Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Primary frequency control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Cosmic Reionization on Computers: Physical Origin of Long Dark Gaps in Quasar Absorption Spectra

I explore the properties of “dark gaps” - regions in quasar absorption spectra without significant transmission - with several simulations from the Cosmic Reionization On Computers (CROC) project. The CROC simulations in the largest available boxes (120 cMpc) come close to matching both the distribution of mean opacities and the frequency of dark gaps, but alas not in the same model: the run that matches the mean opacities fails to contain enough dark gaps and vice versa. Nevertheless, the run that matches the dark gap distributions serves as a counterexample to claims in the literature that the dark gap statistics requires a late end to reionization - in that run reionization ends at z = 6.7 (likely too early). While multiple factors contribute to the frequency of large dark gaps in the simulations, the primary factor that controls the overall shape of the dark gap distribution is the ionization level in voids—the lowest-density regions produce the highest transmission spikes that terminate long gaps. As the result, the dark gap distribution correlates strongly with the fraction of the spectrum above the gap detection threshold and the observed distribution is matched by the simulation in which this fraction is 2%. Hence, the gap distribution by itself does not constrain the timing of reionization, although it may do so in combination with the distribution of mean opacities.

79 ASTRONOMY AND ASTROPHYSICS↗

Time domain and frequency domain design techniques for model reference adaptive control systems

Some problems associated with the design of model-reference adaptive control systems are considered and solutions to these problems are advanced. The stability of the adapted system is a primary consideration in the development of both the time-domain and the frequency-domain design techniques. Consequentially, the use of Liapunov's direct method forms an integral part of the derivation of the design procedures. The application of sensitivity coefficients to the design of model-reference adaptive control systems is considered. An application of the design techniques is also presented.

Boland, J. S., III↗

Control co-design under uncertainty for offshore wind farms: Optimizing grid integration, energy storage, and market participation

Offshore wind farms (OWFs) are set to significantly contribute to global decarbonization efforts. Developers often use a sequential approach to optimize design variables and market participation for grid-integrated offshore wind farms. However, this method can lead to sub-optimal system performance, and uncertainties associated with renewable resources are often overlooked in decision-making. Here, this paper proposes a control co-design approach, optimizing design and control decisions for integrating OWFs into the power grid while considering energy market and primary frequency market participation. Additionally, we introduce optimal sizing solutions for energy storage systems deployed onshore to enhance revenue for OWF developers over time. This framework addresses uncertainties related to wind resources and energy prices. We analyze five U.S. west-coast offshore wind farm locations and potential interconnection points, as identified by the Bureau of Ocean Energy Management (BOEM). Results show that optimized control co-design solutions can increase market revenue by 3.2% and provide flexibility in managing wind resource uncertainties.

Control Co-design↗

Biomechanically Induced and Controller Coupled Oscillations Experienced on the F-16XL Aircraft During Rolling Maneuvers

During rapid rolling maneuvers, the F-16 XL aircraft exhibits a 2.5 Hz lightly damped roll oscillation, perceived and described as 'roll ratcheting.' This phenomenon is common with fly-by-wire control systems, particularly when primary control is derived through a pedestal-mounted side-arm controller. Analytical studies have been conducted to model the nature of the integrated control characteristics. The analytical results complement the flight observations. A three-degree-of-freedom linearized set of aerodynamic matrices was assembled to simulate the aircraft plant. The lateral-directional control system was modeled as a linear system. A combination of two second-order transfer functions was derived to couple the lateral acceleration feed through effect of the operator's arm and controller to the roll stick force input. From the combined systems, open-loop frequency responses and a time history were derived, describing and predicting an analogous in-flight situation. This report describes the primary control, aircraft angular rate, and position time responses of the F-16 XL-2 aircraft during subsonic and high-dynamic-pressure rolling maneuvers. The analytical description of the pilot's arm and controller can be applied to other aircraft or simulations to assess roll ratcheting susceptibility.

Smith, John W.↗

Intelligent Optimization of the Digital Low Level RF Control System for LANSCE LINAC

The LINAC at the Los Alamos Neutron Science Center (LANSCE) accelerates protons from 750 keV to its final energy at 800 MeV via 48 radio frequency (RF) modules. However, the startup and recovery process of the low-level RF (LLRF) systems, the primary controls for the RF modules, cost significant time for the beam operation, while the process itself is highly prone to human errors. With the new conversion from the analog LLRF (aLLRF) to digital LLRF (dLLRF) system under the recent LANSCE Modernization Project, new approaches with the new dLLRF capabilities can be achieved to address this issue. We propose to develop an intelligent optimization scheme that can significantly lower the downtime caused by the LLRF systems. This directly address the MFR problem statement that asks for “innovative engineering improvements to ancillary systems such as RF and pulsed power that improve reliability, maintainability, and/or performance.”

43 PARTICLE ACCELERATORS↗

A 2-to-48-MHz Phase-Locked Loop

A 2-to-48-MHz phase-locked loop (PLL), developed for the U.S. space program, meets or exceeds all space shuttle clock electrical interface requirements by taking as its reference a 2-to-48-MHz clock signal and outputting a phaselocked clock signal set at the same frequency as the reference clock with transistor- transistor logic (TTL) voltage levels. Because it is more adaptable than other PLLs, the new PLL can be used in industries that employ signaling devices and as a tool in future space missions. A conventional PLL consists of a phase/frequency detector, loop filter, and voltage-controlled oscillator in which each component exists individually and is integrated into a single device. PLL components phase-lock to a single frequency or to a narrow bandwidth of frequencies. It is this design, however, that prohibits them from maintaining phase lock to a dynamically changing reference clock when a large bandwidth is required a deficiency the new PLL overcomes. Since most PLL components require their voltage-controlled oscillators to operate at greater than 2-MHz frequencies, conventional PLLs often cannot achieve the low-frequency phase lock allowed by the new PLL. The 2-to-48-MHz PLL is built on a wire-wrap board with pins wired to three position jumpers; this makes changing configurations easy. It responds to variations in voltage-controlled oscillator (VCO) ranges, duty cycle, signal-to-noise ratio (SNR), amplitude, and jitter, exceeding design specifications. A consensus state machine, implemented in a VCO range detector which assures the PLL continues to operate in the correct range, is the primary control state machine for the 2-to-48-MHz PLL circuit. By using seven overlapping frequency ranges with hysteresis, the PLL output sets the resulting phase-locked clock signal at a frequency that agrees with the reference clock with TTL voltage levels. As a space-shuttle tool, the new PLL circuit takes the noisy, degraded reference clock signals as input and outputs phase-locked clock signals of the same frequency but with a corrected wave shape. Since its configuration circuit can be easily changed, the new PLL can do the following: readily respond to variations in VCO ranges, duty cycle, SNR, amplitude, and jitter; continuously operate in the correct VCO range because of its consensus state machine; and use its range detector implements to overlap seven frequency ranges with hysteresis, thus giving the current design a flexibility that exceeds anything available at the time of this development. These features will benefit any industry in which safe and timely clock signals are vital to operation.

Koudelka, Robert D.↗

Coordinated Frequency Regulation in Grid-Forming Storage Network via Safety-Consensus

Inverter-based storages are poised to play a prominent role in future power grid with massive renewable generation. Grid-forming inverters (GFMs) are emerging as a dominant technology with synchronous generators (SG)-like characteristics through primary control loops. Advanced secondary-layer control schemes, e.g., consensus algorithms, allow GFM-interfaced storage units to participate in frequency regulations and restore nominal frequency following grid disturbances. However, it is imperative to ensure critical frequency safety limits are not violated while the grid transitions from pre- to post-disturbance operating point. This paper presents a novel safety-enforced consensus method, having three distinct objectives: safe transient frequency evolution, minimizing frequency deviation, and coordinated power sharing. The proposed technique is illustrated using a GFM-interfaced grid-wide storage network on the IEEE 68-bus system under multiple grid transient scenarios.

consensus control↗

Synchronized Phasor Measurement Unit-based Central Controller for Normal and Contingent Operation of a High-Capacity HVDC Macrogrid for the Continental US

This paper presents a Synchronized Phasor Measurement Unit (PMU) based controller to support the coordination and operation of a high-capacity high-voltage direct current (HVDC) macrogrid transmission for the continental US. The proposed controller allows for optimal scheduling of each segment of the multi-terminal HVDC network under normal and contingent conditions, while considering minimum levels of frequency response requirements. The performance of the proposed controller is tested on a 100,222-bus representation of the US Eastern and Western interconnections. Results show that a centralized PMU-based controller improves the frequency nadir of the HVDC macrogrid under contingency conditions by 25.9%. Furthermore, the primary frequency response (PFR) of the HVDC macrogrid is increased by 33.4%. The performance of each interconnection under the largest credible contingency conditions is also discussed.

Mohan, Nihal↗

Theoretical Study of Multicyclic Control of a Controllable Twist Rotor

Analytical studies were performed to ascertain the feasibility of reducing helicopter rotor induced 4/rev vibratory forces by means of multicyclic flap control input on a dual control, four bladed rotor system. The dual control consisted of a primary inboard pitch horn blade control and a secondary outboard flap control. Flap control was put in at frequencies greater than the rotor rotational speed.

Lemnios, A. Z.↗

Summary of GFL Inverter Capability and Performance: Malawi [Slides]

This presentation provides a comprehensive comparison of inverter-based resource (IBR) technical requirements across multiple international grid codes - including IEEE 2800, ESO, EirGrid, and Malawi's evolving regulatory framework - to support capacity building for electricity-sector institutions in Malawi. It highlights key performance expectations for grid-following (GFL) inverters across critical domains such as primary and fast frequency response, ramping behavior, frequency and voltage ride-through capabilities, reactive power and voltage control, ROCOF withstand, phase jump tolerance, system strength considerations, protection schemes, and dynamic modeling requirements. Emphasizing a "Do no harm, do something, do more" philosophy, the document synthesizes best practices and operational benchmarks to guide the integration and stability of inverter-based resources within Malawi's power system. The presentation forms part of the SABESS Center of Excellence initiative supported by the Global Energy Alliance for People and the Planet.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of helicopter maneuver-loads and rotor-loads flight test data

A study was conducted in which available airload and blade response data for the NH-3A and CH-53A rotors were analyzed in an attempt to provide greater insight into the sources of rotor vibratory loads in both level and maneuvering flight. Primary emphasis in the study was placed on examining and understanding causes of high-frequency rotor control loads. Secondary objectives were: (1) to examine the effect of number of rotor blades on hub vibratory shear forces and (2) to assess which of the many terms appearing in the hub vibratory shear force expression were of most significance.

Beno, E. A.↗

Extremely lightweight space telescope mirrors with integrated active figure control

A concept for an extremely lightweight primary mirror for a large space telescope is proposed. The mirror uses a sandwich structure composed of aluminum faceplates with an aluminum foam core. Modal analysis indicates that a fundamental frequency of 100 Hz can be obtained for a 6 meter diameter mirror with a tapered back and having a total mass of about 3500 kg. An array of thermal actuators embedded in the mirror corrects for figure errors. Such an active thermal figure control system does not have a quick response, but is well suited to space applications where disturbances have relatively long time constants. The advantage of thermal actuators is very high reliability, a primary concern in any space system requiring a large number of actuators.

Bely, Pierre Y.↗

FOSWEC dynamics and controls test report

This report describes the testing of a model scale wave energy converter. This device, which uses two aps that pivot about a central platform when excited by waves, has a natural frequency within the range of the waves by which it is excited. The primary goal of this test was to assess the degree to which previously developed modeling, experimentation, and control design methods could be applied to a broad range of wave energy converter designs. Testing was conducted to identify a dynamic model for the impedance and excitation behavior of the device. Using these models, a series of closed loop tests were conducted using a causal impedance matching controller. This report provides a brief description of the results, as well as a summary of the device and ex- perimental design. The results show that the methods applied to this experimental device perform well and should be broadly applicable.

16 TIDAL AND WAVE POWER↗

Defect-Enhanced Polarization Switching in the Improper Ferroelectric LuFeO 3

Results of switching behavior of the improper ferroelectric LuFeO 3 are presented. Here, using a model set of films prepared under controlled chemical and growth-rate conditions, it is shown that defects can reduce the quasi-static switching voltage by up to 40% in qualitative agreement with first-principles calculations. Switching studies show that the coercive field has a stronger frequency dispersion for the improper ferroelectrics compared to a proper ferroelectric such as PbTiO 3 . It is concluded that the primary structural order parameter controls the switching dynamics of such improper ferroelectrics.

36 MATERIALS SCIENCE↗

An innovative approach to compensator design

The primary goal is to present for a control system a computer-aided-compensator design technique from a frequency domain point of view. The thesis for developing this technique is to describe the open loop frequency response by n discrete frequency points which result in n functions of the compensator coefficients. Several of these functions are chosen so that the system specifications are properly portrayed; then mathematical programming is used to improve all of these functions which have values below minimum standards. In order to do this several definitions in regard to measuring the performance of a system in the frequency domain are given. Next, theorems which govern the number of compensator coefficients necessary to make improvements in a certain number of functions are proved. After this a mathematical programming tool for aiding in the solution of the problem is developed. Then for applying the constraint improvement algorithm generalized gradients for the constraints are derived. Finally, the necessary theory is incorporated in a computer program called CIP (compensator improvement program).

Mitchell, J. R.↗

Decentralized Distribution System Restoration with Grid-Forming/Following Inverter-Based Resources

The high penetration of distributed energy resources (DERs) in active distribution systems has posed challenges to the centralized distribution system restoration (DSR) strategies in current practice. On the other hand, the advancement in smart inverter technologies enables the bottom-up restoration capability. This paper is motivated to develop a 3-layered hierarchical framework for decentralized DSR, based on the grid-forming (GFM) and grid-following (GFL) grid-edge inverters. The first layer presents the tertiary control, which determines the load pickup schedule and generation dispatch of DERs, using the alternating direction method of the multipliers algorithm. The second layer consists of two control functions: GFM control, which regulates voltage and frequency, establishing a stable grid for GFL inverters to follow; and GFL control, which regulates the real and reactive power. In the third layer, the primary control is proposed to regulate the inverter voltage and current, which is developed based on the virtual oscillator control (VOC). Furthermore, the developed framework is tested in the modified IEEE 13-node test feeder. Two scenarios of grid-connected and islanded operating modes are designed, and simulation results demonstrate the effectiveness of decentralized DSR strategies for controlling grid-edge inverters to enhance the distribution system resilience.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simplified dc to dc converter

A dc to dc converter which can start with a shorted output and which regulates output voltage and current is described. Voltage controlled switches directed current through the primary of a transformer the secondary of which includes virtual reactance. The switching frequency of the switches is appropriately varied to increase the voltage drop across the virtual reactance in the secondary winding to which there is connected a low impedance load. A starting circuit suitable for voltage switching devices is provided.

Gruber, R. P.↗

Langley Research Center Photogrammetric Measurements of Solar Array Dynamics: Preliminary Results

The NASA Langley Research Center participated in the Solar Array Experiment with two primary objectives: (1) to study the structural and control dynamics of a new class of large, lightweight, low-frequency space structures, and (2) to develop technology for remote video measurement of structural motions. The shuttle orbiter's closed circuit television (CCTV) system was used to provide recorded video images of the solar array from four locations in the payload bay, two on the forward bulkhead and two on the aft bulkhead. White reflective targets were placed on the array to provide discrete points at which to track array motion. A dynamic test consisted of a quiescent period in which orbiter operations were inhibited and crew motion restricted, an excitation period, and a free decay period. The orbiter was placed in free drift while in a gravity gradient orientation and dynamics tests were timed to occur at orbital noon so that the Sun would illuminate one side of the array and Earth albedo the other. The CCTV system was turned on during the quiescent period, approximately 3 minutes prior to excitation. Video from all four CCTV cameras was recorded continuously through the excitation and free-decay periods for a total test record of 8 to 10 minutes.

Brumfield, M. L.↗