left or right vein were used for analysis, the ratio of peak systolic to diastolic flow velocity was negatively correlated with ROA (r = -0.74, P <.001), RSV (r = -0.70, P <.001), and RF (r = -0.66, P <.001) calculated by the Doppler thermodilution method; values were r = -0.70, r = -0.67, and r = -0.57, respectively (all P <.001), for indexes calculated by the proximal isovelocity surface area method. The sensitivity, specificity, and predictive values of the reversed pulmonary venous flow pattern for detecting a large ROA (>0.3 cm(2)) were 69%, 98%, and 97%, respectively. The sensitivity, specificity, and predictive values of the normal pulmonary venous flow pattern for detecting a small ROA (<0.3 cm(2)) were 60%, 96%, and 94%, respectively. However, the blunted pattern had low sensitivity (22%), specificity (61%), and predictive values (30%) for detecting ROA of greater than 0.3 cm(2) with significant overlap with the reversed and normal patterns. Among patients with the blunted pattern, the correlation between the systolic to diastolic velocity ratio was worse in those with LV dysfunction (ejection fraction <50%, r = 0.23, P >.05) than in those with normal LV function (r = -0.57, P <.05). Stepwise linear regression analysis showed that the peak systolic to diastolic velocity ratio was independently correlated with RF (P <.001) and effective stroke volume (P <.01), with a multiple correlation coefficient of 0.71 (P <.001). In conclusion, reversed pulmonary venous flow in systole is a highly specific and reliable marker of moderately severe or severe MR with an ROA greater than 0.3 cm(2), whereas the normal pattern accurately predicts mild to moderate MR. Blunted pulmonary venous flow can be seen in all grades of MR with low predictive value for severity of MR, especially in the presence of LV dysfunction. The blunted pulmonary venous flow pattern must therefore be interpreted cautiously in clinical practice as a marker for severity of MR.

Non-NASA Center

Drug-induced kidney injury: challenges and opportunities

Abstract Drug-induced kidney injury (DIKI) is a frequently reported adverse event, associated with acute kidney injury, chronic kidney disease, and end-stage renal failure. Prospective cohort studies on acute injuries suggest a frequency of around 14%–26% in adult populations and a significant concern in pediatrics with a frequency of 16% being attributed to a drug. In drug discovery and development, renal injury accounts for 8 and 9% of preclinical and clinical failures, respectively, impacting multiple therapeutic areas. Currently, the standard biomarkers for identifying DIKI are serum creatinine and blood urea nitrogen. However, both markers lack the sensitivity and specificity to detect nephrotoxicity prior to a significant loss of renal function. Consequently, there is a pressing need for the development of alternative methods to reliably predict drug-induced kidney injury (DIKI) in early drug discovery. In this article, we discuss various aspects of DIKI and how it is assessed in preclinical models and in the clinical setting, including the challenges posed by translating animal data to humans. We then examine the urinary biomarkers accepted by both the US Food and Drug Administration (FDA) and the European Medicines Agency for monitoring DIKI in preclinical studies and on a case-by-case basis in clinical trials. We also review new approach methodologies (NAMs) and how they may assist in developing novel biomarkers for DIKI that can be used earlier in drug discovery and development.

Connor, Skylar (ORCID:0000000233479180)

Spin-dependent dark matter scattering in quasi-two-dimensional magnets

We study the prospects of detecting dark matter coupled to the spin of the electron, such that it may scatter and excite magnons—collective excitations of electronic spins. We show that materials exhibiting long-range magnetic order where the spins are coupled only along a plane may act as directional dark matter detectors. These quasi-two-dimensional materials possess anisotropic dispersion relations and structure functions which induce a sidereal modulation in the excitation rate. We calculate the expected signal rate for some candidate (anti)ferromagnets, demonstrating a possible route to the direct detection of spin-dependent dark matter in the keV to MeV mass range.

Dark matter direct detection

Three dimensional global modeling of atmospheric CO2

A model was developed to study the prospects of extracting information on carbon dioxide sources and sinks from observed CO2 variations. The approach uses a three dimensional global transport model, based on winds from a 3-D general circulation model (GCM), to advect CO2 noninteractively, i.e., as a tracer, with specified sources and sinks of CO2 at the surface. The 3-D model employed is identified and biosphere, ocean and fossil fuel sources and sinks are discussed. Some preliminary model results are presented.

Fung, I.

Life Sciences Research Facility automation requirements and concepts for the Space Station

An evaluation is made of the methods and preliminary results of a study on prospects for the automation of the NASA Space Station's Life Sciences Research Facility. In order to remain within current Space Station resource allocations, approximately 85 percent of planned life science experiment tasks must be automated; these tasks encompass specimen care and feeding, cage and instrument cleaning, data acquisition and control, sample analysis, waste management, instrument calibration, materials inventory and management, and janitorial work. Task automation will free crews for specimen manipulation, tissue sampling, data interpretation and communication with ground controllers, and experiment management.

Rasmussen, Daryl N.

Can MACHOs probe the shape of the galaxy halo ?

Microlensing searches in our galaxy have recently discovered several candidates in the direction of the Large Magellanic Cloud (LMC). We study the prospects for such searches to yield useful information about the flattening of the Galaxy dark matter halo, using a self-consistent oblate halo model and allowing for the possibility of misalignment between the disk and halo symmetry axes. The microlensing optical depth for the LMC, tau(LMC), depends sensitively on the disk-halo tilt angle in the Milky Way, as does the ratio tau(SMC)/tau(LMC). If the tilt angle is as large as 30 deg, a much larger spread in values for tau(LMC) is consistent with rotation curve constraints than previously thought. Disk-halo tilt and halo flattening do not significantly affect the massive compact halo object (MACHO) masses inferred from event durations.

Frieman, Joshua

Centaurus A, the core of the problem

The bright, peculiar elliptical galaxy Centaurus A (NGC 5128, PKS 1322-427) was one of the first extragalactic radio sources to be optically identified (Bolton et al. 1949). At a distance of 4 Mpc, Centaurus A is the closest active radio galaxy and affords the highest linear imaging resolution (1 mas approximately equal to 0.02 pc) and hence the best prospects for studying an active nucleus close to the central radio source. We present the results of multi-epoch, 8.4-GHz, very long baseline interferometry (VLBI), imaging observations of the nucleus made over the past three years. The nucleus possesses a core-jet structure where the inner portion of the jet shows apparent linear motion with a velocity substantially less than the speed of light.

Tingay, S. J.