Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pneumatic Valves”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Pneumatic shutoff and time-delay valve operates at controlled rate

Shutoff and time delay valve, which incorporates a metering spool that moves at constant velocity under pneumatic pressure and spring compression, increases fluid-flow area at a uniform rate. Diaphragm areas, control cavity volume, and bleed-orifice size may be varied to give any desired combination of time delay and spool travel time.

Horning, J. L.↗

Pioneer Venus Sounder Probe Neutral Gas Mass Spectrometer

A neutral gas mass spectrometer was flown to Venus as part of the Pioneer Venus Multiprobe to measure the composition of its lower atmosphere. The instrument, mounted in the Sounder Probe, was activated after the probe entered the top of the atmosphere, and it obtained data during the descent from 62 km to the surface. Atmospheric gases were sampled through a pair of microleaks, the effluent from which was pumped by a combination of ion and getter pumping. A pneumatically operated valve, controlled by the ambient atmospheric pressure, maintained the ion source pressure at a nearly constant value during descent while the atmospheric pressure varied by three orders of magnitude. A single focusing magnetic sector field mass spectrometer with mass resolution sufficient to reasonably separate argon from C3H4 at 40 amu provided the mass analysis and relative abundance measurements. A microprocessor controlled the operation of the mass spectrometer through a highly efficient peak-tip stepping routine and data compression algorithm that effected a scan of the mass spectrum from 1 to 208 amu in 64 sec while requiring an information rate of only 40 bits/sec to return the data to earth. A subscale height altitude resolution was thus obtained. Weight, size, and power requirements were minimized to be consistent with interplanetary flight contraints.

Hoffman, J. H.↗

System Measures Pressures Aboard A Compressor Rotor

Rotating pressure-measuring instrumentation includes on-board calibration standard. Computer-controlled, multichannel instrumentation system acquires pressure measurements from sensors mounted in 1.52-m-diameter rotor of compressor. Includes 5 miniature, electronically scanned pressure (ESP) modules, each containing 48 piezoresistive pressure sensors, pneumatic calibration valve, and electronic circuits for addressing and amplifying output of each sensor. Modules mounted on centerline of rotor, on instrumentation tower located inside nose cone of rotor. Subsystem designed to convert analog signal to distinct frequency without significantly affecting accuracy.

Freedman, Robert J.↗

Development of the ISS NORS

This paper will discuss the design and development of the Nitrogen Oxygen Recharge System (NORS) for the International Space Station (ISS). The emphasis of the paper is the collaborative effort between The Boeing Company and Cobham in the crafting of the architecture of the system to meet NASA's requirements. Specific examples to be discussed include the inclusion of the pneumatic isolation valve for compliance with safety requirement, the inclusion of a single stage regulator with flow limiter versus a two-stage regulator, and the use of integrated assemblies as opposed to separate valves/regulators. The paper will also discuss NORS experience with integrated assemblies (common body) verses prior ISS hardware and Cobham trade study efforts, to include lessons learned and potential applications to future programs.

Brandon, Richard↗

Enterprise: a reduced-scale, flexible fuel, single-cylinder crosshead marine diesel research engine

A custom-built 1/10 scale, flexible-fuel, single-cylinder crosshead marine diesel research engine, dubbed the Enterprise, was designed and built as a platform for conducting marine lubricant research. The engine design was focused on maintaining lubricant boundary conditions similar those of full-scale engines. The Enterprise has a rated speed of 625 rpm to match the linear mean piston speed of full-scale marine engines with the reduced stroke and is capable of 18 bar brake mean effective pressure (BMEP). A high-swirl, uniflow-scavenged, two-stroke combustion system was designed to operate on either distillate diesel or heavy fuel oil (HFO). A hydraulic electronic unit injector (HEUI) fuel injection system with two injectors having customized three-hole nozzles provides fueling and is driven by the MAHLE Flexible ECU (MFE). Intake air boost is provided using a variable speed industrial air compressor along with closed-loop electronically controlled pressure regulation. Exhaust backpressure is also controlled electronically using an electro-pneumatic butterfly valve. A customized, miniaturized Hans Jensen Lubetronic cylinder lubrication system, which is capable of delivering 0.88 mg of cylinder oil per lubricator per injection to the ring pack at up to the maximum engine overspeed rating of 656 rpm, was commissioned for the Enterprise. Four independently temperature-controlled cooling zones are used to provide control of the liner temperature profile. The four coolant zones as well as the system oil and cylinder oil supplies are all controlled within 1°C for consistent thermal boundary conditions. The engine is instrumented with an in-cylinder pressure transducer as well as an inline torque transducer and numerous process temperature and pressure measurements to allow for detailed thermodynamic efficiency analysis, and experimental facilities allow for precise measurement of liner wear and characterization of deposits on the piston and rings. A radio telemetry system from IR Telemetrics is used to measure piston crown temperatures during engine operation. Engine design considerations and experimental facilities are described in detail, along with the results of a study investigating the impact of both system oil and cylinder oil viscosity on friction and efficiency. A test matrix was designed to compare base stock chemistries and viscosities for both system and cylinder oils. Experiments were completed using a fuel economy test protocol that was defined, consisting of repeating six speed/load operating conditions. An automated dynamometer control system was implemented to ensure repeatability of the test procedure. Preliminary testing indicated that the coolant, oil, and exhaust temperatures reach a steady state within 5 minutes of changing operating conditions. The system oil viscosity was found to have a significant impact on friction, with a reduction in viscosity from SAE 30 to SAE 20 resulting in over 6% reduction in friction mean effective pressure (FMEP) and over a 2% reduction in brake-specific fuel consumption (BSFC). Chemistry effects were also evident in the system and cylinder oils. Repeatability comparisons between the individual repetitions of each operating condition were used to ensure that results are statistically valid. For the initial cylinder oil viscosity experiments, observed changes were within the established/normal repeatability; ongoing experiments will determine whether improvements in boundary condition control will enable cylinder friction changes of this magnitude to be measured on this engine platform.

Kaul, Brian↗

Thermal Integration of DETAIL Systems

A thermal connection between the Microreactor AGile Non-nuclear Experimental Testbed (MAGNET) and the thermal energy distribution system (TEDS) has been a key part of the Dynamic Energy Transport and Integration Laboratory (DETAIL) plan since the development of the Integrated Energy Systems Roadmap in 2020. This connection provides an expanding demonstration capability for integrated system operations. The thermal connection between MAGNET and TEDS required the selection of a heat exchanger and valves to isolate flow. Research staff within the NEET Crosscutting Technology Development program selected equipment after receiving proposals from multiple vendors. A helical coil heat exchanger from Graham Corporation was selected for its small volume relative to its heat transfer surface area to fit in the limited space available. Triple offset butterfly valves with pneumatic actuators from Flowserve were selected to isolate and/or control flow of the hot gas through the heat exchanger. Staff from Idaho National Laboratory’s (INL) Facilities and Site Services Engineering department designed the piping and structural support. A mechanical construction firm was contracted to install the system. This report documents the design and construction of this thermal connection.

25 ENERGY STORAGE↗

Main Oxidizer Valve Design

A developmental Main Oxidizer Valve (MOV) was designed by NASA-MSFC using additive manufacturing processes. The MOV is a pneumatically actuated poppet valve to control the flow of liquid oxygen to an engine's injector. A compression spring is used to return the valve to the closed state when pneumatic pressure is removed from the valve. The valve internal parts are cylindrical in shape, which lends itself to traditional lathe and milling operations. However, the valve body represents a complicated shape and contains the majority of the mass of the valve. Additive manufacturing techniques were used to produce a part that optimized mass and allowed for design features not practical with traditional machining processes.

Addona, Brad↗

Microfabricated Renewable Beads-Trapping/Releasing Flow Cell for Rapid Antigen-Antibody Reaction in Chemiluminescent Immunoassay

A filter pillar-array microstructure was coupled with a pneumatic micro-valve to fabricate a reusable miniaturized beads-trapping/releasing flow cell, in which trapping and releasing beads can be conveniently realized by switching the micro-valve. This miniaturized device was suitable to construct automatic fluidic system for “renewable surface analysis”. The renewable surface strategy based on pneumatic micro-valve enabled capture of beads in beads chamber prior to each assay, and release of the used beads after the assay. Chemiluminescent competitive immunoassay of 3,5,6-trichloropyridinol (TCP) was performed as a model to demonstrate the application potential of this reusable miniaturized flow cell. The whole fluidic assay process including beads trapping, immuno-binding, beads washing, beads releasing and signal collection could be completed in 10 min. Immunoassay of TCP using this miniaturized device showed a linear range of 0.20-70 ng/mL with a limit of detection of 0.080 ng/mL. The device had been successfully used for detection of TCP spiked in rat serum with average recovery of 97%. This investigation provides a rapid, sensitive, reusable, low-cost and automatic miniaturized device for solid-phase biochemical analysis for various purposes.

60 APPLIED LIFE SCIENCES↗

Dynamic response characteristics of a circulation control rotor model pneumatic system

Numerical and experimental simulation of unsteady airflow through the control valve and slotted air duct of a circulation control rotor is described. The numerical analysis involves the solution of the quasi-one-dimensional compressible fluid-dynamic equations in the blade air duct together with the coupled isentropic flow equations for flow into the blade through the valve and out of the blade through the Coanda slot. Numerical solutions are compared with basic experimental results obtained for a mockup of a circulation control rotor and its pneumatic valving system. The pneumodynamic phenomena that were observed are discussed with particular emphasis on the characteristic system time lags associated with the response of the flow variables to transient and periodic control valve inputs.

Watkins, C. B.↗

Automatic amino acid analyzer

Analyzer operates unattended or up to 15 hours. It has an automatic sample injection system and can be programmed. All fluid-flow valve switching is accomplished pneumatically from miniature three-way solenoid pilot valves.

Berdahl, B. J.↗

Microfluidic Pumps Containing Teflon [Trademark] AF Diaphragms

Microfluidic pumps and valves based on pneumatically actuated diaphragms made of Teflon AF polymers are being developed for incorporation into laboratory-on-a-chip devices that must perform well over temperature ranges wider than those of prior diaphragm-based microfluidic pumps and valves. Other potential applications include implanted biomedical microfluidic devices, wherein the biocompatability of Teflon AF polymers would be highly advantageous. These pumps and valves have been demonstrated to function stably after cycling through temperatures from -125 to 120 C. These pumps and valves are intended to be successors to similar prior pumps and valves containing diaphragms made of polydimethylsiloxane (PDMS) [commonly known as silicone rubber]. The PDMS-containing valves ae designed to function stably only within the temperature range from 5 to 80 C. Undesirably, PDMS membranes are somwehat porous and retain water. PDMS is especially unsuitable for use at temperatures below 0 C because the formation of ice crystals increases porosity and introduces microshear.

Willis, Peter↗

Detection of gas leakage

A method of detecting leaks and measuring volumes as well as an apparatus, the Power-free Pump Module (PPM), that is a self-contained leak test and volume measurement apparatus that requires no external sources of electrical power during leak testing or volume measurement, where the invention is a portable, pneumatically-controlled instrument capable of generating a vacuum, calibrating volumes, and performing quantitative leak tests on a closed test system or device, all without the use of alternating current (AC) power. Capabilities include the ability is to provide a modest vacuum (less than 10 Torr), perform a pressure rise leak test, measure the gas's absolute pressure, and perform volume measurements. All operations are performed through a simple rotary control valve which controls pneumatically-operated manifold valves.

47 OTHER INSTRUMENTATION↗

Detection of gas leakage

A method of detecting leaks and measuring volumes as well as a device, the Power-free Pump Module (PPM), provides a self-contained leak test and volume measurement apparatus that requires no external sources of electrical power during leak testing or volume measurement. The PPM is a portable, pneumatically-controlled instrument capable of generating a vacuum, calibrating volumes, and performing quantitative leak tests on a closed test system or device, all without the use of alternating current (AC) power. Capabilities include the ability is to provide a modest vacuum (less than 10 Torr) using a venturi pump, perform a pressure rise leak test, measure the gas's absolute pressure, and perform volume measurements. All operations are performed through a simple rotary control valve which controls pneumatically-operated manifold valves.

47 OTHER INSTRUMENTATION↗

AeroValve Experimental Test Data Final Report

This report documents the collection of experimental test data and presents performance characteristics for the AeroValve brand prototype pneumatic bidirectional solenoid valves tested at the Oak Ridge National Laboratory (ORNL) in July/August 2014 as part of a validation of AeroValve energy efficiency claims. The test stand and control programs were provided by AeroValve. All raw data and processing are included in the report attachments.

42 ENGINEERING↗

Natural Gas Extraction, Pneumatic Venting

This unit process quantifies the mass of gas emitted as a result of (fugitive) venting from pneumatic devices and valves used during natural gas extraction. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=46843EAE-A896-4E20-91E1-8403563F9876

03 NATURAL GAS↗

Natural Gas Processing, Pneumatic Venting

This unit process quantifies the mass of methane emitted as a result of (fugitive) venting from pneumatic devices and valves used at natural gas processing plants. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=8C8616B4-3004-4193-8AAB-051045968864

03 NATURAL GAS↗